FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Kaida Technology Co., LTD/
  3. 2BAM4-PC-AAC19

2BAM4-PC-AAC19mini-pc

Shenzhen Kaida Technology Co., LTD
mini-pc - FCC ID 2BAM4-PC-AAC19 - Shenzhen Kaida Technology Co., LTD
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 12, 2023
Application Purpose
Original Equipment
Date of Application
Apr 12, 2023
Equipment Note
mini-pc
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Kaida Technology Co., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CPU Intel® Jasper Lake N5095/N5105 OS Support Windows11、10/Linux Memory 2* DDR4 SO-DIMM (32G Max) M.2 SSD 1*M.2 2280 SSD (Support PCIE /SATA,Default SATA) HDD 2.5” HDD ( optional ) Display HDMI x 1 / DP x 1 / TYPE-C x 1 Wireless On Board 2.4GHz/5GHz Wifi Module IO USB3.0×4 Type-C×1 LAN 2 x RJ45 1000M LAN TF Card x 1(optional) Audio 1 x 2-Audio Connectors (Audio&Mic) DC 12V/3A Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC Radiation exposure limit set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Attestation Statements

Shenzhen Kaida Technology Co., LTD 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Kaida Technology Co., LTD Address: 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Product Name: mini-pc FCC ID: 2BAM4-PC-AAC19 Model(s): PC-AAC19, PC-K001, PC-K002, PC-K003, PC-K004, PC-K005, PC-D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC-C020, PC-N031, PC-N034 2.911(d)(5)(i) Equipment Type We, [Shenzhen Kaida Technology Co., LTD] certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Weimeng Luo Date:Apr. 10, 2023 Title and Company name: manager/ Shenzhen Kaida Technology Co., LTD NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Kaida Technology Co., LTD 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Kaida Technology Co., LTD Address: 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Product Name: mini-pc FCC ID: 2BAM4-PC-AAC19 Model(s): PC-AAC19, PC-K001, PC-K002, PC-K003, PC-K004, PC-K005, PC-D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC-C020, PC-N031, PC-N034 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Kaida Technology Co., LTD] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Weimeng Luo Date:Apr. 10, 2023 Title and Company name: manager/ Shenzhen Kaida Technology Co., LTD NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Kaida Technology Co., LTD 2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: Shenzhen Kaida Technology Co., LTD Address: 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Product Name: mini-pc FCC ID: 2BAM4-PC-AAC19 Model(s): PC-AAC19, PC-K001, PC-K002, PC-K003, PC-K004, PC-K005, PC-D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC-C020, PC-N031, PC-N034 2.911(d)(7) USA Designated Agent for Service of Process We, (Shenzhen Kaida Technology Co., LTD) designate USA Agent for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Linkage Technology, LLC Address: 10601 NEWCOMBE ST BROOMFIELD CO 80021-3630 USA FRN Number: 0033401480 Contact Name:Candy Jones Telephone No:+01-509-768-2249 Email:[email protected] Applicant Company name: Shenzhen Kaida Technology Co., LTD Address: 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen FCC Grantee Code: 2BAM4 Contact Name:Wemeng Luo Telephone No:13530302961 Email:[email protected] Shenzhen Kaida Technology Co., LTD 2.911 (d)(7)USA Agent v1.2 Signature: Title: manager Signature: Title: manager Date: Apr. 10, 2023 Date: Apr. 10, 2023 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

Shenzhen Kaida Technology Co., LTD Agent Authorization Company: Shenzhen Kaida Technology Co., LTD Address: 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Product Name: mini-pc Model Number(s): PC-AAC19, PC-K001, PC-K002, PC-K003, PC-K004, PC-K005, PC- D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC-C020, PC-N031, PC-N034 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Date: Apr. 10, 2023 Signature: Name: Weimeng Luo Title: manager Company: Shenzhen Kaida Technology Co., LTD

Cover Letter(s)

Shenzhen Kaida Technology Co., LTD Date: Apr. 10, 2023 Offic e of Engineering Technology Federal Communications Commission 743 5 Oakland Mill s Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2BAM4-PC-AAC19 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705 . OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: WeiMeng Luo Title: manager Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure FCC Software Security Requirements for UNII devices

Cover Letter(s)

Project No.: ZKT-230307L1354-01 FCC ID: 2BAM4-PC-AAC19 Difference Statement We Shenzhen Kaida Technology Co., LTD Claim that we are applying for FCCID certification for products: mini-pc, with many models: PC-AAC19, PC-K001, PC-K002, PC- K003, PC-K004, PC-K005, PC-D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC- C020, PC-N031, PC-N034 Motherboard circuits, such as BOMs and PCBs, are consistent, but there may be differences in configuration (such as CPU model,main model-CPU is N5105 and N5095 for series models, memory size, hard disk size, display screen size, etc.), resulting in different models, or different models due to different customer requirements. However, these differences do not affect the EMC/RF performance of the product itself. The CPU model for this test is N5105, memory: 8G+256, and model: PC-AAC19 Date: 2023-04-10 Name: Weimeng Luo Title: manager Signature of applicant

External Photos

FCC ID: 2BAM4-PC-AAC19 External photos FCC ID: 2BAM4-PC-AAC19 FCC ID: 2BAM4-PC-AAC19 FCC ID: 2BAM4-PC-AAC19 FCC ID: 2BAM4-PC-AAC19

ID Label/Location Info

FCC ID: 2BAM4-PC-AAC19 Label place SIZE: 20*40mm mini-pc (Suitable for DC12V-3A adapter) MODEL: PC-AAC19 INPUT: DC 12V 3A FCC ID: 2BAM4-PC-AAC19

Internal Photos

FCC ID: 2BAM4-PC-AAC19 Internal photos BT&WIFI ANT WIFI ANT FCC ID: 2BAM4-PC-AAC19 FCC ID: 2BAM4-PC-AAC19

RF Exposure Info

FCC ID: 2BAM4-PC-AAC19 RF Exposure Evaluation Applicable standard FCC KDB447498 D01 General RF Exposure Guidance v06: Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices. Limits According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b) F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Result of RF Exposure Evaluation EDR/BLE-FPC ANT: 1.24 dBi 2.4G- WIFI ANT1 & ANT2: 1.24dBi; MIMO Gain: 4.25 dBi 5G- WIFI ANT1 & WIFI ANT2: 3.46dBi; MIMO Gain: 6.47 dBi Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.0 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Measurement Data The Max Conducted Peak Output Power data refer to report Report No.: ZKT-230307L1354-01 & ZKT-230307L1354-02 & ZKT-230307L1354-03 & ZKT-230307L1354-04 BT/BLE-worst mode and channel: Test channel Output Power (dBm) Tune up tolerance (dBm) Maximum tune-up Power Calculated value (mW/cm2) (dBm) (mW) (BT) GFSK Low channel 1.12 2±1 3 1.995 0.000528 (BLE-1Mbps)GFSK Lowest channel -0.84 0±1 1 1.259 0.000333 Limit: 1.0 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+ BLE 0.000528+0.000333 0.00086 1.0 conclusion : 0.00086<1.0, So there is no sar requirement 2.4GWIFI-worst mode and channel: Test channel Antenna Output Power (dBm) Tune up tolerance (dBm) ANT1 ANT2 SUM ANT1 ANT2 SUM 802.11n –2462MHz 20.61 19.75 23.21 20±1 20±1 23.01±1 Test worst case Maximum tune-up Power (dBm) Maximum tune-up Power (mW) Calculated value (mW/cm2) Limit (mW/cm2) ANT1 ANT2 SUM ANT1 ANT2 SUM / / 21 21 24.01 125.89 125.89 251.79 0.13328 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-230307L1354-03 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 251.79 *2.6607)/(4*3.14159*20*20)=0.13328, G=10 gain/10 = 2.6607 5GWIFI- worst mode and channel: Mode Test channel Antenna Output Power (dBm) Tune up tolerance (dBm) Max Tune up (dBm) ANT1 ANT2 SUM ANT1 ANT2 SUM 802.11ac- 5200MHz 6.39 6.44 9.43 7±1 7±1 10.01±1 11.01 802.11n-5745MHz 16.04 15.69 18.88 16±1 16±1 19.01±1 20.01 Test worst case Maximum tune-up Power (dbm) Maximum tune-up Power (mW) Calculated value (mW/cm2) Limit (mW/cm2) 20.01 100.24 0.0885 1.0 Remark: 1)The Max Conducted Peak Output Power data refer to report Report No.: ZKT-230104L0116-04 2) Pd = (Pout*G)/(4* Pi * R 2 )=( 100.24*4.4361)/(4*3.14159*20*20)= 0.0885, G=10 gain/10 =4.4361 EUT RF Exposure Evaluation simultaneous transmission operations According to 865664D02 2.2 d) 1): The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits : Simultaneous transmission mode The sum of the ratios SUM Limit BT+2.4G WIFI + 5G WIFI 0.00086+0.13328+0.0885 ≈0.223 1.0 conclusion : 0.223 < 1.0, So there is no sar requirement NOTE: 1. EUT is more than 20cm away from the human body. 2. The sum of the ratios(2.4GWIFI + 5G WIFI+BT) is less than the limit value of 1.0, so there is no sar requirement.

Test Report

Project No.: ZKT-230307L1354-01 Page 1 of 69 FCC TEST REPORT FCC ID: 2BAM4-PC-AAC19 Report Number. .............................. : ZKT-230307L1354-01 Date of Test ..................................... : Mar. 07, 2023 -- Mar. 31, 2023 Date of issue .................................... : Mar. 31, 2023 Total number of pages ..................... : 69 Test Result ..................................... : PASS Testing Laboratory. ....................... : Shenzhen ZKT Technology Co., Ltd. Address .......................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Applicant's name ......................... : Shenzhen Kaida Technology Co., LTD Address .......................................... : 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Manufacturer's name ................... : Shenzhen Kaida Technology Co., LTD Address .......................................... : 4 / F, building C, No. 9, Huayuan Xincun Avenue, xiangjiaotang community, Bantian street, Longgang District, Shenzhen Test specification: Standard .......................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test procedure ................................. : KDB558074 D0115.247 Meas Guidance v 05r02 Non-standard test method ............. : N/A Test Report Form No. .................... : TRF-EL-112_V0 Test Report Form(s) Originator .... : ZKT Testing Master TRF .................................... : Dated: 2020-01-06 This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document. Product name ................................. : mini-pc Trademark ...................................... : N/A Model/Type reference ...................... : PC-AAC19, PC-K001, PC-K002, PC-K003, PC-K004, PC-K005, PC-D006, PC-D007, PC-D008, PC-D009, PC-D10, PC-B011, PC-B012, PC-B013, PC-B014, PC-B015, PC-C016, PC-C017, PC-C018, PC-C019, PC-C020, PC-N031, PC-N034 Ratings ............................................. : DC12.0V-3A 36W from adapter Project No.: ZKT-230307L1354-01 Page 2 of 69 Testing procedure and testing location: Testing Laboratory .................................. : Shenzhen ZKT Technology Co., Ltd. Address ...................................................... : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China Alen He Tested by (name + signature) .................... : Joe Liu Reviewer (name + signature) ..................... : Lake Xie Approved (name + signature) .................... : Project No.: ZKT-230307L1354-01 Page 3 of 69 Table of Contents Page 1. VERSION .............................................................. 5 2. TEST SUMMARY ........................................................ 6 3. GENERAL INFORMATION ............................................... 7 3.1 GENERAL DESCRIPTION OF EUT ........................................ 7 3.2 Test Setup Configuration .................................................. 8 3.3 Support Equipment ....................................................... 8 3.4 Test Mode .............................................................. 9 3.5 EQUIPMENTS LIST FOR ALL TEST ITEMS ................................ 10 4. EMC EMISSION TEST .................................................. 11 4.1 Conducted emissions .................................................... 11 4.1.1 POWER LINE CONDUCTED EMISSION Limits ........................... 11 4.1.2 TEST PROCEDURE ................................................... 11 4.1.3 DEVIATION FROM TEST STANDARD ................................... 11 4.1.4 TEST SETUP ......................................................... 11 4.1.5 EUT OPERATING CONDITIONS ........................................ 11 4.1.6 Test Result ........................................................... 12 4.2 Radiated emissions ..................................................... 14 4.2.1 Radiated Emission Limits ............................................... 14 4.2.2 TEST PROCEDURE ................................................... 14 4.2.3 DEVIATION FROM TEST STANDARD ................................... 15 4.2.4 TEST SETUP ......................................................... 15 4.2.5 EUT OPERATING CONDITIONS ........................................ 16 4.2.6 TEST RESULTS ...................................................... 17 5. RADIATED BAND EMISSION MEASUREMENT ............................ 22 5.1 Test Requirement: ...................................................... 22 5.2 TEST PROCEDURE .................................................... 22 5.3 DEVIATION FROM TEST STANDARD .................................... 23 5.4 TEST SETUP .......................................................... 23 5.5 EUT OPERATING CONDITIONS ......................................... 23 5.6 TEST RESULT ......................................................... 24 6. CONDUCTED BAND EDGE AND SPURIOUS EMISSION .................... 26 6.1 Limit ................................................................... 26 6.2 Test Setup ............................................................. 26 6.3 Test procedure ......................................................... 26 6.4 DEVIATION FROM STANDARD .......................................... 26 6.5 Test Result ............................................................. 26 7. 20DB BANDWIDTH ..................................................... 27 7.1 Test Setup ..................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen QinXin Technology Co.,Ltd Antenna test report V1.0 联系方式: [email protected] [email protected] 射频: 日期: 2020.08.28 Model/Part No.:W699-1B-B •The antenna characteristics use the microwave anechoic chamber of the ETS test system, the size of the microwave anechoic chamber is 7m x 4m x 3m, and •the test frequency is 700MHz---6GHz. •S11 testing using Agilent E5071B network analyzer testing environment ANT PLACE WIFI-1 WIFI-2 2.4G+5G 2.4G WiFi antenna efficiency WIFI1&WIFI2 240022.81-6.42-1.75 241025.21-5.98-1.4 242028.32-5.48-0.95 243031.58-5.01-0.67 244033.43-4.76-0.69 245034.92-4.57-0.64 246033.74-4.72-0.45 247036.21-4.410.4 248040.05-3.971.04 249042.88-3.681.24 250043.67-3.61.1 Passive Test For WII2.4 FreqEffiEffiGain (MHz)(%)(dB)(dBi) 5GWiFi antenna efficiency WIFI-1 Passive Test For WII5.8 FreqEffiEffiGainFreqEffiEffiGainFreqEffiEffiGain (MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi)(MHz)(%)(dB)(dBi) 515051.97-2.84 4.37 539049.56-3.053.82563044.52-3.513.88 516046.77-3.34.31540057.25-2.424.23564046.08-3.363.76 517042.08-3.763.73541061.23-2.134.43565048.03-3.184.37 518041.68-3.83.61542063.63-1.964.62566046.75-3.33.68 519054.5-2.64 4.32 543058.09-2.364.17567047.14-3.273.94 520049.64-3.044.12544058.13-2.364568042.99-3.673.7 521047-3.283.73545055.79-2.534.07569043.1-3.664.03 522040-3.983.17546056.35-2.494.08570043.07-3.664.1 523042.48-3.723.88547057.96-2.374.14571041.35-3.843.63 524049.41-3.064.21548056.61-2.474.15572041.28-3.843.25 525047.93-3.194.17549058.71-2.314.33573041.37-3.833.84 526048.4-3.154.39550056.34-2.494.15574038.95-4.13.55 527041.27-3.843.71551052.91-2.763.97575037.52-4.263.46 528041.83-3.793.47552056.8-2.464.24576033.57-4.742.54 529046.52-3.324.16553052.5-2.83.92577034.15-4.672.8 530044.45-3.523.83554057.83-2.384.41578031.29-5.052.33 531052.28-2.824.49555055.74-2.544.26579032.09-4.942.38 532050.63-2.964.77556052.28-2.824.12580030.28-5.192.02 533045.85-3.393.9557051.36-2.894.03581028.18-5.51.81 534049.91-3.024.24558049.02-3.13.89582027.16-5.661.73 535047.56-3.233.82559051.58-2.884.24583026.13-5.831.7 536056.41-2.494.53560051.5-2.884.35584025.63-5.911.35 537057.1-2.434.96561048.62-3.134585024.75-6.061.62 538052.33-2.814.31562049.33-3.074.07

Test Setup Photos

FCC ID: 2BAM4-PC-AAC19 Radiated Emission FCC ID: 2BAM4-PC-AAC19 Conducted Emission

Contact Information

Applicant

WeiMeng Luo(manager)
[email protected]13530302961Fax: 0755-33563021

Technical Contact

Shenzhen Kaida Technology Co., LTD
[email protected]

China

Test Firm

Shenzhen ZKT Technology Co., Ltd.Lake Xie
[email protected]0086-13620010775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.29 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shenzhen Kaida Technology Co., LTD

Tablet PC - FCC ID 2BAM4-K110 - Shenzhen Kaida Technology Co., LTD
2BAM4-K110

Tablet PC

May 09, 2023

Equipment Class

DTS - Digital Transmission System
Laptop - FCC ID 2BAM4-D-1420 - Shenzhen Kaida Technology Co., LTD
2BAM4-D-1420

Laptop

Mar 27, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX