FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong EraClean Technology Co.,Ltd/
  3. 2AZYC-GFC12

2AZYC-GFC12Mini Fruit & Vegetable Cleaner

Guangdong EraClean Technology Co.,Ltd
Mini Fruit & Vegetable Cleaner - FCC ID 2AZYC-GFC12 - Guangdong EraClean Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 10, 2024
Application Purpose
Original Equipment
Date of Application
Sep 05, 2024
Equipment Note
Mini Fruit & Vegetable Cleaner
Frequency Range
0.11500000 - 0.20500000
Company
Guangdong EraClean Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wireless charging output: 5W

Attestation Statements

(GuangdongEraCleanTechnologyCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:September4,2024 FCCID:2AZYC-GFC12 Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing (“GuangdongEraCleanTechnologyCo.,Ltd”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing (“GuangdongEraCleanTechnologyCo.,Ltd”)certifiesthat,asofthedateofthefiling oftheapplication,GuangdongEraCleanTechnologyCo.,Ltdisnotidentifiedonthe CoveredListasanentityproducing“covered”equipment. Applicant:GuangdongEraCleanTechnologyCo.,Ltd Address:3rdFloor,1stBlock,Phase4,HongjiIndustryCity,No.23TongjiWestRoad,Nantou Town,ZhongshanCity ContactPerson:jiezongHE Tel.:15112879145 Email:[email protected] Sincerely, Signature:

Attestation Statements

GuangdongEraCleanTechnologyCo.,Ltd Address:3rdFloor,1stBlock,Phase4,HongjiIndustryCity,No.23TongjiWestRoad,Nantou Town,ZhongshanCity Date:2024-09-04 FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AZYC-GFC12 FRN:0030943138 (“GuangdongEraCleanTechnologyCo.,Ltd”)certifiesthat,asofthedateofthefilingofthe application,GSSSERVICEINCisourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.(“GuangdongEraCleanTechnologyCo.,Ltd”)acceptstomaintain anagentfornolessthanoneyearafterthegranteehasterminatedallmarketingand importationortheconclusionofanyCommission-relatedproceedinginvolvingtheequipment. GSSSERVICEINCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GSSSERVICEINC Address:6547NAcademyBlvd#2266ColoradoSpringsCOLORADO80918UnitedStates FRN:0033402082 ContactPerson:MichouxLogan Tel.:001-949-2990192 Email:[email protected] Sincerely, Signedonbehalfof(GuangdongEraClean TechnologyCo.,Ltd) SignedonbehalfofGSSSERVICEINC Name:jiezongHEName:MichouxLogan Title:TestEngineerTitle:Manager Date:2024-09-04Date:2024-09-04

Cover Letter(s)

SPECIFICATION 産品型號: DESC 版本 Rev:A.0 客戶CUST: 客户料号CUSTP/N Guangdong EraClean Technology Co.,Ltd : 一、尺寸DIMENSION:(mm) A 34.7±0.3 B 30.6±0.5 C 8.2±0.5 D 60.2±2 E 74±2 F 5.2±0.2 G H I K 序号 NO 二、电气特性ELECTRICAL CHARACTERISTICS: 温度TEMPERATURE:25±10°C,湿度RELATIVE HUMIDITY:65±20% . 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TESTFREQUENCY 测试仪器 TESTEQUIPMENTS 1IND.S-F3.7uH±10%单独线圈100KHz/1.0VLCZMETER1062B 2IND.S-F6.5H±10%加磁片100KHz/1.0VLCZMETER1062B 3DCRS-F≤100mΩLCZMETER502B Address:3rd Floor, 1st Block, Phase 4, Hongji Industry City, No.23 Tongji West Road, Nantou Town, Zhongshan City

Cover Letter(s)

GuangdongEraCleanTechnologyCo.,Ltd Date:2024-09-04 ProductModelNumber:GFC12 FCCID:2AZYC-GFC12 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatORGANIZATION.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyORGANIZATION.onourbehalf shallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:TestEngineer Email:[email protected] Telephone:15112879145 Onbehalfof:GuangdongEraCleanTechnologyCo.,Ltd

Cover Letter(s)

GuangdongEraCleanTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:September4,2024 Subject;RequestforConfidentiality FCCID:2AZYC-GFC12 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:jiezongHE Title:TestEngineer

External Photos

FCCID:2AZYC-GFC12 EUTPHOTOS(ExternalPhotos) FCCID:2AZYC-GFC12 FCCID:2AZYC-GFC12 FCCID:2AZYC-GFC12 ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

FCC ID:2AZYC-GFC12

Internal Photos

FCCID:2AZYC-GFC12 EUTPHOTOS(InternalPhotos) FCCID:2AZYC-GFC12 FCCID:2AZYC-GFC12 ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

FCCID:2AZYC-GFC12 ProductName:MiniFruit&VegetableCleaner ProductModelNo.:GFC12 TestAuxiliary:MiniFruit&VegetableCleaner ModelNo.:GFC12 Transmittingmode:KeeptheEUTincontinuouslywirelesschargingmode Powersupply:Input:DC5V,1A Wirelesschargingoutput:5W Note:EUTdoesnotsupportwirelesschargingoutputwhilecharging TestModes: Mode1Wirelesscharging(5W) Mode2Standby Note:1.Allmodesweretested,onlytheworst-casewasrecordedinthereport.Mode1istheworstmode. EUTdoesnotsupportwirelesschargingoutputwhilecharging RFExposureEvaluation 1MeasuringStandard KDB680106D01WirelessPowerTransferv04 2Requirements Accordingtotheitem5ofKDB680106D01v04: Inductivewirelesspowertransferapplicationsthatmeetallofthefollowingrequirementsareexcludedfrom submittinganRFexposureevaluation. (1)Thepowertransferfrequencyisbelow1MHz. TheEUTfrequencyrangeis:115kHz-205kHz. (2)Theoutputpowerfromeachtransmittingelement(e.g.,coil)islessthanorequalto15watts. Theoutputpowerisequalto15W,Onlyonecoil. (3)Aclientdeviceprovidingthemaximumpermittedloadisplacedinphysicalcontactwiththetransmitter (i.e.,thesurfacesofthetransmitterandclientdeviceenclosuresneedtobeinphysicalcontact) EUTcanbedirectlycharged. (4)Only§2.1091-Mobileexposureconditionsapply(i.e.,thisprovisiondoesnotcover§2.1093-Portable exposureconditions). EUTisamobiledevice (5)TheE-fieldandH-fieldstrengths,atandbeyond20cmsurroundingthedevicesurface,aredemonstrated tobelessthan50%oftheapplicableMPElimit,perKDB447498,Table1.Thesemeasurementsshallbe takenalongtheprincipalaxesofthedevice,withoneaxisorientedalongthedirectionoftheestimated maximumfieldstrength,andforthreepointsperaxisoruntila1/d(inversedistancefromtheemitterstructure) fieldstrengthdecayisobserved.Symmetryconsiderationsmaybeusedfortestreductionpurposes.The deviceshallbeoperatedindocumentedworst-casecompliancescenarios(i.e.,theonesthatleadtothe maximumfieldcomponents),andwhilealltheradiatingstructures(e.g.,coilsorantennas)thatbydesigncan simultaneouslytransmitareenergizedattheirnominalmaximumpower. Yes,theEUTfieldstrengthlevelsareless50%xMPElimit. (6)Forsystemswithmorethanoneradiatingstructure,theconditionsspecifiedin(5)mustbemetwhenthe systemisfullyloaded(i.e.,clientsabsorbingmaximumpoweravailable),andwithalltheradiatingstructures operatingatmaximumpoweratthesametime,asperdesignconditions.Ifthedesignallowsoneormore radiatingstructurestobepoweredatahigherlevelwhileotherradiatingstructuresarenotpowered,then thosecasesmustbetestedaswell.Forinstance,adevicemayusethreeRFcoilspoweredat5W,orone coilpoweredat15W:inthiscase,bothscenariosshallbetested. Yes,EUThasonlyonecoil. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) 3TestSetup 4TestProcedure 1)TheRFexposuretestwasperformedinanechoicchamber. 2)Themeasurementprobewasplacedattestdistance(20cmfromallsidesand20cmfromthetop)whichis betweentheedgeofthechargerandthegeometriccenterofprobe. 3)Thehighestemissionlevelwasrecordedandcomparedwithlimitassoonasmeasurementofeachpoints (A,B,C,D,E)werecompleted. 4)TheEUTwasmeasuredaccordingtothedictatesofKDB680106D01v04. Remark:TheEUT’stestpositionA,B,C,DandEisvalidfortheEandHfieldmeasurements. 5TestInstrumentslist TestEquipmentManufacturerModelNo.SN. Cal.Date (mm-dd-yy) Cal.Duedate (mm-dd-yy) MagneticAmplitudeand GradientProbeSystem SPEAG MAGPy-8H3D+E3DV2& MAGPy-DASV2 SZ186-06& 3061 Feb.26,2024Feb.25,2025 6TestResult WehaveevaluatedStandby,5WWirelesschargingmode,andtheworstmode(5W)is showedinthisreport. E-FiledStrengthat20cmfromtheedgessurroundingtheEUT(V/m) FrequencyRange(MHz) Test PositionA Test PositionB Test PositionC Test PositionD 50%Limits (V/m) Limits (V/m) testresult 0.115-0.2050.830.800.790.76307614PASS E-FiledStrengthat20cmfromthetopoftheEUT(V/m) FrequencyRange (MHz) Test PositionE 50%Limits (V/m) Limits (V/m) testresult 0.115-0.2050.81307614PASS H-FiledStrengthat20cmfromtheedgessurroundingtheEUT(A/m) FrequencyRange(MHz) Test PositionA Test PositionB Test PositionC Test PositionD 50%Limits (V/m) Limits (A/m) test result 0.115-0.2050.520.480.440.430.8151.63PASS H-FiledStrengthat20cmfromthetopoftheEUT(A/m) FrequencyRange (MHz) Test PositionE 50%Limits (V/m) Limits (A/m) testresult 0.115-0.2050.300.8151.63PASS 7TestSet-upPhoto

Test Report

ProjectNo.:ZKT-240829L10704E Page 1 of 23 FCCTESTREPORT FCCID:2AZYC-GFC12 ReportNumber...................................:ZKT-240829L10704E DateofTest ........................................... :Aug.14,2024toAug.28,2024 Dateofissue ......................................... :Aug.28,2024 Totalnumberofpages..........................23 TestResult..........................................: PASS TestingLaboratory............................: ShenzhenZKTTechnologyCo.,Ltd. Address...............................................: 1/F,No.101,BuildingB,No.6,TangweiCommunityIndustrial Avenue,FuhaiStreet,Bao'anDistrict,Shenzhen,China Applicant'sname.............................: GuangdongEraCleanTechnologyCo.,Ltd Address...............................................: 3rdFloor,1stBlock,Phase4,HongjiIndustryCity,No.23Tongji WestRoad,NantouTown,ZhongshanCity Manufacturer'sname ...................... :HangzhouShijingTechnologyCo.,Ltd. Address...............................................: Room308,Building5,No.3LianshengRoad,WuchangStreet, YuhangDistrict,Hangzhou,Zhejiang,China Testspecification: Standard................................................:FCCCFRTitle47Part15SubpartC Testprocedure ..................................... : / Non-standardtestmethod................:N/A TestReportFormNo. .......................... : TRF-EL-107_V0 TestReportForm(s)Originator.....: ZKTTesting MasterTRF........................................: Dated:2020-01-06 ThisdevicedescribedabovehasbeentestedbyZKT,andthetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofZKT,thisdocumentmay bealteredorrevisedbyZKT,personalonly,andshallbenotedintherevisionofthedocument. Productname ..................................... :MiniFruit&VegetableCleaner Trademark ........................................... :EraClean Model/Typereference.........................:GFC12 Modeldifference...................................:/ Ratings..................................................:Input:DC5V,1A Wirelesschargingoutput:5W ProjectNo.:ZKT-240829L10704E Page 2 of 23 Testingprocedureandtestinglocation: TestingLaboratory.......................................:ShenzhenZKTTechnologyCo.,Ltd. Address ............................................................ :1/F,No.101,BuildingB,No.6,TangweiCommunity IndustrialAvenue,FuhaiStreet,Bao'anDistrict, Shenzhen,China JimLiu Testedby(name+signature).......................: TomZou Reviewer(name+signature).......................: LakeXie Approved(name+signature).......................: ProjectNo.:ZKT-240829L10704E Page 3 of 23 TABLEOFCONTENTS 1.VERSION..................................................................................................................................4 2.TESTSUMMARY...................................................................................................................5 2.1TESTFACILITY...............................................................................................................................6 2.2MEASUREMENTUNCERTAINTY...............................................................................................6 3.GENERALINFORMATION..................................................................................................7 3.1GENERALDESCRIPTIONOFEUT............................................................................................7 3.2Testmode.........................................................................................................................................7 3.3BlockDiagramofEUTConfiguration...........................................................................................7 3.4TestConditions................................................................................................................................7 3.5DescriptionOfSupportUnits(ConductedMode).......................................................................8 3.6EQUIPMENTSLISTFORALLTESTITEMS.............................................................................9 4.CONDUCTEDEMISSIONTEST........................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT...........................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits..................................................................11 4.1.2TESTPROCEDURE..................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................................11 4.1.4TESTSETUP..............................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS............................................................................................12 4.1.6TestResult..................................................................................................................................12 5.RADIATEDEMISSIONMEASUREMENT.......................................................................15 5.1RadiatedEmissionLimits.............................................................................................................15 5.2AnechoicChamberTestSetupDiagram...................................................................................16 5.3TestProcedure..............................................................................................................................16 5.4DEVIATIONFROMTESTSTANDARD.....................................................................................16 5.5TestResult......................................................................................................................................17 6.BANDWIDTHTEST..................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AZYC-GFC12 EUTTESTPHOTO FCCID:2AZYC-GFC12 ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

jiezong HE(Test Engineer)
[email protected]15112879145Fax: 15112879145

Technical Contact

Guangdong EraClean Technology Co.,Ltd
[email protected]

China

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Guangdong EraClean Technology Co.,Ltd

Intelligentdeodorizer Max - FCC ID 2AZYC-CWBS01 - Guangdong EraClean Technology Co.,Ltd
2AZYC-CWBS01

Intelligentdeodorizer Max

May 24, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter