Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Thermographic Cube Camera Quick Start Guide Thermographic Cube Camera English Deutsch Français Español Português Italiano Čeština Slovenčina Polski Magyar Română Nederlands Dansk Norsk Suomi Svenska Русский Türkçe 日本語 한국인 繁體中文 1 A 2 B B.1 B.2 3 B.3 4 B.4 5 English 1. Introduction Thermographic Cube Camera Series is able to measure object’s temperature at a high accuracy in real time. For the model with 433 MHz data transmission function, it is capable of wireless data transmission among different transducers and gateways. It is often applied to electric system, industrial automation, etc. for fire prevention. The pre-alarm and network system helps you discover unexpected events immediately and protects your property effectively. 2. Appearance (Page 1 – A) Component & Interface No. Component Description 1 Magnatic Installation Panel Installation panel. Choose one of the following ways to mount the device ● Attach the device to a ferromagnetic surface ● Screw the device to installation surface. 2 Power Indicator ● Solid Red: Start normally. ● Solid Green: Work normally. 3 Network Indicator ● Solid Yellow: Network connection failed. ● Flashing Yellow: Network connection succeeded. 4 Thermal Lens Aiming at targets for temperature measurement 5 Reset Button To reset the device, you need to hold the reset button to boot it. Then keep holding the reset button for 5 seconds, and wait until the power indicator turns from red to green. 6 Cable Connector Aviation plug, female. 7 Cable Connector Aviation plug, male. Screw the male connector clockwisely to fix the cable. 8 Serial Port For debugging 9 RS-485 Port For RS-485 communication 10 Power Supply 12 VDC input 11 Network RJ45 Network Interface, 100M 6 3. Install Camera (Page 2 – B) Before installation, make sure that the installation surface is strong enough to withstand four times the weight of the device and the accessory. Check the specification of the products for the installation environment. Select a desired installation method from B.1 to B.4. Installation Method and Steps Method Steps B.1 1. Attach the device to a ferromagnetic surface. B.2 1. Paste the drill template to the installation surface. 2. Drill 4 screw holes (Ø3 mm) according to the “2” holes. 3. Screw the device to the surface with 4 supplied M3×10. B.3 1. Paste the drill template to the installation surface. 2. Drill 4 screw holes (Ø3.5 mm) according to the “1” holes. 3. Screw the device to the surface with supplied M3×15 screws and M3 nuts. B.4 Purchase a PT joint in advance. 1. Disamble the PT joint. 2. Install the PT joint base to installation surface, and then install the PT joint bracket back. 3. Fix the device to the PT joint bracket. 4. User Manual Legal Information ©2022 Hangzhou Microimage Software Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the HIKMICRO website (www.hikmicrotech.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. 7 Trademarks Acknowledgement and other HIKMICRO’s trademarks and logos are the properties of HIKMICRO in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. LEGAL DISCLAIMER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKMICRO MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKMICRO BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKMICRO SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKMICRO WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. 8 Regulatory Information FCC Information Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency…
Text truncated - open the document above for the full version.
Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Hangzhou Microimage Software Co., Ltd. Address Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict,Binjiang District, Hangzhou, China Grantee Code 2AXVM FCC ID 2AXVM-3117T-QS Authorized Contact Name Wen Fang Contact Email [email protected] Contact Phone 17280719017 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 2022/07/02 Print Name: Wen Fang Title: Certification Engineer *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
Hangzhou Microimage Software Co., Ltd. Date: 2022-07-02 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AXVM-3117T-QS To whom it may concern: We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Microimage Software Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Wen Fang Title: Certification Engineer Signature: On behalf of Company: Hangzhou Microimage Software Co., Ltd. Telephone: 17280719017
Hangzhou Microimage Software Co., Ltd. To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Hangzhou Microimage Software Co., Ltd. Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict,Binjiang District, Hangzhou, China Regarding: Confidentiality Request regarding application for FCC ID: 2AXVM-3117T-QS LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature: Printed Name (on file with the FCC associated with the Grantee Code): Wen Fang Title: Certification Engineer Company Name: Hangzhou Microimage Software Co., Ltd.
