Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USB Receiver with Antenna Remote Lanyard comes unattached Installation Straighten the Merlyn USB DongleSee page 2 Connect the USB Receiver to the Android USB3.0 port on the bottom side of the rear of the panel. Front of panel Make sure that the antenna is pointing down and there is a clear line of sight from the antenna to the RCU. Ports on bottom side of Q23 panel Audio Line Out Android USB3.0 Audio SPDIF HDMIEthernet Out Ethernet In RS22Line Out Public USB3.0 Android USB3.0 SPDIF Out HDMI Out Ports on bottom side of Q21 panel What’s in the box 1. USB Receiver with Antenna Safety Certifications User Guide Two AA Batteries Press the Push-to-Talk button ( ) and then hold it down while you talk to Merlyn. Try some voice requests: Not sure if Merlyn is running? Get started using Merlyn Try holding down the Push-to-Talk button ( ) and asking, “How’s the weather?” If you hear a response, then Merlyn is ready to use! If you don’t get a response, try pressing the orange Merlyn Menu button toward the top of the remote to see notifications that will guide you to finish setup. If you do not see the Merlyn toolbar or notifications in the top right of your screen when you click the button, please click “apps” on your panel home screen and looking for an app called “Merlyn.” If you see it, click the app to start it. If it is not there, please contact your IT Administrator for help. Before using the remote control, ensure the batteries are loaded and pull tab has been removed. Merlyn Display Software Management Before downloading the software, your district will need to purchase Merlyn Display licenses from an authorized vendor. After purchasing the licenses, your district will gain access to the Management Console to register your panels and manage your software. This step should occur before you download the software to the panel. Console Merlyn Display App The Merlyn Display software can be downloaded from the Newline App store on your panel. Depending on access settings, your display may require administrator approval to download the software. After downloading the software, the Merlyn Display App will present you with a QR code to register in the Management Console. This is required to enable the software on the display. Ask questions “What time is it?” “Who is George Washington?” “How many cups are in a pint?” Open and search websites “Open YouTube” “Search Google for the Pythagorean Theorem” “Open Khan Academy” “Search Newsela for California” Control your panel and panel apps “Start a timer for 2 minutes“ “Open whiteboard / Close whiteboard“ “Switch to HDMI1” “Increase brightness” “Volume up” “Freeze screen“ RF427D VER: 01 Push-to-Talk Merlyn Menu This code will take you to the Merlyn Display Support page. There, you can find guides for installation, Remote control usage, how to get started, and support when you need it. merlyn.org/startdisplay [email protected] merlynmind.ai/support Remote Control Quick Start Guide Merlyn USB Dongle HVIN: MUDG3 FCCID2AYDX-MUDG3 IC26781-MUDG3 ISED STATEMENTS/DÉCLARATION ISED This device contains licence-exempt transmitter(s)/receiver(s) that complywith Innovation,Science and Economic DevelopmentCanada's licence-exempt RSS(s).Operation is subject to the following two conditions: (1)This device may not cause interference. (2)This device must accept any interference,including interference thatmay cause undesired operation of the device This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment Lémetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation,Sciences et Développement économique Canada applicables aux appareils radioexempts de licence.Lexploitation est autorisée aux deux conditions suivantes: (1)Lappareil ne doit pas produire de brouillage; (2)Lappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC STATEMENT This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)this device may not cause harmful interference,and(2)this device must accept any interferencereceived,including interference that may cause undesired operation. CAUTION:Changesor modifications not expressly approved by the party responsible for compliancecould void the user's authority to operate the equipment If this equipment doescause harmful interference to radio or television reception,which can be determined by turning the equipment offand on,the user is encouraged totry to correct NOTE:Thisequipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses,and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installation. the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna ·Increase the separation between the equipment and receiver ·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected ·Consult the dealer or an experienced radio/TVtechnician for help Cet équipement est conforme aux limitesd'exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance …
Text truncated - open the document above for the full version.
MerlynMindInc. 8West40thStreet,Floor20,NewYork,UnitedStates FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-08-20 Towhomitmayconcern: We,MerlynMindInc.,herebycertifythattheequipmentforwhichauthorizationissought(FCC ID:2AYDX-MUDG3)isnot"covered"equipmentprohibitedfromreceivinganequipmentauthorization pursuantto§2.903oftheFCCrules. Wealsocertifythat,asofthedateofthefilingoftheapplication,wearenotidentifiedontheCovered List(https://www.fcc.gov/supplychain/coveredlist)asanentityproducing"covered"equipment. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslisted under§2.911(b)and(d)(5)and(6). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRas wellasKDB986446D01. Sincerely, Signature MaxTsou MerlynMindInc.
MerlynMindInc. 8West40thStreet,Floor20,NewYork,UnitedStates FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-08-20 U.S.AgentDesignation MerlynMind,Inc.acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoactastheir agentforserviceofprocessfortheequipmentforwhichauthorizationissought (FCCID:2AYDX-MUDG3): NameandcompanyofU.S.agent: PhysicalU.S.addressofagent: FRNofU.S.agent: EmailaddressofU.S.agent: MerlynMindInc. 8West40thStreet,Floor20,NewYork,UnitedStates 0030266753 [email protected] MerlynMindInc.withtheFRN[0030266753]acceptsitsobligationtomaintainanagentforserviceofprocessin theUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingand importationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater Merlyn Mind Inc. acknowledges their obligation to accept service of process on behalf ofMerlyn Mind Inc. . Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature MaxTsou Sr.Dir.ofHWR&D MerlynMindInc. Signature MaxTsou Sr.Dir.ofHWR&D MerlynMindInc. 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
CONFIDENTIALITYREQUEST forCertificationServiceinUSA FederalCommunicationCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21046 Date:<2024-08-20> PursuanttoParagraphs$0.457and0.459oftheCommission'sRules(47C.F.R.)and Section§552(b)(4)oftheFreedomofInformationAct,werequestsconfidentialityfor thefollowingproducts: FCCID Modelname 2AYDX-MUDG3MUDG3 Fortheproductstatedabove,werequestthatthefollowinginformationbeheld confidential; Thelong-termconfidentialityexhibitscontainourtradesecretsandproprietary informationthatcouldbeofbenefittoourcompetitors. Theshort-termconfidentialityonthebasisofensuringthatbusinesssensitive informationremainsconfidentialuntiltheactualmarketingofournewdevice. Ifyouhaveanyquestions,pleasefeelfreetocontactmeattheaddressshownbelow. Sincerely Name/Title: MaxTsou/Sr.Dir.ofHWR&D Company:MerlynMindInc. Address:8West40thStreet,Floor20,NewYork,UnitedStates Phone: 714-6993737 Fax: N/A E-Mail:[email protected]
MerlynMindInc. 8West40thStreet,Floor20,NewYork,UnitedStates FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 2024-08-20 Towhomitmayconcen: We,theundersigned,herebyauthorizeEurofinsProductServiceGmbHtoactonourbehalfinallmatters relatingtoapplicationsforequipmentauthorizationFCCID:2AYDX-MUDG3includingthesigningof all documentsrelatedtothesematters. AnyandallactscarriedoutbyEurofinsProductServiceGmbHonourbehalfshallhavethesameeffect asactsofourown. Bysigningthisapplicationform,weagreetoEurofins'currentvalidGeneralTermsandConditions (AGB),TestingandCertificationRegulations(PZO)whichcanbeviewedonfollowingwebsite www.eurofins.de/eeorretrievedonrequest. Wealsoherebycertifythatnopartytothisapplicationissubjecttoadenialofbenefits,includingFCC benefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.862. Sincerely Name/Title Company: Address: Phone: Fax: E-Mail: MaxTsou/Sr.Dir.ofHWR&D MerlynMindInc. 8West40thStreet,Floor20,NewYork,UnitedStates 714-6993737 NA [email protected]
Page: 1 of 3 PHOTOGRAPHSOFEUT FCCID:2AYDX-MUDG3 Page: 2 of 3 Page: 3 of 3
Note:ThelabelisprintedontheproductbymeansofSpraypaint. FCCID:2AYDX-MUDG3 IC:26781-MUDG Merlyn USB Dongle HVINMUDG3 3
Page: 1 of 2 PHOTOGRAPHSOFEUT FCCID:2AYDX-MUDG3 Page: 2 of 2
DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] RFExposureEvaluationReport ApplicationNo.:DNT240953R1581-5265 Applicant:MerlynMindInc. AddressofApplicant: 8West40thStreet,Floor20,NewYork,UnitedStates EUTDescription:MerlynUSBDongle ModelNo.: MUDG3 FCCID: 2AYDX-MUDG3 PowersupplyDC5V TradeMark:Merlyn Standards: 47CFRPart2.1091 FCCKDB447498D01v06 DateofReceipt:2024/6/1 DateofTest:2024/6/2to2024/9/23 DateofIssue:2024/9/24 TestResult:PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:Ifthereisanyobjectiontotheresultsinthisreport,pleasesubmitawritteninquirytothecompanywithin15daysfromthedateof receivingthereport.Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,andisissuedbythecompanyinaccordance withtherequirementsofthe"ConditionsofIssuanceofTestReports"printedintheattachedpage.Unlessotherwisestated,theresults presentedinthisreportonlyapplytothesamplestestedthistime.Partialreproductionofthisreportisnotallowedunlessapprovedbythe companyinwriting. ReportNo.:DNT240953R1581-5265Date:September24,2024Page: 2 / 6 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V1.0/Sep.24,2024ValidOriginalReport ReportNo.:DNT240953R1581-5265Date:September24,2024Page: 3 / 6 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Contents 1GENERALINFORMATION.......................................................................................................................4 1.1TESTLOCATION..................................................................................................................................4 1.2GENERALDESCRIPTIONOFEUT.........................................................................................................4 2RFEXPOSUREEVALUATION.................................................................................................................5 2.1RFEXPOSURECOMPLIANCEREQUIREMENT........................................................................................5 2.1.1Limits.............................................................................................................................................5 2.1.2TestProcedure.............................................................................................................................6 2.1.3EUTRFExposureEvaluation.......................................................................................................6 ReportNo.:DNT240953R1581-5265Date:September24,2024Page: 4 / 6 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1GeneralInformation 1.1TestLocation Company:DongguanDNTestingCo.,Ltd Address: No.1,WestFourthStreet,SouthXinfaRoad,WushaLiwu,Chang'anTown, DongguanCity,GuangdongP.R.China Testengineer:WayneLin 1.2GeneralDescriptionofEUT Manufacturer: ShenzhenC&DElectronicsCo.,Ltd AddressofManufacturer: 10/F,Unit1,BlockABuilding1,BaonengS&TPark,QingXiangRd.,Longhua, Shenzhen518110,China EUTDescription:: MerlynUSBDongle TestModelNo.: MUDG3 AdditionalModel(s): / ChipType: TLSR8272F512ET24 SerialNumber PR240953R1581 PowerSupply DC3.8VFromBattery;DC5VFromAdapterInputAC100-240V,50/60Hz TradeMark: Merlyn HardwareVersion: V1.2 SoftwareVersion: V1.0 SampleType: PortableDevice,Module,MobileDevice AntennaType: External,Integrated AntennaGain: Providedbyapplicant 4.55dBi Remark: *Sincetheabovedataand/orinformationisprovidedbytheapplicantrelevantresultsorconclusionsofthisreport areonlymadeforthesedataand/orinformation,DNTisnotresponsiblefortheauthenticity,integrityandresultsofthe dataandinformationand/orthevalidityoftheconclusion. ReportNo.:DNT240953R1581-5265Date:September24,2024Page: 5 / 6 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 2RFExposureEvaluation 2.1RFExposureComplianceRequirement 2.1.1Limits Frequencyrange (MHz) Electricfieldstrength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm2) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3-3.06141.63*(100)6 3.0-301842/f4.89/f*(900/f2)6 30-30061.40.1631.06 300-1500//f/3006 1500-100,000//56 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*(100)30 1.34-30824/f2.19/f*(180/f2)30 30-30027.50.0730.230 300-1500//f/150030 1500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity RFexposurecompliancewillneedtobedeterminedwithrespectto1.1307(c)and(d)oftheFCCrules.The emissionsshouldbewithinthelimitsat300kHzinTable1of1.1310(usethe300kHzlimitsfor 150kHz:614V/m,1.63A/m). FriisFormula Friistransmissionformula:Pd=(Pout*G)/(4*Pi*R2) Where Pd=powerdensityinmW/cm2 Pout=outputpowertoantennainmW G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantennaandthetotalpowerinputtothe antenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. ReportNo.:DNT240953R1581-5265Date:September24,2024Page: 6 / 6 DongguanDNTestingCo.,Ltd. Add:No.1,WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'anTown,DongguanCity,GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 2.1.2TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitdataatlowest,middleandhighestchannelindividually 2.1.3 EUTRFExposureEvaluation Antenna…
Text truncated - open the document above for the full version.
DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] FCC Test Report ApplicationNo.: DNT240953R1581-5266 Applicant: MerlynMindInc. Addressof Applicant:8 West40th Street,Floor20,NewYork,UnitedStates EUT Description: MerlynUSBDongle ModelNo.: MUDG3 FCC ID: 2AYDX-MUDG3 PowerSupply DC 5V TradeMark: Merlyn Standards: 47 CFRFCCPart 2, SubpartJ 47 CFRPart 15, SubpartC ANSI C63.10: 20 20 Dateof Receipt: 202 4/6 /1 Dateof Test: 202 4/6 /2 to 202 4/9 /23 Dateof Issue: 202 4/9 /24 Test Result:PASS PreparedBy:(TestingEngineer) ReviewedBy:(ProjectEngineer) ApprovedBy:(Manager) Note:If thereis any objectionto the resultsin this report,pleasesubmita writteninquiryto the companywithin15 daysfrom the date of receivingthe report.The test reportis effectiveonly with both signatureand specializedstamp,and is issuedby the companyin accordance with the requirementsof the "Conditionsof Issuanceof Test Reports"printedin the attachedpage.Unlessotherwisestated,the results presentedin this reportonly applyto the samplestestedthis time.Partialreproductionof this reportis not allowedunlessapprovedby the companyin writing. ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 2 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportReviseRecord ReportVersionReviseTimeIssuedDateValidVersionNotes V2 .0/ Sep .24 , 202 4 ValidOriginalReport ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 3 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] 1 TestSummary Test ItemTest RequirementTest MethodTest ResultResult AntennaRequirement 15.203/247(b)--Clause3.1PASS DutyCycle----Clause3.2PASS DTS (6 dB) Bandwidth15.247(a)(2)ANSIC63.10:2020Clause3.3PASS ConductedOutputPower15.247(b)(3)ANSIC63.10:2020Clause3.4PASS PowerSpectralDensity15.247(e)ANSIC63.10:2020Clause3.5PASS Band-edgefor RF ConductedEmissions 15.247(d)ANSIC63.10:2020Clause3.6PASS RF ConductedSpurious Emissions 15.247(d)ANSIC63.10:2020Clause3.7PASS RadiatedSpuriousEmissions15.247(d);15.205/15.209ANSIC63.10:2020Clause3.8PASS Restrictedbandsaround fundamentalfrequency(Radiated Emission) 15.247(d);15.205/15.209ANSIC63.10:2020Clause3.9PASS AC PowerLine ConductedEmission 15.207ANSIC63.10:2020Clause3.10PASS Note: 1. “N/A ” denotestest is not applicablein this test report . ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 4 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Contents 1 Test Summary..................................................................................................................................................................3 2 GeneralInformation..........................................................................................................................................................5 2.1 Test Location..........................................................................................................................................................5 2.2 GeneralDescriptionof EUT ...................................................................................................................................5 2.3 ChannelList ...........................................................................................................................................................6 2.4 Test Environmentand Mode..................................................................................................................................6 2.5 PowerSettingof Test Software.............................................................................................................................6 2.6 Descriptionof SupportUnit s..................................................................................................................................6 2.7 Test Facility............................................................................................................................................................7 2.8 MeasurementUncertainty(95%confidencelevels,k= 2) ......................................................................................7 2.9 EquipmentList .......................................................................................................................................................8 2.10 Assistantequipmentusedfor test ........................................................................................................................9 3 Test resultsand MeasurementData ..............................................................................................................................10 3.1 AntennaRequirement..........................................................................................................................................10 3.2 DutyCycle............................................................................................................................................................11 3.3 DTS (6 dB) Bandwidth.........................................................................................................................................12 3.4 ConductedOutputPower.....................................................................................................................................13 3.5 PowerSpectralDensity........................................................................................................................................14 3.6 Band-edgefor RF ConductedEmission…
Text truncated - open the document above for the full version.
ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 42 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 AppendixD: Maximumpowerspectraldensity TestResult ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 43 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] Test ModeAntennaFreq(MHz)Result[dBm/3-100kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-4.54≤8.00PASS 2440-5.31≤8.00PASS 2480-5.43≤8.00PASS BLE_2MAnt1 2402-9.07≤8.00PASS 2440-9.40≤8.00PASS 2480-9.64≤8.00PASS ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 44 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 45 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 46 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] AppendixE: Bandedgemeasurements TestResult Test ModeAntennaCh Name Freq (MHz) RefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low24027.64-30.2≤-12.37PASS High24806.67-36.31≤-13.33PASS BLE_2MAnt1 Low24025.62-23.81≤-14.38PASS High24806.71-37.54≤-13.29PASS ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 47 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] TestGraphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 BLE_2M_Ant1_Low_2402 BLE_2M_Ant1_High_2480 ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 48 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 49 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] AppendixF: ConductedSpuriousEmission TestResult Test ModeAntennaFreq(MHz) FreqRange [MH z] RefLevel [dBm ] Result[dBm ]Limit[dBm ]Verdict BLE_1MAnt1 2402 Reference5.975.97---PASS 30~10005.97-58.48≤-14.03PASS 1000~265005.97-36.99≤-14.03PASS 2440 Reference5.345.34---PASS 30~10005.34-57.91≤-14.66PASS 1000~265005.34-37.21≤-14.66PASS 2480 Reference4.064.06---PASS 30~10004.06-58.34≤-15.94PASS 1000~265004.06-41.62≤-15.94PASS BLE_2MAnt1 2402 Reference2.242.24---PASS 30~10002.24-58.5≤-17.76PASS 1000~265002.24-40.89≤-17.76PASS 2440 Reference5.995.99---PASS 30~10005.99-57.18≤-14.01PASS 1000~265005.99-35.02≤-14.01PASS 2480 Reference3.913.91---PASS 30~10003.91-57.5≤-16.09PASS 1000~265003.91-40.13≤-16.09PASS ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 50 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] TestGraphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 51 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_1M_Ant1_2440_30~1000 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 52 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 BLE_2M_Ant1_2402_0~Reference ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 53 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_2M_Ant1_2402_30~1000 BLE_2M_Ant1_2402_1000~26500 BLE_2M_Ant1_2440_0~Reference ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 54 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_2M_Ant1_2440_30~1000 BLE_2M_Ant1_2440_1000~26500 BLE_2M_Ant1_2480_0~Reference ReportNo.:DNT240953R1581-5266Date :September24, 2024Page: 55 / 55 DongguanDN TestingCo., Ltd. Add:No. 1, WestFourthStreet,XingfaSouthRoad,WushaCommunity,Chang'an Town,DongguanCity, GuangdongP.R.China Web:www.dn-testing.comTel:+86-769-88087383E-mail:[email protected] BLE_2M_Ant1_2480_30~1000 BLE_2M_Ant1_2480_1000~26500 The End Repor t
Product Number: AN2400-92158BRS-01 Product Name: Antenna Page 2 Index: 1. Revision History / Page 3 2. Specification / Page 4 3. Characteristics and Reliability Test / Page 5 4. Antenna - S Parameter Test Data / Page 6 5. Antenna - Radiation Pattern Test Data / Page 7 6. Mechanical and Packing Drawing / Page 8 ~ 9 7. Material Description and RoHS Test Report / Page 10 ~ end Product Number: AN2400-92158BRS-01 Product Name: Antenna Page 3 1. Revision History Revision Date Change NotificationDescription 1.0 2023.05.11 初版 Product Number: AN2400-92158BRS-01 Product Name: Antenna Page 4 2. Specification Sample Photo A. Electrical Characteristics Frequency 2400 ~ 2500 MHz V. S . W. R ≦2.0 Peak Gain 5dBi / Max Polarization Linear Impedance 50 Ohm B. Material & Mechanical Characteristics Material of Radiator CU Material of Plastic TPEE / ABS Cable Type RG-178U Connector Type SMA Male Reverse C. Environmental Operation Temperature - 40 ̊C ~ + 65 ̊C Storage Temperature - 40 ̊C ~ + 80 ̊C Antenna Color Storage life < 2 year Product Number: AN2400-92158BRS-01 Product Name: Antenna Page 5 3. Characteristics and Reliability Test Test Items測試 項目 Test Condition and Procedure測試方法 Requirements要求 Result 結果 C1 V.S.W.R. 電壓駐波比 Set DUT on Network Analyzer; make individual calibration to test 設置網路分析儀參數進行測試 Directive DUT specification 符合待測物規範 PASS C3 Antenna Gain 天線增益 Set DUT on Antenna Chamber; make individual calibration to test 設置天線暗室參數進行測試 Directive DUT specificatio…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 6.80 mW |

Merlyn USB Dongle
Equipment Class
DTS - Digital Transmission System
Symphony Classroom Remote Control
Equipment Class
DTS - Digital Transmission System
Symphoney Classroom AI Enabled Classroom Hub
Equipment Class
NII - Unlicensed National Information Infrastructure TX