FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ARTIKA FOR LIVING INC./
  3. 2AYFPPDT4-VIC

2AYFPPDT4-VICLED chandelier

ARTIKA FOR LIVING INC.
LED chandelier - FCC ID 2AYFPPDT4-VIC - ARTIKA FOR LIVING INC.
Click to zoom

Application Details

Equipment Class
JAV - Other Non-Digital SDoC Devices
Date of Grant
Jul 28, 2021
Application Purpose
Original Equipment
Date of Application
Jul 28, 2021
Equipment Note
LED chandelier
Company
ARTIKA FOR LIVING INC.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Made in ChinaFabriqué en ChineHecho en China Residential use onlyUsage résidentiel seulementUso residencial solamente Indoor use only Usage intérieur seulement Uso interior solamente 4-Light LED pendant - Vivaldi TM INSTRUCTION MANUALIMPORTANT: READ CAREFULLY AND KEEP.Suspension à 4 lumières DEL - Vivaldi MC MANUEL D’INSTRUCTIONSIMPORTANT : À LIRE ATTENTIVEMENT ET À CONSERVER.Luminaria suspendida de 4 luces LED - Vivaldi MR MANUAL DE INSTRUCCIONESIMPORTANTE: LEER DETENIDAMENTE Y CONSERVAR. Model / Modèle / Modelo: PDT4-VIC-HD2BL Rev. 05-07-2021 PO-29557 2INCLUDED HARDWAREMATÉRIEL INCLUSHERRAMIENTAS INCLUIDO ITEMPIÈCEPIEZA DESCRIPTION DESCRIPTIONDESCRIPCIÓN QUANTITYQUANTITÉCANTIDAD A Wall anchorAncrage muralAnclaje mural × 4 B Mounting bracketSupport de montageSoporte de montaje × 1 C Retaining screwVis de fi xation Tornillo de fi jación × 4 D Junction box screwVis de boitier de raccordementTornillo de caja de conexiones × 2 E Wire connectorCapuchon de connexionConector de cable × 3 F Canopy screwVis de la baseTornillo del dosel × 4+ 1 extra G Light LED pendantSuspension à DELLuminaria LED suspendida × 1 Artika For Living Inc. 1756, 50 th Avenue Montréal (Lachine), QuébecCanada H8T 2V5 [email protected] Customer Service Monday to Friday9 am - 5 pm EST Service à la clientèle Lundi au vendredi9 h à 17 h H.N.E. Atención al cliente Lunes a viernes9 a.m. - 5 p.m. hora del Este 3 STEP-BY-STEP INSTALLATIONINSTALLATION DÉTAILLÉEINSTALACIÓN ETAPA POR ETAPA A B C G F D E ScrewdriverTournevis 2 DestornilladorWHAT YOU WILL NEEDVOUS AUREZ BESOINLO QUE NECESITARÁ DrillPerceuseTaladro ¼-in. drill bit (6.5 mm)Mèche de ¼ po (6,5 mm)Broca de ¼ plg (6,5 mm)PencilCrayonLápiz 4CAUTIONATTENTIONATENCIÓN WARNING: Risk of electrical shock.Turn o ff breaker at the panel. Switch o ff the main electrical supply from the fuse box/circuit breaker before installing the unit or doing any maintenance.Do not use outdoor. AVERTISSEMENT: Risque de décharge électrique. Éteindre le disjoncteur sur le panneau électrique. Il est important de couper l’alimentation électrique du disjoncteur avant de procéder à l’installation ou à l’entretien.Ne pas utiliser à l’extérieur. ADVERTENCIA: Riesgo de descarga eléctrica. Desconectar la corriente eléctrica del panel (disyuntor). Desconecte la instalación eléctrica en la caja de circuitos/disyuntor antes de instalar esta unidad o realizar tareas de mantenimiento en ella.No usar en exteriores. CAUTIONIf using a dimmer, it must be LED compatible. IMPORTANT The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty.We recommend that this product be installed by a certi fi ed electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certi fi ed electrician, according to the electrical and building codes e ff ective in the region where the unit is used. ATTENTIONSi un gradateur est utilisé, celui-ci doit être compatible avec les lumières à DEL. IMPORTANT Avant l’installation de ce produit, l’utilisateur et/ou l’installateur doit avoir lu et compris ces instructions. Cet appareil doit être installé convenablement avant usage. Si ces instructions ne sont pas respectées, le fabricant ne pourra être tenu responsable d’aucun problème ou de dysfonctionnement du produit. Le non-respect des instructions d’installation et/ou d’utilisationannulera la garantie en vigueur.Nous recommandons que ce produit soit installé par un électricien certi fi é. Dans certains États ou provinces, il est légalement requis que ce type de produit soit installé par un électricien certi fi é conformément aux codes de l’électricité et du bâtiment en vigueur. ATENCIÓNSi utiliza un regulador, debe asegurarse de que es compatible con las luces LED. IMPORTANTE El instalador o usuario debe leer detenidamente las instrucciones antes de instalar el producto y seguirlas fi elmente. El producto debe estar correctamente instalado antes de su utilización. Si no siguen las instrucciones, el fabricante no se hará responsable de problemas o de un funcionamiento incorrecto del producto. Si no sigue las instrucciones de instalación o de uso, se anulará la garantía.Le recomendamos que el producto sea instalado por un electricista certi fi cado. En algunos estados o provincias, se requiere por ley que este tipo de producto sea conectado por un electricista certi fi cado siguiendo los códigos eléctricos y arquitectónicos de la región. 13 WARRANTYGARANTIEGARANTÍAArtika For Living Inc. is proud to o ff er you a three-year (3) limited warranty on manufacturing defects from the date of purchase for residential use only. The warranty is extended to the original owner in USA, Canada, Mexico, UK, Iceland, France and Spain and is non-transferable. It does not apply to retailers, commercial applications or establishments. The original sales receipt is required for all warranty claims. The remedy under this limited warranty shall be product or part replacement at Artika’s discretion as provided herein and cannot exceed the original purchase price. This warranty is valid only on products installed in accordance with the building code and laws e ff ective in the region where the unit is being used, as well as in accordance with the provided instruction manual. It does not cover products installed incorrectly or subjected to abnormal use. Product(s) or component part(s) may be required to be returned for inspection and veri fi cation. Normal wear and tear, misuse, negligence, vandalism, improper maintenance (surface damage due to chemical interaction or cleaning agents including, but not limited to, scouring pads, use of cleaners containing abrasives, alcohol or other o…

