Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 25, 2023
Application Purpose
Original Equipment
Date of Application
Sep 19, 2023
Equipment Note
RenuSpa iO
Frequency Range
0.11600000 - 0.11600000
Company
NSE Products, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

™ USER’S MANUAL PMS Black CMYK PMS CG9 PMS Color PMS Color PMS Color PMS Color PMS Color File Name: 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual Formula: Device Master Record (DMR) Dimensions and Colors 0.0” length6.0” width4.0” height 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 101_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 19/5/23 15:569/5/23 15:56 TABLE OF CONTENTS System Contents 1 Device Components 2 Intended Use 3 Description 3 Contraindications, Warnings, Precautions, and 4 Adverse Reactions Before You Begin 7 Charging Your Nu Skin ® RenuSpa iO™ 8 Using Your Nu Skin RenuSpa iO 10 Cleaning and Caring for Your 12 Nu Skin RenuSpa iO Troubleshooting 12 Maintenance and Disposal 13 Replacement and Warranty 14 Patents 14 Technical Description and Specifications 15 Symbols 22 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 201_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 29/5/23 15:569/5/23 15:56 1 SYSTEM CONTENTS Nu Skin ® RenuSpa iO™ device Quick Start Guide User Manual Nu Skin Conductive Gel Wireless Charger 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 101_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 19/5/23 15:569/5/23 15:56 2 DEVICE COMPONENTS Indicator Lights Power Button Battery Indicator Metallic Nodes 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 201_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 29/5/23 15:569/5/23 15:56 3 INTENDED USE The Nu Skin ® RenuSpa iO™ device is intended for body skin stimulation and is indicated for over-the-counter cosmetic use. DESCRIPTION Nu Skin RenuSpa iO emits an electrical current conducted to the skin through Nu Skin Conductive Gel. The patient is the intended operator of the Nu Skin RenuSpa iO device. All of Nu Skin RenuSpa iO functions are safe for patient use. Nu Skin RenuSpa iO device does not prevent, diagnose, or treat any medical condition. It is suitable for home use and manufactured by Nu Skin Enterprises. For external use only. 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 301_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 39/5/23 15:569/5/23 15:56 4 CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, AND ADVERSE REACTIONS Please read the following before using your Nu Skin ® RenuSpa iO.™ CONTRAINDICATIONS FOR USE The Nu Ski RenuSpa iO with Nu Skin ® Conductive Gel is contraindicated for use on the: • Head and face • Throat, Neck, or Décolleté • Do not use the device over your neck or throat. It could cause muscle spasms. Those spasms may result in difficulty breathing, or adverse effects on heart rhythm or blood pressure. • Chest, thorax, or upper back • Do not use the device across your chest or thorax. Electrical current around the chest may cause heart rhythm disturbances increasing the risk of cardiac fibrillation. This could be lethal. • Groin • Areas that can ’ t sense touch It is also not intended for: • Children • Persons with reduced: • Physical • Sensory • Mental capabilities Do not use it if you: Have a/n: • Metal implant • Pacemaker • Implanted defibrillator • Other implanted electronic devices • Suspected or diagnosed epilepsy • Seizure disorder • Open sore or wound • Problematic or sensitive skin Or are: • Allergic to gels or metal • Sensitive to contact with metals 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 401_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 49/5/23 15:569/5/23 15:56 5 • Pregnant or trying to get pregnant • Prone to pityriasis rosea • Epileptic WARNINGS WARNING Nu Skin ® RenuSpa iO™ stimulates your body ’ s skin with microcurrents. Be careful when applying microcurrents to your skin. The device provides electrical stimulation when it is on and in contact with your skin. • Check with your doctor before use if you: • Have sensitive skin • Wear body piercings • Are chronically ill • Speak with your doctor before using the device. It may cause lethal heart rhythm disturbances in susceptible individuals. • Do not use it to apply electrical stimulation over painful areas. If you have painful areas, talk to your doctor before using RenuSpa iO. • Do not use it on areas of skin that lack normal sensation. It may result in irritation. • Only use the device on normal, clean, healthy skin. • Do not use the device to apply electrical stimulation on: • Open wounds • Rashes • Swollen, red, infected, or inflamed areas • Skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins) • Do not use the device over or near cancerous lesions or diseased tissues. • Do not use the device near electronic monitoring equipment, including: • Cardiac monitors • ICDs • Pacemakers • ECG alarms • Do not use the device to apply electrical stimulation to the skin without Nu Skin ® Conductive Gel as it may irritate your skin. • Apply an ample amount of Nu Skin Conductive Gel to the skin. As needed, apply more Conductive Gel to all contact points. • Nu Skin Conductive Gel should not be reused. • Do not operate while bathing or showering. • To reduce the risk of shock, irritation, fire, or injury, do not fully immerse your Nu Skin RenuSpa iO. • Do not place or store the device or charger where it may fall or be pulled into a bathtub, shower, sink, or toilet. • To prevent the possibility of injury, never expose the device to heat. Do not store near a heat source, such as a radiator, fire, or heat vent. Do not leave in a hot vehicle. • Do not leave the device in the extreme cold or heat (e.g., below freezing, in a hot vehicle). 01_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 501_002589_94515584-3_NS-RenuSpa-iO-MedDevice-UserManual.indd 59/5/23 15:569/5/23 15:56 6 • Use in a home setting out of direct sunlight. • Do not use the device while sleeping. • Do not use it with other devices at the same time. • Do not use the device to apply electrical stimulation while: • Driving • Using machinery • Engaging in any activity that can put you at risk of injury • Do no…

Text truncated - open the document above for the full version.

Attestation Statements

Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 4, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AZ3A-BS2RCCA NSE Products, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, NSE Products, Inc. (“the agent”) is our designated U.S. agent for service of process for the above referenced FCC ID. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-r elated proceeding involving the equipment. The agent accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Sincerely, Designated U.S. Agent Information: Name: NSE Products, Inc. FRN: 0030966055 Contact Person: Spencer Jarvis Address: 75 West Center Street Provo Utah United States 84601 Tel.: 8013451000 Email: [email protected] U.S. Agent Signature: Applicant: FRN: 0030966055 Company Name: NSE Products, Inc. Grantee Code: 2AZ3A Contact Person: Spencer Jarvis Address: 75 West Center Street Provo Utah United States 84601 Tel.: 8013451000 Email: [email protected] Applicant Signature:

Cover Letter(s)

This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Cover Letter-Wireless Charger Approval Date: August 22, 2023 Regarding FCC ID: 2AZ3A-BS2RCCA To who it may concern: The device with Wireless Power Transfer function is designed with features and specifications below, which meet requirements in KDB 680106 D01 section 5. b). KDB 680106 D01 Section 5.2 Requirements: Product Technical Specification: Result: a) Power transfer frequency is less that 1 MHz 116 kHz Complied b) Output power from each primary coil is less than or equal to 15 Watts The output power is less than 15W Complied c) The system may consist of more than one source primary coils, charging one or more clients. If more than one primary coil is present, the coil pairs may be powered on at the same time. Only one single primary coil. Complied d) Client device is placed in in contact with the transmitter The client device is placed directly in contact with the transmitter Complied e) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Mobile exposure conditions only. Complied f) The aggregate H-field strengths anywhere at or beyond 15 cm surrounding the device, and 20 cm away from the surface from all coils that by design can simultaneously transmit, and while those coils are simultaneously energized, are demonstrated to be less than 50% of the applicable MPE limit. Only one single primary coil. Please refer to the RF exposure report. Complied Name (Printed): Jim Chang Title: Manager On behalf of: SGS Taiwan Ltd.

Cover Letter(s)

Date: August 29, 2023 Family Declaration Dear Examiner Regarding FCC ID: 2AZ3A‐BS2RCCA IC: 26225‐BS2RCCA The Base Type designation: BS2RCC And The Additional Type designation(s): BS2RCA The only difference between the above base Type designation and the additional Type designation(s) as follows: Type designationDifference BS2RCC With USB Type C BS2RCA With USB Type A Should you have any questions, please contact us. Sincerely, Name (Printed): Jim Chang Title: Manager On behalf of: SGS Taiwan Ltd.

Cover Letter(s)

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Date: September 11, 2023 Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: 2AZ3A‐BS2RCCA Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☐ Short Term Internal Photos ☐ Permanent * ☐ Short Term Test Setup Photos ------------------ ☐ Short Term User’s Manual ☐ Permanent * ☐ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request.

External Photos

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 1 of 8 External_Type-A Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 2 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 3 of 8 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS …

Text truncated - open the document above for the full version.

ID Label/Location Info

Label & Location Label: Bottom Side of the EUT:

ID Label/Location Info

FPO Li-ion 00 NU SKIN® Model: BS2RCA 90027882 INPUT: USB 5V 500mA SN XXXXXXXXXXX LOT XXXX Patent Pending Made in China ©202 3 94517301/2 IP24 Transport/Storage -2 5° C 60° C Operating 5° C 30° C Exxxxx FCC ID: 2AZ3A-BS2RCCA Nu Skin Enterprises 75 W. Center St. Provo, UT 84601 Black PMS Color PMS 214 4 PMS Color PMS Color PMS Color PMS Color PMS Color File Name: 002910_94517301-2_NuSkin-RenuSpa-iO-chrgr-sytem-label Formula: Dimensions and Colors X.X” length36mm width18mm height 002910_94517301-2_NuSkin-RenuSpa-iO-chrgr-sytem-label.indd 1002910_94517301-2_NuSkin-RenuSpa-iO-chrgr-sytem-label.indd 18/4/23 4:04 PM8/4/23 4:04 PM

Internal Photos

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 1 of 5 Internal Antenna Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 2 of 5 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TERF2305001252ER-P Page: 3 of 5 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS…

Text truncated - open the document above for the full version.

RF Exposure Info

Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.sgs.com.tw Member of SGS Group Report No.: TESA2305000294E5 Page: 1 of 15 RF EXPOSURE REPORT Applicant: NSE Products, Inc. 75 West Center Street Provo Utah United States 84601 FCC Product Name: RenuSpa iO FCC Brand Name: Nu Skin FCC Model No.: BS2RCA, BS2RCC FCC Model Difference: BS2RCA with USB-A charger BS2RCC with USB-C charger IC Product Name: WellSpa iO IC Brand Name: Nu Skin IC Model No.: BS2RCA, BS2RCC IC Model Difference: BS2RCA with USB-A charger BS2RCC with USB-C charger Report Number: TESA2305000294E5 FCC ID 2AZ3A-BS2RCCA IC: 26225-BS2RCCA Issue Date: Sep. 23, 2023 Date of Test: Jun. 08, 2023 ~ Jun. 29, 2023 Date of EUT Received: Jun. 08, 2023 Approved By John Yeh We hereby certify that: The above equipment was verified by SGS Taiwan Ltd. The evaluation in this report is in compliance with FCC KDB 680106 D01v03r01 and RSS 102 Issue 5. The results of this report relate only to the sample identified in this report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Spencer Raymond Jarvis(Director Regulatory Affairs)
[email protected]8013451000Fax: 8013453050

Technical Contact

SGS Taiwan Ltd.Jim Chang
[email protected]886 2 2299 3279

No. 134, Wu Kung Rd., New Taipei Industrial Park · New Taipei City · Taiwan

Non-Technical Contact

SGS Taiwan Ltd.Jim Chang
[email protected]886 2 2299 3279

Test Firm

SGS Taiwan Ltd. Central RF LabRyan WANG
[email protected]886222993279

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.116 MHz - 0.116 MHz-
Confidentiality
Long Term
Grant Notes
The antenna used for this transmitter must be installed to provided separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from NSE Products, Inc.

2AZ3A-PD1R

Prysm iO

Sep 05, 2025

Equipment Class

DTS - Digital Transmission System
Facial cleansing and treatment skin care device - FCC ID 2AZ3A-LS2F - NSE Products, Inc.
2AZ3A-LS2F

Facial cleansing and treatment skin care device

Oct 20, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Facial cleansing and treatment skin care device - FCC ID 2AZ3A-LS2R - NSE Products, Inc.
2AZ3A-LS2R

Facial cleansing and treatment skin care device

Oct 20, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter