FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CALLTON LIGHTING CO., LTD/
  3. 2AZGPTL1056

2AZGPTL1056Regan Task Table Lamp with Wireless Charging

CALLTON LIGHTING CO., LTD
Regan Task Table Lamp with Wireless Charging - FCC ID 2AZGPTL1056 - CALLTON LIGHTING CO., LTD
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 27, 2021
Application Purpose
Original Equipment
Date of Application
May 27, 2021
Equipment Note
Regan Task Table Lamp with Wireless Charging
Frequency Range
0.11000000 - 0.20500000
Company
CALLTON LIGHTING CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

REGANTASKTABLELAMPWITHWIRELESSCHARGING-ASSEMBLYINSTRUCTIONS PARTSENCLOSED: (A) Plug (1) (B) ON/OFF rotating switch (1) (C) Lamp base (1) (D) Charging pad (1) (E) Arm joint (1) (F) LED bulb (1, included) (G) Lamp shade (1) (H) Shade joint (1) IMPORTANTSAFETYINSTRUCTIONS: For safety purposes, this lamp is equipped with a polarized plug (one blade is wider than the other). If the plug does not fit securely into your outlet, do not force it - contact a professional electrician. Use the plug with an extension cord only if it can be fully inserted into the cord's socket. Never alter the plug in any way. This lamp has been rated for up to (1) 4w max LED bulb ( included). To avoid the risk of fire, do not exceed the recommended wattage. WARNINGS: All wires are connected. When unpacking, be careful not to pull wires, as a bad connection may result. Do not connect electricity until your lamp is fully assembled. To reduce the risk of fire, electrical shock, or personal injury, always turn off and unplug lamp and allow it to cool prior to replacing lightbulb. Do not touch the bulb when lamp is turned on. Keep flammable materials away from lit bulb . THISPRODUCTISNOTATOYANDHASNOPLAYVALUE. WARNING:STRANGULATIONHAZARD Keep cord at least 3 feet away from cribs, bassinets, and toddler beds. Keep out of reach of children under 3 years of age. This device complies with Part 15 of the FCC Rules. Operationis subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply withthe limits for Class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio or television reception, which can be determined byturning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit differentfrom that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ASSEMBLY&INSTALLATION: 1. Carefully remove all parts from the box and remove all plastic coverings. 2. Carefully place the lamp base (C) on a tabletop. 3. Adjust the shade (G) with shade joint (H) and adjust the armwith arm joint (E) to get the desired lamp angle. 4. Insert the LED bulb (F) into the socket and secure tightly. 5. Insert plug (A) into proper electrical outlet and turn theON/OFF rotating switch (B) to test the lamp. 6. If a cell phone needs to be charged, place on the charging pad (D). 7. Assembly is complete. CAREINSTRUCTIONS: Do not use polishes or cleaners, as they may damage the finish. Wipe clean with a soft, dry cloth. REGANTASKTABLELAMPWITHWIRELESSCHARGING-ASSEMBLYINSTRUCTIONS This equipment complies with FCC radiation exposure limitsset forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil ettoutes les personnes. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation issubject to the following two conditions: This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : L’appareil ne doit pas produire de brouillage; L’appareil doit accepter tout brouillage radioélectriquesubi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Cover Letter(s)

CALLTON LIGHTING CO., LTD DATE : 2021-05-21 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Request for Short-Term Confidentiality Company name: Callton Lighting Co., LTD. FCC ID:2AZGPTL1056 FCC Part 15 Certification Pursuant to Sections 0.457 and 0.459 of the commission rules, and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705), we hereby request short-term confidentiality for the following items prior to marketing the device.: (1)Test Setup Photos (2)External Photos (3)Internal Photos (4)User Manual The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Sincerely,

External Photos

Appendix I External Photographs Page 2 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. View of EUT-1 View of EUT-2 Page 3 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. View of EUT-3 View of EUT-4

Internal Photos

Appendix II Internal Photographs Page 2 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-1 Internal View of EUT-2 Page 3 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-3 Internal View of EUT-4 Page 4 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-5 Internal View of EUT-6 Page 5 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-7 Internal View of EUT-8 Antenna Page 6 of 6 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-9

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE CERTIFICATION TEST REPORT For REGAN TASK TABLE LAMP WITH WIRELESS CHARGING MODEL NUMBER: TL1056 FCC ID: 2AZGPTL1056 REPORT NUMBER: 4789814649-3-2 ISSUE DATE: May 28, 2021 Prepared for CALLTON LIGHTING CO.,LTD No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi- Tech Development Zone Dongguan, 523808, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4789814649-3-2 Page 2 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 05/28/2021 Initial Issue REPORT NO.: 4789814649-3-2 Page 3 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. DESCRIPTION OF EUT ..................................................................................................... 6 5. REQUIREMENT ................................................................................................................. 7 REPORT NO.: 4789814649-3-2 Page 4 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: CALLTON LIGHTING CO.,LTD Address: No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China Manufacturer Information Company Name: CALLTON LIGHTING CO.,LTD Address: No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China EUT Information EUT Name: REGAN TASK TABLE LAMP WITH WIRELESS CHARGING Model: TL1056 Brand: / Sample Received Date: February 3, 2021 Sample Status: Normal Sample ID: 3645294 Date of Tested: February 8, 2021 ~ May 28, 2021 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47CFR§1.1307 PASS FCC 47CFR§1.1310 PASS FCC 47CFR§2.1093 PASS FCC 47CFR§2.1091 PASS Prepared By: Checked By: Denny Huang Shawn Wen Project Engineer Laboratory Leader Approved By: Stephen Guo Laboratory Manager REPORT NO.: 4789814649-3-2 Page 5 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with FCC 47CFR§1.1307(b)(1), FCC 47CFR§1.1310, FCC 47CFR§2.1093, KDB 680106 D01 RF Exposure Wireless Charging App v03r01. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Delcaration of Conformity (DoC) and Certification rules ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber D, the VCCI registration No. is G-20019 and R-20004 Shielding Room B , the VCCI registration No. is C-20012 and T-20011 Note: All tests measurement facilities use to collect the measurement data are located at Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone, Dongguan, 523808, China REPORT NO.: 4789814649-3-2 Page 6 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. DESCRIPTION OF EUT EUT Name REGAN TASK TABLE LAMP WITH WIRELESS CHARGING EUT Description REGAN TASK TABLE LAMP WITH WIRELESS CHARGING Model TL1056 Product Description Operation Frequency 110 ~ 205 kHz Rated Output Power 10 W Antenna type Coil Ratings AC 120 V, 60 Hz REPORT NO.: 4789814649-3-2 Page 7 of 9 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0019 This report shall not be reproduced except in full, without the written approval of UL Verification …

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT For REGAN TASK TABLE LAMP WITH WIRELESS CHARGING MODEL NUMBER: TL1056 FCC ID: 2AZGPTL1056 REPORT NUMBER: 4789814649-3-1 ISSUE DATE: May 27, 2021 Prepared for CALLTON LIGHTING CO.,LTD No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi- Tech Development Zone Dongguan, 523808, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4789814649-3-1 Page 2 of 24 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 05/27/2021 Initial Issue REPORT NO.: 4789814649-3-1 Page 3 of 24 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Description of Test Item Standard Results Power Line Conducted Emission Test FCC 15.207 PASS Radiated Emission Test FCC 15.209 PASS 20dB Bandwidth FCC 15.215 PASS This test report is only published to and used by the applicant, and it is not for evidence purpose in China. REPORT NO.: 4789814649-3-1 Page 4 of 24 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 6 3. FACILITIES AND ACCREDITATION ..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. TEST MODE ............................................................................................................. 8 5.3. ACCESSORY ........................................................................................................... 9 5.4. MEASURING INSTRUMENT LIST .......................................................................... 10 6. 20dB BANDWIDTH TEST ................................................................................................... 11 7. RADIATED EMISSION TEST .............................................................................................. 13 7.1. SPURIOUS EMISSIONS BELOW 30 MHz .............................................................. 17 7.2. SPURIOUS EMISSIONS 30 MHz ~ 1 GHz ............................................................. 20 8. AC POWER LINE CONDUCTED EMISSIONS .................................................................... 22 REPORT NO.: 4789814649-3-1 Page 5 of 24 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: CALLTON LIGHTING CO.,LTD Address: No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China Manufacturer Information Company Name: CALLTON LIGHTING CO.,LTD Address: No.56,168Ind.Park, JIngMei Management Zone, Dongkeng Town, Dongguan City, Guangdong Province, China EUT Information EUT Name: REGAN TASK TABLE LAMP WITH WIRELESS CHARGING Model: TL1056 Brand: / Sample Received Date: February 3, 2021 Sample Status: Normal Sample ID: 3645294 Date of Tested: February 8, 2021 ~ May 27, 2021 Prepared By: Checked By: Denny Huang Shawn Wen Project Engineer Laboratory Leader Approved By: Stephen Guo Laboratory Manager APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 FCC PART 15 SUBPART C PASS REPORT NO.: 4789814649-3-1 Page 6 of 24 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0053 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY All tests were performed in accordance with the standard FCC CFR 47 Part 2, KDB 414788 D01 Radiated Test Site v01r01, CFR 47 FCC Part 15, ANSI C63.10-2013. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Br…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix III Setup Photographs RADIATED EMISSIONS MEASUREMENT SETUP (30MHz ~ 1 GHz) POWERLINE CONDUCTED EMISSIONS MEASUREMENT SETUP RADIATED EMISSIONS MEASUREMENT SETUP (Below 30MHz) E-FILED AND H-FILED STRENGTH MEASUREMENT SETUP-1 E-FILED AND H-FILED STRENGTH MEASUREMENT SETUP-2 E-FILED AND H-FILED STRENGTH MEASUREMENT SETUP-3 E-FILED AND H-FILED STRENGTH MEASUREMENT SETUP-4 E-FILED AND H-FILED STRENGTH MEASUREMENT SETUP-5

Contact Information

Applicant

LILY LENG
[email protected]076989278612Fax: /

Technical Contact

UL Verification Services (Guangzhou) Co., Ltd., SoEcho Yin
[email protected]8676933817169

Building 10, Innovation Tech Park · Dongguan · China

Test Firm

UL-CCIC Company LimitedChris Zhong
[email protected]+86 512 68758596

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
For satisfying FCC RF exposure compliance requirements, the device must be used with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with instructions for satisfying RF exposure compliance.

Other Applications from CALLTON LIGHTING CO., LTD

TEXTURED METAL TASK TABLE LAMP WITH WIRELESS CHARGING - FCC ID 2AZGPTL1058 - CALLTON LIGHTING CO., LTD
2AZGPTL1058

TEXTURED METAL TASK TABLE LAMP WITH WIRELESS CHARGING

Jun 03, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
DECLAN TASK TABLE LAMP WITH WIRELESS CHARGING - FCC ID 2AZGPTL1057 - CALLTON LIGHTING CO., LTD
2AZGPTL1057

DECLAN TASK TABLE LAMP WITH WIRELESS CHARGING

Jun 03, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
1960s CANISTER TASK TABLE LAMP WITH WIRELESS CHARGING - FCC ID 2AZGPTL1071 - CALLTON LIGHTING CO., LTD
2AZGPTL1071

1960s CANISTER TASK TABLE LAMP WITH WIRELESS CHARGING

Jun 03, 2021

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz