FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD./
  3. 2BAQY-SVANAR1R

2BAQY-SVANAR1RTrue Wireless Earbuds

HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
True Wireless Earbuds - FCC ID 2BAQY-SVANAR1R - HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 25, 2026
Application Purpose
Original Equipment
Equipment Note
True Wireless Earbuds
Frequency Range
2402.00000000 - 2480.00000000
Company
HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Svanar Wireless 2 Owner’s Guide Topology Diaphragm Balanced amplifier built-in 1 Overview Power On/Off 1 2 3 4 5 6 Touch Pad Microphone Charging Case Indicator Light inside Charging Case Indicator Light outside Charging Case Hard Key The earbuds will instantly power on when removed from the charging case. The earbuds will automatically start recharging when returned to the charging case, and turn off when fully charged. ⑤ ③ ② ② ⑥ ① ① ④ 2 Pairing 1. To pair with a source device, remove the earbuds from the charging case, at which point the earbuds will enter pairing mode. 2. Open the Bluetooth function menu on your device and select HIFIMAN SVANAR WIRELESS. Once paired, you will hear "Connected.” Important: You have 3 minutes to connect the earbuds to your device, otherwise the earbuds will exit and automatically power off . Leave the right earbud in the charging case while removing the left earbud, at which point it will automatically enter single-sided mode. The left one taken out from the charging case will enter one-sided mode automatically. To return to stereo, simply remove the right earbud from the charging case. Use Left Earbud Only Use Both Earbuds Leave the left earbud in the charging case while removing the right earbud, at which point it will automatically enter single-sided mode. The right one taken out from the charging case will enter one-sided mode automatically. To return to stereo, simply remove the left earbud from the charging case. Use Right Earbud Only 3 Pairing When wearing both earbuds, press and hold both earbuds for 3 seconds at the same time to forcibly cancel the last connected device. After canceling the connection, the headset will enter pairing mode with a voice prompt: "Pairing." Return the earbuds to the charging case, press and hold the hard key of the charging case for 3 seconds while the cover is open. The red and green lights on the charging case will flash and enter the forced pairing mode. The mobile phone will find and connect with Svanar Wireless. After the pairing is completed, the green light in the charging case flashes once, for one second, and turns off. Forced Reconnection Delete Pairings and Restore Factory Settings Return the earbuds are placed in the charging case, then re-open the charging case and press and hold the hard key for 10 seconds. When the reset is completed, the green light in the charging box will flash. 4 Music Calls Answer call Double-click either earbud twice to answer the call End call While in a call, double -click either earbud twice to end the call Reject call Press and hold either earbud for ~3 seconds to reject the call Long press the right earbud (R) for ~3 seconds to turn on the voice assistant (Note: the device needs to support the Voice Assistant function.) To Play/Pause Touch the right/left earbud to pause the track, and touch it again to continue playing the file or stream. To rewind to the previous track With earbuds in operation, double-click the right earbud/left earbud. To Skip to the Next Track With earbuds in operation, triple-click the right earbud/left earbud. Calls & Music Due to the complexity of the electromagnetic environment, LDAC and LHDC high-resolution Bluetooth connection format may freeze or disconnect due to insufficient bandwidth. If this occurs, enter Settings on your device and manually set the Bluetooth format to AAC or SBC. In this mode, the problem of lag/disconnection will be improved, but the sound quality might be less impactful. * L2HC Due to the complexity of the electromagnetic environment, LDAC and LHDC high-resolution Bluetooth connection format may freeze or disconnect due to insufficient bandwidth. If this occurs, enter Settings on your device and manually set the Bluetooth format to AAC or SBC. In this mode, the problem of lag/disconnection will be improved, but the sound quality might be less impactful. 5 Mode Switch Noise Cancellation/HIFI Mode/ Transparency Mode Only when wearing both earbuds: The initial mode is High Fidelity when Svanar Wireless is turned on. Press and hold the left earbud for 3 seconds to switch to Noise Cancellation mode, which is accompanied by a voice prompt: "ANC ON." Press the left earbud for 3 seconds to switch to the Transparency mode, which is accompanied by a voice prompt: "Transparency." Press the left earbud for 3 seconds to switch to High Fidelity mode, accompanied by a voice prompt: "High Fidelity." Note: When using a single earbud, the current mode remains unchanged, and does not support mode switching between Noise Cancellation /High Fidelity /Transparency. When in Noise Cancellation mode, the microphone is no longer picking up for noise cancellation effect. When both earbuds are worn, Svanar Wireless will automatically restore the connection and mode-switching function. 6 Charging Low Battery Alert When the battery falls below 10% power, you will hear the "Low battery, please charge" prompt every 2 minutes. Return the earbuds to the charging case. The headset will automatically shut down after it is fully charged. Charge the Earbuds Indicator Light Inside the Charging Case for Earbuds Battery Status Fully charged Green Light on for 10 seconds Red Light flashes for 10 seconds Not fully charged Yellow Light on for 10 seconds When the charging case is opened, there are no earbuds in the case and the inner light is not on. The charging case battery is too low to charge the earbuds 7 Charging Indicator Light Outside the Charging Case for Charging Case Battery Status Battery >80%Green Light Red Light Light off Battery 20-80% Yellow Light Battery<20% Battery=100% Plug the charging cable into the charger port to charge the charging case and earbuds. When charging, the Indicator Light on the charging box remains illuminated, indicating the battery status of the charging case. Charge the Charging Case 8 Specifications Earphone Specifications Charging Case Specifications Size Charging port USB Type-C Charging Time 2-2.5 H Charging case Charging Ear…

Text truncated - open the document above for the full version.

Attestation Statements

HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. 2nd floor, Building C1, Shangkun Zhichuang Industrial Park, No.2001 Yingbin West Road, Bacheng Town Kunshan, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/08 /19 U.S. Agent Designation Name and company of U.S. agent: DAME INC HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID:2BAQY-SVANAR1R): Physical U.S. address of agent: 19 Preston St, Unit 1, Goffstown NH 03045 NH, NH 3045 United States FRN of U.S. agent: 0036816189 Phone of U.S. agent: (603) 867-6886 Email address of U.S. agent: [email protected] DAME INC acknowledges their obligation to accept service of process on behalf of HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. with the FRN [0033602756] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission- related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature yuchun zhang Manager HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. Signature Liangshu Zhang Manager DAME INC 48_[mo del] US_Agent_2.911(d)(7) -U, V0 5

External Photos

FCC ID: 2BAQY-SVANAR1R External Photos of the EUT FCC ID: 2BAQY-SVANAR1R FCC ID: 2BAQY-SVANAR1R FCC ID: 2BAQY-SVANAR1R FCC ID: 2BAQY-SVANAR1R FCC ID: 2BAQY-SVANAR1R

ID Label/Location Info

Label and Location Size: L: 1.0cm*W: 0.2cm Label and Location FCC ID : 2BAQY-SVANAR1R

Internal Photos

FCC ID: 2BAQY-SVANAR1R Internal Photos of the EUT Left ANT FCC ID: 2BAQY-SVANAR1R FCC ID: 2BAQY-SVANAR1R

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID............................................. : CTA26071502003 2BAQY-SVANAR1R Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 21, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. Address............................................ : 2nd floor, Building C1,Shangkun Zhichuang Industrial Park,No.2001 Yingbin West Road, Bacheng Town Kunshan, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : True Wireless Earbuds Trade Mark ....................................... : N/A Manufacturer .................................... : Xingman Intelligent Technology Co., Ltd Model/Type reference ...................... : Svanar wireless 2-L Listed Models ................................... : N/A Rating ............................................... : Earphone: DC 3.7V, 0.3145mAh From battery and DC 5V From charging box Charging box: DC 3.7V, 800mAh From battery and 5V0.5A Result ............................................... : PASS Report No.: CTA26071502003 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : True Wireless Earbuds Model /Type : Svanar wireless 2-L Listed Models : N/A Applicant : HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. Address : 2nd floor, Building C1,Shangkun Zhichuang Industrial Park,No.2001 Yingbin West Road, Bacheng Town Kunshan, China Manufacturer : Xingman Intelligent Technology Co., Ltd Address : 3rd Floor, Building 13, Fuqiao District 1, Fuhai Street, Bao'an District, Shenzhen City, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26071502003 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 8 4.3 Manufacturing tolerance .......................................................................................... 8 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA26071502003 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuh…

Text truncated - open the document above for the full version.

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA26071502002 2BAQY-SVANAR1R Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 21, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. Address ............................................ : 2nd floor, Building C1,Shangkun Zhichuang Industrial Park,No.2001 Yingbin West Road, Bacheng Town Kunshan, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : True Wireless Earbuds Trade Mark ....................................... : N/A Manufacturer .................................... : Xingman Intelligent Technology Co., Ltd Model/Type reference ...................... : Svanar wireless 2-L Listed Models ................................... : N/A Modulation ....................................... : GFSK, π/4DQPSK, 8DPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : Earphone: DC 3.7V, 0.3145mAh From battery and DC 5V From charging box Charging box: DC 3.7V, 800mAh From battery and 5V0.5A Result ............................................... : PASS Report No.: CTA26071502002 Page 2 of 33 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : True Wireless Earbuds Model /Type : Svanar wireless 2-L Listed Models : N/A Applicant : HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. Address : 2nd floor, Building C1,Shangkun Zhichuang Industrial Park,No.2001 Yingbin West Road, Bacheng Town Kunshan, China Manufacturer : Xingman Intelligent Technology Co., Ltd Address : 3rd Floor, Building 13, Fuqiao District 1, Fuhai Street, Bao'an District, Shenzhen City, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26071502002 Page 3 of 33 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description ........................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Facility........................................................................................................................................ 7 3.3 Environmental condi…

Text truncated - open the document above for the full version.

Test Report

1 FCC Appendix RF Test Data for BT FCC ID : 2BAQY-SVANAR1R Company : HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD. EUT : True Wireless Earbuds Model Number : Svanar wireless 2-L Report No. : CTA26071502002 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.957 2401.544 2402.501 --- --- 2441 0.948 2440.550 2441.498 --- --- 2480 0.924 2479.550 2480.474 --- --- 2DH5 Ant1 2402 1.296 2401.373 2402.669 --- --- 2441 1.284 2440.376 2441.660 --- --- 2480 1.329 2479.343 2480.672 --- --- 3DH5 Ant1 2402 1.335 2401.346 2402.681 --- --- 2441 1.290 2440.364 2441.654 --- --- 2480 1.296 2479.364 2480.660 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 6 3DH5_Ant1_2480 7 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.86235 2401.5795 2402.4418 --- --- 2441 0.85295 2440.5786 2441.4315 --- --- 2480 0.85879 2479.5796 2480.4384 --- --- 2DH5 Ant1 2402 1.1927 2401.4145 2402.6072 --- --- 2441 1.1840 2440.4176 2441.6016 --- --- 2480 1.1864 2479.4176 2480.6040 --- --- 3DH5 Ant1 2402 1.1852 2401.4201 2402.6053 --- --- 2441 1.1833 2440.4247 2441.6080 --- --- 2480 1.1928 2479.4161 2480.6089 --- --- 8 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 9 2DH5_Ant1_2402 2DH5_Ant1_2441 10 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 11 3DH5_Ant1_2480 12 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 0.19 ≤20.97 PASS 2441 0.10 ≤20.97 PASS 2480 -0.13 ≤20.97 PASS 2DH5 Ant1 2402 -0.72 ≤20.97 PASS 2441 -0.75 ≤20.97 PASS 2480 -0.93 ≤20.97 PASS 3DH5 Ant1 2402 -0.23 ≤20.97 PASS 2441 -0.31 ≤20.97 PASS 2480 -0.63 ≤20.97 PASS 13 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 1.038 ≥0.957 PASS 2DH5 Ant1 Hop 1.048 ≥0.886 PASS 3DH5 Ant1 Hop 0.996 ≥0.890 PASS 14 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 15 16 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.407 319 0.13 ≤0.4 PASS DH3 Ant1 Hop 1.662 163 0.271 ≤0.4 PASS DH5 Ant1 Hop 2.910 108 0.314 ≤0.4 PASS 2DH1 Ant1 Hop 0.415 316 0.131 ≤0.4 PASS 2DH3 Ant1 Hop 1.668 162 0.27 ≤0.4 PASS 2DH5 Ant1 Hop 2.916 112 0.327 ≤0.4 PASS 3DH1 Ant1 Hop 0.415 318 0.132 ≤0.4 PASS 3DH3 Ant1 Hop 1.666 160 0.267 ≤0.4 PASS 3DH5 Ant1 Hop 2.916 108 0.315 ≤0.4 PASS 17 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 18 DH5_Ant1_Hop 19 2DH1_Ant1_Hop 2DH3_Ant1_Hop 20 2DH5_Ant1_Hop 21 3DH1_Ant1_Hop 3DH3_Ant1_Hop 22 3DH5_Ant1_Hop 23 24 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS 25 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 26 27 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -0.58 -50.25 ≤-20.58 PASS High 2480 -0.09 -57.52 ≤-20.09 PASS Low Hop_2402 -3.98 -57.7 ≤-23.98 PASS High Hop_2480 -3.57 -55.3 ≤-23.57 PASS 2DH5 Ant1 Low 2402 -3.31 -55.72 ≤-23.31 PASS High 2480 -3.81 -58.02 ≤-23.81 PASS Low Hop_2402 -6.30 -57.72 ≤-26.3 PASS High Hop_2480 -3.88 -57.6 ≤-23.88 PASS 3DH5 Ant1 Low 2402 -4.45 -56.69 ≤-24.45 PASS High 2480 -3.62 -54.87 ≤-23.62 PASS Low Hop_2402 -5.30 -56.24 ≤-25.3 PASS High Hop_2480 -3.74 -57.74 ≤-23.74 PASS 28 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 29 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 30 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 31 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 32 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 33 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -0.36 -0.36 --- PASS 30~1000 -0.36 -69.52 ≤-20.36 PASS 1000~26500 -0.36 -40.58 ≤-20.36 PASS 2441 Reference -1.10 -1.10 --- PASS 30~1000 -1.10 -68.93 ≤-21.1 PASS 1000~26500 -1.10 -41.52 ≤-21.1 PASS 2480 Reference -0.36 -0.36 --- PASS 30~1000 -0.36 -67.4 ≤-20.36 PASS 1000~26500 -0.36 -40.44 ≤-20.36 PASS 2DH5 Ant1 2402 Reference -5.65 -5.65 --- PASS 30~1000 -5.65 -65.96 ≤-25.65 PASS 1000~26500 -5.65 -47.22 ≤-25.65 PASS 2441 Reference -7.14 -7.14 --- PASS 30~1000 -7.14 -68.99 ≤-27.14 PASS 1000~26500 -7.14 -46.76 ≤-27.14 PASS 2480 Reference -4.00 -4.00 --- PASS 30~1000 -4.00 -65.95 ≤-24 PASS 1000~26500 -4.00 -46.74 ≤-24 PASS 3DH5 Ant1 2402 Reference -6.29 -6.29 --- PASS 30~1000 -6.29 -68.55 ≤-26.29 PASS 1000~26500 -6.29 -47.09 ≤-26.29 PASS 2441 Reference -6.22 -6.22 --- PASS 30~1000 -6.22 -67.72 ≤-26.22 PASS 1000~26500 -6.22 -46.65 ≤-26.22 PASS 2480 Reference -3.73 -3.73 --- PASS 30~1000 -3.73 -64.99 ≤-23.73 PASS 1000~26500 -3.73 -45.26 ≤-23.73 PASS 34 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 35 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000

Test Report

36 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 37 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 38 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference 39 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 40 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 41 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 42 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 43 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference 44 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 45 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.91 3.74 77.81 1.09 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 3DH5 Ant1 2402 2.92 3.75 77.87 1.09 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 46 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 47 2DH5_Ant1_2402 2DH5_Ant1_2441 48 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 49 3DH5_Ant1_2480 50 Appendix J: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict DH5 Ant1 Low 2402 AV 2310.000 -60.78 2.69 1.10 38.21 ≤54 PASS AV 2379.170 -58.76 2.69 1.10 40.23 ≤54 PASS AV 2390.000 -59.68 2.69 1.10 39.31 ≤54 PASS Peak 2310.000 -51.3 2.69 0.00 46.59 ≤74 PASS Peak 2355.020 -48.25 2.69 0.00 49.64 ≤74 PASS Peak 2390.000 -50.88 2.69 0.00 47.01 ≤74 PASS High 2480 AV 2483.500 -58.27 2.69 1.10 40.72 ≤54 PASS AV 2484.000 -57.95 2.69 1.10 41.04 ≤54 PASS AV 2500.000 -59.47 2.69 1.10 39.52 ≤54 PASS Peak 2483.500 -50.88 2.69 0.00 47.01 ≤74 PASS Peak 2484.320 -48.19 2.69 0.00 49.70 ≤74 PASS Peak 2500.000 -51.03 2.69 0.00 46.86 ≤74 PASS 2DH5 Ant1 Low 2402 AV 2310.000 -60.31 2.69 1.09 38.67 ≤54 PASS AV 2389.355 -58.68 2.69 1.09 40.30 ≤54 PASS AV 2390.000 -59.66 2.69 1.09 39.32 ≤54 PASS Peak 2310.000 -52.95 2.69 0.00 44.94 ≤74 PASS Peak 2362.475 -48.81 2.69 0.00 49.08 ≤74 PASS Peak 2390.000 -51.25 2.69 0.00 46.64 ≤74 PASS High 2480 AV 2483.500 -58.74 2.69 1.09 40.24 ≤54 PASS AV 2483.840 -58.29 2.69 1.09 40.69 ≤54 PASS AV 2500.000 -59.16 2.69 1.09 39.82 ≤54 PASS Peak 2483.500 -51.62 2.69 0.00 46.27 ≤74 PASS Peak 2493.280 -48.59 2.69 0.00 49.30 ≤74 PASS Peak 2500.000 -51.32 2.69 0.00 46.57 ≤74 PASS 3DH5 Ant1 Low 2402 AV 2310.000 -59.97 2.69 1.09 39.01 ≤54 PASS AV 2366.780 -58.99 2.69 1.09 39.99 ≤54 PASS AV 2390.000 -59.96 2.69 1.09 39.02 ≤54 PASS Peak 2310.000 -52.35 2.69 0.00 45.54 ≤74 PASS Peak 2371.715 -48.66 2.69 0.00 49.23 ≤74 PASS Peak 2390.000 -51.26 2.69 0.00 46.63 ≤74 PASS High 2480 AV 2483.500 -58.53 2.69 1.09 40.45 ≤54 PASS AV 2484.080 -58.46 2.69 1.09 40.52 ≤54 PASS AV 2500.000 -59.73 2.69 1.09 39.25 ≤54 PASS Peak 2483.500 -50.81 2.69 0.00 47.08 ≤74 PASS Peak 2484.960 -48.81 2.69 0.00 49.08 ≤74 PASS Peak 2500.000 -51.54 2.69 0.00 46.35 ≤74 PASS 51 Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 52 Test Graphs DH5_Ant1_Low_2402_AV DH5_Ant1_Low_2402_Peak DH5_Ant1_High_2480_AV 53 DH5_Ant1_High_2480_Peak 2DH5_Ant1_Low_2402_AV 54 2DH5_Ant1_Low_2402_Peak 2DH5_Ant1_High_2480_AV 2DH5_Ant1_High_2480_Peak 55 3DH5_Ant1_Low_2402_AV 3DH5_Ant1_Low_2402_Peak 56 3DH5_Ant1_High_2480_AV 3DH5_Ant1_High_2480_Peak

Test Report

RAIN 电话:1353057660 Shenzhen Yongcheng International Technology Co., LTD 6 第1页 天线规格书 Antennaspecificationforapproval 客户名称 Customername 机型 Model 天线频段 Antennaband 2.4GHZ 天线类型 Antennatype 天线材质 Antenna materia T071-7034-L/R-V1.0 l FPC FPC颜色 FPCcolor 料号 Material number 厂商承认签章 Barenacceptedthesignature 客户承认签章 Clientacknowledgessignature 结构 structure 采购 Purchase 品质 QC 结构 structure 射频 radiofrequency 工程 engineering 审核 Toexamine 品质 QC 盖章区 Sealare 日期 date a 盖章区 Sealare 日期 date a T071-7034-L/R-V1.0 RAIN 电话:1353057660 Shenzhen Yongcheng International Technology Co., LTD 6 第2页 目录 一:Device support & can test antenna types.......1 二:summariz.........................................2 三:Match circuit diagram & machine picture & anten na picture.......................................3 四:Antenna Standing Wave Ratio & Antenna Efficiency (VSWR)...…

Text truncated - open the document above for the full version.

Contact Information

Applicant

yuchun zhang
[email protected]Fax: +8615995644514

Technical Contact

DAME INCLiangshu Zhang
[email protected]

19 Preston St, Unit 1, Goffstown · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.

True Wireless Earbuds - FCC ID 2BAQY-SVANAR2R - HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
2BAQY-SVANAR2R

True Wireless Earbuds

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
Tablet PC - FCC ID 2BAQY-PADONE - HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
2BAQY-PADONE

Tablet PC

Aug 20, 2026

Equipment Class

DTS - Digital Transmission System
2BAQY-TWS450

Bluetooth earbuds

Jan 27, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SVANAR WIRELESS - FCC ID 2BAQY-T050TA201 - HIFIMAN KUNSHAN TECHNOLOGY GROUP CO., LTD.
2BAQY-T050TA201

SVANAR WIRELESS

May 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter