
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
产品说明书 Intelligent lock cylinder Product manual APP+密码+刷卡+机械磁感钥匙开锁 APP+ password+ ICcard + Emergency micro magnetic induction key 型号(MODEL):C36 Smartlockinstructions 1.AddaBluetoothadministrator Theadministrator'sdoorlockwasnotadded,In thecasewherethebacklightisoff.Openthe Lionshousekeeper(TTLOCK)APPfirst.Click the+signtoaddalock.Selecttheappropriate lock.(Ifthereisnolockavailableinthe correspondinglock,pleaseselectthelock), Accordingtotheprompt,theuserusesthebutton towakeupthedoorlock,clickNext,selectthe correspondinglockinthenearbylock,clickthe+ sign,thennamethedoorlock,clickNext,the Bluetoothadministratoraddssuccessfully. (Addinganadministratorrequiresthephoneto turnonBluetoothandlocationinformation) 1,Settheadministratorpassword TheuserselectsSettings-AdministratorUnlock Password-Password-enters4-9digitsonthe Appandthenconfirmsthattheadministrator passwordhasbeensuccessfullymodified. 2,addICcard Aftertheuserselectthe"AddICCard"functionon theApp.Themobileappprompts"Pleaseswipe". Aftertheuserswipesthecardandrecognizesit,it prompts“EnterSuccessfully”. 3,passwordtoopenthedoor wakesup,theuserentersthecorrectdooropen passwordandpresseskey Ifthepasswordverificationissuccessful,thedoor lockdisplaysabluelightandunlocksthelock. Ifthepasswordhasexpired,thedoorlock displaysaredlight.Unlockingfailed. Ifyouenterthewrongpassword5timesinarow. Thesystemislockedandreleasedafter5 minutes. 4,ICcardtoopenthedoor Aftertheuserswipethecard.iftheICcardis recognizedandisvalid.Thedoorlockdisplaysa bluelightandunlocksthelock. Ifithasexpiredorisnotineffect.Thenthedoor lockshowsaredlight.Unlockingfailed IftheICcarddoesnotexist,thedoorlockdisplays aredlight.Unlockingfailed 5,Unlock Thisdoorlockwillautomaticallyclosethelock5 secondsafterthelockisunlocked. 6,modifytheusertoopenthepassword Permanent,time-limitedorcustompasswords obtainedbytheusercanbeused(password needstobeunlockedonce) Digitalpanelinput10originalpassword newpasswordnewpasswordThenew passwordtakeseffect. 7,lowelectricityreminder Whenthepowerislow,theusertouchesthe buttontowakeupthedoorlock.Aredlight indicates“Thebatteryislow.Pleasereplacethe battery”andtheredlightonthescreenbacklight flashesrapidlyfor1second. 8,keyboardlock Whenthenumberofinputpassworderrors reaches5times.Thelockprompt"Illegal operation,thesystemislocked".Lockthe passwordkeyboardfor5minutesatthesame time.Thebacklightflashesonce.Indicatesthat thecurrentkeyboardislocked. Whilethekeyboardislocked,theICcardandthe Appcanopenthedoornormally,andthe passwordkeyboardwillbeunlockedafterthedoor isopened. 9.DeletetheBluetoothadministrator. Method1:Theuserfindsthecorrespondinglock onthesideofthedoorlock.Entersthe correspondinglocksetting,anddeletesthe administratorkey. Lionshousekeeper(TTLOCK)APPoperation method KeymanagementherereferstoBluetoothkey management.Aftertheadministratorsuccessfully addedthelock.Willhavethehighest administrativerightstothelock.Hecansendkeys toothers.Andspecifythetimelimit,choosethe limitedtime,permanentorsingleBluetoothkey permissions. Increasethekeymanagementthatisaboutto expire,thatis,theexpirationkeyreminder. Clickingonthekeytypewillappear:time-limited key,permanentkeyandsingle-time;select "time-limitedkey",itwillbevalidwithinthe specifiedtime;select"permanentkey",itwillbe permanent;select"single",thenusesinglekey onceAutomaticallydelete. 1.1Singlepasswordfunction Thekeysentfromthehousekeeperversioncan havethefunctionofobtainingasinglepassword. 1.2KeyManagement Administratorscanmanageallthekeystheysend out.Thisincludesclearingthekey,resettingthe key,sendingthekey,adjustingthekeyexpiration date,andviewingtheunlockingrecordofthekey. 1.3keyexpirationreminder Forthekeythatisabouttoexpire,itwillexpirein thelockuser(yellowshowstheremainingdays) andexpiredreminder(redscript). 1.4Queryingtheunlockrecord Theadministratorcanquerytheunlockrecordof eachkey. 2.Passwordmanagement Passwordsarealsoawaytounlockthem.After enteringthepasswordonthelock'skeyboard. Presstheunlockbuttoninthelowerrightcornerto unlock.Passwordsareclassifiedintopermanent, time-limited,single-time,empty,loop,custom, etc.,alldynamicallygeneratedbytheserver. 2.1Permanentpassword Apermanentpasswordreferstoapasswordthat hasbeenavailablefromnowon.Thepassword mustbeusedwithin24hoursofbeinggenerated, otherwiseitwillautomaticallyexpire. 2.2Time-limitedpassword Thetime-limitedpasswordcanbesettothe expirationdate,whichisaminimumofonehour andamaximumofthreeyears.Ifthevalidity periodiswithinoneyear,thetimecanbeaccurate tothehour;ifthevalidityperiodismorethanone year,theaccuracyismonth.Afterthetime-limited passwordisvalid,itwillbeusedwithin24hours, otherwiseitwillautomaticallyexpire. Afterenteringthepasswordonthelock,pressthe unlockbuttonor#buttoninthelowerrightcorner ofthekeyboardtounlock. Passwordmodificationmethod:Afterinputtingthe originalpasswordtounlock,input10old passwordnewpasswordnewpassword Thenewpasswordtakeseffect. 2.3Singlepassword Asinglepasswordcanonlybeusedonceandis validfor6hours. 2.4Clearcode Theclearcodeisusedtodeleteallpasswords usedonthelockandisvalidfor24hours. 2.5cyclepassword Thelooppasswordcanbereusedwithina specifiedtimeinterval,withdailyloops,weekday loops,weekendloops,andmore. 2.6CustomPassword Thefirstfewtypesofpasswordsaredynamically generatedbytheserver.Custompasswordsallow theusertoenterthedesiredpasswordandsetthe desiredexpirationdate. 2.7Sharingpasswords InadditiontothecommonlyusedWeChat,SMS andemailsharingmethods,FacebookMessenger andWhatsapphavealsobeenaddedtofacilitate foreigncustomers. 2.8ViewingandManagingPasswords Allgeneratedpasswordscanbeviewedand managedinthepasswordmanagementmodule. Thisincludeschangingthepassword,deletingthe password,resettingthepassword,andunlocking thepassword. 3.CardManagement SupportforopeningthedoorthroughvariousIC cards.BeforeanICcardisusedtoopenthedoor, youneedtoadditfirst.Theadditionprocess needstobedonebytheappnexttothelock.The validityperiodoftheICcanbeset,either permanentortime-limited.Afterthesettingis completed,youcanalsomodifyitsvalidityperiod. 3.1…
Text truncated - open the document above for the full version.
ZHEJIANG BAlMA LOCK CO., LTD 1/1 Letter of Authorization Company: ZHEJIANG BAlMA LOCK CO., LTD Address: Pudong lndustrial Area, Pujiang, Zhejiang, China Product Name: Smart lock cylinder Model Number: C36 FCC Identifier: 2AYAQ-C36 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Yongkui Xu Date: 2020-11-25 Title: Manager Signature of applicant:
ZHEJIANG BAlMA LOCK CO., LTD 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-11-25 Subject: Request for Confidentiality FCC ID: 2AYAQ-C36 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yongkui Xu Title: Manager
Model: C36
Size:15*10mm M/N: C36 FCC ID: 2AYAQ-C36 Label location
Model: C36 antenna location
Global United Technology Services Co., Ltd. Report No.: GTSL202011000208 Authorized Signature: Robinson Lo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 27 + TEST REPORT Applicant: ZHEJIANG BAlMA LOCK CO., LTD Address of Applicant: Pudong lndustrial Area, Pujiang, Zhejiang, China Manufacturer: ZHEJIANG BAlMA LOCK CO., LTD Address of Manufacturer: Pudong lndustrial Area, Pujiang, Zhejiang, China Equipment Under Test (EUT) Product Name: Smart lock cylinder Model No.: C36 Trade Mark: N/A FCC ID: 2AYAQ-C36 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.249 Date of sample receipt: Nov. 20, 2020 Date of Test: Nov. 20, 2020 - Nov. 25, 2020 Date of report issued: Nov. 25, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTSL202011000208 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 27 2 Version Version No. Date Description 00 Nov. 25, 2020 Original Prepared By: Date: Nov. 25, 2020 Project Engineer Check By: Date: Nov. 25, 2020 Reviewer Report No.: GTSL202011000208 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 27 3 Contents Page 1 COVER PAGE .............................................................................................................................................1 2 VERSION ...................................................................................................................................................2 3 CONTENTS ...............................................................................................................................................3 4 TEST SUMMARY ......................................................................................................................................4 4.1 MEASUREMENT UNCERTAINTY .............................................................................................................4 5 GENERAL INFORMATION .......................................................................................................................5 5.1 GENERAL DESCRIPTION OF EUT ..........................................................................................................5 5.2 TEST MODE .........................................................................................................................................7 5.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................................7 5.4 DEVIATION FROM STANDARDS ..............................................................................................................7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................7 5.6 TEST FACILITY ....................................................................................................................................8 5.7 TEST LOCATION ..................................................................................................................................8 5.8 ADDITIONAL INSTRUCTIONS ..................................................................................................................8 6 TEST INSTRUMENTS LIST ......................................................................................................................9 7 TEST RESULTS AND MEASUREMENT DATA .....................................................................................11 7.1 ANTENNA REQUIREMENT ....................................................................................................................11 7.2 CONDUCTED EMISSIONS ....................................................................................................................12 7.3 RADIATED EMISSION METHOD ............................................................................................................13 7.3.1 Field Strength of The Fundamental Signal ..................................................................................15 7.3.2 Spurious emissions .....................................................................................................................16 7.3.3 Bandedge emissions ...................................................................................................................21 7.4 20DB OCCUPY BANDWIDTH ...............................................................................................................22 8 TEST SETUP PHOTO .............................................................................................................................24 9 EUT CONSTRUCTIONAL DETAILS .......................................................................................................25 Report No.: GTSL202011000208 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 27 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203 Pass AC Power Line Conducted Emission 15.207 N/A Field strength of the fundamental signal 15.249 (a) Pass Spurious emissions 15.249 (a) (d)/15.209 Pass Band edge 15.249 (d)/15.205 Pass 20dB Occupied Bandwidth 15.215 …
Text truncated - open the document above for the full version.
Radiated Emission Model: C36
Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Smart Key Box
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart Traffic lock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart padlock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart padlock
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter