Made in Cambodia Residential use only Indoor use only Fabriqué au Cambodge Usage résidentiel seulement Usage intérieur seulement Hecho en Camboya Uso residencial solamente Uso interior solamente Rev. 08-05-2020 Ultra-Thin LED Panel - Skylight TM INSTRUCTION MANUAL IMPORTANT, KEEP FOR FUTURE REFERENCE: PLEASE READ CAREFULLY. Panneau à DEL ultra mince - Skylight MC MANUEL D’INSTRUCTIONS IMPORTANT : À LIRE ATTENTIVEMENT ET CONSERVER. Panel LED ultra delgado - Skylight MR MANUAL DE INSTRUCCIONES IMPORTANTE, LEER PARA FUTURA REFERENCIA : POR FAVOR, LEER DETENIDAMENTE. ITM. / ART. 1229097 Model / Modèle / Modelo: FLP14SC-C 2 INSTRUCTION MANUAL / MANUEL D’INSTRUCTIONS / MANUAL DE INSTRUCCIONES EN INCLUDED FR INCLUS ES INCLUIDO WHAT YOU WILL NEED...VOUS AUREZ BESOIN DE...LO QUE NECESITARÁ... Screwdriver Tournevis Destornillador Item Pièce Pieza Description Description Descripción Quantity Quantité Cantidad Junction box screw Vis de boitier de raccordement Tornillo de caja de conexiones x 2 Wire connector Capuchon de connexion Conector de cable x 3 Retaining screw Vis de fixation Tornillo de fijación x 4 Wall anchor Ancrage mural Anclaje mural x 4 Mounting plate Plaque de montage Placa de montaje x 1 LED panel with 2 wired hooks Panneau à DEL avec 2 crochets câblés Panel LED con 2 ganchos x 1 Drill Perceuse Taladro ¼-in. drill bit (6.5 mm) Mèche de ¼ po (6,5 mm) Broca de ¼ plg (6,5 mm) Pencil Crayon Lápiz 3 EN CAUTION If using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes effective in the region where the unit is used. FR ATTENTION Si un gradateur est utilisé, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou de dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains états ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. ES ATENCIÓN Si utiliza un regulador, debe asegurarse de que es compatible con las luces LED. IMPORTANTE El instalador o usuario deben leer detenidamente las instrucciones antes de instalar el producto y seguirlas fielmente. El producto debe estar correctamente instalado antes de su instalación. Si no siguen las instrucciones, el fabricante no se hará responsable de problemas o de un funcionamiento incorrecto del producto. Si no sigue las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea conectado por un electricista certificado siguiendo los códigos eléctricos y arquitectónicos de la región. WARNING: Risk of electrical shock. Turn off breaker at the panel. AVERTISSEMENT : Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Switch off the main electrical supply from the fuse box/circuit breaker before installing the unit or doing any maintenance. Do not use outdoor. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. Ne pas utiliser à l’extérieur. Desconecte la instalación eléctrica en la caja de circuitos/disyuntor antes de instalar esta unidad o realizar tareas de mantenimiento en ella. No usar en exteriores. This product is compatible with most LED dimmers Compatible avec la plupart des gradateurs à DEL Compatible con la mayoría de los reguladores LED 4 INSTRUCTION MANUAL / MANUEL D’INSTRUCTIONS / MANUAL DE INSTRUCCIONES EN INSTALLATION ON GYPSUM CEILING, SURFACE MOUNTING 1. Turn off power at the circuit breaker and the light switch. Ensure the power is off before continuing. 2. Install the mounting plate temporarily on the junction box using the two junction box screws. Place the mounting plate so that the arrow label points to the left (fig. 1a). FR INSTALLATION SUR PLAFOND DE GYPSE, MONTAGE EN SURFACE 1. Couper le courant électrique au niveau du disjoncteur et sur l’interrupteur du luminaire. S’assurer que le courant est éteint avant de continuer. 2. Installer la plaque de montage temporairement sur le boitier de raccordement à l’aide des deux vis de boitier de raccordement. Placer la plaque de montage de manière à ce que la flèche autocollante pointe vers la gauche (fig. 1a). ES INSTALACIÓN EN CEPILLO DE YESO, MONTAJE SUPERFICIAL 1. Desconecte la instalación eléctrica y apague el interruptor. Asegúrese de que la corriente está desconectada antes de continuar. 2. Instale el soporte de montaje temporalmente en la caja de conexiones utilizando los tornillos de la caja de conexiones. Coloque la placa de montaje de modo que la etiqueta de la flecha indique hacia la izquierda (fig. 1a). WARNING: Risk of electrical shock. Turn off breaker at the panel. AVERTISSEMENT : Risque de décharge électrique. Éteindre le disjoncteur sur le panneau é…
Text truncated - open the document above for the full version.