Hangzhou Microimage Software Co., Ltd. Current Date : 2022-07-02 To: SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. No. 588 West Jindu Road, Songjiang District, Shanghai, China. 201612 Dear Sir/Madam, Subject: Declaration Letter about Identity of Products *WE (Hangzhou Microimage Software Co., Ltd.) HEREBY DECLARED THAT Product Description Thermographic Cube Camera Model No. HM-TD3117T-2/Q/S Manufacturer’s Name Hangzhou Microimage Software Co., Ltd. Manufacturer’s Address Room 313, Unit B, Building 2,399 Danfeng Road,Xixing Subdistrict,Binjiang District,Hangzhou,Zhejiang *Except that the model number and appearance deviation, are identical with the original product as follows: Note: The definition of identical should be “electrically identical”. A device will be considered to be electrically identical if no changes are made to the devices’ schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical. with the model(s) below which samples we chose to be tested by SGS Model No. (型号): HM-TD3117T-1/Q/S Manufacturer’s Name (生产商名称): Hangzhou Microimage Software Co., Ltd. Manufacturer’s Address(生产商商地址): Room 313, Unit B, Building 2,399 Danfeng Road,Xixing Subdistrict,Binjiang District,Hangzhou,Zhejiang Sincerely, Signature (签字): Printed Name (姓名): Wen Fang Position/Title (职位): Certification Engineer Contact Number (联系电话): 18858952085
Compliance Certification Services (Kunshan) Inc. Page: 1 of 5 External Photos for KSCR2206000962AT Test Model No.: HM-TD3117T-1/Q/S Compliance Certification Services (Kunshan) Inc. Page: 2 of 5 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Page: 3 of 5 Compliance Certification Services (Kunshan) Inc. Page: 4 of 5 Compliance Certification Services (Kunshan) Inc. Page: 5 of 5
Remark:It’s hard to put FCC statement on the product due to device’s irregular appearance. FCC statement will be placed in the user manual which the device is marketed. Label location
Compliance Certification Services (Kunshan) Inc. Page: 1 of 8 Internal Photos for KSCR2206000962AT Test Model No.: HM-TD3117T-1/Q/S Compliance Certification Services (Kunshan) Inc. Page: 2 of 8 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Page: 3 of 8 Compliance Certification Services (Kunshan) Inc. Page: 4 of 8 Compliance Certification Services (Kunshan) Inc. Page: 5 of 8 Compliance Certification Services (Kunshan) Inc. Page: 6 of 8 Compliance Certification Services (Kunshan) Inc. Page: 7 of 8 Compliance Certification Services (Kunshan) Inc. Page: 8 of 8
Compliance Certification Services (Kunshan) Inc. Report No.: KSCR220600096201 Page: 1 of 20 Eric Lin EMC Laboratory Manager TEST REPORT Application No.: KSCR2206000962AT FCC ID: 2AXVM-3117T-QS IC: 26572-3117TQS Applicant: Hangzhou Microimage Software Co., Ltd. Address of Applicant: Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict,Binjiang District, Hangzhou, Zhejiang Manufacturer: Hangzhou Hikvision Digital Technology Co., Ltd Address of Manufacturer: Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict,Binjiang District, Hangzhou, Zhejiang Factory: Hangzhou Microimage Intelligent Technology Co., Ltd. Address of Factory: Floor 2, Building A1, 299 Qiushi Road, Tonglu Economic Development Zone, Tonglu County, Hangzhou City, Zhejiang Province Equipment Under Test (EUT): EUT Name: Thermographic Cube Camera Model No.: HM-TD3117T-1/Q/S,HM-TD3117T-2/Q/S Standard(s) : 47 CFR Part 15, Subpart C 15.231 RSS-210 issue 10 Amendment 1 RSS-Gen Issue 5, April 2018, Amendment 2 Date of Receipt: 2022-06-09 Date of Test: 2022-06-28 to 2022-06-28 Date of Issue: 2022-06-28 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Report No.: KSCR220600096201 Page: 2 of 20 Revision Record Version Chapter Date Modifier Remark 01 2022-06-28 Original Authorized for issue by: Eric_Liu/Project Engineer Eric Lin/Reviewer Compliance Certification Services (Kunshan) Inc. Report No.: KSCR220600096201 Page: 3 of 20 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method FCC Requirement IC Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.231 N/A 47 CFR Part 15, Subpart C 15.203 RSS-Gen Clause 6.8 Customer Declaration N/A: Not applicable Radio Spectrum Matter Part Item Standard Method FCC Requirement IC Requirement Result 20dB Bandwidth 47 CFR Part 15, Subpart C 15.231 ANSI C63.10 (2013) Section 6.9 47 CFR Part 15, Subpart C 15.231(c) RSS-210 A1.3 Pass Radiated Emissions below 1GHz ANSI C63.10 (2013) Section 6.4&6.5 47 CFR Part 15C Section 15.231(b) and 15.209 RSS-210 A1.2 Pass Dwell Time ANSI C63.10 (2013) Section 7.5 47 CFR Part 15, Subpart C 15.231(a) RSS-210 A1.1 Pass Field Strength of the Fundamental Signal ANSI C63.10 (2013) Section 6.5 47 CFR Part 15, Subpart C 15.231(b) RSS-210 A1.2 Pass Radiated Emissions above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15C Section 15.231(b) and 15.209 RSS-210 A1.2 Pass 99% Bandwidth N/A RSS-Gen Section 6.7 N/A RSS-210 A1.3 Pass Frequency Stability N/A RSS-Gen Section 6.11 N/A RSS-Gen Section 8.11 Note 1 Note 1: Frequency stability requested in RSS GEN S8.11 has been complied since the result of occupied bandwidth can demonstrate. Note 2: Declaration of EUT Family Grouping: There are series models mentioned in this report, and they are the Identical in electrical and electronic characters. Only the model HM-TD3117T-1/Q/S was tested since their differences were the model number and appearance. Compliance Certification Services (Kunshan) Inc. Report No.: KSCR220600096201 Page: 4 of 20 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 7 4.5 TEST FACILITY ...................................................................................................................................... 7 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 7 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 8 5 EQUIPMENT LIST ...................................................................................................................................... 8 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ................................................................................. 9 6.1 ANTENNA REQUIREMENT ...................................................................................................................... 9 6.1.1 Test Requirement: ......................................................................................................................... 9 6.1.2 Conclusion ..................................................................................................................................... 9 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 10 7.1 20DB BANDWIDTH .............................................................................................................................. 10 7.1.1 E.U.T. Operation .......................................................................................................................... 10 7.1.2 Test Setup Diagram ........................................................................…
Text truncated - open the document above for the full version.
Compliance Certification Services (Kunshan) Inc. 1 of 6 Appendix A for KSCR220600096201 1 Spurious Emissions 1.1 Field Strength of the Fundamental Signal Test channel Freq. (MHz) Result Level (dBμV/m) Limit Line (dBμV/m) Over Limit (dB) Detector Polarization Channel 1 433.40 71.61 100.81 -29.20 Peak Vertical 74.56 100.81 -26.25 Peak Horizontal Note: PK Field Strength is less than AV limit, so it is not necessary to test AV Field Strength. Compliance Certification Services (Kunshan) Inc. Page: 2 of 6 1.2 Spurious Emissions Below 1GHz 433.40MHz Vertical: No. Frequency Reading Correct Result Limit Margin Remark (MHz) (dBuV) Factor(dB/m) (dBuV/m) (dBuV/m) (dB) 1 40.6700 13.32 21.94 35.26 40.00 -4.74 QP 2 123.1200 10.20 19.41 29.61 43.50 -13.89 QP 3 260.8600 7.19 20.97 28.16 46.00 -17.84 QP 4 434.4900 47.62 23.99 71.61 100.81 -29.20 peak 5 743.9200 31.08 2.37 33.45 46.00 -12.55 QP 6 965.0800 30.73 2.55 33.28 54.00 -20.72 QP Compliance Certification Services (Kunshan) Inc. Page: 3 of 6 Horizontal: No. Frequency Reading Correct Result Limit Margin Remark (MHz) (dBuV) Factor(dB/m) (dBuV/m) (dBuV/m) (dB) 1 40.6700 6.22 21.94 28.16 40.00 -11.84 QP 2 132.8200 10.53 19.25 29.78 43.50 -13.72 QP 3 264.7400 9.58 20.98 30.56 46.00 -15.44 QP 4 433.5200 50.57 23.99 74.56 100.81 -26.25 peak 5 600.3600 4.36 27.06 31.42 46.00 -14.58 QP 6 679.9000 31.58 2.44 34.02 46.00 -11.98 QP Compliance Certification Services (Kunshan) Inc. Page: 4 of 6 Above 1GHz 433.40MHz Mark Frequency (MHz) Reading (dBuV) Factor (dB) Emission (dBuV/m) Limit (dBuV/m) Over Limit (dB) Detector polarization 1 1300.200 57.15 -19.64 37.51 54.00 -16.49 peak Vertical 2 1733.600 59.18 -19.39 39.79 54.00 -14.21 peak Vertical 3 2167.000 56.19 -15.14 41.05 54.00 -12.95 peak Vertical 4 1300.200 56.99 -19.64 37.35 54.00 -16.65 peak Horizontal 5 1733.600 59.03 -19.39 39.64 54.00 -14.36 peak Horizontal 6 2167.000 57.37 -15.14 42.23 54.00 -11.77 peak Horizontal 20dB Bandwidth Measurement Data: Frequency(MHz) 20dB bandwidth (kHz) Limit (kHz) Results 433.40 22.72 1083.5 Pass Test plot as follows: Compliance Certification Services (Kunshan) Inc. Page: 5 of 6 99% Bandwidth Measurement Data: 99% bandwidth (kHz) F L (MHz) F H (MHz) Limit(MHz) Result 21.9971 433.3886 433.4106 260-470 Pass Test plot as follows: Compliance Certification Services (Kunshan) Inc. Page: 6 of 6 2 Dwell Time Measurement Data: Test item Limit (s) Results Transmission Duration ≤5s Pass Test plot as follows:
Compliance Certification Services (Kunshan) Inc. Page: 1 of 2 Appendix Photographs of Test Setup for KSCR2206000962AT Test Model No.: HM-TD3117T-1/Q/S Compliance Certification Services (Kunshan) Inc. Page: 2 of 2 Test Setup Photo Radiated Emissions below 1GHz Radiated Emissions above 1GHz
588 West Jindu Road, Xinqiao, Songjiang · ShangHai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.1 MHz - 433.7 MHz | - |

Handheld Thermography Camera
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Handheld Thermography Camera
Equipment Class
DTS - Digital Transmission System
Thermal Monocular/Thermal Telescope
Equipment Class
DTS - Digital Transmission System
Thermographic Cube Camera
Equipment Class
DTS - Digital Transmission System
Thermal lmage Scope/Thermal Monocular
Equipment Class
DTS - Digital Transmission System