Made in China Residential use only Indoor or outdoor use Fabriqué en Chine Usage résidentiel seulement Usage intérieur ou extérieur Hecho en China Uso residencial solamente Uso interior o exterior Rev. 08-01-2021 Model / Modèle / Modelo: 17OUT-GL-PMB Wall-mounted LED light fixture - Glacier Pro tm INSTRUCTION MANUAL IMPORTANT: READ CAREFULLY AND KEEP. Luminaire mural à DEL - Glacier Pro mc MANUEL D’INSTRUCTIONS IMPORTANT : À LIRE ATTENTIVEMENT ET À CONSERVER. Lámpara de pared LED - Glacier Pro mr MANUAL DE INSTRUCCIONES IMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. 2 INCLUDED HARDWARE MATÉRIEL INCLUS HERRAMIENTAS INCLUIDO Item Pièce Pieza Description Description Descripción Quantity Quantité Cantidad A Wall anchor Ancrage mural Ancla de pared × 3 B Junction box screw Vis de boitier de raccordement Tornillo de caja de conexiones × 3 C Mounting bracket Support de montage Soporte de montaje × 1 D Junction box screw Vis de boitier de raccordement Tornillo de caja de conexiones × 2 E Wire connector Capuchon de connexion Conector de cable × 3 F Rubber Washer Rondelle en caoutchouc Arandela de gomas × 4 G Mounting screw Vis de montage Tornillo de montaje × 4 H Light fixture Luminaire Luminario × 1 3 STEP-BY-STEP INSTALLATION INSTALLATION DÉTAILLÉE INSTALACIÓN ETAPA POR ETAPA WHAT YOU WILL NEED VOUS AUREZ BESOIN LO QUE NECESITARÁ A B C D E F G H H Screwdriver Tournevis Destornillador Scealant Scellant Sellador Level Niveau Nivel Pencil Crayon Lápiz 2 4 WARNING: Risk of electrical shock. Turn off breaker at the panel. Switch off the main electrical supply from the fuse box/ circuit breaker before installing the unit or doing any maintenance. indoor/outdoor light. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien. éclairage intérieur / extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la instalación eléctrica en la caja de circuitos/ disyuntor antes de instalar esta unidad o realizar tareas de mantenimiento en ella. Luz interior / exterior. CAUTION: If using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty. We recommend that this product be installed by a certified electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certified electrician, according to the electrical and building codes effective in the region where the unit is used. ATTENTION Si vous utilisez un gradateur, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou de dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisation annulera la garantie en vigueur. Nous recommandons que ce produit soit installé par un électricien certifié. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certifié conformément aux codes de l’électricité et du bâtiment en vigueur. ATENCIÓN Si utiliza un regulador, debe asegurarse de que es compatible con las luces LED. IMPORTANTE El instalador o usuario debe leer detenidamente las instrucciones antes de instalar el producto y seguirlas fielmente. El producto debe estar correctamente instalado antes de su utilización. Si no siguen las instrucciones, el fabricante no se hará responsable de problemas o de un funcionamiento incorrecto del producto. Si no sigue las instrucciones de instalación o de uso, se anulará la garantía. Le recomendamos que el producto sea instalado por un electricista certificado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea conectado por un electricista certificado siguiendo los códigos eléctricos y arquitectónicos de la región. CAUTION ATTENTION ATENCIÓN 5 MOUNTING BRACKET INSTALLATION INSTALLATION DU SUPPORT DE MONTAGE INSTALACIÓN DEL SOPORTE DE MONTAJE 1 A A B BBA C D 6 CONNECTING THE WIRES AND CANOPY INSTALLATION CONNEXION DES FILS ET INSTALLATION DE LA BASE CONECTANDO LOS CABLES Y INSTALACIÓN DEL DOSEL 2 Ground wire (G) Fil de mise à la terre (G) Cable de tierra (G) C E H H Black (L) Noir (L) Negro (L) White (N) Blanc (N) Blanco (N) Ground wire (G) Fil de mise à la terre (G) Cable de tierra (G) 7 FINAL INSTALLATION NSTALLATION FINALE INSTALACIÓN FINAL 3 H C F G G H 8 FINAL INSTALLATION INSTALLATION FINALE INSTALACIÓN FINAL 4 TO ALLOW MOISTURE TO DRAIN, DO NOT SEAL BOTTOM SIDE OF THE BACKPLATE POUR PERMETTRE À L’HUMIDITÉ DE VIDER, NE PAS SCELLER LE CÔTÉ INFÉRIEUR DE LA PLAQUE ARRIÈRE PARA PERMITIR QUE LA HUMEDAD DRENE, NO SELLAR LA PARTE INFERIOR DE LA PLACA POSTERIOR ! Apply sealant to seal the sides and top of the light fixture to the wall. Appliquez le scellant sur les côtés et le dessus du Luminaire Aplique el sellador en los lados y en la parte superior de luminario 9 Operation is subject to the following two conditions: 1. this device may not cause interference, and 2. this device must accept any inteference, including inteference that may cause undesired operation of the device. L’exploitation est autorisée aux deux conditions suivantes : 1. l’appareil ne doit pas produire de brouillage; et 2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en com…
Text truncated - open the document above for the full version.
Differences Declaration To whom concern, We company ARTIKA FOR LIVING INC Here by declares: The series model 17OUT-GL-XXXXXX is models use the same circuit principle, the same PCB layout, and the difference is that they have different shell colors and have been tested in STANDARD-TECH TESTING SERVICES. The differences in series models are as follows: 17OUT-GL-XXXXXX (Remark: “X” can be A to Z and/or 0 to 9 and or/blank(commerical code).) Name : Company name: ARTIKA FOR LIVING INC Company address: 1756 50th avenue, Lachine, Québec, Canada H8T 2V5 Tel: 1.514.883.8699 E-Mail: [email protected]
ARTIKA FOR LIVING INC 2021.01.18 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product Name: Glacier Pro Trademark: ARTIKA Model Number(s): 17OUT-GL-XXXXXX FCC ID: 2AYFP17OUT-GL-PMB To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics -Operation description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarilyreleased to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Client’s signature: Client’s name / title : Mathieu.Seguin / Engineering/QC Director Contact information / address: 1756 50th avenue, Lachine, Québec, Canada H8T 2V5
ARTIKA FOR LIVING INC 2021.01.18 Eurofins MET Labs 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize STANDARD-TECH TESTING SERVICES/Standard- Tech Building,No. 6 Guanhong Road, GuangzhouScience City, Guangzhou 510663, China to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Printed Name of Authorized Applicant Contact: Mathieu.Seguin Signature of Authorized Applicant Contact: Title of Authorized Applicant Contact: Engineering/QC Director Date: 2021.01.18
Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 1 of 1 PhotooftheEUT
LabelLocation
Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 1 of 3 PhotooftheEUT Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 2 of 3 Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 3 of 3
BOM LIST No. Name Number 1 Grounding wire 1 2 Internal wire 4 3 Steel wire 1 4 Mounting bar 1 5 Diffuser 3 6LED PCB 4 7 Canopy 1 8 Heat sink 2 9LED 72 10 LED driver 1 11 Gasket 2 12 Light Guide Plate 1 13 Polymeric Film 1
Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 1 of 18 FCCPART15BTESTREPORTFORCERTIFICATION OnBehalfof ARTIKAFORLIVINGINC *************************************** FCCID : 2AYFP17OUT-GL-PMB ReportType : Originalreport ProductType : GlacierPro TestEngineer:ClintChen ReportNumber:STDNB-201207F-002 ReportDate:2020-12-23 ReviewedBy: LionLi PreparedBy: Standard-TechCo.,Ltd.TestingCenter Standard-TechBuilding,No.6GuanhongRoad,Guangzhou ScienceCity,Guangzhou510663,China Tel:+86-20-32290320/32290719 Fax:+86-20-32290422/32290556 www.standard-tech.com ThedevicedescribedaboveistestedbyStandard-TechCo.,Ltd.TestingCenter.toconfirmcomplywithalltheFCCPart15SubpartCrequirements.Thetestresultsare containedinthistestreportandStandard-TechCo.,Ltd.TestingCenterisassumedfullresponsibilityfortheaccuracyandcompletenessofthesetests.Also,thisreport showsthattheEquipmentUnderTest(EUT)istobetechnicallycompliantwiththeFCCrequirements.ThisReportismadeunderFCCPart2.1074.Nomodifications wererequiredduringtestingtobringthisproductintocompliance.Thisreportappliestoabovetestedsampleonly.Thisreportshallnotbereproducedinpartwithout writtenapprovalofStandard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 2 of 18 TABLEOFCONTENTS DescriptionPage 1.SUMMARYOFSTANDARDSANDRESULTS........................................................................3 1.1.DescriptionofStandardsandResults.................................................................................3 2.GENERALINFORMATION........................................................................................................3 2.1.DescriptionofEquipmentUnderTest................................................................................3 2.2.EquipmentsUsedduringtheTest.......................................................................................4 2.3.TestFacility........................................................................................................................4 2.4.MeasurementUncertainty(95%confidencelevels,k=2)...................................................5 3.POWERLINECONDUCTEDEMISSIONTEST......................................................................6 3.1.BlockDiagramofTestSetup..............................................................................................6 3.2.PowerLineConductedEmissionTestLimits....................................................................6 3.3.TestProcedure....................................................................................................................6 3.4.TestEnvironment................................................................................................................6 4.RADIATEDEMISSIONTEST...................................................................................................11 4.1.BlockDiagramofTestSetup............................................................................................11 4.2.RadiatedEmissionLimit...................................................................................................12 4.3.TestProcedure..................................................................................................................13 4.4.TestEnvironment..............................................................................................................13 Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 3 of 18 1.SUMMARYOFSTANDARDSANDRESULTS 1.1.DescriptionofStandardsandResults TheEUThasbeentestedaccordingtotheapplicablestandardsasreferencedbelow. EMISSION DescriptionofTestItemStandardResults PowerLineConductedEmission FCCPart15:15.207 PASS RadiatedEmission FCCPart15:15.209 PASS 2.GENERALINFORMATION 2.1.DescriptionofEquipmentUnderTest Applicant ARTIKAFORLIVINGINC Manufacturer ARTIKAFORLIVINGINC FactoryNingboShengheLightingCo.,LTD BrandNameARTIKA ProductGlacierPro ModelNo. 17OUT-GL-XXXXXX (Remark:“X”canbeAtoZand/or0to9and or/blank(commericalcode).) PowerAdapterAC120-347V,60Hz,20W SampleTypePrototypeproduction DateofReceipt2020/12/15 DateofTest2020/12/15-2020/12/21 Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 4 of 18 2.2.EquipmentsUsedduringtheTest ConductedEmissions ItemEquipmentManufacturerModelNo.SerialNo.LastCal. Cal. Interval 1.ShieldingRoomAUDIXN/AN/A2018/07/283Year 2.EMITestReceiverRohde&SchwarzESR71014872020/07/292Year 3.V-LISNRohde&SchwarzNNLK81228122-001282019/07/202Year 4.RFCableYuanDaoRG223N/A2020/05/251Year 5.TestSoftwareAUDIXe3N/AN/AN/A Note:N/AmeansNotapplicable. Forfrequencyrange30MHz~1000MHz(In3mAnechoicChamber) ItemEquipmentManufacturerModelNo.SerialNo.LastCal. Cal. Interval 1. Semi-anechoic chamber AUDIXN/AN/A 2018/11/183Year 2. EMITestReceiver R&SESR7101487 2020/07/292Year 3. BiconicalLogarithmic Antenna SCHWARDZBECKVULB91629162-104 2019/01/062Year 4. CableLine PEWCCFD400NLN/A 2020/05/251Year 5.LoopAntennaBeijingDazeZN30900C10622019/12/202Year 6. TestSoftware AUDIXe3N/A N/A1Year Note:N/AmeansNotapplicable. 2.3.TestFacility SiteDescription NameofFirm: Standard-TechCo.,Ltd.TestingCenter Standard-TechBuilding,No.6GuanhongRoad, GuangzhouScienceCity,Guangzhou510663, China EMCLab.: CertificatedbyIndustryCanada RegistrationNumber:20901 ValidDate:2020/02/28 : CertificatedbyFCCUSA. DesignationNo.:CN1222 ValidDate:2020/02/28 Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 5 of 18 2.4.MeasurementUncertainty(95%confidencelevels,k=2) TestItemUncertainty UncertaintyforConductionemissiontest inNo.1Conduction 2.42dB(150KHzto30MHz) UncertaintyforRadiationEmissiontest in3mchamber 3.94dB(30M~1GHz,Distance:3m) UncertaintyforRadiationEmissiontest in3mchamber(1GHz-25GHz) 4.92dB(1~6GHz,Distance:3m) 5.24dB(6~40GHz,Distance:3m) UncertaintyforOutputpowertest0.67dB UncertaintyforBandwidthtest83kHz Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.Page 6 of 18 3.POWERLINECONDUCTEDEMISSIONTEST 3.1.BlockDiagramofTestSetup 3.2.Pow…
Text truncated - open the document above for the full version.
Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 1 of 2 PhotographofTest 1PhotosofPowerLineConductedEmissionTest Standard-TechCo.,Ltd.TestingCenter. Standard-TechCo.,Ltd.TestingCenter.AppendixPage 2 of 2 2PhotosofRadiatedEmissionTest 30-1000MHz
1756 50th avenue · Lachine · Canada
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Alton Ceiling light
Equipment Class
JAB - Part 15 Class B Digital Device
Oracle Vanity 1L5 CCT Chrome
Equipment Class
JAV - Other Non-Digital SDoC Devices
LED Luminaire
Equipment Class
JAV - Other Non-Digital SDoC Devices
Aristo Flushmount
Equipment Class
JAV - Other Non-Digital SDoC Devices
Concerto FM
Equipment Class
JAV - Other Non-Digital SDoC Devices