ARTIKA FOR LIVING INC. Add: 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Date: 2020/12/22 FCC ID: 2AYFP-FLP14SC-C Dear Sir/Madam, We, ARTIKA FOR LIVING INC. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Sunray or Skylight Model no.: FLP14SC-C, FLP14SC-XXXXXXX, FLP14-XXXXXX-XXXXXX (“X” can be A to Z and/or 0 to 9 and or/spaces(commerical code) Sincerely, Name/Title: Mathieu Seguin/Manager Company: ARTIKA FOR LIVING INC. Address: 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2020/12/22> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AYFP-FLP14SC-C FLP14SC-C For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Mathieu Seguin/Manager Company: ARTIKA FOR LIVING INC. Address: 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]
ARTIKA FOR LIVING INC. 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2020/12/22 To whom it may concern: We, ARTIKA FOR LIVING INC. the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AYFP-FLP14SC-C including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Mathieu Seguin/Manager Company: ARTIKA FOR LIVING INC. Address: 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 3 EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 3 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 3 of 3 Fig. 5 Fig. 6
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 5.0cm*W: 3.0cm Label Location Sunray or Skylight Model No.: FLP14SC-C FCC ID :2AYFP-FLP14SC-C
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 2 INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C ________________________________________________________________________________ _________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 2 of 2 Fig.3
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 20 FCC SDoC TEST REPORT ARTIKA FOR LIVING INC. Sunray or Skylight Test Model: FLP14SC-C Additional Model No.: Please Refer To Page 7 Prepared for : ARTIKA FOR LIVING INC. Address : 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : November 26, 2020 Number of tested samples : 1 sample number : 201109202A-1 Date of Test : November 26, 2020 ~ December 01, 2020 Date of Report : December 02, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 20 FCC SDoC TEST REPORT FCC 47 CFR Part 15 Subpart B, Class B(SDoC), ANSI C63.4 -2014 Report Reference No. ......... : LCS201109202AE Date Of Issue .......................... : December 02, 2020 Testing Laboratory Name .... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .................................. : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name.................. : ARTIKA FOR LIVING INC. Address .................................. : 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Test Specification Standard ................................. : FCC 47 CFR Part 15 Subpart B, Class B(SDoC), ANSI C63.4 -2014 Test Report Form No. ............. : LCSEMC-1.0 TRF Originator ........................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ............................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .......... : Sunray or Skylight Test Model ............................ : FLP14SC-C Trade Mark ............................. : ARTIKA Ratings ................................... : Input: AC120V, 60Hz, 45W Result ................................... : Positive Compiled by: Supervised by: Approved by: Scent Hu / Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 20 FCC -- TEST REPORT Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS201109202AE December 02, 2020 Date of issue Test Model ........................ : FLP14SC-C EUT.................................... : Sunray or Skylight Applicant........................... : ARTIKA FOR LIVING INC. Address.............................. : 1756, 50th avenue, Lachine, Québec, Canada H8T 2V5 Telephone.......................... : / Fax..................................... : / Manufacturer..................... : SHININGMOON LIGHTING (CAMBODIA) CO.,LTD. Address.............................. : D3 Y Seven Industrial Park III ,National road no.4, Sangkrous Cheat village, Trapang Korng Commune, Samrong Toung District, Kampong Speu, Cambodia Telephone.......................... : / Fax..................................... : / Factory.............................. : SHININGMOON LIGHTING (CAMBODIA) CO.,LTD. Address.............................. : D3 Y Seven Industrial Park III ,National road no.4, Sangkrous Cheat village, Trapang Korng Commune, Samrong Toung District, Kampong Speu, Cambodia Telephone.......................... : / Fax..................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 20 Revision History Revision Issue Date Revisions Revised By 000 December 02, 2020 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 20 TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS ................................................................. 6 1.1. Description of Standards and Results .................................................................................. 6 2. GENERAL INFORMATION ................................................................................................... 7 2.1. Description of Device (EUT) ........................................................................................................ 7 2.2. Support Equipment List ................................................................................................................ 7 2.3. Description of T…
Text truncated - open the document above for the full version.
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AYFP-FLP14SC-C _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.. Page 1 of 1 Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Below 1GHz Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Alton Ceiling light
Equipment Class
JAB - Part 15 Class B Digital Device
Oracle Vanity 1L5 CCT Chrome
Equipment Class
JAV - Other Non-Digital SDoC Devices
LED Luminaire
Equipment Class
JAV - Other Non-Digital SDoC Devices
Aristo Flushmount
Equipment Class
JAV - Other Non-Digital SDoC Devices
Concerto FM
Equipment Class
JAV - Other Non-Digital SDoC Devices