
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
AC60P Portable Power Station User Manual Please Read This Manual Before Use And Follow Its Guidance. Keep This Manual For Future Reference. 1. Charge the unit before first use. 2. Do not use solar panels with open circuit voltage higher than 28V. Solar input voltage range for the unit is DC 12V~28V. 3. Charge the unit when the SoC drops below 5%. If the SoC drops to 0, power off the unit and charge it for at least 30mins before restarting. 4. The unit is for off-grid use only. Do not connect its AC output to the grid. 5. If not used for more than 3 months, charge the unit to 40%~60% SoC and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months. Warning Thank You! Thank you for making BLUETTI a part of your family. From the very beginning, BLUETTI has tried to stay true to a sustainable future through green energy storage solutions for both indoor and outdoor use while delivering an exceptional eco-f riendly experience for our homes and our world. That's why BLUETTI makes its presence in 70+ countries and is trusted by millions of customers across the globe. Franch Germany Netherlands Safety Instructions General Safety Handling Storage and Usage What’s In The Box Product Overview Diagram Specifications Operating Instructions Buttons LCD Screen Charging Discharging Connect AC60P and B80P BLUETTI App Appendix FAQs Troubleshooting Abbreviations FCC Warning Important Instructions Contents 1 1.1 1.2 1.3 2 3 3.1 3.2 4 4.1 4.2 4.3 4.4 4.5 4.6 5 5.1 5.2 5.3 5.4 5.5 05 05 07 07 08 10 10 11 12 12 14 15 17 18 18 19 19 20 21 22 24 1. Safety Instructions Read this manual for instructions on the proper use and safety information for the unit. Follow the warnings and instructions marked on the unit and its accessories. Pay attention to the "Instruction", "Caution", "Warning" and "Danger" symbols in this manual, and follow the instructions carefully to avoid injury or damage. The Safety Requirements provided herein are for illustrative purposes that include but are not limited to those listed in this manual. Actual operation shall comply with all applicable safety standards. If you have any questions, feel f ree to contact BLUETTI support or your local BLUETTI dealers. 1.1. General Safety • Always operate or store the unit in the conditions specified in this manual. • The installation and ambient conditions must comply with the regulations in the relevant international, national or regional standards. • Unauthorized disassembly, alteration of the equipment or modification of the software code is not allowed. BLUETTI shall not be liable for the following circumstances: • Equipment damage caused by force majeure, such as earthquake, fire, storm, flood, mudslide, etc. • Damage or loss during transportation. • Damage caused by storage conditions that do not meet the requirements specified in this manual. • Damage to the hardware or data of the equipment due to customer negligence, improper operation or intentional damage. • Damage to the system caused by a third party or the customer, including handling and installation that does not meet the requirements specified in this manual. • This product is not suitable for providing electrical service for equipment and machines that are highly dependent on the reliability of electrical power supply and that involve personal safety, such as atomic energy, aviation, medical, etc. Poweroak will not be held responsible for any personal safety accidents, fire accidents, equipment failures, etc. caused by using this product to supply power to the above equipment and machines. • Damage caused by adjustment, alteration or removal of identification marks. To avoid danger, please regulate the operation in the following manner • Do not install, use and maintain the unit in adverse weather conditions such as lightning, rain, snow and strong breezes (including but not limited to handling and operating the unit, plugging and unplugging signal connections to outdoor facilities, working at height, outdoor installations, etc.). JUST POWER ON05 • The transportation, wiring and maintenance shall comply with all applicable laws, regulations and standards. • User-provided materials and tools required shall meet the requirements specified in applicable laws, regulations and relevant standards. • Always turn off the power source before starting any electrical work. • Do not clean the unit with water. • Do not disassemble, modify, tamper with or repair the unit on your own. • Regularly inspect the unit and its accessories for damage or deterioration. • Use a tester to check for the presence of dangerous voltage before touching any conductor or terminal. • If the unit’s shell is cracked during transportation or use, do not use it and contact BLUETTI support or your local BLUETTI dealers. • Use a dry powder extinguisher if the unit catches fire. • In case of fire, EVACUATE the building or affected area immediately, activate the closest FIRE ALARM system and CALL 9-1-1 or your local emergency phone number. • Use genuine cables and accessories provided by BLUETTI. • Keep the unit away f rom heat sources or high temperatures, and do not expose it to direct sunlight. • Do not store the unit with flammable liquids, gases, or explosive materials. • Make sure the area where you are using the unit is well ventilated and spacious. • Do not block or cover the vents of the unit as this may cause irreversible damage to it. • Use the unit for its intended purpose and avoid stacking objects on top of it during storage or use. • Do not move the unit during operation as the vibrations and shocks associated with movement may cause damage to the internal hardware. • In case of malfunction, turn off the unit immediately and contact BLUETTI support or your local BLUETTI dealers if this manual cannot adequately explain the malfunction to you. • Do not place the unit on an unstable or inclined surface. • Do not insert foreign objects into any port and vent of the unit…
Text truncated - open the document above for the full version.
SHENZHEN POWEROAK NEWENER CO., LTD F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-01-2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AYT3-AC60P Product Name: Portable Power Station Model Name: AC60P [SHENZHEN POWEROAK NEWENER CO., LTD] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Cara Zou)
SHENZHEN POWEROAK NEWENER CO., LTD F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-01-2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AYT3-AC60P Product Name: Portable Power Station Model Name: AC60P [SHENZHEN POWEROAK NEWENER CO., LTD] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Cara Zou)
SHENZHEN POWEROAK NEWENER CO., LTD F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Declaration Letter Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 9/5/2023 FCC ID: 2AYT3-AC60P Pursuant to KDB 680106 of the SHENZHEN POWEROAK NEWENER CO., LTD hereby declare our product which is an inductive wireless power transfer applications that meet all of the following requirements are not required to submit a KDB inquiry for devices approved usinga PAG for equipment approved using certification to address RF exposure compliance. 1) Power transfer frequency is 110.5KHz-205KHz which is less than1 MHz 2) Output power from each primary coil is equal to 15 watts max 3) The system may consist of more than one source primary coils, charging one clients. 4) Client device is placed directly in contact with the transmitter 5) The EUT is a mobile device. 6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yours sincerely, Name: Cara Zou Title: Manager
SHENZHEN POWEROAK NEWENER CO., LTD F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Sep. 01, 2023 Subject; Request for Confidentiality FCC ID: 2AYT3-AC60P To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Parts List Antenna Specification FCC_Confidential Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Cara Zou Title: Manager
Agent Authorization Company: SHENZHEN POWEROAK NEWENER CO., LTD Address: F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Product Name: Portable Power Station Model Number(s): AC60P Product Description: Portable Power Station We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Aug. 24, 2023 Name: Cara Zou Title: Manager Company: SHENZHEN POWEROAK NEWENER CO., LTD
Report No.: AGC01741230702AP03 Page 1 of 5 EXTERNAL PHOTOS TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC01741230702AP03 Page 2 of 5 FRONT VIEW OF EUT BACK VIEW OF EUT Report No.: AGC01741230702AP03 Page 3 of 5 LEFT VIEW OF EUT RIGHT VIEW OF EUT Report No.: AGC01741230702AP03 Page 4 of 5 PORT VIEW-1 OF EUT PORT VIEW-2 OF EUT Report No.: AGC01741230702AP03 Page 5 of 5 PORT VIEW-3 OF EUT PORT VIEW-4 OF EUT ****************************************End of Report*************************************
+0/-0.3mm Portable Power Station Model No.: AC60P Battery Capacity: 504Wh, 22.4V 22.5Ah +0/-0.3mm 120mm 5 R3mm 60mm MADE IN CHINAP/N:17.0301.1256-01A1 120*60mm C:0 M:0 Y:0 K:25 Output: AC: 120V 50/60Hz, 600W Max. USB-A: 5V 3A USB-C: 5/9/12/15/20V 3A; 20V 5A (With E-Marker chip built in) Wireless Charging: 5/7.5/10/15W Cigarette Lighter Port: 12V 10A AC & DC output: 600W Total Battery Expansion: 22.4V 30A Total CAN ICES-003 (B) / NMB-003 (B) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Discharging Temperature: -20 o C-40 o C Charging Temperature: 0 o C-40 o C Working Humidity: 10%-90% Input: AC: 120V 50/60Hz, 10A Max. DC/PV: 12V-28V 8A, 200W Max. SHENZHEN POWEROAK NEWENER CO., LTD. Address: F19, BLD No.1, Kaidaer, Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China FCC ID: 2AYT3-AC60P IC: 29079-AC60P Label location map
Report No.: AGC01741230702AP03 Page 1 of 12 INTERNAL PHOTOS OPEN VIEW-1 OF EUT OPEN VIEW-2 OF EUT Report No.: AGC01741230702AP03 Page 2 of 12 INTERNAL VIEW -1 OF EUT INTERNAL VIEW-2 OF EUT Report No.: AGC01741230702AP03 Page 3 of 12 INTERNAL VIEW-3 OF EUT INTERNAL VIEW-4 OF EUT Report No.: AGC01741230702AP03 Page 4 of 12 INTERNAL VIEW-5 OF EUT INTERNAL VIEW-6 OF EUT Report No.: AGC01741230702AP03 Page 5 of 12 INTERNAL VIEW-7 OF EUT INTERNAL VIEW-8 OF EUT Report No.: AGC01741230702AP03 Page 6 of 12 INTERNAL VIEW-9 OF EUT INTERNAL VIEW-10 OF EUT Report No.: AGC01741230702AP03 Page 7 of 12 INTERNAL VIEW-11 OF EUT INTERNAL VIEW-12 OF EUT Report No.: AGC01741230702AP03 Page 8 of 12 INTERNAL VIEW-13 OF EUT INTERNAL VIEW-14 OF EUT Report No.: AGC01741230702AP03 Page 9 of 12 INTERNAL VIEW-15 OF EUT INTERNAL VIEW-16 OF EUT Report No.: AGC01741230702AP03 Page 10 of 12 INTERNAL VIEW-17 OF EUT INTERNAL VIEW-18 OF EUT BT Antenna Report No.: AGC01741230702AP03 Page 11 of 12 INTERNAL VIEW-19 OF EUT INTERNAL VIEW-20 OF EUT WPT Antenna 20cm 44cm Report No.: AGC01741230702AP03 Page 12 of 12 INTERNAL VIEW-21 OF EUT BATTERY VIEW OF EUT ****************************************End of Report*************************************
Page 1 of 14 RF Exposure Report Report No.: AGC01741230702FH01 FCC ID : 2AYT3-AC60P APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Portable Power Station BRAND NAME : BLUETTI MODEL NAME : AC60P APPLICANT : SHENZHEN POWEROAK NEWENER CO., LTD DATE OF ISSUE : Aug. 30, 2023 STANDARD(S) : KDB680106 D01 RF Exposure Wireless Charging Base App v03r01 REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01741230702FH01 Page 2 of 14 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 30, 2023 Valid Initial Release Report No.: AGC01741230702FH01 Page 3 of 14 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 4 2. PRODUCT INFORMATION .............................................................................................................................. 4 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 5 2.2 TEST FREQUENCY LIST ........................................................................................................................ 5 3. TEST ENVIRONMENT ..................................................................................................................................... 6 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 6 3.2 TEST FACILITY ....................................................................................................................................... 6 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 7 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 7 3.5 LIST OF EQUIPMENTS USED ............................................................................................................... 7 4. EQUIPMENT USED IN TESTED SYSTEM ...................................................................................................... 8 5. DESCRIPTION OF TEST MODES ................................................................................................................... 9 6. RF EXPOSURE MEASUREMENT ................................................................................................................. 10 6.1 REFER EVALUATION METHOD ........................................................................................................... 10 6.2 TEST LIMITS ......................................................................................................................................... 10 6.3 MEASUREMENT SETUP ...................................................................................................................... 11 6.4 MEASUREMENT PROCEDURE ........................................................................................................... 12 6.5 MEASUREMENT RESULTS.................................................................................................................. 13 APPENDIX I: PHOTOGRAPHS OF TEST SETUP ............................................................................................ 14 Report No.: AGC01741230702FH01 Page 4 of 14 1. GENERAL INFORMATION Applicant SHENZHEN POWEROAK NEWENER CO., LTD Address F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Manufacturer SHENZHEN POWEROAK NEWENER CO., LTD Address F19, BLD No.1, Kaidaer Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China Factory Huizhou PowerOak Innovation Co., Ltd Address (No.1 Workshop)Longsheng 5th Road, Laoshe Village, Dayawan West Zone, Huizhou, Guangdong, China Product Designation Portable Power Station Brand Name BLUETTI Test Model AC60P Deviation from Standard No any deviation from the test method Date of receipt of test item Jul. 18, 2023 Date of Test: Jul. 19, 2023~Aug. 24, 2023 Test Result Pass Prepared By Alan Duan (Project Engineer) Aug. 30, 2023 Reviewed By Calvin Liu (Reviewer) Aug. 30, 2023 Approved By Max Zhang Authorized Officer Aug. 30, 2023 Report No.: AGC01741230702FH01 Page 5 of 14 2. PRODUCT INFORMATION 2.1 PRODUCT TECHNICAL DESCRIPTION Equipment Specification WPT Frequency Band 110.5kHz-205kHz Operation Frequency 130kHz Hardware Version AC60_U2 V5.0 Software Version V2073 Modulation Type ASK Number of channels 1 Field Strength of Fundamental 73.95dBuV/m (Max) at 3m distance Antenna Designation Coil Antenna Antenna Gain 0dBi Input Rating AC: 120V~50/60Hz, 10A Max DC/PV:12V-28V⎓8A, 200W Max Output Rating AC: 120V~50/60Hz, 600W Max. USB-A: 5V⎓3A USB-C: 5/9/12/15/20V⎓3A; 20V⎓5A(E-Marker chip built-in) Wireless Charge: 5/7.5/10/15W Cigarette Lighter Socket: 12V⎓10A AC and DC output: 600W Total Battery Expansion: 22.4⎓30A Total 2.2 TEST FREQUENCY LIST Frequency Band Channel Number Frequency 110.5kHz-205kHz 01 130kHz Report No.: AGC01741230702FH01 Page 6 of 14 3. TEST ENVIRONMENT 3.1 ADDRESS OF THE TEST LABORATORY Laboratory: Attestation of Global Compliance (Shenzhen) Co., Ltd. Address: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3.2 TEST FACILITY The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L5488 Attestation of Global Compliance (Shenzhen) Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025: 2017 General Requirements) for the Competence of Testing and Calibration Laboratories. A2LA-Lab Cert. No.: 5054.02 Attestation of Global Compliance (Shenzhen) Co., Ltd. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical…
Text truncated - open the document above for the full version.
Page 1 of 30 FCC Test Report Report No.: AGC01741230702FR02 FCC ID : 2AYT3-AC60P APPLICATION PURPOSE Original Equipment PRODUCT DESIGNATION : Portable Power Station BRAND NAME : BLUETTI MODEL NAME : AC60P APPLICANT : SHENZHEN POWEROAK NEWENER CO., LTD DATE OF ISSUE : Aug. 30, 2023 STANDARD(S) : FCC Part 15 Subpart C REPORT VERSION : V 1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC01741230702FR02 Page 2 of 30 REPORT REVISE RECORD Report Version Revise Time Issued Date Valid Version Notes V1.0 / Aug. 30, 2023 Valid Initial Release Report No.: AGC01741230702FR02 Page 3 of 30 TABLE OF CONTENTS 1. GENERAL INFORMATION .............................................................................................................................. 5 2. PRODUCT INFORMATION .............................................................................................................................. 5 2.1 PRODUCT TECHNICAL DESCRIPTION ................................................................................................ 6 2.2 TEST FREQUENCY LIST ........................................................................................................................ 6 2.3 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................. 7 2.4 TEST METHODOLOGY .......................................................................................................................... 7 2.5 SPECIAL ACCESSORIES ....................................................................................................................... 7 2.6 EQUIPMENT MODIFICATIONS .............................................................................................................. 7 2.7 ANTENNA REQUIREMENT .................................................................................................................... 7 3. TEST ENVIRONMENT ..................................................................................................................................... 8 3.1 ADDRESS OF THE TEST LABORATORY .............................................................................................. 8 3.2 TEST FACILITY ....................................................................................................................................... 8 3.3 ENVIRONMENTAL CONDITIONS........................................................................................................... 9 3.4 MEASUREMENT UNCERTAINTY .......................................................................................................... 9 3.5 LIST OF EQUIPMENTS USED ............................................................................................................. 10 4.SYSTEM TEST CONFIGURATION ................................................................................................................. 11 4.1 EUT CONFIGURATION ......................................................................................................................... 11 4.2 EUT EXERCISE ..................................................................................................................................... 11 4.3 CONFIGURATION OF TESTED SYSTEM ............................................................................................ 11 4.4 EQUIPMENT USED IN TESTED SYSTEM........................................................................................... 11 4.5 SUMMARY OF TEST RESULTS ........................................................................................................... 12 5. DESCRIPTION OF TEST MODES ................................................................................................................. 13 6. FIELD STRENGTH OF FUNDAMENTAL ...................................................................................................... 14 6.1 PROVISIONS APPLICABLE .................................................................................................................. 14 6.3 FIELD STRENGTH CALCULATION ...................................................................................................... 16 6.4 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 17 6.5 MEASUREMENT RESULTS.................................................................................................................. 18 7. 20 DB BANDWIDTH ....................................................................................................................................... 24 7.1 PROVISIONS APPLICABLE .................................................................................................................. 24 7.2 MEASUREMENT PROCEDURE ........................................................................................................... 24 7.3 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 24 7.4 MEASUREMENT RESULTS.................................................................................................................. 25 8. AC POWER LINE CONDUCTED EMISSION TEST ...................................................................................... 26 8.1 LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................................... 26 Report No.: AGC01741230702FR02 Page 4 of 30 8.2 MEASUREMENT SETUP (BLOCK DIAGRAM OF CONFIGURATION) ............................................... 26 8.3 PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST .......................................... 27 8.4 FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ........................................................ 27 8.5 MEASUREMENT RESULTS.................................................................................................................. 28 APPENDIX I: PHOTOGRAPHS OF TEST SETUP .........................................................................…
Text truncated - open the document above for the full version.
Report No.: AGC01741230702AP02 Page 1 of 11 TEST SETUP PHOTOS BT RADIATED EMISSION TEST SETUP BELOW 1GHz WITH BATTERY RADIATED EMISSION TEST SETUP BELOW 1GHz WITH AC Power Report No.: AGC01741230702AP02 Page 2 of 11 RADIATED EMISSION TEST SETUP ABOVE 1GHz WITH BATTERY RADIATED EMISSION TEST SETUP ABOVE 1GHz WITH AC Power Report No.: AGC01741230702AP02 Page 3 of 11 AC POWER LINE CONDUCTED TEST SETUP RF CONDUCTED TEST SETUP Report No.: AGC01741230702AP02 Page 4 of 11 WPT RADIATED EMISSION TEST SETUP BELOW 30MHz WITH BATTERY RADIATED EMISSION TEST SETUP BELOW 30MHz WITH AC Power Report No.: AGC01741230702AP02 Page 5 of 11 RADIATED EMISSION TEST SETUP BELOW 1GHz WITH BATTERY RADIATED EMISSION TEST SETUP BELOW 1GHz WITH AC Power Report No.: AGC01741230702AP02 Page 6 of 11 AC POWER LINE CONDUCTED TEST SETUP Report No.: AGC01741230702AP02 Page 7 of 11 RF HEALTH ASSESSMENT TEST PHOTOS Position E WITH BATTERY Position E WITH AC Power Report No.: AGC01741230702AP02 Page 8 of 11 Position A WITH BATTERY Position A WITH AC Power Report No.: AGC01741230702AP02 Page 9 of 11 Position B WITH BATTERY Position B WITH AC Power Report No.: AGC01741230702AP02 Page 10 of 11 Position C WITH BATTERY Position C WITH AC Power Report No.: AGC01741230702AP02 Page 11 of 11 Position D WITH BATTERY Position D WITH AC Power ****************************************End of Report*************************************
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1105 MHz - 0.205 MHz | - |

DC-DC Charger
Equipment Class
DTS - Digital Transmission SystemPortable Power Station
Equipment Class
DTS - Digital Transmission SystemRefrigerator
Equipment Class
DTS - Digital Transmission SystemDC-DC Charger
Equipment Class
DTS - Digital Transmission SystemPortable Power Station
Equipment Class
DTS - Digital Transmission System