Wi Fi Digital Microscope U ser Manual V1.0 M ode : CM2 P lease read the instructions carefully and keep it for future reference. Contents 03 04 04 04 05 05 06 07 07 08 08 09 11 11 12 13 14 15 Read me First Installation Instructions Packing list Installation of microscope Parts Description Parts and functions Battery installation Detailed Operation 1. How to focus? 2. How to work with PC? Software download Operating steps 3. How to work with cell phone? App download Operating steps Introduction of the APP Usage Environment Description Product Parameters Read me First • Please read this user manual carefully and keep it for future reference. • When placing items, place them directly below the center of the lens as much as possible. Avoid not seeing objects clearly and bringing about a bad experience. • Please store the microscope in a cool and dry place and avoid direct sunlight. • Please avoid storing the microscope in places where there is risk of falling, which may cause the internal lenses to deviate or damage other components, as well as other irreparable damage. • The microscope can be used in hand or inserted as a desktop, with attention to avoid damage to the components. • Pay attention to protect the lens part. Close the lens lid after using to avoid entering dust or strange objects. — 03 — Installation Instructions Microscope Base Packing list Installation of microscope — 04 — 1. Take off the microscope lens cover. 2. Hold the base with one hand and insert the microscope vertically into the installation hole. 3. Complete (Note: Please adjust until the focus wheel is fully exposed) Parts Description Parts and functions — 05 — Full Light Bright Button Full Light Dim Button Focus Wheel Lens Cap Bright and turn on the Ŕêêê×ÏÔē ×ð©ò½ēęĈòøÍÍēÔÂŔêê light. Rotate the wheel to focus the observed object. Please keep ēÔÂøμä·ē½×Čē©ò·ÂŔὩò½ slowly adjust the wheel until the picture is clear. Protect the lens Microscope Base Base Light Adjustment Knob Adjustable Knob. Specimen Fixation Clamp Observation Window Fixed Observation Device for Microscope Stand. Adjustable Movement of Microscope for Up and Down. Rotate the knob to adjust the brightness of the base light. ·ê©ðĄÍøĈŔį×òÏ specimens or observing targets. Render the bottom of the object for observation. Note: When the device is abnormal, long press the "Full Light Bright Button" and "Full Light Dim Button" at the same time to forcibly shut down the device. — 06 — Power Button Charging Indicator light Type-C Interface Long press it for 3 seconds to to turn on/off the microscope. Connect type-c to charge or connect with computer. Note: During the charging process, if the outer shell of the microscope has slight heating, it is a normal phenomenon, Ąê©ČÂęČÂ×ēĪ×ēÔ·øòŔ½Âò·ÂȒ You can charge the microscope with your daily mobile charger, computer, or power bank. Please do not charge it for more than 12 hours to avoid affecting the battery life. Battery installation The indicator light is μêęÂê×ÏÔēŕ©ČÔÂČ©ÍēÂĈ power on, when connect to computer/WiFi, the indicator light is always blue; The indicator light is red after charging, when full, the light is off; When the battery is êøĪȓēÔÂμêęÂê×ÏÔēŕ©ČÔÂČ for 30s and then turns off automatically. Step 2. Install the 7# 1.5V battery according to the direction indicated inside (please pay attention to distinguish the positive and negative poles when installing the battery, the non-rechargeable battery can not be charged ) Step 1. Pry open the battery cover of the base by buckling the battery cover recess Step 3. Close the battery cover. džȒ,øĪēøÍø·ęČɄ — 07 — * Before using the microscope, please make sure to hold it steady with your hands or place it on the desk for use. Detailed Operation Counter-Clockwise Rotation: ðęêēץêÂð©Ïò×Ŕ·©ē×øò Clockwise Rotation: multiple reduction ( Note: In case of any other problems, the reset hole will restore the factory setting. At the same distance, the Ĉøē©ē×òÏĶøøð·İê×ò½ÂĈÔ©ČēĪøð©Ïò×Ŕ·©ē×øòȒhø©½äęČē more multiples, it can be adjusted up and down through the microscope base bracket. ) — 08 — 2. How to work with PC? Software download Note: The following 3 methods can be downloaded, please choose the appropriate version according to your computer system. For Windows 7, Windows 8.1, Windows 10, Windows 11 and Mac , download the software from the website: For Windows 8 or higher system, search "hiView" (” ”)in the Microsoft Store to download it and you can also be viewed in Camera(” ”). For Mac OS X 12 or higher system, search "hiView" in the APP Store to download it and you can also be viewed in Photo Booth(“ ”) . http://soft.hvscam.com Operating steps Step 1: Connect CM2 microscope to computer through the Type-C cable. Step 3: Open the software, you can see the image and take pictures and videos through the software. HiView (Window System) — 09 — Step 2: Long press Power Button for 3 seconds to turn on the ð×·ĈøČ·øĄÂȒɑGøēÂȔÔÂòēÔÂ×ò½×·©ēøĈê×ÏÔē×Čŕ©ČÔ×òÏȓ the microscope is powered on. ) —10 — Windows Camera Photo Booth (Mac) — 11 — 3. How to work with cell phone? App download Operating steps Use mobile phone/tablet browser to scan the QR code, click ½øĪòêø©½©ò½×òČē©êêʃGøēÂȺFor iOS system, search for "DLscope" ×òēÔÂĄĄaēøĈ©ò½½øĪòêø©½ʄ (iOS / Android download \]·ø½Âʄ (iOS / Android icon) aēÂĄdžȺTurn on the microscope Long press power button for 3 seconds to to turn on the ð×·ĈøČ·øĄÂȒɑGøēÂȔÔÂòēÔÂ×ò½×·©ēøĈê×ÏÔē×ČμêęÂŕ©ČÔ×òÏȓ WiFi is ready to be connected.) aēÂĄLJȺConnect microscope to cell phone. Connect microscope to Android / IOS — 12 — open DLscope, click "+" in the upper right corner to select the device "CM2", select the WiFi name corresponding to the product: "Cam-CM2-xxxx" (no password ) . After connected, return to the APP and click to enter. When connected, the indicator light is blue and you can use "DLscope" . — 13 — Introduction of the APP ( * The picture…
Text truncated - open the document above for the full version.
C5266091_X24_Ed.2 1/1 “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Microlong Technology Co., Ltd Grantee code: 2AYBY FCC ID: 2AYBY-CM2 Contact Name: chenguojun Address: 4 Floor, Building E,131 Bulan Road, Nanwan Street, Longgang Dirtrict, Shenzhen City, Guangdong Province, China Telephone No: 0755-28717659 Fax No: / Email: [email protected] i. [Shenzhen Microlong Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Microlong Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Microlong Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment. Date: 2023/06/17 Applicant’s Name: chenguojun Title: Engineer Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
C5266091_X8_Ed.1 1/1 LetterofAuthorization <ShenzhenMicrolongTechnologyCo.,Ltd> Company:ShenzhenMicrolongTechnologyCo.,Ltd Address:4Floor,BuildingE,131BulanRoad,NanwanStreet,LonggangDirtrict, ShenzhenCity,GuangdongProvince,China ProductName:Digitalmicroscop ModelNumber:CM2 FCCIdentifier:2AYBY-CM2 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:chenguojunDate:2023-6-17 Title:Engineer Signatureofapplicant:
C5266091_X10_Ed.2 1/1 <ShenzhenMicrolongTechnologyCo.,Ltd> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date: Subject:RequestforConfidentiality FCCID:2AYBY-CM2 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:chenguojun Title:Engineer
ExternalPhotos
FCCID:2AYBY-CM2 Thisdevicecomplieswithpart15oftheFCCRules.Operationis subjecttothefollowingtwoconditions:(1)thisdevicemaynot causeharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.
※※※※※ENDOFREPORT※※※※※
FCC ID: 2AYBY-CM2 RF ExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093, UnlessspecificallyrequiredbythepublishedRF exposureKDBprocedures, standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,is notrequiredwhenthe correspondingSARTest ExclusionThresholdcondition(s),listedbelow,is (are)satisfied. For100MHzto6 GHzandtestseparationdistances≤ 50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/ (min.testseparationdistance, mm)]· [√f (GHz) ] ≤ 3.0for1-gSAR,and≤ 7.5for10-gextremitySAR,where f (GHz) is theRFchanneltransmitfrequencyin GHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultis roundedtoonedecimalplaceforcomparison Here, ForWIFI MaxPower(dBm)MaxPower(mW)Frequency(MHz)Min.distance(mm)Calc.thresholdslimit 4.52.81824375 0.880 3.0 Soa SARtestis notrequired
BSL TestingCo.,LTD.ProjectNo.: BSL2305318275006F Page 1 of 63 FCCPART15C Measurementand Test Report For ShenzhenMicrolongTechnologyCo., Ltd FCCID:2 AYBY-CM2 FCC Rule(s)/Methods: FCCCFR Title 47 Part 15 SubpartC Section15.247 ANSIC63.10:2013 ProductDescription: Digitalmicroscop Trademark / Model/Typereference.: CM2 ReportNo.:BSL2305318275006F Date of receiptof test item:May 25 , 202 3 Date of sampling:May 25 , 202 3 TestedDate:May 25 , 202 3 to June25, 2023 IssuedDate:June25, 2023 TestedBy: CindyZheng/Engineer ReviewedBy: HaleyWen/EMCManager Approved& AuthorizedBy: MikeMo / PSQManager BSL TestingCo.,LTD. 1/F, BuildingB, XinshidaiGR Park,ShiyanStreet,Bao'anDistrict,Shenzhen,Shiyan Street,Bao'anDistrict,Shenzhen,Guangdong,518052,People’s Republicof China Tel: 400-882-9628Fax: 86- 755-26508703 BSL TestingCo.,LTD.ProjectNo.: BSL2305318275006F Page 2 of 63 Table of Contents Page 1. VERSION.....................................................................................................................4 2. SUMMARYOF TEST RESULTS..................................................................................5 2.1 TEST FACILITY....................................................................................................................6 2.2 MEASUREMENTUNCERTAINTY.......................................................................................6 3. GENERALINFORMATION..........................................................................................7 3.1 GENERALDESCRIPTIONOF EUT ....................................................................................7 3.2 DESCRIPTIONOF TEST MODES......................................................................................8 3.3 BLOCKDIGRAMSHOWINGTHE CONFIGURATIONOF SYSTEMTESTED.................8 3.4 DESCRIPTIONOF SUPPORTUNITS(CONDUCTEDMODE)...........................................9 3.5 EQUIPMENTSLIST FOR ALL TEST ITEMS.....................................................................10 4. EMC EMISSIONTEST ...............................................................................................10 4.1 CONDUCTEDEMISSIONMEASUREMENT....................................................................12 4.1.1 POWERLINE CONDUCTEDEMISSIONLimits.....................................................12 4.1.2 TEST PROCEDURE..................................................................................................12 4.1.3 DEVIATIONFROMTEST STANDARD.....................................................................12 4.1.4 TEST SETUP.............................................................................................................13 4.1.5 EUT OPERATINGCONDITIONS..............................................................................13 4.1.6 TEST RESULT...........................................................................................................14 4.2 RADIATEDEMISSIONMEASUREMENT.........................................................................16 4.2.1 RADIATEDEMISSIONLIMITS.................................................................................16 4.2.2 TEST PROCEDURE..................................................................................................16 4.2.3 DEVIATIONFROMTEST STANDARD.....................................................................17 4.2.4 TEST SETUP.............................................................................................................17 4.2.5 EUT OPERATINGCONDITIONS..............................................................................18 4.2.6 TEST RESULTS.........................................................................................................18 5. RADIATEDBANDEMISSIONMEASUREMENT........................................................27 5.1 TEST REQUIREMENT:......................................................................................................27 5.2 TEST PROCEDURE..........................................................................................................27 5.3 DEVIATIONFROMTEST STANDARD.............................................................................27 5.4 TEST SETUP......................................................................................................................28 5.5 EUT OPERATINGCONDITIONS......................................................................................28 5.6 TEST RESULT....................................................................................................................29 6. POWERSPECTRALDENSITYTEST ........................................................................31 6.1 APPLIEDPROCEDURES/ LIMIT .....................................................................................31 6.2 TEST PROCEDURE..........................................................................................................31 6.3 DEVIATIONFROMSTANDARD.......................................................................................31 6.4 TEST SETUP......................................................................................................................31 6.5 EUT OPERATIONCONDITIONS......................................................................................31 BSL TestingCo.,LTD.ProjectNo.: BSL2305318275006F Page 3 of 63 6.6 TEST RESULT....................................................................................................................32 7. CHANNELBANDWIDTH& 99% OCCUPYBANDWIDTH.........................................37 7.1 APPLIEDPROCEDURES/ LIMIT .....................................................................................37 7.2 TEST PROCEDURE..........................................................................................................37 7.3 DEVIATIONFROMSTANDARD.......................................................................................37 7.4 TEST SETUP.........................................................................................…
Text truncated - open the document above for the full version.
2.4GhzWIFIRF PCBOnboardAntenna Applications *Bluetooth/WirelessLAN/HomeRF *ISMband2.4GHzApplications Specifications Frequency:2400MHz--2500MHz Applicationequipment:2.4GIEEE802.11b/gEquipment Gain:1.5dBi Radiationtype:omni-directional Impedance:50Ohm VSWR:<2.0 Polarizationmode:Verticalandhorizontal Length:30.2mm(12.8x5.3mm) OperatingTemperatureRange:-40--+85° Shenzhen Microlong Technology Co., Ltd Model No AX1 :
EUTTESTPHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 48.98 mW |

Digital microscope
Equipment Class
DTS - Digital Transmission System