Text truncated - open the document above for the full version.

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:< 2021-7-27> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AYFPPDT4-VIC MD8195-4-3BD For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Mathieu Seguin/General Manager Company: ARTIKA FOR LIVING INC Address: 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]

Cover Letter(s)

ARTIKA FOR LIVING INC 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2021-7-27 To whom it may concern: We, ARTIKA FOR LIVING INC the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AYFPPDT4-VIC including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Mathieu Seguin/General Manager Company: ARTIKA FOR LIVING INC Address: 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]

Cover Letter(s)

ARTIKA FOR LIVING INC Add: 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Date: 2021-7-27 FCC ID: 2AYFPPDT4-VIC Dear Sir/Madam, We, ARTIKA FOR LIVING INC Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: LED chandelier Model no.: MD8195-4-3BD, PDT4-VIC-XXXXXX (Note: "XXXXXX" can be A to Z and/or 0 to 9 and/or blank (commercial code)) Sincerely, Name/Title: Mathieu Seguin/General Manager Company: ARTIKA FOR LIVING INC Address: 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Phone: 15148838633 Fax: 15148838633 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 External Photos of the EUT Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 Fig. 5 Fig. 6

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 5.0cm*W: 2.5cm LED chandelier Model No.: MD8195-4-3BD FCC ID : 2AYFPPDT4-VIC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la partie 15 des règles de la FCC. Son fonctionnement est soumis aux deux conditions suivantes : 1. ce dispositif ne peut pas causer d’interférences nuisibles; et 2. cet appareil doit accepter toute interférence reçue, y compris les interférences qui peuvent causer un fonctionnement indésirable. Label Location

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 2 Internal Photos of the EUT Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 2 Fig.3 Fig.4

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCCID: 2AYFPPDT4-VIC Report No.: LCS210626020AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 17 FCC Part 15, Subpart B, Class B ARTIKA FOR LIVING INC. LED chandelier Test Model: MD8195-4-3BD Additional Model No.: PDT4-VIC-XXXXXX (Note: "XXXXXX" can be A to Z and/or 0 to 9 and/or blank (commercial code)) Prepared for : ARTIKA FOR LIVING INC. Address : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 26, 2021 Number of tested samples : 1 Sample number : 210626020A Serial number : Prototype Date of Test : June 26, 2021 ~ July 07, 2021 Date of Report : July 07, 2021 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCCID: 2AYFPPDT4-VIC Report No.: LCS210626020AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 17 FCC Part 15, Subpart B, Class B FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Report Reference No. ......... : LCS210626020AE Date Of Issue .......................... : July 07, 2021 Testing Laboratory Name .... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .................................. : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name.................. : ARTIKA FOR LIVING INC. Address .................................. : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Test Specification Standard ................................. : FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Test Report Form No. ............. : LCSEMC-1.0 TRF Originator ........................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ............................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .......... : LED chandelier Test Model ............................ : MD8195-4-3BD Trade Mark ............................. : Artika Ratings ................................... : AC 120V, 50/60Hz,25W Result ................................... : Positive Compiled by: Supervised by: Approved by: Cherry Chen/ Administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCCID: 2AYFPPDT4-VIC Report No.: LCS210626020AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 17 FCC -- TEST REPORT Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS210626020AE July 07, 2021 Date of issue Test Model ........................ : MD8195-4-3BD EUT.................................... : LED chandelier Applicant........................... : ARTIKA FOR LIVING INC. Address.............................. : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Lachine Canada Telephone.......................... : / Fax..................................... : / Manufacturer..................... : HIFLY ILLUMINATION CO.,LIMITED Address.............................. : BLOCK 1,1/F,BUILDING 2,2 YIHUI 3RD ROAD MAOHU I INDUSTRIAL ZONE,HENGLAN TOWN,ZHONGSHAN CITY,GUANGDONG PROVINCE,CHINA Telephone.......................... : / Fax..................................... : / Factory.............................. : HIFLY ILLUMINATION CO.,LIMITED Address.............................. : BLOCK 1,1/F,BUILDING 2,2 YIHUI 3RD ROAD MAOHU I INDUSTRIAL ZONE,HENGLAN TOWN,ZHONGSHAN CITY,GUANGDONG PROVINCE,CHINA Telephone.......................... : / Fax..................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCCID: 2AYFPPDT4-VIC Report No.: LCS210626020AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 17 Revision History Revision Issue Date Revisions Revised By 000 July 07, 2021 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCCID: 2AYFPPDT4-VIC Report No.: LCS210626020AE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 17 TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS ............................................................... 6 1.1. Description of Standards and Results ...................................................................................... 6 2. GENERAL INFORMATION ................................................................................................. 7 2.1. Description of Device (EUT) ...................................................................................................... 7 2.2. Support Equipment List ..................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AYFPPDT4-VIC _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Test Setup Photo(s) of Conducted Emissions Measurement Fig. 2

Contact Information

Applicant

Mathieu Seguin
[email protected]15148838633Fax: 15148838633

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from ARTIKA FOR LIVING INC.

Alton Ceiling light - FCC ID 2AYFP-FM-ALC-XXX - ARTIKA FOR LIVING INC.
2AYFP-FM-ALC-XXX

Alton Ceiling light

Feb 27, 2023

Equipment Class

JAB - Part 15 Class B Digital Device
Oracle Vanity 1L5 CCT Chrome - FCC ID 2AYFP-VAN1-OR5C - ARTIKA FOR LIVING INC.
2AYFP-VAN1-OR5C

Oracle Vanity 1L5 CCT Chrome

Nov 30, 2022

Equipment Class

JAV - Other Non-Digital SDoC Devices
LED Luminaire - FCC ID 2AYFP-PDT-GL - ARTIKA FOR LIVING INC.
2AYFP-PDT-GL

LED Luminaire

Oct 21, 2022

Equipment Class

JAV - Other Non-Digital SDoC Devices
Aristo Flushmount - FCC ID 2AYFP-FM-ARC - ARTIKA FOR LIVING INC.
2AYFP-FM-ARC

Aristo Flushmount

Sep 26, 2022

Equipment Class

JAV - Other Non-Digital SDoC Devices
Concerto FM - FCC ID 2AYFP-FM-COC - ARTIKA FOR LIVING INC.
2AYFP-FM-COC

Concerto FM

Sep 26, 2022

Equipment Class

JAV - Other Non-Digital SDoC Devices