FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ningbo Deyi Smart Home Co., Ltd/
  3. 2AZ9W-WR09-003

2AZ9W-WR09-003Curtain remote

Ningbo Deyi Smart Home Co., Ltd
Curtain remote - FCC ID 2AZ9W-WR09-003 - Ningbo Deyi Smart Home Co., Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 13, 2026
Application Purpose
Original Equipment
Equipment Note
Curtain remote
Frequency Range
433.92500000 - 433.92500000
Company
Ningbo Deyi Smart Home Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

-3--1- Technical Specifications · Voltage: 3.7 V · Capacity: 200 mAh · Charging Power: 5 V 0.05 A (0.25 W) · Frequency: 433.925 MHz · Ambient Operating Temperature: −5°C to 50°C · Transmission Range: Outdoor: up to 220 feet Indoor (through two walls): up to 115 feet Function Description The WR09-15CH is a 15-channel transmitter. The number displayed on the screen indicates the currently selected control channel. Press CH− (decrease) or CH+ (increase) to change the channel. When the selected channel number appears on the display, the channel is active and ready for control. When “0” is displayed on the screen, all channels are active, indicating Group Control Mode. Tips: Do not expose the remote to moisture or impact, as this may affect its service life. If the transmission range is significantly reduced or responsiveness decreases during use, please recharge the remote promptly. Warnings: The remote is not user-serviceable. Do not disassemble it, as this may cause damage or pose a risk of explosion. * If the remote malfunctions, press Reset with the included pin. Release. The screen lights up, then shows channel '1' after 2 seconds to confirm the reset. Do not dispose of electrical products with household waste. Please recycle damaged electrical products properly. INS-101-C124 -2- Button Functions Accessories Pairing Steps WR09-15CH ① Press the CH− or CH+ button to select the channel(1–15) to pair. Select Channel ② Press and hold the programming button on the motor head for about 2 seconds until the motor jogs once. ③ Within 10 seconds, press and hold the STOP button for 2 seconds. The motor will jog twice, indicating that pairing is successful. 2 secs Hiding Remote Channels In the setting mode, pressing the UP or DOWN button will quickly exit. To change the active channel, the remote must be reset to select a new channel. A-01 January 2026 UP FRONT BOTTOM STOP DOWN 50% P( + ) CHANNEL UP CHANNEL DOWN ① Press and hold CH+ and CH−. The screen will display “CH”, then “15” . ② Press CH+ or CH− to select the desired channel (Channel 1 to Channel 15). ③ After selecting the channel, press and hold STOP. When the screen displays oo, the setting is successfully saved. Reset button Magnetic HolderEjector Pin Charging port — --- * Channel 0 is for Group Control Mode, which controls all chan- nels simultaneously but cannot be paired individually. -4--6--5- Low Battery Notifications Metal Bracket Installation When the battery is low, the remote displays “L” for about 3 seconds on wake-up, indicating that it needs to be recharged. Normal operation is unaffected during the “L” display, which clears automatically after 3 seconds. Combination Button Lock/Unlock Switch to Combination Button Lock state Switch to Combination Button Unlock state The remote is unlocked by default and can be switched between Lock and Unlock modes. When Locked, combination buttons are disabled, no display appears, and no codes are transmitted. When unlocked, the combination buttons display an icon indicator. Locking only affects combination buttons and does not impact the operation of other buttons. Note: The SETTING (P) button is located on the top left of the remote. Press and hold STOP(>15 s) Press and hold SETTING (P) (>1 s) Press and hold SETTING (P) (>1 s) Charging Indicator When the charger is connected, the remote will automatically wake up and display the channel number. The low battery alert will no longer appear. During charging, the UP & DOWN icons on the display screen will flash, and the remote will not enter low-power mode. When the battery is fully charged, the UP & DOWN icons will remain steadily lit. Pressing any button during charging temporarily returns the remote to the normal display. If no operation occurs for 10 seconds, it will revert to the charging display. If the charger is connected when the battery is already full, the UP & DOWN icons will flash for approximately 1 minute before remaining steadily lit. UP & DOWN icons stay lit when fully charged. Note: Install the bracket only on a solid, dry wall surface where the adhesive can bond securely. Do not use it on damp walls or in high-humidity environments, as poor adhesion may cause the bracket to fall off. Peel off the adhesive backing and attach the bracket to the wall with the concave side facing vertically. Align the remote with the bracket, and it will attach magnetically. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’ s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set fo…

Text truncated - open the document above for the full version.

Attestation Statements

Company: Ningbo Deyi Smart Home Co., Ltd Add: 101-102, Building 2, No.341, Wulipai , Jiaochuan Street, Zhenhai District, Ningbo city, Zhejiang Province, China Tel: +86-755-61156566 Fax: +86-755-3699 5506 E-mail: [email protected] Attestation Letter Date: 01/04/2026 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 § 2.911 (d) (5) (i) (ii) Filing FCC ID: 2AZ9W-WR09-003 Ningbo Deyi Smart Home Co., Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Ningbo Deyi Smart Home Co., Ltd (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Ningbo Deyi Smart Home Co., Ltd (“the applicant”) certifies that the equipment does not use Kaspersky's software information. Sincerely, Signature: Contact Person: Jack sun Title: manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2026-01-04 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2AZ9W-WR09-003 Ningbo Deyi Smart Home Co., Ltd (“the Applicant”) certifies that, as of the date of the filing of the application, Iconsigh is our designated U.S. agent for service of process for the above referenced FCC ID. Ningbo Deyi Smart Home Co., Ltd (“the Applicant”) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Address: 2310 Homestead Road, Suite C1, Los Altos, CA 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Ningbo Deyi Smart Home Co., Ltd Address: 101-102, Building 2, No.341, Wulipai , Jiaochuan Street, Zhenhai District, Ningbo city, Zhejiang Province, China FRN: 0031020720 Tel: +86-755-61156566 Email: [email protected] Signed by (printed name): Jack sun Signature:

Cover Letter(s)

Company: Ningbo Deyi Smart Home Co., Ltd Add: 101-102, Building 2, No.341, Wulipai , Jiaochuan Street, Zhenhai District, Ningbo city, Zhejiang Province, China Tel:+86-755-61156566 Fax:+86-755-3699 5506 E-mail: [email protected] FCC Authorization Date: 2026-01-04 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Ningbo Deyi Smart Home Co., Ltd, hereby authorizes Bay Area Compliance Laboratories Corp. (Kunshan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. (Kunshan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature: Print Name: Jack sun Title: manager QA-FR-170-B

Cover Letter(s)

Company: Ningbo Deyi Smart Home Co., Ltd Add.: 101-102, Building 2, No.341, Wulipai , Jiaochuan Street, Zhenhai District, Ningbo city, Zhejiang Province, China Tel:+86-755-61156566 Fax:+86-755 -3699 5506 E-mail: [email protected] FCC Confidential Authorization Date: 2026-01 -04 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AZ9W-WR09-003 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Ningbo Deyi Smart Home Co., Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below: Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printer Name: Jack sun Title: manager QA-FR-171-A

External Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 1 / 3 EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 2 / 3 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 3 / 3

ID Label/Location Info

18.4mm 15.4mm A4

Internal Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 1 / 3 EXHIBIT B - EUT INTERNAL PHOTOGRAPHS Antenna Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 2 / 3 Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 3 / 3

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RQDA260104001-00B Page 21 of 33 RF EXPOSURE EVALUATION Applicable Standard §1.1307(b)(3)(i) For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A). Frequency (MHz) Maximum EIRP (dBm) Maximum EIRP 1-mW Test Exemption mW 433.925 -41.74 0.000067 Compliant Note: 1. Chose the maximum power to do RF exposure evaluation analysis. 2. This device maximum E-Field level is 53.46 dBμV/m at 3m, so the EIRP power is -41.74dBm. 3. Pout EIRP (dBm) = Field Strength of Fundamental (dBμV/m)-95.2 for d=3m. Result: Compliant. RF Exposure is exemption.

Test Report

Page 1 of 33 FCC PART 15.231 TEST REPORT For Ningbo Deyi Smart Home Co., Ltd 101-102, Building 2, No.341, Wulipai, Jiaochuan Street, Zhenhai District, Ningbo city, Zhejiang Province, China FCC ID: 2AZ9W-WR09-003 Report Type: Original Report Product Name: Curtain remote Report Number: RQDA260104001-00B Report Date: 2026-02-25 Reviewed By: Jenny Yang Approved By: Kyle Xu Test Laboratory: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan, Jiangsu province, China Tel: +86-512-86175000 Fax: +86-512-88934268 www.baclcorp.com.cn Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Kunshan). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RQDA260104001-00B Page 2 of 33 TABLE OF CONTENTS REPORT REVISION HISTORY................................................................................................................................. 4 GENERAL INFORMATION ....................................................................................................................................... 5 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 TEST METHODOLOGY .................................................................................................................................................. 6 MEASUREMENT UNCERTAINTY .................................................................................................................................... 6 TEST FACILITY ............................................................................................................................................................. 6 SYSTEM TEST CONFIGURATION .......................................................................................................................... 7 JUSTIFICATION ............................................................................................................................................................. 7 EUT EXERCISE SOFTWARE .......................................................................................................................................... 7 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 7 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 7 EXTERNAL I/O CABLE .................................................................................................................................................. 7 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................. 10 TEST EQUIPMENT LIST ......................................................................................................................................... 11 FCC§15.203 - ANTENNA REQUIREMENT ............................................................................................................ 12 APPLICABLE STANDARD ............................................................................................................................................ 12 ANTENNA CONNECTED CONSTRUCTION .................................................................................................................... 12 FCC §15.207 (A) – AC POWER LINE CONDUCTED EMISSIONS .................................................................... 13 APPLICABLE STANDARD ............................................................................................................................................ 13 TEST SYSTEM SETUP .................................................................................................................................................. 13 EMI TEST RECEIVER SETUP ....................................................................................................................................... 13 TEST PROCEDURE ...................................................................................................................................................... 14 TEST RESULTS SUMMARY .......................................................................................................................................... 14 FCC §15.205, §15.209, §15.231 (B) - RADIATED EMISSIONS ............................................................................. 15 APPLICABLE STANDARD ............................................................................................................................................ 15 TEST SYSTEM SETUP .................................................................................................................................................. 16 EMI TEST RECEIVER SETUP ....................................................................................................................................... 18 TEST PROCEDURE ...................................................................................................................................................... 18 TEST RESULTS SUMMARY .......................................................................................................................................... 18 TEST DATA: …

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 1 / 3 EXHIBIT C - TEST SETUP PHOTOGRAPHS Conducted Emission - Front View Conducted Emission - Left View Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 2 / 3 Radiated Emissions (Below 30 MHz) Radiated Emissions (Below 1 GHz) Bay Area Compliance Laboratories Corp. (Kunshan) Project No.: RQDA260104001 3 / 3 Radiated Emissions (Above 1 GHz)

Contact Information

Applicant

Jack sun
[email protected]Fax: 0755-3699 5506

Technical Contact

IconsighBenjamin Kaur
[email protected]

2310 Homestead Road Suite C1 · Los Altos, California, 94024 · United States

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)John Chan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.925 MHz - 433.925 MHz0.10 µW
Confidentiality
Long Term
Grant Notes
Output power listed is measured radiated. The antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating condition for satisfying RF exposure compliance.

Other Applications from Ningbo Deyi Smart Home Co., Ltd

Curtain light sensor - FCC ID 2AZ9W-WR12-004 - Ningbo Deyi Smart Home Co., Ltd
2AZ9W-WR12-004

Curtain light sensor

Mar 16, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AZ9W-WM24C

Tubular Motor

Sep 07, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AZ9W-WR01-01CH

WR01-01CH

Apr 02, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
2AZ9W-WM35L

Low Power DC motor

Mar 31, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
WR01-15CH - FCC ID 2AZ9W-WR01-15CH - Ningbo Deyi Smart Home Co., Ltd
2AZ9W-WR01-15CH

WR01-15CH

Jun 26, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter