FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Beijing Jingyunmake Technology Co., Ltd./
  3. 2AYQ3-HT-M

2AYQ3-HT-MWireless Mouse

Beijing Jingyunmake Technology Co., Ltd.
Wireless Mouse - FCC ID 2AYQ3-HT-M - Beijing Jingyunmake Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 24, 2022
Application Purpose
Original Equipment
Date of Application
Apr 24, 2022
Equipment Note
Wireless Mouse
Frequency Range
2405.00000000 - 2475.00000000
Company
Beijing Jingyunmake Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Thisisadual-modemouse,withUSBcablefunctionand2.4Gwireless communication function. The mouse has left button, right button,middle button,cursormovement,scrollup,scrolldown,DPILOP,forwardbutton,backward button,powerswitchfunction. First plug the matched wireless receiver into the PC USB port, then turn the matchedmousepowerswitchto“ON”.IfthemouseLOGOisgreen,itindicates thatthemouseisconnectedtothewirelessreceiver,andmouseandreceiverhas achieved2.4Gwirelesscommunicationfunction. Mousewilltransfertheclickwhich isonleftbutton,rightbutton,middlebutton,cursormovement,scrollup,scroll down,DPILOP,forwardbutton,backwardbuttontothewirelessreceiver.Afterthe wireless receiver receives the relevant instructions which arefrom mouse, it will convertthemtotherelevantcomputerrecognitioninstructions,soastoachieve theclickinthegameandofficeandthefunctionofrightbutton,middlebutton, cursor movement, scroll up, scroll down, DPI LOP , forward button, backward button.Whenthemousepowerswitchmovesto“ OFF”,themousestopsworking, thereceiverisinawaitingstate,andthereceiverstopstransmittingsignalstothe PC.Itwillnotbegintheinteractivecommunicationwithcomputeruntilamatched mousesignalisreceived. First,insertthemouseintotheMicroUSBendofUSBCable,theninsertthe USBportofUSBCableintotheUSBportofPC.Themouselogowilllightupand the mouse will achieve the functions of game and work. It willalso charge the mouseatthesametime.IfyouunplugtheUSBCable,mousewillstopworking. FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐‐ Reorient or relocate the receiving antenna. ‐‐ Increase the separation between the equipment and receiver. ‐‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐‐ Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement.

Cover Letter(s)

Co m Ad d Dist Pr o Mo d HSK Pr o We act We an d issu our Sig Na m Title Com Be mpany: Bei dress: No. trict, Beijing oduct Name del Numbe K oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: ijing Ji ijing Jingyu 346, Kehai g, China e: Wireless er(s): Hati, H ription: Wi MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s xiulin zh a ceo Beijing Ji ingyun Agen nmake Tec Avenue, Ea Mouse HT-M, HT-S reless Mous bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect ang ngyunmak nmake T nt Auth chnology Co ast District, S, HT-X, HS se Boulder C o erning the c allowed to f regulatory a cation. Any t as acts of ke Technolo Techno horizat o., Ltd. Economic SK Plus, HT ourt, Pleasa certification forward all i agencies as and all acts our own. ogy Co., Lt ology C tion Developme T-M Pro, HT anton, Califo of above na information s required a s carried ou Date: td. Co., Ltd ent Zone, To T-S Plus, HS ornia 94566 amed equip related to t nd to discu ut by MiCOM Apr. 22, 20 d. ongzhou SK Pro, SK 6, USA, to pment. the approva ss any M Labs on 022 KS, al

Cover Letter(s)

Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b It is ou r corresp docume authoriz Sincer e Signat u Name: x Title: ce of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2AYQ3-H om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schema Block D Parts Lis Operatio Tune-up r understand pondence du ents and thi zation is iss ely, ure: xiulin zhang eo Beijin ing Techno cations Com s Road 046 for Confiden HT-M Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp atic Diagram iagram st onal Descri p Procedure ding that all uring the ce s informatio sued. g ng Jingyun logy mmission ntiality the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption e l measurem ertification re on will be av nmake Te ssion’s rule old the follow nitely. m and equi e equipmen ould give co ment test rep eview proce vailable for chnology s Title 47 S wing attach pment desc nt. The publ ompetitors a ports, FCC ess cannot public revi e Co., Ltd. Sections §0. hment(s) as criptions an ic disclosu r an unfair ad ID label for be granted ew once the Date: Apr. 457 and § 0 confidentia d are consi re of these d vantage in mat and as confide n e grant of eq 22, 2022 0.459, we al dered as documents the market . ntial quipment .

Cover Letter(s)

Model Difference Declaration To Whom It May Concern, We, Beijing Jingyunmake Technology Co., Ltd.(Wireless Mouse) ; Model Number:Hati, HT-M, HT-S, HT-X, HSK Plus, HT-M Pro, HT-S Plus , HSK Pro, SKS, HSK; AAll model’s the function, software and electric circuit are the same, only with a product color and model named different. Test sample model: Hati Please contact me if you have any question. Name: xiulin zhang Date: Apr. 22, 2022 Title: ceo Signature of applicant:

External Photos

Annex A External Photos Report No.: HK2203010781‐E Page 1 of 4 Report No.: HK2203010781‐E Page 2 of 4 Report No.: HK2203010781‐E Page 3 of 4 Report No.: HK2203010781‐E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Ca. 5mm x 10mm Label Location FCC ID: 2AYQ3‐HT‐M

Internal Photos

Annex B Internal Photos Report No.: HK2203010781‐E Page 1 of 3 Report No.: HK2203010781‐E Page 2 of 3 Antenna Report No.: HK2203010781‐E Page 3 of 3

Test Report

Page 1 of 28 Report No.: HK2203010781-E FCC TEST REPORT Test report On Behalf of Beijing Jingyunmake Technology Co., Ltd. For Wireless Mouse Model No.: Hati, HT-M, HT-S, HT-X, HSK Plus, HT-M Pro, HT-S Plus, HSK Pro, SKS, HSK FCC ID: 2AYQ3-HT-M Prepared for : Beijing Jingyunmake Technology Co., Ltd. No. 346, Kehai Avenue, East District, Economic Development Zone, Tongzhou District, Beijing, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Date of Test: Mar. 01, 2022 ~ Mar. 07, 2022 Date of Report: Mar. 07, 2022 Report Number: HK2203010781-E Page 2 of 28 Report No.: HK2203010781-E TEST RESULT CERTIFICATION Applicant’s name ................. : Beijing Jingyunmake Technology Co., Ltd. Address ................................. : No. 346, Kehai Avenue, East District, Economic Development Zone, Tongzhou District, Beijing, China Manufacture's Name ............ : Beijing Jingyunmake Technology Co., Ltd. Address ................................. : No. 346, Kehai Avenue, East District, Economic Development Zone, Tongzhou District, Beijing, China Product description Trade Mark: G-Wolves, G-Sevlow, Peepeeboy Product name ........................... : Wireless Mouse Model and/or type reference : Hati, HT-M, HT-S, HT-X, HSK Plus, HT-M Pro, HT-S Plus, HSK Pro, SKS, HSK Standards ............................. : FCC Rules and Regulations Part 15 Subpart C Section 15.249 ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Mar. 01, 2022 ~ Mar. 07, 2022 Date of Issue ........................................... : Mar. 07, 2022 Test Result .............................................. : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 28 Report No.: HK2203010781-E Table of Contents Page 1 . Test Summary 5 1.1 . Test Procedures And Results 5 1.2 . Information of the Test Laboratory 5 1.3 . Measurement Uncertainty 5 2 . General Information 6 2.1 . General Description Of EUT 6 2.2 . Operation of EUT during testing 7 2.3 . Description Of Test Setup 8 2.4 . Measurement Instruments List 9 3 . Conducted Emissions Test 10 3.1. Conducted Power Line Emission Limit 10 3.2. Test Setup 10 3.3. Test Procedure 10 3.4. Test Result 11 4. Radiated Emission Test 13 4.1. Radiation Limit 13 4.2. Test Setup 13 4.3. Test Procedure 14 4.4. Test Result 14 5. Band Edge 20 5.1. Limits 20 5.2. Test Procedure 20 5.3. Test Result 21 6. Occupied Bandwidth Measurement 23 6.1. Test Setup 23 6.2. Test Procedure 23 6.3. Measurement Equipment Used 23 6.4. Test Result 23 7. Antenna Requirement 25 8. Photograph Of Test 26 9. Photos Of The EUT 28 Page 4 of 28 Report No.: HK2203010781-E ** Modified History ** Revision Description Issued Data Remark Revision 1.0 Initial Test Report Release Mar. 07, 2022 Jason Zhou Page 5 of 28 Report No.: HK2203010781-E 1. Test Summary 1.1. Test Procedures And Results DESCRIPTION OF TEST SECTION NUMBERRESULT CONDUCTED EMISSIONS TEST 15.207 COMPLIANT RADIATED EMISSION TEST 15.249(a) /15.209 COMPLIANT BAND EDGE 15.249(d)/15.205 COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT 15.215(c) COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT 1.2. Information of the Test Laboratory Shenzhen HUAK Testing Technology Co., Ltd. Add.: 1-2/F., Building B2, Junfeng Zhongcheng Zhizao Innovation Park, Heping, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Testing Laboratory Authorization: A2LA Accreditation Code is 4781.01. FCC Designation Number is CN1229. Canada IC CAB identifier is CN0045. CNAS Registration Number is L9589. 1.3. Measurement Uncertainty Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.71dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 4.26dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 3.90dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.28dB, k=2 Page 6 of 28 Report No.: HK2203010781-E 2. General Information 2.1. General Description Of EUT Equipment Wireless Mouse Model Name Hati Serial Model HT-M, HT-S, HT-X, HSK Plus, HT-M Pro, HT-S Plus, HSK Pro, SKS, HSK Model Difference All model’s the function, software and electric circuit are the same, only with a product color and model named different. Test sample model: Hati FCC ID 2AYQ3-HT-M Antenna Type PCB Antenna Antenna Gain -1dBi Operation frequency 2405-2475MHz Number of Channels 16CH Modulation Type GFSK Power Source DC 3.7V from battery or DC 5V from USB Power Rating DC 3.7V from battery or DC 5V from USB Page 7 of 28 Report No.: HK2203010781-E 2.1.1. Carrier Frequency of Channels Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 1 2405 7 2436 13 2463 2 2408 8 2439 14 2466 3 2414 9 2441 15 2471 4 2419 10 2445 16 2475 5 2422 11 2453 6 2426 12 2459 / 2.2. Operation of EUT during testing Operating Mode The mode is used: Transmitting mode Low Channel: 2405MHz Middle Channel: 2441MHz High Channel: 2475MHz Page 8 of 28 Report No.: HK2203010781-E 2.3. Description Of Test Setup Operation of EUT during conducted testing: AC Plug Operation of EUT during radiation below 1GHz testing: AC Plug Operation of EUT during radiation above 1GHz testing PC information Model: ThinkPad E450 Input: 20V, 2.25A/3.25A The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was max…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Model:Hati Radiated Emission Conducted Emission

Contact Information

Applicant

xiulin zhang
[email protected]18501059111Fax: 18501059111

Technical Contact

Beijing Jingyunmake Technology Co., Ltd.
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Beijing Jingyunmake Technology Co., Ltd.

Wireless Mouse - FCC ID 2AYQ3-LONGRX001 - Beijing Jingyunmake Technology Co., Ltd.
2AYQ3-LONGRX001

Wireless Mouse

Jan 20, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Mouse - FCC ID 2AYQ3-HATI - Beijing Jingyunmake Technology Co., Ltd.
2AYQ3-HATI

Wireless Mouse

Jan 20, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter