2AYLG-CWXC530Magnetic Charger

Roumi Technology (Shenzhen)Co.,Ltd
Magnetic Charger - FCC ID 2AYLG-CWXC530 - Roumi Technology (Shenzhen)Co.,Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 25, 2021
Application Purpose
Original Equipment
Date of Application
Jan 25, 2021
Equipment Note
Magnetic Charger
Frequency Range
0.11500000 - 0.20500000
Company
Roumi Technology (Shenzhen)Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynot causeharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15of theFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidential installation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance withtheinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat interferencewillnotoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningthe equipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser's authoritytooperatetheequipment FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected

Attestation Statements

Modeldifferencedeclarationletter DifferencesDescription WeRoumiTechnology(Shenzhen)Co.,Ltdstate: Product: MagneticCharger ModelName CWXC530,DWXC520 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsandwiring structures,Appearanceshape,thematerialsofdecorativeaccessoriesissame,only differentcolor, Signatory Date:01-15-2021 <Signature> Name:JennieWang Title:Manager Company:RoumiTechnology(Shenzhen)Co.,Ltd Address:Room1507,15/F,Saixiscienceandtechnologybuilding,3398BinhaiAvenue,Binhai community,Yuehaistreet,NanshanDistrict,Shenzhen,GuangdongProvince,China

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization RoumiTechnology(Shenzhen)Co.,Ltd Company:RoumiTechnology(Shenzhen)Co.,Ltd Address:Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,NanshanDistrict, Shenzhen,GuangdongProvince,China ProductName:MagneticCharger ModelNumber:CWXC530 FCCIdentifier:2AYLG-CWXC530 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:JennieWangDate:January15,2021 Title:Manager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 RoumiTechnology(Shenzhen)Co.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:January15,2021 Subject:RequestforConfidentiality FCCID:2AYLG-CWXC530 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:JennieWang Title: Manager

External Photos

Page1of3ReportNo.:FCS202101014 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202101014 Photo3 Photo4 Page3of3ReportNo.:FCS202101014 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2AYLG-CWXC530 L*W:10mm*7mm whitefontonaBlacklabel

Internal Photos

Page1of3ReportNo.:FCS202101014 Photo1 Photo2 Page2of3ReportNo.:FCS202101014 Photo3 Photo4 RF chipset Page3of3ReportNo.:FCS202101014 Photo5 Antenna

RF Exposure Info

Page1of4ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RFExposureEvaluation FCCID:2AYLG-CWXC530 1MeasuringStandard KDB680106D01RFExposureWirelessChargingAppsv03 2Requirements AccordingtoKDB680106clause5,b Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcluded (1)Powertransferfrequencyislessthan1MHz. --Yes,thedeviceoperatedinthefrequencyrangefrom115KHzto205KHz (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. --Yes,themaximumoutputpoweroftheprimarycoilis15W (3)Thetransfersystemincludesonlysingleprimaryandsecondarycoils.Thisincludescharging systemsthatmayhavemultipleprimarycoilsandclientsthatareabletodetectandallowcouplingonly betweenindividualpairsofcoils. --Yes,thetransfersystemincludesonlysingleprimaryandsecondarycolis (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. --Yes,Clientdeviceisplaceddirectlyincontactwiththetransmitter (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). --Yes (6)TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetopsurface fromallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPElimit. --Yes,theEUTfieldstrengthlevelare50%xMPElimit. 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page2of4ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 4TestSetup 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfrom thetop)whichisbetweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03. Remark : TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements Page3of4ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 6Equipmentlist TestEquipmentManufacturerModelNo.SN.Cal.Date ExposureLevel Tester NardaELT-400N03565January15,2021 Electricand Magnetic fieldprobe 100cm2 NardaELTprobe100cm2M8976January15,2021 7Photo 7TestResult E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) Page4of4ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 1%0.115-0.2051.222.740.540.47614 50%0.115-0.2051.151.250.380.54614 95%0.115-0.2051.351.870.470.58614 Stand-by0.115-0.2051.452.010.570.42614 E-FiledStrengthat20cmfromthetopoftheEUT(V/m) Battery power Frequency Range(MHz) Test PositionE Limits (V/m) 1%0.115-0.2051.47614 50%0.115-0.2051.15614 95%0.115-0.2051.28614 Stand-by0.115-0.2051.46614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 1%0.115-0.2050.330.540.570.751.63 50%0.115-0.2050.290.420.610.681.63 95%0.115-0.2050.630.490.690.661.63 Stand-by0.115-0.2050.510.480.680.591.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) Battery power Frequency Range(MHz) Test PositionE Limits (A/m) 1%0.115-0.2050.471.63 50%0.115-0.2050.461.63 95%0.115-0.2050.351.63 Stand-by0.115-0.2050.411.63 Testedby:Reviewedby: ※※※※※ENDOFTHEREPORT※※※※※

Test Report

FCCTestReport ReportNo:FCS202101014W01 Issuedfor Applicant: RoumiTechnology(Shenzhen)Co.,Ltd Address: Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,Nanshan District,Shenzhen,GuangdongProvince,China ProductName: MagneticCharger BrandName: ROUMI ModelName: CWXC530 SeriesModel: DWXC520 FCCID: 2AYLG-CWXC530 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:RoumiTechnology(Shenzhen)Co.,Ltd Address......................................: Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,Nanshan District,Shenzhen,GuangdongProvince,China Manufacture'sName ................ :RoumiTechnology(Shenzhen)Co.,Ltd Address......................................: Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,Nanshan District,Shenzhen,G、uangdongProvince,China ProductDescription ProductName ........................... :MagneticCharger BrandName ............................. :ROUMI ModelName .............................. :CWXC530 SeriesModel .............................. :DWXC520 TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section209 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:06Jan.2021~15Jan.2021 DateofIssue.................................:15Jan.2021 TestResult.....................................:Pass Testedby: (ScottShen) Reviewedby : (DukeQian) Approvedby: (KaitChen) Page3of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS5 1.1TESTFACTORY6 1.2MEASUREMENTUNCERTAINTY6 2.GENERALINFORMATION7 2.1GENERALDESCRIPTIONOFTHEEUT7 2.2DESCRIPTIONOFTHETESTMODES9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS10 2.4EQUIPMENTSLIST11 3CONDUCTEDEMISSIONMEASUREMENT12 3.1LIMIT12 3.2TESTPROCEDURE12 3.3TESTSETUP13 3.4TESTRESULTS13 4.RADIATEDEMISSIONMEASUREMENT16 4.1LIMIT16 4.2TESTPROCEDURE17 4.3TESTSETUP18 4.4TESTRESULTS19 6.20DBBANDWIDTHTEST22 6.1LIMIT22 6.2TESTPROCEDURE22 6.3TESTSETUP22 6.4TESTRESULTS23 7.ANTENNAREQUIREMENT24 7.1STANDARDREQUIREMENT24 7.2EUTANTENNA24 Page4of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0015Jan.2021AllInitialIssue Page5of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCRulesandRegulationsPart15SubpartC,Section209 Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.209(a)(f)RadiatedSpuriousEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page6of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumber:5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.98dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±3.2dB 6Allemissions,radiated(1GHz-18GHz) ±3.66dB 7Allemissions,radiated(18GHz-40GHz) ±4.31dB Page7of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFTHEEUT ProductName MagneticCharger TradeName ROUMI ModelName CWXC530 SeriesModel DWXC520 ModelDifference Theaboveproductwithsamecircuit,PCBlayout,electrical parts,materialsandwiringstructures,Appearanceshape, thematerialsofdecorativeaccessoriesissame,only differentcolor. ChannelList PleaserefertotheNote2. Operationfrequency 110-205KHz ModulationType MSK AntennaType InductiveLoopAntennawith1.0dBi PowerSupply DC5V/2A,9V/2A,12V/1.5A Hardwareversionnumber V1.0 Softwareversionnumber V1.0 ConnectingI/OPort(s) PleaserefertotheUser'sManual Note: 1. Foramoredetailedfeaturesdescription,pleaserefertothemanufacturer’sspecifications ortheUser'sManual. Page8of24ReportNo.:FCS202101014W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechn…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202101014 Above1GHzforradiatedemissiontestsetup Blow1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202101014 Conductionemissiontestingdevice

Contact Information

Applicant

Jennie Wang
[email protected]0755-28480492Fax: 0755-28480492

Technical Contact

Flux Compliance Service Laboratorykait Chen
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service Laboratorykait chen
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Roumi Technology (Shenzhen)Co.,Ltd

Magnetic Charger - FCC ID 2AYLG-WXC500 - Roumi Technology (Shenzhen)Co.,Ltd
2AYLG-WXC500

Magnetic Charger

Jan 06, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz