FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CLMBR, INC./
  3. 2AZ9G-CLMBR16992

2AZ9G-CLMBR16992Clmbr Connected

CLMBR, INC.
Clmbr Connected - FCC ID 2AZ9G-CLMBR16992 - CLMBR, INC.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 23, 2023
Application Purpose
Original Equipment
Date of Application
Apr 23, 2023
Equipment Note
Clmbr Connected
Frequency Range
2402.00000000 - 2480.00000000
Company
CLMBR, INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CLMBR-16992 Clmbr Connected User Manual Version 3.0 2022/08 1 About This Document No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, including, but not limited to, electronic, magnetic, optical, chemical, manual, or otherwise without prior written permission of CLMBR, Inc. The information in this document is subject to change without notice. CLMBR makes no representations or warranties with respect to the contents herein, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. CLMBR reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of CLMBR to notify any person of such revisions or changes. Windows is a registered trademark of Microsoft, Inc. Other brand or product names are trademarks of their respective holders. 2 | Compliance Information For FCC (USA) Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC& IC Radiation Exposure Statement: This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Déclaration d’IC sur l’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada pour des environnements non contrôlés. Cet équipement doit être installé et utilisé à une distance minimum de 20 cm entre l’antenne et votre corps. 3 | Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur. For IC (Canada) CAN ICES-003(B)/NMB-003(B) For CE (EU) The device complies with the radio equipment Directive 2014/53/EU 4 | Renseignements relatifs à la conformité Pour la FCC (États-Unis). Attention : L'utilisateur est averti que les changements ou modifications non expressément approuvés par la partie responsable de la conformité pourraient annuler l'autorité de l'utilisateur à utiliser l'équipement. Cet appareil est conforme à la partie 15 des règles de la FCC et aux normes RSS exemptes de licence d'Industrie Canada. Le fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d'interférences nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences susceptibles de provoquer un fonctionnement indésirable. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. REMARQUE : cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l'énergie de fréquence radio et, s'il n'est pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux communications radio. Cependant, il n'y a aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement cause des interférences nuisibles à la réception radio ou télévision, ce qui peut être déterminé en éteignant et en rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger l'interférence par une ou plusieurs des mesures suivantes : -- Réorientez ou déplacez l'antenne de réception. -- Augmenter la distance entre l'équipement et le récepteur. -- Brancher l'équipement sur une pr…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.0 Rev. Feb 6, 2023 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name CLMBR, INC. Address 3033 E 1st Avenue Suite 501 Denver, Colorado, 80206, United States Grantee Code 2AZ9G FCC ID 2AZ9G-CLMBR16992 Authorized Contact Name Kenny Rosenzweig Contact Email [email protected] Contact Phone (914)610-0486 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List CLMBR, INC. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. CLMBR, INC. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. Applicant Signature: Date:3/17/2023 Print Name: Kenny Rosenzweig Title: - *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

UNITED STATES DESIGNATED AGENT LETTER Date: 3/10/2023 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: CLMBR, INC. Company Name: CLMBR, INC. Grantee Code: 2AZ9G FRN: 0031016678 Contact Name: Kenny Rosenzweig Contact Name: Kenny Rosenzweig Address: 3033 E 1st Avenue Suite 501 Address: 3033 E 1st Avenue Suite 501 City/Province/Zip: Denver/Colorado/80206 City/Province/Zip: Denver/Colorado/80206 Telephone: (914)610-0486 Telephone: (914)610-0486 Fax: 303-941-8807 Fax: 303-941-8807 Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: 2AZ9G- CLMBR16992 ATTN: Director of Certification: We, CLMBR, INC. and CLMBR, INC. understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, CLMBR, INC. and CLMBR, INC. acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Applicant CLMBR, INC. U.S. designated agent CLMBR, INC. Name (Printed): Kenny Rosenzweig Name (Printed): Kenny Rosenzweig Title:- Title:- Signature: Signature:

Cover Letter(s)

CLMBR, INC. Authority letter FCC Date: 3/17/2023 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2AZ9G-CLMBR16992 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Kobe Jian in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with CLMBR, INC.. This authorization is valid until further written notice from the applicant. Name (Printed): Kenny Rosenzweig Title: - Signature: On behalf of Company: CLMBR, INC.

Cover Letter(s)

CLMBR, INC. Confidential letter FCC To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: CLMBR, INC. 3033 E 1st Avenue Suite 501 Denver, Colorado, 80206, United States Regarding: Confidentiality Request regarding application for FCC ID: 2AZ9G-CLMBR16992 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Name (Printed): Kenny Rosenzweig Title: - Signature: On behalf of Company: CLMBR, INC.

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 1 of 4 Appendix External Photos for GZCR2211001443AT Test Model No.: CLMBR-16992 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 2 of 4 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-02 Rev 1.1 Page: 4 of 4

ID Label/Location Info

Label and location:

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 1 of 10 Appendix Internal Photos for GZCR2211001443AT Test Model No.: CLMBR-16992 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 2 of 10 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 3 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 4 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 5 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 6 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 7 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 8 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 9 of 10 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-03 Rev 1.1 Page: 10 of 10

Operational Description

EVERY CONNECTION COUNTS TES 2’nd Simulate Report WiFiantenna of FCD-215 CBR RevA 2022.07.25 / Raymond Wang Building 2, Lane 270, Section 3, Beishen Road, Shenkeng District, Xinbei City, Taiwan. © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 2 TEST DETAILS AND SPEC TE Engineering Location, EngineerTaiwan, Raymond Wang Customer Equipment NameTES Bands / FrequenciesBand: WiFi F [MHz]: 2400-2500, 5150-5875 Requirements or TargetsTarget: Test EquipmentCST Test Report TypePreliminary Antennas2344654-0/-9 TaskSimulate for currently placement Ant enna Gain (Peak) < 1dBi EVERY CONNECTION COUNTS FCD-215 CBR Simulate the antenna performance for currently placement © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 4 Picture for Antenna Position Antenna Position Antenna © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 5 Picture for Antenna Position Antenna Position 6.6 mm 7.5 mm 45 mm 7.5 mm © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 6 Return Loss © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 8 2D Radiation for 2450MHz Phi 0 Phi 90 Theta 90 © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 9 2D Radiation for 5470MHz Phi 0 Phi 90 Theta 90 © 2020 TE Connectivity.Confidential & Proprietary. Do not reproduce or distribute externally including non-authorized representatives and distributors.Create a sustainable future by limiting print copies, and recycling paper. 10 TEST RESULT / CONCLUSION For the currently placement, the average gain of simulation result is better than -1dBi by CST. The performance of antenna without the antenna cable. The simulation results shownthat the below antenna propose keep out area can provide good antenna performance. 6.6 mm 7.5 mm 45 mm 7.5 mm WHEN TECHNOLOGY CONNECTS, SO DOES HUMANITY. EVERY CONNECTION COUNTS

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR221100144303 Page: 1 of 87 FCC ID: 2AZ9G-CLMBR16992 Ricky Liu Manager TEST REPORT Application No.: GZCR2211001443AT Applicant: CLMBR, Inc Address of Applicant: 3033 E 1st Avenue Suite 501 Denver, Colorado, 80206, United States Manufacturer: CLMBR, Inc Address of Manufacturer: 3033 E 1st Avenue Suite 501 Denver, Colorado, 80206, United States Factory: TES Touch Embedded Solutions (Xiamen) Co., Ltd. Address of Factory: No. 60, Xinglin South Rd., Jimei District, Xiamen, Fujian 361022, China Equipment Under Test (EUT): EUT Name: Clmbr Connected Model No.: CLMBR-16992 Trade Mark: Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2022-08-23 Date of Test: 2022-08-30 to 2022-12-02 Date of Issue: 2023-04-14 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR221100144303 Page: 2 of 87 Revision Record Version Report No. Date Remark 01 GZCR221100144303 2023-04-14 Original Authorized for issue by: Jim Li/Project Engineer Vico Cui/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR221100144303 Page: 3 of 87 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence N/A 47 CFR Part 15, Subpart C 15.247(a)(1),(g),(h) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 7.8.5 47 CFR Part 15, Subpart C 15.247(b)(1) Pass 20dB Bandwidth ANSI C63.10 (2013) Section 7.8.7 47 CFR Part 15, Subpart C 15.247(a)(1) Pass Carrier Frequencies Separation ANSI C63.10 (2013) Section 7.8.2 47 CFR Part 15, Subpart C 15.247a(1) Pass Hopping Channel Number ANSI C63.10 (2013) Section 7.8.3 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Dwell Time ANSI C63.10 (2013) Section 7.8.4 47 CFR Part 15, Subpart C 15.247a(1)(iii) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 7.8.6 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 7.8.8 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Note: E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-01 Rev 1.1 Report No.: GZCR221100144303 Page: 4 of 87 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 6 4.3 Measurement Uncertainty ............................................................................................................ 7 4.4 Test Location ............................................................................................................................... 7 4.5 Test Facility .................................................................................................................................. 8 4.6 Deviation from Standards ............................................................................................................. 8 4.7 Abnormalities from Standard Conditions ....................................................................................... 8 5 Equipment List ................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ..........................................................................................13 6.1 Antenna Requirement .................................................................................................................13 6.1.1 Test Requirement: ..................................................................................................................13 6.1.2 Conclusion ..............................................................................................................................13 6.2 Other requirements Frequency Hopping Spread Spectrum System Hopping Sequence ...............14 6.2.1 Test Requirement: ..................................................................................................................14 6.2.2 Conclusion ..............................................................................................................................14 7 R…

Text truncated - open the document above for the full version.

Test Setup Photos

SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 1 of 3 Appendix Test Setup Photo for GZCR221100144302 to GZCR221100144305 Test Model No.: CLMBR-16992 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 2 of 3 Test Setup Photo Conducted Emissions at AC Power Line (150kHz-30MHz) SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-ARF-04 Rev 1.1 Page: 3 of 3 Radiated Spurious Emissions & Radiated Emissions which fall in the restricted bands Radiated Emissions (Below 1GHz)

Contact Information

Applicant

Kenny Rosenzweig
[email protected](914)610-0486Fax: 303-941-8807

Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]+862082155314

No.198 Kezhu Road, Science City Economic & · Guangzhou, Guangdong · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., LtdKobe Jian
[email protected]+862082155314

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd.Bonnie Liao
[email protected]020-8215-5379

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz500.00 µW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures.

Other Applications from CLMBR, INC.

Clmbr Connected - FCC ID 2AZ9G-CLMBR17002 - CLMBR, INC.
2AZ9G-CLMBR17002

Clmbr Connected

Apr 02, 2023

Equipment Class

DTS - Digital Transmission System
Tablet PC - FCC ID 2AZ9G-CONNECTED - CLMBR, INC.
2AZ9G-CONNECTED

Tablet PC

Jul 07, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Tablet PC - FCC ID 2AZ9G-PURE - CLMBR, INC.
2AZ9G-PURE

Tablet PC

Jul 07, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX