Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Unified Cloud Network Management System User Guide ion4xi_WP ion4xi_WP User Guide Table of Contents 1 Introduction ...................................................................................................................................................................... 1 1.1 Product Specifications ......................................................................................................................................... 1 1.2 Federal Communication Commission Certified ......................................................................................... 2 1.2.1 FCC Caution .................................................................................................................................................... 2 1.2.2 FCC Radiation Exposure Statement ....................................................................................................... 2 1.3 Make in India .......................................................................................................................................................... 3 1.4 Safety ......................................................................................................................................................................... 3 2 ion4xi_WP (Dual Band 2x2:2 Indoor Wall Plate Access Point) ....................................................................... 4 2.1.1 Front View ....................................................................................................................................................... 4 2.1.2 Connector View............................................................................................................................................. 4 2.1.3 Back View ........................................................................................................................................................ 5 3 Initial Setup ....................................................................................................................................................................... 6 3.1 System Requirements .......................................................................................................................................... 6 3.2 Packaging Content ............................................................................................................................................... 6 3.3 Connect to the Indoor Access Point .............................................................................................................. 7 4 Installation Setup ............................................................................................................................................................ 8 5 Connect to Thick Access Point and Log In ......................................................................................................... 10 5.1 Login through GUI ............................................................................................................................................. 10 5.2 Dashboard ............................................................................................................................................................. 10 5.3 Status ...................................................................................................................................................................... 11 5.3.1 System Summary ....................................................................................................................................... 12 5.3.2 System Software ........................................................................................................................................ 13 5.3.3 System Hardware ...................................................................................................................................... 14 5.3.4 Wireless Summary .................................................................................................................................... 14 5.4 System .................................................................................................................................................................... 15 5.4.1 System Settings ......................................................................................................................................... 15 5.4.2 Set AP Password for thick AP ............................................................................................................... 16 5.4.3 Backup/ Upgrade Firmware .................................................................................................................. 17 5.4.4 Reboot ........................................................................................................................................................... 18 5.4.5 Factory Reset .............................................................................................................................................. 19 5.4.6 Syslog ............................................................................................................................................................ 19 5.5 Network ................................................................................................................................................................. 20 5.5.1 Interfaces ...................................................................................................................................................... 22 5.5.2 Wireless ......................................................................................................................................................... 24 ion4xi_WP User Guide 5.5.3 Easy Mesh Configuration ....................................................................................................................... 31 5.5.4 DHCP Server Configuration ....................................................…
Text truncated - open the document above for the full version.
2.911 (d)(5)(ii) Applicant Attestation v1.3 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: HFCL LIMITED Address: 38, Institutional Area , Sector 32, Gurgaon -122001 Product Name: IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna ( 5dBi) FCC ID: 2AZOI4XIWP Model(s): ion4xi_WP 2.911(d)(5)(ii) Applicant filing We, [HFCL LIMITED] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Sandeep Kumar Chawla Date: 22-09-2023 Title and Company name: Associate Vice President HFCL LIMITED NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
2.911 (d)(7)USA Agent v1.4 Section 2.911(d)(7) USA Agent for Service of Process Company name: HFCL LIMITED Address: Plot no. 38, Institutional Area , Sector 32, Gurgaon -122001 Product Name: IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna ( 5dBi) FCC ID: 2AZOI4XIWP Model(s): ion4xi_WP 2.911(d)(7) USA Designated Agent for Service of Process We, [HFCL LIMITED] (“the applicant”) designate [EMT Engineering , LLC...] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: EMT Engineering LLC USA Address: 1547 Plymouth St. Mountain View CA 94043 FRN Number: 0033536889 Contact Name: Radhika Gandhi Telephone No: 6506952321 Email: [email protected] Applicant Company name: HFCL LIMITED Address: Plot no. 38, Institutional Area , Sector 32, Gurgaon -122001 FRN Number: 0030825806 FCC Grantee Code: 2AZOI Contact Name: Sandeep Kumar Chawla Telephone No: +91-9811929518 Email: [email protected] 2.911 (d)(7)USA Agent v1.4 Signature: Title: President Signature: Title: Associate Vice President Date: June 13 ,2023 Date: Sep 22 ,2023 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
FCC Software Configuration Control Declaration Date: June 13, 2023 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: ion4xi_WP Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: Sandeep Kumar Chawla Date: Oct 16, 2023 Title: Associate Vice President Signature of applicant: FCC Software Configuration Control Declaration Rev1.1_ion4i_w
Agent Authorization Company: HFCL LIMITED Address: Plot no. 38, Institutional Area , Sector 32, Gurgaon -122001 Product Name: IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna ( 5dBi) Model Number(s): ion4xi_WP Product Introduction: IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna provides Wi-Fi connectivity to end users (or client devices) on 2.4 and 5 GHz unlicensed RF bands. The AP is designed especially for the Hospitality industry, the Wall Plate Access Point ensures high speeds, great network coverage & ultra-secure connectivity. Ideal for most demanding use cases and high performance-intensive applications like high definition videos & high bandwidth requirements thereby ensuring enhanced guest experience. We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 22-09-2023 Name: Sandeep Kumar Chawla Title: Associate Vice President Company: HFCL Limited
Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: Request for Confidentiality FCC ID: 2AZOI4XIWP To Whom It May Concern, Date: 16-10-2023 Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☒ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☒ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☒ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☒ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sandeep Kumar Chawla Title: Associate Vice President
EXTERNAL PHOTOS – ION4XI_WP
INTERNAL PHOTOS- ION4XI_WP INTERNAL PHOTOS- ION4XI_WP INTERNAL PHOTOS- ION4XI_WP PHOTOS WITHOUT SHIELDING CASE INTERNAL PHOTOS- ION4XI_WP INTERNAL PHOTOS- ION4XI_WP
RF EXPOSURE EVALUATION 1.PRODUCTINFORMATION Product Description IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna ( 5dBi) Model Name ion4xi_WP FCC ID 2AZOI4XIWP 2.EVALUATION METHODANDLIMIT Human exposure to RF emissions from mobile devices(47CFR§2.1091) may be evaluated based on the MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate, since exposures are assumed to occur at distances of 20 cm or more from persons. LIMITS FOR GENERAL POPULATIONIUNCONTROLLED EXPOSURE Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density(S) (mW/cm 2 ) Averaging Time IEl 2 IHl 2 or , S(Minutes) 0.3--1.34 614 1.63 (100)* 30 1.34--30 824/f 2.19/f (180/f 2 )* 30 30--300 27.5 0.073 0.2 30 300--1500 -- -- f/1500 30 1500--100,000 -- -- 1.0 30 *Note: 1.f= Frequency in MHz*Plane-wave Equivalent Power Density 2.The averaging time for General Population/Uncontrolled exposure to fixed transmitters is not applicable for mobile and portable transmitters. (operated in BT/ WIFI) See47CFR§§2.1091 and 2.1093 on source-based time-averaging requirement for mobile and portable transmitters. S=PG/4rrR 2 Where: S=power density P=power input toantenna G=power gain of the antenna in the direction of interest relative to anisotropic radiator R=distance to the center of radiation of the antenna 3.CALCULATION A minimum test separation distance 20cm is required between the antenna and radiating structures of the device and nearby persons to apply mobile device exposure limits. The distance must be at least 20cm and fully supported by the operating and installation configurations of the transmitter and its antenna(s), according to the source-based time-averaged maximum power requirements of §2.1091(d)(2). In cases where cable losses or other attenuations are applied to determine compliance, the most conservative operating configurations and exposure conditions must be evaluated. Antenna Gain (2.4GHz) = 5dBi (Numeric = 3.162), rr = 3.14 Antenna Gain (5GHz) = 5dBi (Numeric = 3.162), rr = 3.14 Frequency (MHz) Output Power (dBm) Output Power (mW) Power Density (mW/cm 2) PowerDensity Limit (mW/cm 2) 2422 15.24 33.4195040026 0.021 1 5240 (Band 1) 15.68 36.982817978 0.023 1 5795 (Band 4) 15.03 31.8419752173 0.020 1 Note: Only the worst case recorded.
Report No.: AAEMT/RF/230301-01-05 1 | P a g e Plot No.174, Udyog Vihar Phase 4, Sector -18, Gurgaon -122016, Haryana, India Contact:0124-4235350, 4145343; e-mail: info @aaemtlabs.com; Website: www.aaemtlabs.com Decision Rule: The result of conformity based on the mentioned standards actual test limits / levels AAEMT/A2LA/TRF/FCC-15E/22_01_REV1 AA Electro Magnetic Test Laboratory Private Limited Certificate#5593.01 FCC RADIO TEST REPORT Part 15 subpart E FCC ID:2AZOI4XIWP Report Reference No. ........................... : AAEMT/RF/230301-01-05 Date of issue ........................................ : 02/08/2023 Testing Laboratory ............................... : AA Electro Magnetic Test Laboratory Private Limited Address ............................................... : Plot No 174, Udyog Vihar - Phase 4, Sector 18, Gurgaon, Haryana, India Applicant’s name ................................. : HFCL Limited Address ............................................... : Plot no. 38, Institutional Area, Sector 32,Gurgaon -122001 Manufacturer ....................................... : HFCL Limited Test specification: Plot no. 38, Institutional Area, Sector 32,Gurgaon -122001 Test item description............................ : IO Wi-Fi 6 Dual Band 2x2:2 Indoor Wall Plate Access Point with Integrated Antenna (5dBi) Trade Mark.......................................... : Model/Type reference ........................ : ion4xi_WP Ratings ................................................ : Input of PoE: 100-240VAC, 50/60Hz, Output of PoE/input of EUT: +48V (PoE),0.5A/DC +12V, 2A Prepared By: (+ signature) Ankur Kumar Reviewed & Approved by: (+ signature) Dr. Lenin Raja (Authorized Representative) (/ lenin83/) Report No.: AAEMT/RF/230301-01-05 2 | P a g e Plot No.174, Udyog Vihar Phase 4, Sector -18, Gurgaon -122016, Haryana, India Contact:0124-4235350, 4145343; e-mail: info @aaemtlabs.com; Website: www.aaemtlabs.com Decision Rule: The result of conformity based on the mentioned standards actual test limits / levels AAEMT/A2LA/TRF/FCC-15E/22_01_REV1 AA Electro Magnetic Test Laboratory Private Limited Certificate#5593.01 TABLE OF CONTENTS 1. Summary of test results ........................................................................................................................ 5 2. General test information ....................................................................................................................... 6 2.1. Description of EUT .............................................................................................................................. 6 2.2. Accessories of EUT .............................................................................................................................. 7 2.3. Assistant equipment used for test ......................................................................................................... 7 3. Equipment’s List for All Test Items ..................................................................................................... 8 3.1. Block diagram of EUT configuration for test ..................................................................................... 11 3.2. Test environment conditions ............................................................................................................... 11 3.3. Measurement uncertainty ................................................................................................................... 11 4. POWER SPECTRAL DENSITY TEST ............................................................................................ 12 4.1. Block diagram of test setup ................................................................................................................ 12 4.2. Applied procedures / limit .................................................................................................................. 12 4.3. Test Procedure .................................................................................................................................... 13 4.4. Test Result: ........................................................................................................................................ 14 5. 26 dB & 99% Emission Bandwidth .................................................................................................... 42 5.1. Block diagram of test setup ................................................................................................................ 42 5.2. Applied procedures / limit .................................................................................................................. 42 5.3. Test Procedure .................................................................................................................................... 42 5.4. Test Result ......................................................................................................................................... 43 6. MAXIMUM CONDUCTED OUTPUT POWER .............................................................................. 92 6.1. Test Result ......................................................................................................................................... 94 7. Band Edges Measurement .................................................................................................................. 95 7.1. Test Result ......................................................................................................................................... 96 8. RADIATED EMISSION MEASUREMENT .................................................................................. 114 8.1. Block diagram of test setup .............................................................................................................. 114 8.2. Limit ................................................................................................................................................. 116 8.3. Test Procedure …
Text truncated - open the document above for the full version.
Dual Band Internal PCB Omni Antenna (2.4-2.484 GHz & 5.18-5.850 GHz) Electrical Parameters Mechanical Parameters Frequency (MHz) 2400-2484 5180-5850 Gain (dBi) 3.5±0.5 5.5±0.5 VSWR 1.5 : 1 1.5 : 1 E Plane BW (°) Polarization Linear Maximum Power Inputs (Watts) Impedance (Ω) Cable & Connector Termination Dimension (mm) 55 X 12 X 0.8 (T) Gross Weight (Grams) Fixing Method Environmental Parameters Temperature Range (°C) ( - ) 40 to ( + ) 70 HFDBD-PBPCANT-3-5-0.2 2.0 : 1.0 2.0 : 1.0 10 50 197±2 mm 1.13 mm cable UFL Female Connector Release date : 07/02/2023 Version : 1.0 Email: [email protected] | Website: hfcl.com | io.hfcl.com 8, Commercial Complex, Masjid Moth Greater Kailash-II, New Delhi-110048 H Plane BW (°) 70±1 70±1 5±2 3M VHB 4941 70±1 70±1 Dual Band Internal PCB Omni Antenna (2.4-2.484 GHz & 5.18-5.850 GHz) Release date : 07-02-2023 Version : 1.0 Email: [email protected] | Website: hfcl.com | io.hfcl.com 8, Commercial Complex, Masjid Moth Greater Kailash-II, New Delhi-110048
Test Set up above 1 GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.83 GHz | 31.80 mW |
IO Wi-Fi 6 Dual Band 8x8 8 Indoor Access Point with Integrated Antenna (6 dBi) [DC powered]
Equipment Class
NII - Unlicensed National Information Infrastructure TXIO 5Ghz 1000Mbps UBR with External Antenna with dying gasp
Equipment Class
NII - Unlicensed National Information Infrastructure TX
IO Wi-Fi 6 Dual Band 2x2 2 Home Mesh Router with Integrated Antenna (5 dBi)
Equipment Class
DTS - Digital Transmission System
IO Wi-Fi 6 Dual Band 2x2 2 IndoorAccess Point with Integrated Antenna (5 dBi)
Equipment Class
DTS - Digital Transmission System
WiFi Access Point - Dual Band 2x2_2 Wi-Fi 6 Outdoor Access Point (AP) with external Antenna in 2.4Ghz & 5Ghz Band
Equipment Class
DTS - Digital Transmission System