FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TraceSafe Technologies Inc/
  3. 2AXYO-TCCT

2AXYO-TCCTTracelet

TraceSafe Technologies Inc
Tracelet - FCC ID 2AXYO-TCCT - TraceSafe Technologies Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 01, 2021
Application Purpose
Original Equipment
Date of Application
Jul 30, 2021
Equipment Note
Tracelet
Frequency Range
2402.00000000 - 2480.00000000
Company
TraceSafe Technologies Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This is a BLE 5.0 controllabletag usedfor contacttracingand otherworkplacehealthand safetyapplications.It operateswitha CR2430coin cell battery,givesLED indicationsfor ON/OFFoperationsand Contacttracing.This hospital-grade,lightweighttag is waterproof,hypoallergenic,latex-free,and skin-friendly. Tracelet PRELIMINARY Tracelet 2 1. Features BluetoothLow Energy5.0 wirelessprotocol CompatiblewithTracesafe’s AllSafesystem 290 mAhnon rechargeablebattery LED Indicationand pushbutton Waterproof Lightweight 2. Specifications ElectricalSymbolMin.Typ.Max.UnitRemarks SupplyVoltage 3 VVdc ManganeseDioxideLithiumBattery (nonrechargeable) RFSymbolMin.Typ.Max.UnitRemarks FrequencyRange 24022480MHz TX Power 4dBm ReceiverSensitivity -91dBm EnvironmentalSymbolMin.Typ.Max.UnitRemarks OperatingTemperature tj050ºC StorageTemperature ts-2590ºC RelativeHumidityRH 2095% MechanicalSymbolMin.Typ.Max.UnitRemarks Dimensions35 x 8 mm Dia x Height Net Weight6 g In gram PRELIMINARYAllSafe2430CircularTag 3 3.DeviceDimensions Topview;CaseMaterial:PVC AllDimensionsareinmm 4.OperationsofTCCT ThetaghasanLEDwhichindicatesthestateofthetag. Initiallytagispoweredoff–LEDisnotlit. Tagispoweredonbypressingthetagbuttonfor4sec_LEDwillblinkfor30sec(Pairingtime). AfterPairingTime,beaconpacketswillbetransmitted–LEDwillnotbelit. DuringContacttracingLEDwillbeblinking. Tagmaybepowereddownbypressingbuttonfor15secwhenpowered–LEDwillfastblink3timesandturnoff. PRELIMINARYAll Safe2430CircularTag 4 5. OrderingInformation ProductCodeProductName TCCT Tracelet Version1.0 FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0mm between the radiator and your body. ISED Statement English:This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B). French: Cet appareil contient des émetteurs/récepteurs exempts de licence qui sont conformes aux RSS exemptés de licence d'Innovation, Sciences et Développement économique Canada. L'exploitation est soumise aux deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d'interférences. (2) Cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement indésirable de l'appareil. l'appareil numérique du ciem conforme canadien peut - 3 (b) / nmb - 3 (b). This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance. cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du cnr - 102 et conformité avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des données canadiennes sur l'exposition aux champs rf et la conformité. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. Cet équipement est conforme aux limites d'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. The device has been evaluated to meet general RF exposure requirement. This equipment should be installed and operated with minimum distance 0mm between the radiator and your body. L'appareil a été évalué pour répondre aux exigences générales d'exposition aux RF. Cet équipement doit être installé et utilisé avec une distance minimale de 0 mm entre le radiateur et votre corps. L'appareil a été évalué pour répondre aux exigences générales d'exposition aux RF. Cet équipement doit être installé et utilisé avec une distance minimale de 0 mm entre le radiateur et votre corps.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2021-7-29> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AXYO-TCCT TCCT For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Dennis Kwan/CEO Company: TraceSafe Technologies Inc Address: 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Phone: (949) 397-9330 Fax: (949) 397-9330 E-Mail: [email protected]

Cover Letter(s)

TraceSafe Technologies Inc 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-7-29 To whom it may concern: We, TraceSafe Technologies Inc the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AXYO-TCCT including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Dennis Kwan/CEO Company: TraceSafe Technologies Inc Address: 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Phone: (949) 397-9330 Fax: (949) 397-9330 E-Mail: [email protected]

External Photos

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 2 External Photos of the EUT Fig.1 Fig.2 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 2 Fig.3 Fig.4

ID Label/Location Info

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT _____________________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 LABEL AND LOCATION (Size: L1.5cm*W1.5cm) Material: Tagboard Glue: adhesive sticker Font color: Blue Label color: White Label Location FCC ID: 2AXYO-TCCT IC: 26632-TCCT HVIN: TCCT

Internal Photos

Shenzhen LCS Compliance Testing Laboratory Ltd FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 Internal Photos of the EUT Fig.1 Fig.2 BT Antenna Shenzhen LCS Compliance Testing Laboratory Ltd FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 Fig.3 Fig.4 Shenzhen LCS Compliance Testing Laboratory Ltd FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 Fig.5 Fig.6 Shenzhen LCS Compliance Testing Laboratory Ltd FCC ID: 2AXYO-TCCT IC: 26632-TCCT This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4 Fig.7 Fig.8

RF Exposure Info

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 FCC RF Exposure Evaluation 1. Product Information FCC ID : 2AXYO-TCCT Product name : Tracelet Test Model : TCCT Power Supply : DC 3V By CR2430 Battery Hardware Version : V1.0 Software Version : V1.0 Bluetooth : 2402-2480MHz Channel Number : 40 channels for Bluetooth V5.0 (DTS) Channel Spacing : 2MHz for Bluetooth V5.0(DTS) Modulation Type : GFSK for Bluetooth V5.0 (DTS) Bluetooth Version : V5.0 Antenna Type : Internal Antenna Antenna Gain : 0dBi Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Portable Device 2. Evaluation method and Limit According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“ [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f (GHz) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test exclusion. Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 When one of the following test exclusion conditions is satisfied for all combinations of simultaneous transmission configurations, further equipment approval is not required to incorporate transmitter modules in host devices that operate in the mixed mobile and portable host platform exposure conditions. The grantee is responsible for documenting this according to Class I permissive change requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated standalone SAR to determine simultaneous transmission test exclusion. a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration, adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0. b)The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤ 1.0. 3. Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices 4. Conducted Power Results <BT LE> Mode Channel Frequency (MHz) Peak Conducted Output Power (dBm) GFSK 0 2402 0.51 19 2440 -0.84 39 2480 0.30 5. Manufacturing Tolerance <BT LE> GFSK (Peak) Channel Channel 0 Channel 19 Channel 39 Target (dBm) 0 0 0 Tolerance ±(dB) 1.0 1.0 1.0 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT ________________________________________________________________________ ___ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 6. Evaluation Results 6.1 Standalone Evaluation Band/Mode f (GHz) Antenna Distance (mm) RF output power SAR Test Exclusion Threshold SAR Test Exclusion dBm mW BT LE GFSK 2.402 5 1.0 1.2589 0.3902< 3.0 Yes Remark: 1. Output power including tune up tolerance; 2. When the minimum …

Text truncated - open the document above for the full version.

Test Report

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 1 of 18 Appendix A RF Test Data for BT LE V5.0 (DTS) (Conducted Measurement) Product Name: Tracelet Trade Mark: tracesafe Test Model: TCCT Environmental Conditions Temperature: 21.6  C Relative Humidity: 52.7% ATM Pressure: 100.0 kPa Test Engineer: Jay Li Supervised by: Li Huan A.1 Duty Cycle TestMode Antenna Channel ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.39 0.63 0.6190 61.90 2.08 --- PASS 2440 0.38 0.62 0.6129 61.29 2.13 --- PASS 2480 0.38 0.63 0.6032 60.32 2.20 --- PASS Test Graphs BLE_1M_Ant1_2402 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 2 of 18 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 3 of 18 A.2 Maximum Conducted Peak Output Power TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 0.51 ≤30 PASS 2440 -0.84 ≤30 PASS 2480 0.3 ≤30 PASS Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 4 of 18 BLE_1M_Ant1_2480 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 5 of 18 A.3 Maximum Power Spectral Density TestMode Antenna Channel Result[dBm/3-100kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -14.61 ≤8 PASS 2440 -16.01 ≤8 PASS 2480 -14.7 ≤8 PASS Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 6 of 18 BLE_1M_Ant1_2480 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 7 of 18 A.4 6dB Bandwidth Mode Channel 6dB Bandwidth [MHz] Limit [MHz] Verdict BT LE LCH 0.6947 ≥0.5 PASS BT LE MCH 0.7027 ≥0.5 PASS BT LE HCH 0.7042 ≥0.5 PASS Test Graphs LCH MCH Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 8 of 18 HCH Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 9 of 18 B.5 Occupied Bandwidth Mode Channel Occupied Bandwidth [MHz] Verdict BT LE LCH 1.0249 PASS BT LE MCH 1.0228 PASS BT LE HCH 1.0259 PASS Test Graphs LCH MCH Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 10 of 18 HCH Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 11 of 18 A.6 RF Conducted Spurious Emissions TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -0.56 -0.56 --- PASS 30~1000 -0.56 -59.63 ≤-20.56 PASS 1000~26500 -0.56 -47.23 ≤-20.56 PASS 2440 Reference -1.79 -1.79 --- PASS 30~1000 -1.79 -59.07 ≤-21.79 PASS 1000~26500 -1.79 -47.85 ≤-21.79 PASS 2480 Reference -0.58 -0.58 --- PASS 30~1000 -0.58 -59.34 ≤-20.58 PASS 1000~26500 -0.58 -47.49 ≤-20.58 PASS Test Graphs BLE_1M_Ant1_2402_0~Reference Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 12 of 18 BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 13 of 18 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 14 of 18 BLE_1M_Ant1_2480_1000~26500 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 15 of 18 A.7 Band-edge for RF Conducted Emissions TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -0.51 -49.96 ≤-20.51 PASS High 2480 -0.49 -49.07 ≤-20.49 PASS Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 16 of 18 A.8 Restrict-band band-edge measurements TestMod e Antenna ChNam e Channel Detector Freq. [MHz] Result [dBm] Limit [dBm] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -48.32 ≤-41.20 46.88 ≤54 PASS AV 2384.210 -47.52 ≤-41.20 47.68 ≤54 PASS AV 2390.000 -47.86 ≤-41.20 47.34 ≤54 PASS Peak 2310.000 -41.63 ≤-21.20 53.57 ≤74 PASS Peak 2387.255 -39.02 ≤-21.20 56.18 ≤74 PASS Peak 2390.000 -41.27 ≤-21.20 53.93 ≤74 PASS High 2480 AV 2483.500 -47.19 ≤-41.20 48.01 ≤54 PASS AV 2494.560 -46.9 ≤-41.20 48.30 ≤54 PASS AV 2500.000 -47.58 ≤-41.20 47.62 ≤54 PASS Peak 2483.500 -40.89 ≤-21.20 54.31 ≤74 PASS Peak 2485.120 -38.67 ≤-21.20 56.53 ≤74 PASS Peak 2500.000 -41.62 ≤-21.20 53.58 ≤74 PASS Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 17 of 18 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT Page 18 of 18 BLE_1M_Ant1_High_2480_Peak

Test Report

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT Report No.: LCS210701058AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 32 FCC TEST REPORT For TraceSafe Technologies Inc Tracelet Test Model: TCCT Prepared for : TraceSafe Technologies Inc Address : 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : July 06, 2021 Number of tested samples : 2 Serial number : 210701058A-1(Engineer sample), 210701058A-2(Normal sample) Date of Test : July 06, 2021 ~ July 15, 2021 Date of Report : July 16, 2021 Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT Report No.: LCS210701058AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 32 FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCS210701058AEA Date of Issue ................................... : July 16, 2021 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards â–  Partial application of Harmonised standards â–¡ Other standard testing method â–¡ Applicant’s Name .......................... : TraceSafe Technologies Inc Address ........................................... : 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Test Specification Standard .......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Tracelet Trade Mark ...................................... : tracesafe Test Model ...................................... : TCCT Ratings ............................................ : DC 3V By CR2430 Battery Result ............................................ : Positive Compiled by: Supervised by: Approved by: Cherry Chen/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT Report No.: LCS210701058AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 32 FCC -- TEST REPORT Test Model........................... : TCCT EUT......................................... : Tracelet Applicant............................... : TraceSafe Technologies Inc Address.................................. : 401 Ryland Street, Suite 200-A, Reno, Nevada, United States 89502 Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Longjiang Circuit International Limited Address................................... : 2nd Floor, C building, Sogood technology park, Aerial road, Baoan district, Shenzhen city, China Telephone............................... : / Fax.......................................... : / Factory 1 ............................... : Longjiang Circuit International Limited Address 1............................... : 2nd Floor, C building, Sogood technology park, Aerial road, Baoan district, Shenzhen city, China Telephone............................... : / Fax.......................................... : / Factory 2................................. : LangDe Electronics Ltd Address 2................................. : Room 502, huashang industrial and trade zone, shajing 98 industrial zone, baoan district, shenzhen, China Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS210701058AEA July 16, 2021 Date of issue Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT Report No.: LCS210701058AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 32 Revision History Revision Issue Date Revisions Revised By 000 July 16, 2021 Initial Issue Gavin Liang Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT Report No.: LCS210701058AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 32 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6 1.2. HOST S…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen LCS Compliance Testing Laboratory Ltd. FCC ID: 2AXYO-TCCT IC: 26632-TCCT _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

Dennis Kwan(CEO)
[email protected]949 397 9330Fax: 949 397 9330

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from TraceSafe Technologies Inc

AllSafe Gateway - FCC ID 2AXYO-TBUDW - TraceSafe Technologies Inc
2AXYO-TBUDW

AllSafe Gateway

Mar 02, 2021

Equipment Class

DTS - Digital Transmission System
Clip Tag - FCC ID 2AXYOTTAC - TraceSafe Technologies Inc
2AXYOTTAC

Clip Tag

Dec 20, 2020

Equipment Class

DTS - Digital Transmission System