
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Date:04/17/2018VCB_F-01:OperatingProceduresForm–FCCAuthorizationv02Page1of1 ShenzhenICHECKEYTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:2022-4-6 SUBJECT:FCCApplicationfor(FCCID:2AYA5-IFORCEM1) ToWhomItMayConcern: We,theundersigned,herebyauthorizeYoyoZhouin ShenzhenHuaxiaTesting TechnologyCo.,Ltdat1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad, DalangStreet,LonghuaDistrict,Shenzhen,Chinaonourbehalf,toapplytotheFederal CommunicationsCommissiononourequipment.Anyandallactscarriedoutby ShenzhenHuaxiaTestingTechnologyCo.,Ltd onourbehalfshallhavethesame effectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We, theapplicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection 5301oftheAnti-DrugActof1988,21USC853a,andnopartytotheapplicationis subjecttoadenialoffederalbenefitspursuanttothatsection. Sincerely, (MustbesignedbythepersonthatislistedontheFCCWebsite) Signature: Contactname:Huolin.Xie Companyname:ShenzhenICHECKEYTechnologyCo.,Ltd. Address:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,BantianStreet,LongGangDistrict, ShenzhenChina.518000
Date:04/17/2018VCB_F-01:OperatingProceduresForm–FCCConfidentialityv02Page1of1 ShenzhenICHECKEYTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2AYA5- IFORCEM1 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequest confidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName 1.BlockDiagram, 2.Schematics, 3.OperationalDescription 1.2AYA5-IFORCEM1-Blockdiagram 2.2AYA5-IFORCEM1-SCH 3.2AYA5-IFORCEM1-Operationaldescription Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsmaybeharmfultothe applicantandprovideunjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateofthe Grantforthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealso requesttemporaryconfidentialtreatmentofinformationaccompanyingthisapplication asoutlinedbelowforaninitialperiodofxxxx(ie-“45”,“90”or“180”)days: ExhibitTypeFileName N/AN/A Signature: Contactname:Huolin.Xie Companyname:ShenzhenICHECKEYTechnologyCo.,Ltd. Address: B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,BantianStreet, LongGangDistrict,ShenzhenChina.518000
FCC ID:2AYA5-IFORCEM1 Externalphotos FCC ID:2AYA5-IFORCEM1
FCC ID:2AYA5-IFORCEM1 Internalphotos FCC ID:2AYA5-IFORCEM1
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothesample(s) tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.: CQASZ20220400505E-02 Applicant:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofApplicant:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,Bantian Street,LongGangDistrict,ShenzhenChina.518000 EquipmentUnderTest(EUT): Product:MAGNETICWIRELESSCARCHARGER ModelNo.:iFORCEM1 TestModelNo.:iFORCEM1 BrandName:N/A FCCID:2AYA5-IFORCEM1 Standards:47CFRPart1.1307 47CFRPart1.1310 KDB680106D01RFExposureWirelessChargingBaseAppv03r01 DateofReceipt:2022-4-1 DateofTest:2022-4-1to2022-4-14 DateofIssue: 2022-4-22 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (TimoLei) ReviewedBy: (RockHuang) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-02 Page:2of10 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20220400505E-02Rev.01 Initialreport 2022-4-22 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-02 Page:3of10 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD...........................................................................................4 3.4TESTENVIRONMENT......................................................................................................................................................5 3.5DESCRIPTIONOFSUPPORTUNITS..................................................................................................................................5 3.6TESTLOCATION.............................................................................................................................................................6 3.7TESTFACILITY...............................................................................................................................................................6 3.8EQUIPMENTLIST............................................................................................................................................................6 4RFEXPOSUREEVALUATION.......................................................................................................................................7 4.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................7 4.1.1Limits....................................................................................................................................................................7 4.1.2TestProcedure...................................................................................................................................................7 4.1.3TestSetup...........................................................................................................................................................8 4.1.4TestResults........................................................................................................................................................8 APPENDIXA:PHOTOGRAPHSOFTESTSETUP.....................................................................................................10 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-02 Page:4of10 3GeneralInformation 3.1ClientInformation Applicant:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofApplicant:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,Bantian Street,LongGangDistrict,ShenzhenChina.518000 Manufacturer:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofManufacturer:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,Bantian Street,LongGangDistrict,ShenzhenChina.518000 Factory:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofFactory:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,Bantian Street,LongGangDistrict,ShenzhenChina.518000 3.2GeneralDescriptionofEUT ProductName: MAGNETICWIRELESSCARCHARGER ModelNo.: iFORCEM1 TestModelNo.: iFORCEM1 BrandName: N/A SoftwareVersion: V1.0 HardwareVersion: V1.0 PowerSupply: DC5V,9V,12V/2A(max) 3.3ProductSpecificationsubjectivetothisstandard EquipmentCategory:Non-ISMfrequency OperationFrequencyrange:110kHz~205kHz ModulationType:Induction AntennaType:Inductioncoil AntennaGain:0dBi Note: 1.Insection15.31(m),regardstotheoperatingfrequencyrangeless1MHz. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-02 Page:5of10 3.4TestEnvironment OperatingEnvironment: Temperature: 25.5  C Humidity:53%RH AtmosphericPressure:1009mbar TestMode: Modea:KeeptheEUTatNormalWorking 3.5DescriptionofSupportUnits T…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20220400505E-01 Applicant:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofApplicant:B302,Building4,TianYanXuan,No.1Lane14,BantianEastVillage,Bantian Street,LongGangDistrict,ShenzhenChina.518000 EquipmentUnderTest(EUT): Product:MAGNETICWIRELESSCARCHARGER ModelNo.:iFORCEM1 TestModelNo.:iFORCEM1 BrandName:N/A FCCID:2AYA5-IFORCEM1 Standards:47CFRPart15,SubpartC DateofReceipt:2022-4-1 DateofTest:2022-4-1to2022-4-14 DateofIssue: 2022-4-22 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (TimoLei) ReviewedBy: (RockHuang) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-01 Page: 2 of 25 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20220400505E-01Rev.01 Initialreport 2022-4-22 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-01 Page: 3 of 25 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203 ANSIC63.102013PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSIC63.102013PASS 20dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.215 ANSIC63.102013PASS RadiatedEmission, RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.209 ANSIC63.102013PASS ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-01 Page: 4 of 25 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3PRODUCTSPECIFICATIONSUBJECTIVETOTHISSTANDARD........................................................................................5 4.4TESTENVIRONMENT...................................................................................................................................................6 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................6 4.6STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................7 4.7TESTLOCATION..........................................................................................................................................................7 4.8TESTFACILITY............................................................................................................................................................7 4.9DEVIATIONFROMSTANDARDS....................................................................................................................................7 4.10OTHERINFORMATIONREQUESTEDBYTHECUSTOMER............................................................................................7 4.11EQUIPMENTLIST.......................................................................................................................................................8 5TESTRESULTSANDMEASUREMENTDATA.......................................................................................................9 5.1ANTENNAREQUIREMENT............................................................................................................................................9 5.2CONDUCTEDEMISSIONS............................................................................................................................................10 5.320DBOCCUPYBANDWIDTH......................................................................................................................................13 5.4RADIATEDSPURIOUSEMISSION&RESTRICTEDBANDS...........................................................................................15 5.4.1SpuriousEmissions......................................................................................................................................15 6PHOTOGRAPHS-EUTTESTSETUP.....................................................................................................................20 6.1RADIATEDEMISSION.................................................................................................................................................20 6.2CONDUCTEDEMISSION..............................................................................................................................................21 7PHOTOGRAPHS-EUTCONSTRUCTIONALDETAILS......................................................................................22 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20220400505E-01 Page: 5 of 25 4GeneralInformation 4.1ClientInformation Applicant:ShenzhenICHECKEYTechnologyCo.,Ltd. AddressofApplicant:B302,Buil…
Text truncated - open the document above for the full version.
FCC ID:2AYA5-IFORCEM1 1Photographs-EUTTestSetup 1.1RadiatedEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID:2AYA5-IFORCEM1 1.2 ConductedEmission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

2 in 1 Foldable Magnetic Wireless Charger Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
T15 2 in 1 Foldable Magnetic Wireless Charger Stand
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzM6 Magnetic Car Mount Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzM6 Magnetic Car Mount Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
3 in 1 Foldable Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz