Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER’S MANUAL ® ® CMYK PMS Color PMS CG10 PMS Color PMS 631 PMS Color PMS Color PMS Color File Name: 002272_94514492-1_ageLOC-LumiSpa-iO-UserManual Formula: Formula Dimensions and Colors 3.1875” width0” depth4.75” height 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 1002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 15/31/22 4:01 PM5/31/22 4:01 PM TABLE OF CONTENTS System Components 1 Safety Instructions, Warnings, and Precautions 2 Charging Your ageLOC® LumiSpa ® iO 4 Connecting Your ageLOC LumiSpa iO to the App 5 Treatment Heads and Treatment Cleansers 6 Attaching and Removing Your Treatment Head 7 Using Your ageLOC LumiSpa iO 8 Cleaning and Care After Every Use 9 Troubleshooting 10 Device Disposal 10 Replacement and Warranty Information 10 Patents 10 Device Quality and Usage Information 11 Technical and Regulatory Information 11 SYSTEM COMPONENTS Power Button Front Indicator Lights NOTE: Illustrations do not reflect actual size. 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 2002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 25/31/22 4:01 PM5/31/22 4:01 PM 1 SYSTEM COMPONENTS ageLOC® LumiSpa ® iO Power Button Back Indicator Lights Treatment Head Magnetic Charger Front Indicator Lights NOTE: Illustrations do not reflect actual size. 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 1002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 15/31/22 4:01 PM5/31/22 4:01 PM 2 SAFETY INSTRUCTIONS, WARNINGS, AND PRECAUTIONS ageLOC® LumiSpa ® iO was designed for use by competent adults. Given proper supervision or instruction concerning its use (i.e., in a safe way and understanding the hazards involved), ageLOC LumiSpa iO can be used by children aged 8 years old and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge. ageLOC LumiSpa iO is not a toy and children should not play with it. Cleaning and user maintenance should not be performed by children. Periodically inspect for damage; never operate the device if it has been damaged. ageLOC LumiSpa iO contains a lithium-ion battery. To prevent potential damage or injury, never expose the device to heat. Do not store near a heat source, such as a radiator, fire, or heat vent. Do not leave in a hot vehicle. Check with your carrier before shipping or flying with this device. Rechargeable batteries, like those in the ageLOC LumiSpa iO, need to carry a minimal charge in order to function properly. We recommend charging your device whenever a low battery is indicated. Do not attempt to replace battery. This appliance contains batteries that are non-replaceable. Note that ageLOC LumiSpa iO is charged using inductive charging. Always use the provided charger. Do not attempt to charge using any other inductive charger. If damaged, contact Nu Skin Support Services. Do not leave your ageLOC LumiSpa iO in a cold environment for prolonged periods of time. Always place your device on a heat-resistant, stable, flat surface when charging. Use ageLOC LumiSpa iO only as directed. 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 2002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 25/31/22 4:01 PM5/31/22 4:01 PM 3 USAGE • Keep out of reach of children. • Do not use device with a damaged treatment head. • Do not expose ageLOC® LumiSpa ® iO magnetic charger to water. • Do not use power cord in a wet environment. • Do not use power cord if it is damaged. • Regularly clean handgrip. • Do not use harsh chemicals or abrasives on your ageLOC LumiSpa iO device. • Do not share treatment heads. • Only use device for recommended treatment times. • Do not use for an excessive period on one area of the skin. • Only use device as directed and do not apply to raised moles or compromised skin. TEMPERATURE The optimal temperature range for the device is between 10°C to 27°C (50°F to 80°F). It is recommended to not use or charge the device in temperatures exceeding 32°C (90°F). Very high temperatures or hot environments, such as those above 60°C/140°F, direct sunlight, within vehicle in extremely hot conditions, etc. can result in overheating and severely impact performance and product life or lead to other catastrophic condition, such as catching fire. SERVICING Do not attempt to repair your device yourself. This will void any warranty. There are no user-serviceable parts inside. Please see warranty section for service. 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 3002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 35/31/22 4:01 PM5/31/22 4:01 PM 4 CHARGING YOUR AGELOC® LUMISPA® iO • Prior to placing the ageLOC LumiSpa iO magnetic charger on your device, make sure your device is completely dry. • Place the magnetic charger on the bottom front portion of the device just below the LED display. The charger will magnetically snap into place when positioned correctly. Plug the USB cable on the magnetic charger into a USB power brick and plug into an outlet until device is fully charged. When used as recommended, the device will maintain a charge for at least a week. • While the ageLOC LumiSpa iO is charging, the front indicator lights glow starting from the bottom and moving to the top. When the device is fully charged, lights turn green and remain lit. NOTE: If the battery is low, the bottom lights will display amber after a treatment. 1 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 4002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 45/31/22 4:01 PM5/31/22 4:01 PM 5 CONNECTING YOUR AGELOC® LUMISPA® iO TO THE APP Apple and the Apple Logo are trademarks of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. • To unlock the full ageLOC LumiSpa iO experience, download the Nu Skin Vera ® app from the App Store ® or Google Play Store. 1 002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 5002272_94514492-1_ageLOC_LumiSpa_iO_UserManual.indd 55/31/22 4:01 PM5/31/22 4:01 PM 6 TREATMENT HEADS AND TREATMENT CLEANSERS ageLOC® LumiSpa ® iO offers a choice of treatment heads and a sel…
Text truncated - open the document above for the full version.
1(1) July 27, 2022 Attention: Application Examiner RE: Request for Confidentiality Applicant: NSE Products Inc. FCC ID: 2AZ3A-LS2F To Whom It May Concern: Permanent Confidentiality Request is hereby submitted by NSE Products Inc.to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: • Schematics • Detailed Block Diagrams • Detailed Operational/Functional Description We have invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading-edge technology developed by us. McKay Noll Regulatory Affairs Manager NSE Products Inc.
September 19, 2022 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement NSE Products Inc. FCC ID: 2AZ3A-LS2F To Whom It May Concern: We, NSE Products Inc. hereby authorized Intertek Testing Services to act as our Agent for the purpose of preparing application for FCC ID number 2AZ3A-LS2F under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is September 19, 2022. The Limited Agency Agreement expires on December 1, 2022 unless sooner terminated or extended by written notice to Intertek Testing Services and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, McKay Noll Regulatory Affairs Manager - Devices
LS2F - Label and Label Location Model, FCC ID, and IC ID Circled in Red
NSE Products, Inc. RF Exposure Exhibit SCOPE OF WORK EMC TESTING – AngeLOC LumiSpa iO, Model: LS2F REPORT NUMBER 104685526MPK-009a ISSUE DATE October 18, 2022 REVISED DATE N/A PAGES 8 DOCUMENT CONTROL NUMBER Non-Specific Radio Report Shell Rev. December 2017 MPK © 2017 INTERTEK Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 2 of 8 RF Exposure Exhibit (Portable devices) Report Number: 104685526MPK-009a Project Number: G104685526 Report Issue Date: October 18, 2022 Product Designation: Model Tested: AgeLOC LumiSpa iO LS2F FCC ID: 2AZ3A-LS2F IC: 26225-LS2F to 47CFR 2.1093 RSS-102 Issue 5 for NSE Products, Inc. Tested by: Client: Intertek 1365 Adams Court Menlo Park, CA 94025 USA NSE Products, Inc. 75 W Center St Provo, UT 84601 USA Report prepared by: Report reviewed by: Aaron Chang / EMC Project Engineer Minh Ly / EMC Team Lead This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accor dance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Cli ent is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. REPORT NUMBER: 104685526MPK-010 Issued: November 23, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 3 of 8 Report No. 104685526MPK-009a Equipment Under Test: AgeLOC LumiSpa iO Model(s) Tested: LS2F Applicant: NSE Products, Inc. Contact: Spencer Jarvis Address: NSE Products, Inc. 75 W Center St Provo, UT 84601 Country: USA Email: [email protected] Applicable Regulation: 47CFR 2.1093 RSS-102 Issue 5 REPORT NUMBER: 104685526MPK-010 Issued: November 23, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 4 of 8 TABLE OF CONTENTS 1.0 RF Exposure Summary ................................................................................................................... 5 2.0 RF Exposure Limits ........................................................................................................................ 5 3.0 Test Results (Portable Configuration) .......................................................................................... 6 4.0 Document History ........................................................................................................................... 8 REPORT NUMBER: 104685526MPK-010 Issued: November 23, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 5 of 8 1.0 RF Exposure Summary Test Reference FCC Reference Industry Canada Result Radio frequency Radiation Exposure Evaluation 47 CFR§2.1093 RSS- 102 Issue 5 Complies 2.0 RF Exposure Limits 2.1 FCC Limits According to FCC KDB 447498 D01 v07 Appendix B, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 3 mW. 2.2 Industry Canada Limits According to RSS-102 sec. 2.5.1, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 4 mW. REPORT NUMBER: 104685526MPK-010 Issued: November 23, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 6 of 8 3.0 Test Results (Portable Configuration) 3.1 Classification For purposes of this section, a portable device is defined as a tr ansmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Per the applicant, NSE Products, Inc. is not intended to be worn on the body. 3.2 EIRP calculations The AgeLOC LumiSpa iO consists of Bluetooth Low Energy and RFID radios. Note: RFID radio complies Field Strength limits of 47 CFR FCC Part 15 sub part 15.225 as per test Report # 104685526MPK-008. RFID radio is exempted from SAR requirements. 3.3 Maximum RF Power Frequency Range (MHz) RF Output (dBm) Antenna Gain 1 (dBi) Note 2402-2480 -1.77 2.0 Conducted power measurements were taken from Report #104685526MPK-005. 1 As declared by the manufacturer. REPORT NUMBER: 104685526MPK-010 Issued: November 23, 2021 Non-Specific Radio Report Shell Rev. December 2017 MPK EMC Report for NSE Products, Inc. on the LS2F Page 7 of 8 3.4 RF Exposure Calculation for AgeLOC LumiSpa iO 3.4.1 RF Exposure calculation for FCC KDB 447498 D01 v07 According to FCC KDB 447498 D01 v07 Appendix B, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 3 mW. Max Peak Conducted Power measured = -1.77 dBm or 0.67 mW No duty cycle was considered. Therefore, the Maximum EIRP calculated is -1.77 dBm (RF Conducted Power) + 2.0 dBi (Antenna Gain) = 0.23 dBm or 1.05 mW. Results: SAR evaluation is not required since the higher of the maximum conducted or equivalent isotopically radiated power (EIRP) source-based, time averaged output power is below the exemption limit. Note: Antenna gains below 0 are considered as 0dBi. 3.4.2 RF Exposure calculation for RSS-102 Issue 5 According to RSS-102 sec. 2.5.1, at frequency 2450 MHz and separation distance of ≤ 5 mm SAR Exemption limit is ≤ 4 mW. Max Peak Conducted Power measured = -1.77 dBm or 0.67 mW No duty cycle was considered. Therefore, the Maximum EIRP calculated is 0.8 dBm (RF Conducted Power) + 2.0 dBi (Antenna Gain) = 0.23 dBm or 1.05 mW. Results: SAR evaluation is not required since the higher of the maxim…
Text truncated - open the document above for the full version.
EMC Report for NSE Products, Inc. on the LS2F File: 104685526MPK-008 Page 1 of 23 TEST REPORT Report Number: 104685526MPK-008 Project Number: G104685526 November 19, 2021 Testing performed on the AgeLOC LumiSpa iO Model Number: LS2F FCC ID: 2AZ3A-LS2F IC: 26225-LS2F to FCC Part 15 Subpart C (15.225) Industry Canada RSS-210 Issue 10 for NSE Products, Inc. Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA NSE Products, Inc. 75 W Center St Provo, UT 84601 USA Prepared by: Date: November 19, 2021 Kenneth Roque Reviewed by: Date: November 19, 2021 Krishna Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report for NSE Products, Inc. on the LS2F File: 104685526MPK-008 Page 2 of 23 Report No. 104685526MPK-008 Equipment Under Test: AgeLOC LumiSpa iO Model Number: LS2F Applicant: NSE Products, Inc. Contact: Alan Miller Address: NSE Products, Inc. 75 W Center St Provo, UT 84601 Country: USA Tel. Number: (801) 310-4897 Email: [email protected] Applicable Regulation: FCC Part 15 Subpart C (15.225) Industry Canada RSS-210 Issue 10 Dat e of Test: September 9, 2021 – October 29, 2021 We attest to the accuracy of this report: Kenneth Roque EMC Project Engineer Krishna K Vemuri EMC Manager EMC Report for NSE Products, Inc. on the LS2F File: 104685526MPK-008 Page 3 of 23 TABLE OF CONTENTS 1.0 Summary of Tests ....................................................................................................................... 4 2.0 General Description ................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 6 2.3 Test Methodology ............................................................................................................... 6 2.4 Test Facility ......................................................................................................................... 6 2.5 Measurement Uncertainty ................................................................................................. 6 3.0 System Test Configuration ......................................................................................................... 7 3.1 Support Equipment ............................................................................................................. 7 3.2 Block Diagram of Test Setup ............................................................................................... 7 3.3 Justification ......................................................................................................................... 9 3.4 Software Exercise Program ................................................................................................. 9 3.5 Mode of Operation during test ........................................................................................... 9 3.6 Modifications required for Compliance .............................................................................. 9 3.7 Additions, deviations and exclusions from standards ........................................................ 9 4.0 Measurement Results .............................................................................................................. 10 4.1 Field Strength of Fundamental and Radiated Emissions Outside the band ..................... 10 4.2 Frequency Tolerance ........................................................................................................ 17 4.3 Occupied Bandwidth ......................................................................................................... 19 4.4 AC Line Conducted Emission ............................................................................................. 21 5.0 List of test equipment .............................................................................................................. 22 6.0 Document History .................................................................................................................... 23 EMC Report for NSE Products, Inc. on the LS2F File: 104685526MPK-008 Page 4 of 23 1.0 Summary of Tests TEST REFERENCE FCC 15.225 REFERENCE RSS-210 RESULTS Field Strength of Fundamental 15.225(a) B.6 Complies Radiated Emissions Outside the band 15.225(b), 15.225(c), 15.225(d), 15.209 B.6 Complies Frequency Tolerance of the Carrier 15.225(e) B.6 Complies Line Conducted Emissions 15.207 RSS-GEN Not applicable. Radio does not function while charging. Occupied Bandwidth 15.215 RSS-GEN Complies Antenna requirement 15.203 RSS-GEN Complies 1 1 The EUT utilizes an internal Antenna. EUT receive date: September 9, 2021 EUT receive condition: The pre-production version of the EUT was received in good condition with no apparent damage. As declared by the Applicant, it is identical to the p…
Text truncated - open the document above for the full version.
37.00 ±0.20 14.55 27.37 4X5.60 16.40 2x2.00 2x0.80 50.00 2.00 4.60 F F G 2 0.300(include 3M and magnetic separator) SECTION F-F SCALE 2 : 1 0.08 FPC thickness magnetic separator on this side 3M9019 adhesive on this side 2.00 0.90 0.60 4- 0.40 throgh hole DETAIL G SCALE 4 : 1 4 PADS 2 2 2 REVISIONS REV.DESCRIPTION DATEENGINEERAPPROVER 01 INITIAL RELEASE2021-01-08nscbzhanPHILIP LI 02 modify 2 slots,add 2 pads on another side,add 4 through holes 2021-06-21FORESTPHILIP LI N/A LumiSPA 2.0 IoT RFID ANTENNA FPCNuSkin NSUH-LP20IoT-10203-100 0.26 g 252.95 mm3 Mass Volume PHILIP LI 2021-01-08 APPROVED BY 11 OFSHEET: 2:1 SCALE: 2D NAME 3D NAME NSUH-LP20IOT-10203-100 FPC REV.02 PART NO. A3SIZE: MATERIAL TITLE CHECKED BYDRAWN BY N/A PROJECT CUST REV. CUSTOMER PART NO.CUSTOMER DESCRIPTIONCUSTOMER RFID ANTENNA FPC 2021-01-08 nscbzhan UNIT: mm 432 B 1 A GENERAL NOTES: Tolerance unless stated 0 - 10mm ± 0.10 mm 10 - 30mm ± 0.15 mm 30-100mm ± 0.20 mm >100mm ± 0.25 mm Angle ± 1° This drawing, and its inherent design concepts, are the property of Nu Skin Enterprises, Inc. subject to the provisions of client contracts, and as such may not be copied, reproduced or given to third parties without the written consent of Nu Skin Enterprises, Inc. NSUH-LP20IoT-10203-100 Notes: 1. MATERIAL REQUIREMENTS: 1.1.MATERIAL: FPC 1.2. COLOR: NATURAL 1.3. BASE MATERIAL MUST BE ROHS COMPLIANT REQUIREMENT, DIRECTIVE 2011/65/EU &ROHS 3 DIRECTIVE(EU) 2015/863 AND CHINA ROHS. 2. REMOVE ALL BURRS AND SHARP EDGES. 3. DIMENSIONS CRITICAL TO QUALITY ARE MARKED WITH A , CPK>=1.33 4. FINISHED PARTS TO BE FREE FROM CONTAMINANTS SUCH AS OIL, GREASE OR DIRT. 5. FOR ALL UNSPECIFIED DETAILS REFER TO 3D DATA. 6. DIMENSIONING AND TOLERANCING TO ASME Y14.5:2009 7. TREAT ALL 3D DATA AS BASIC TO MID-LIMIT 8. PARTS TO BE APPROVED FOR FIT AND FUNCTION PRIOR TO PRODUCING PRODUCTION QUANTITIES. 9. GENERAL TOLERANCE FOR ALL FEATURES WITHOUT INDICATORS 0.5A BC
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Prysm iO
Equipment Class
DTS - Digital Transmission System
RenuSpa iO
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Facial cleansing and treatment skin care device
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter