20W Product Name:Magnet Wireless Charger Input:5V/3A 9V/2.22A Power:5W/7.5W/10W/15W Connect Port:USB-C Packing List Magnet Wireless Charge x1 User Manual x1 Tip: 1.It is recommenden to use PD or QC 3.0 adapter. 2.Do not disassemble this product at will. 3.Do not use this product in a high temperature, humid environment, please stay away from fire and water. 4.When using the USB-C power adapter, please make sure that the cable is fully inserted into the power adapter before plugging the adapter into power outlet. 5.When using this product, please do not place metal foreign objects (such as keys, coins, batteries or jewelry) on it, otherwise it will cause abnormal charging or hotness Magnetic Charger Made in China This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment This equipment should be installed and operated with minimum distance 20cm between the radiator&your body
Modeldifferencedeclarationletter DifferencesDescription WeRoumiTechnology(Shenzhen)Co.,Ltdstate: Product: MagneticCharger ModelName WXC500,DWXC520 Theaboveproductwithsamecircuit,PCBlayout,electricalparts,materialsandwiring structures,Appearanceshape,thematerialsofdecorativeaccessoriesissame,only differentcolor, Signatory Date:12-31-2020 <Signature> Name:JennieWang Title:Manager Company:RoumiTechnology(Shenzhen)Co.,Ltd Address:Room1507,15/F,Saixiscienceandtechnologybuilding,3398BinhaiAvenue,Binhai community,Yuehaistreet,NanshanDistrict,Shenzhen,GuangdongProvince,China
C5266091_X8_Ed.1 1/1 LetterofAuthorization RoumiTechnology(Shenzhen)Co.,Ltd Company:RoumiTechnology(Shenzhen)Co.,Ltd Address:Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,NanshanDistrict, Shenzhen,GuangdongProvince,China ProductName:MagneticCharger ModelNumber:WXC500 FCCIdentifier:2AYLG-WXC500 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:JennieWangDate:December31,2020 Title:Manager Signatureofapplicant:
C5266091_X10_Ed.2 1/1 RoumiTechnology(Shenzhen)Co.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:December31,2020 Subject:RequestforConfidentiality FCCID:2AYLG-WXC500 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name:JennieWang Title: Manager
Page1of3ReportNo.:FCS202012034 Externalphotos Photo1 Photo2 Page2of3ReportNo.:FCS202012034 Photo3 Photo4 Page3of3ReportNo.:FCS202012034 Photo5 Photo6
LabelandLabelLocation FCCID:2AYLG-WXC500 L*W:10mm*7mm whitefontonaBlacklabel
Page1of2ReportNo.:FCS202012034 Photo1 Photo2 Antenna Page2of2ReportNo.:FCS202012034 Photo3 Photo4
Page1of4ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RFExposureEvaluation FCCID:2AYLG-WXC500 1MeasuringStandard KDB680106D01RFExposureWirelessChargingAppsv03 2Requirements AccordingtoKDB680106clause5,b Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcluded (1)Powertransferfrequencyislessthan1MHz. --Yes,thedeviceoperatedinthefrequencyrangefrom115KHzto205KHz (2)Outputpowerfromeachprimarycoilislessthanorequalto15watts. --Yes,themaximumoutputpoweroftheprimarycoilis15W (3)Thetransfersystemincludesonlysingleprimaryandsecondarycoils.Thisincludescharging systemsthatmayhavemultipleprimarycoilsandclientsthatareabletodetectandallowcouplingonly betweenindividualpairsofcoils. --Yes,thetransfersystemincludesonlysingleprimaryandsecondarycolis (4)Clientdeviceisplaceddirectlyincontactwiththetransmitter. --Yes,Clientdeviceisplaceddirectlyincontactwiththetransmitter (5)Mobileexposureconditionsonly(portableexposureconditionsarenotcoveredbythisexclusion). --Yes (6)TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetopsurface fromallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPElimit. --Yes,theEUTfieldstrengthlevelare50%xMPElimit. 3Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhuman exposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Page2of4ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 4TestSetup 5TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(15cmfromallsidesand20cmfrom thetop)whichisbetweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurement ofeachpoints(A,B,C,D,E)werecompleted 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v03. Remark : TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements Page3of4ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 6Equipmentlist TestEquipmentManufacturerModelNo.SN.Cal.Date ExposureLevel Tester NardaELT-400N03565Dec31,2020 Electricand Magnetic fieldprobe 100cm2 NardaELTprobe100cm2M8976Dec31,2020 7Testphoto 8TestResult E-FiledStrengthat15cmfromtheedgessurroundingtheEUT(V/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (V/m) 1%0.115-0.2051.322.120.790.74614 50%0.115-0.2051.231.790.690.65614 95%0.115-0.2051.261.920.780.62614 Stand-by0.115-0.2051.312.090.620.71614 E-FiledStrengthat20cmfromthetopoftheEUT(V/m) Page4of4ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Battery power Frequency Range(MHz) Test PositionE Limits (V/m) 1%0.115-0.2051.52614 50%0.115-0.2051.39614 95%0.115-0.2051.47614 Stand-by0.115-0.2051.41614 H-FiledStrengthat15cmfromtheedgessurroundingtheEUT(A/m) Battery power Frequency Range(MHz) Test Position A Test Position B Test Position C Test Position D Limits (A/m) 1%0.115-0.2050.320.590.810.711.63 50%0.115-0.2050.260.460.660.671.63 95%0.115-0.2050.640.490.550.621.63 Stand-by0.115-0.2050.550.520.630.561.63 H-FiledStrengthat20cmfromthetopoftheEUT(A/m) Battery power Frequency Range(MHz) Test PositionE Limits (A/m) 1%0.115-0.2050.451.63 50%0.115-0.2050.411.63 95%0.115-0.2050.381.63 Stand-by0.115-0.2050.431.63 Testedby:Reviewedby: ※※※※※ENDOFTHEREPORT※※※※※
FCCTestReport ReportNo:FCS202012034W01 Issuedfor Applicant: RoumiTechnology(Shenzhen)Co.,Ltd Address: Room1507,15/F,Saixiscienceandtechnologybuilding, 3398BinhaiAvenue,Binhaicommunity,Yuehaistreet, NanshanDistrict,Shenzhen,GuangdongProvince,China ProductName: MagneticCharger BrandName: ROUMI ModelName: WXC500 SeriesModel: DWXC520 FCCID: 2AYLG-WXC500 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-Tech Industrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com Page2of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:RoumiTechnology(Shenzhen)Co.,Ltd Address......................................: Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,Nanshan District,Shenzhen,GuangdongProvince,China Manufacture'sName ................ :RoumiTechnology(Shenzhen)Co.,Ltd Address......................................: Room1507,15/F,Saixiscienceandtechnologybuilding,3398 BinhaiAvenue,Binhaicommunity,Yuehaistreet,Nanshan District,Shenzhen,GuangdongProvince,China ProductDescription ProductName ........................... :MagneticCharger BrandName ............................. :ROUMI ModelName .............................. :WXC500 SeriesModel .............................. :DWXC520 TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section209 TestProcedure .......................... :ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedFCS,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFCS,thisdocument maybealteredorrevisedbyFCS,personalonly,andshallbenotedintherevisionofthedocument.. DateofTest .................................. : Date(s)ofperformanceoftests.:23Dec.2020~31Dec.2020 DateofIssue.................................:31Dec.2020 TestResult.....................................:Pass Testedby: (ChrisChen) Reviewedby: (JackChen) Approvedby: (Andyyue) Page3of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS5 1.1TESTFACTORY6 1.2MEASUREMENTUNCERTAINTY6 2.GENERALINFORMATION7 2.1GENERALDESCRIPTIONOFTHEEUT7 2.2DESCRIPTIONOFTHETESTMODES9 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS10 2.4EQUIPMENTSLIST11 3CONDUCTEDEMISSIONMEASUREMENT12 3.1LIMIT12 3.2TESTPROCEDURE12 3.3TESTSETUP13 3.4TESTRESULTS13 4.RADIATEDEMISSIONMEASUREMENT16 4.1LIMIT16 4.2TESTPROCEDURE17 4.3TESTSETUP18 4.4TESTRESULTS19 6.20DBBANDWIDTHTEST22 6.1LIMIT22 6.2TESTPROCEDURE22 6.3TESTSETUP22 6.4TESTRESULTS23 7.ANTENNAREQUIREMENT24 7.1STANDARDREQUIREMENT24 7.2EUTANTENNA24 Page4of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com RevisionHistory Rev.IssueDateEffectPageContents 0031Dec.2020AllInitialIssue Page5of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.SUMMARYOFTESTRESULTS FCCRulesandRegulationsPart15SubpartC,Section209 Standard Section TestItemJudgmentRemark 15.207ConductedEmissionPASS-- 15.209(a)(f)RadiatedSpuriousEmissionPASS-- 15.215(c)20dBBandwidthPASS-- 15.203AntennaRequirementPASS-- NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport (2)AlltestsareaccordingtoANSIC63.10-2013 Page6of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 1.1TESTFACTORY CompanyName:FluxComplianceServiceLaboratory Address: Room105FloorBaohaoTechnologyBuilding1NO.15Gongye WestRoadHi-TechIndustrial,SongshanlakeDongguan Telephone:+86-769-27280901 Fax:+86-769-27280901 FCCTestFirmRegistrationNumber:514908 Designationnumber:CN0127 A2LAaccreditationnumber:5545.01 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedona standarduncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceof approximately95%. No.ItemUncertainty 1RFoutputpower,conducted±0.71dB 2UnwantedEmissions,conducted±2.98dB 3ConductedEmission(9KHz-150KHz) ±4.13dB 4ConductedEmission(150KHz-30MHz) ±4.74dB 5Allemissions,radiated(<1G)30MHz-1000MHz ±3.2dB 6Allemissions,radiated(1GHz-18GHz) ±3.66dB 7Allemissions,radiated(18GHz-40GHz) ±4.31dB Page7of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:769-27280901Fax:769-27280901http://www.fcs-lab.com 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFTHEEUT ProductName MagneticCharger TradeName ROUMI ModelName WXC500 SeriesModel DWXC520 ModelDifference Theaboveproductwithsamecircuit,PCBlayout,electrical parts,materialsandwiringstructures,Appearanceshape, thematerialsofdecorativeaccessoriesissame,only differentcolor. ChannelList PleaserefertotheNote2. Operationfrequency 115-205KHz ModulationType MSK AntennaType InductiveLoopAntennawith0dBi PowerSupply Input:DC5V/3A,DC9V/2.22A Output:5W/7.5W/10W/15W Hardwareversionnumber V1.3 Softwareversionnumber 82bf ConnectingI/OPort(s) PleaserefertotheUser'sManual Note: 1. Foramoredetailedfeaturesdescription,pleaserefertothemanufacturer’sspecifications ortheUser'sManual. Page8of24ReportNo.:FCS202012034W01 FluxComplianceServiceLaboratory Room105…
Text truncated - open the document above for the full version.
Page 1 of2ReportNo.:FCS202012034 Above1GHzforradiatedemissiontestsetup Blow1GHzforradiatedemissiontestsetup Page 2 of2ReportNo.:FCS202012034 Conductionemissiontestingdevice
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |

Magnetic Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz