FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sensata Technologies (Changzhou) Co., Ltd./
  3. 2BAW4-AG5PF4

2BAW4-AG5PF4TPMS Sensor

Sensata Technologies (Changzhou) Co., Ltd.
TPMS Sensor - FCC ID 2BAW4-AG5PF4 - Sensata Technologies (Changzhou) Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Feb 05, 2024
Application Purpose
Original Equipment
Date of Application
Feb 05, 2024
Equipment Note
TPMS Sensor
Frequency Range
433.92000000 - 433.92000000
Company
Sensata Technologies (Changzhou) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Hard copy is uncontrolled. AG5PF4 TPM sensor user manual Company Sensata Technologies (Changzhou) CO., LTD. Address No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Destination: External Issue: 01 Date: 03/04/2023 Author: Zhao, Tokin Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. The World Depends on Sensors and Controls Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. Hard copy is uncontrolled. The World Depends on Sensors and Controls Page 2 of 6 Table of Contents 1.PRODUCTION INTRODUCTION .................................................................................................. 3 1.1 PRODUCT FEATURE ............................................................................................................ 3 1.2 CAUTION ............................................................................................................................ 3 1.3 INSTALLATION TIPS ............................................................................................................ 3 2.FCC Regulatory Compliance Statements ................................................................................... 6 3.ISED Regulatory Compliance Statements .................................................................................. 7 AG5PF4 TPM sensor user manual Issue: 01 Date: 03/04/2023 Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. Hard copy is uncontrolled. The World Depends on Sensors and Controls Page 3 of 6 1. Production Introduction 1.1 Product Feature TPMS sensor is used to monitor tyre pressure and temperature data of each tyre. Sensor will transmit RF frames to receiver. Sensor could be activated by LF command or Delta P or motion. 1.2 Caution 1.The tyre’s temperature and pressure will increase while driving. The vehicle should be stopped for colling is there’s a high temp warning and avoid braking problem or tire blowout 2.Driver should stop the vehicle and get off to check the tyre if there’s continue low pressure warning 3.Be aware of tyre blowout when there is low pressure warning 4.The TPM system can effectively monitor tyre pressure and temperature but cannot avoid traffic accident after tyre blowout. Using quality tyre product and correct tyre pressure monitoring is still necessary 5.Be aware of driving safety while checking tyre data on the way of driving 1.3 Installation Tips Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. Hard copy is uncontrolled. The World Depends on Sensors and Controls Page 4 of 6 1.The sensor will be in sleep mode to save battery life. After mounter onto rim, and inflate the tyre to recommend pressure data(RCP from Car manufacturer), sensor will exit sleep mode and enter into stationary mode. 2.If sensor detects motion, wheel rotates to the threshold which could active sensor( e.g. 25km/h), then sensor will transmit RF frames cyclically. 3.Due to the air expansion and contraction, the tyre pressure and temperature will normally changing all the time while driving 4.There is normal air leakage in every tyre rim, TPM sensor should have no responsibility to keep the tyre pressure unchanged after long time storage or driving 1.4 Electronic characteristics Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. Hard copy is uncontrolled. The World Depends on Sensors and Controls Page 5 of 6 1.5 Monitoring Feature NO Component 1 Enclosure 2 Valve Assembly 3 Screw 4 Battery 5 PCB and antenna 6 Pressure port seal 7 Lid Sensata Technologies Inc. Strictly Confidential. © Copyright Sensata Technologies Inc. 2015. All rights reserved. Hard copy is uncontrolled. The World Depends on Sensors and Controls Page 6 of 6 2.FCC Regulatory Compliance Statements Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ●Reorient or relocate the receiving antenna. ●Increase the separation between the equipment and receiver. ●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ●Consult the dealer or an experienced radio/TV technician for help. Caution:Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Radiation Exposure Statement This equipment complies with the FCC portable RF exposure limit set forth for an uncontrolled environment and are safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body or set the device to lower output power if such function is available.

Attestation Statements

<Sensata Technologies (Changzhou) Co., Ltd.> <Sensata Technologies (Changzhou) Co., Ltd.> <No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031> Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA <Jan.18.2024> Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: <2BAW4-AG5PF4> TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, <Sensata Technologies (Changzhou) Co., Ltd.> is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, _______________ (signature & company stamp) <Company: Sensata Technologies (Changzhou) Co., Ltd.> <0033678038> <Address: No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031> <Peter Lu> <+86-18861139066> <[email protected]>

Attestation Statements

<Sensata Technologies (Changzhou) Co., Ltd.> <Sensata Technologies (Changzhou) Co., Ltd.> <No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031> Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA <Jan.18.2024> Attestation Statement according to 2.911(d)(7) FCC ID: <2BAW4-AG5PF4> TO WHOM IT MAY CONCERN: We, <Sensata Technologies (Changzhou) Co., Ltd> designate <FCC US Agent, LLC>, to act as U.S. agent for service of process. <FCC US Agent, LLC > hereby acknowledges the obligation of the U.S. agent for service of process. Further <Sensata Technologies (Changzhou) Co., Ltd> accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely _______________ (signature & company stamp) <Sensata Technologies (Changzhou) Co., Ltd. > <0033678038> <No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031> <Peter Lu> <+86-18861139066> < [email protected] > _______________ (signature & company stamp) <FCC US Agent, LLC> <0033402884> <3722 Illinois Avenue, Saint Charles, IL, 60174, USA> <Tim Payne> <708-571-3148> <[email protected]>

Cover Letter(s)

Sensata Technologies (Changzhou) Co., Ltd. No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 DATE : 2024/01/18 Sensata Technologies (Changzhou) Co., Ltd. No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint below company and person: Name Aaron Zhang Position Manager Company Name Tianjin Dongdian Testing Service Co., Ltd. Address Building D-1, No. 19, Weisi Road, Microelectronics Industrial Park Development Area, Tianjin, China. Tel / Fax Tel: +86-22-58038033 E-Mail [email protected] to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by cetecom advanced GmbH, still resides with: Applicant name Sensata Technologies (Changzhou) Co., Ltd. Address No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Yours sincerely, Signatory Name Peter Lu Position Manager Company Name Sensata Technologies (Changzhou) Co., Ltd. Address No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Tel / Fax 18861139066 E-Mail [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 <2024/01/18> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b) (4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BAW4-AG5PF4 AG5PF4 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos 180 days Internal Photos 180 days Block Diagram Schematics Test Setup Photos 180 days User’s Manual 180 days Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name: Peter Lu Company: Sensata Technologies (Changzhou) Co., Ltd. Address: No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Phone: 18861139066 Fax: E-Mail: [email protected]

External Photos

Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Appendix : EUT photograph #1. Flash - Metal Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E #2. Nvram - Metal Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E

External Photos

Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Appendix : EUT photograph #1. Flash - Rubber Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E #2. Nvram – Rubber Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E

ID Label/Location Info

.---- -- - - --- - ---------, �;;;q I I 1// I I I I I LO � • ,' � � : 1 I co • I I l ('I) t � � FCC ID:2BAW4-AG5PF4 1 11 r.-_J \ co . . I ,� o MADE IN XXXXX : ', , , ', M: AG5PF4 80004372 1' ' ' I ' , , _ -- ---- ---- -� --- - --- -

Internal Photos

Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Appendix : EUT photograph #1. Flash Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Flash(SM946) Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Note:1. The SM946 product printed on the surface is a flash storage type. Antenna

Internal Photos

Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Appendix : EUT photograph #1. Nvram Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Note: 1. The SM1009 product printed on the surface is a NVRAM storage type. Antenna NVRAM(SM1009)

RF Exposure Info

Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 1 of 6 RF EXPOSURE REPORT Report No.: DDT-B24011002-2E02 Issued By: Tianjin Dongdian Testing Service Co., Ltd. Address: Building D-1, No. 19, Weisi Road, Microelectronics Industrial Park, Development Area, Tianjin, China. Tel: +86-22-58038033, E-mail: [email protected], http://www.ddttest.com Applicant : Sensata Technologies (Changzhou) Co., Ltd. Applicant Address : No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Equipment Under Test : TPMS Sensor Model No. : AG5PF4 Trade Mark : FCC ID : 2BAW4-AG5PF4 Manufacturer : Sensata Technologies (Changzhou) Co., Ltd. Manufacturer Address : No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Inspection & Testing Services Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 2 of 6 Table of Contents 1.General information ........................................................................................................ 5 1.1. Description of Equipment ............................................................................................... 5 1.2. Assess laboratory ........................................................................................................... 5 2.RF Exposure Evaluation ................................................................................................ 6 2.1. Requirement ................................................................................................................... 6 2.2. Estimation result ............................................................................................................. 6 Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 3 of 6 Test Report Declare Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Tianjin Dongdian Testing Service Co., Ltd and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Tianjin Dongdian Testing Service Co., Ltd is assumed of full responsibility for the accuracy and completeness of these tests. After test and evaluation, our opinion is that the equipment provided for test compliance with the requirement of the above FCC standards. Report No: DDT-B24011002-2E02 Date of Receipt: Jan. 12, 2024 Date of Test: Jan. 15, 2024 ~ Jan. 20, 2024 Prepared By:Approved By: ____________________ ____________________ Novak Wei/Engineer Aaron Zhang /Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Tianjin Dongdian Testing Service Co., Ltd. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Applicant : Sensata Technologies (Changzhou) Co., Ltd. Address : No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Equipment under Test : TPMS Sensor Model No. : AG5PF4 Trade Mark : FCC ID : 2BAW4-AG5PF4 Manufacturer : Sensata Technologies (Changzhou) Co., Ltd. Address : No. 18, Chuangxin Road, Xinbei District, Changzhou City, Jiangsu, China, 213031 Inspection & Testing Services Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 4 of 6 Revision History Rev. Revisions Issue Date Revised By --- Initial issue Jan. 24, 2024 Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 5 of 6 1.General information 1.1. Description of Equipment EUT Description : TPMS Sensor Model Number : AG5PF4 Serial Number : N/A Hardware Version : 01 Software Version : 01 Sample Type : Vehicle Device EUT function description : Please refer to user manual of this device Power supply : Internal 3V DC 2032 Lithium battery power supply Support Frequency : 433.92 MHz Max. Power : 62.11 dBμV/m@3m (Test result) Max. EIRP : -33.15 dBm/0.00484(mW) (Calculate result) Max. ERP : -35.3 dBm/0.00295 (mW) (Calculate result) Conducted Power : -10.8 dBm/0.0832(mW) (Calculate result) Type of Modulation : FSK TX. Antenna Gain : Max peak gain -24.5 dbi Antenna Type : Internal PCB loop antenna Note: EIRP(W)=(E1*d) 2 /30 EIRP(dBm)=10log 10 (EIRP(W))+30=E2+20log(d)-104.8 Conducted Power= Max. EIRP- Antenna Gain E1: Electric field strength in V/m E2: Electric field strength in dBμV/m d: measurement distance in m 1.2. Assess laboratory Tianjin Dongdian Testing Service Co., Ltd. Address: Building D-1, No. 19, Weisi Road, Microelectronics Industrial Park Development Area, Tianjin, China., 300385 Tel: +86-22-58038033, http://www.ddttest.com, Email: [email protected] NVLAP (National Voluntary Laboratory Accreditation Program) CODE: 500036-0 CNAS (China National Accreditation Service for Conformity Assessment) CODE: L13402 FCC Designation Number: CN5004; FCC Test Firm Registration Number: 368676 ISED (Innovation, Science and Economic Development Canada) Company Number: 27768 Conformity Assessment Body Identifier: CN0125 VCCI Facility Registration Number: C-20089, T-20093, R-20125, G-20122 Tianjin Dongdian Testing ServiceCo.,Ltd. Report No.: DDT-B24011002-2E02 Page 6 of 6 2.RF Exposure Evaluation 2.1. Requirement Per § 1.1307(b)(3)(i)(A), a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption. 2.2. Estimation result Mode Band EIRP Tune-up (dBm) EIRP Tune-up (mW) Conducted Power (dBm) Conducted Power (mW) Transmitter Emissions 433.92MHz -320.000631 -10…

Text truncated - open the document above for the full version.

Test Report

1 SPECIFICATION APPLICATION FOR APPROVAL PART NAME : 433 PCB ANTENNA DATE : 2024/1/20 Release : Full release Customer Approval Program Manager R & D director Peter Lu Peter Lu Supplier Approval Program Manager R & D director 郝井强(Jingqiang Hao) 孙高鹤(Gaohe Sun) Company:Tianjin Yingshun Communication Technology Co., Ltd Address: Room 805, Building 2, Fubao Industrial Park, Zhangjiawo Town, Xiqing District, Tianjin Confidential This message contains information that may be confidential and privileged. Unless you are the addressee (or authorized to receive messages for the addressee), you can not use, copy or disclose to any third party or any information contained in the message. If you have received the message in error, please advise the sender by reply e-mail and delete the message. Nothing in this message should be interpreted as a digital or electronic signature that can be used to authenticate a contract or other legal document. Thank you very much. 2 REVISION REV.NO. DATE DESCRIPTION 0 2024/1/20 APPROVAL 3 1. ELECTRICAL SPECIFICATIONS 1-1 FREQUENCY BAND Freq. Band Freq.(MHz) 433 433-434MHz 1-2 IMPEDANCE Nominal Impedance(including matching circuit) : 50 ohms 1-3 MATCHING REQUIREMENTS The matching circuit on the PCB of the handset is according to Figure 1-3. Optimum matching circuit is highly dependent on the handset and thus. Final matching circuit layout and values will be defined when handset is available Figure 1-3 4 3.ENVIRONMENTAL CHARACTERISTICS NO. ITEM TEST CONDITION 1 Normal condition 1.Temperature: 24.3±1°C 2. Humidity: 35%±2% 3. Pressure: 101.2KPa 4. Test equipment Equipment Model No Manufactory Series No ENA vector analyzer E5071C Keysight MY46900684 OTA chamber FT-0024 FEITU FS20200302 5. PACKAGING Antenna is PCB type , packaging with PCB board. 6. APPENDIX All of the specifications are shown as the attached files. Customer No: Sensata Technologies (Changzhou) Co., Ltd. File: 2024/01/20 Test Condition: FREE SPACE Note: VSWR/ReturnLoss/Smith Chart Confirmation: Jing Qiang Hao Engineer: GaoHe Sun 5 Figure 2-1 0.5mm 10.44mm 22.00mm 6 Antenna Test Date 一:Antenna Efficiency&PeakGain Frequency ID 1 2 Frequency (MHz) 433.0 434.0 Efficiency (dBi) -36.45-36.45 Gain (dBi) -24.33-24.50 Efficiency (%) 0.02 0.02 Directivity (dB) 12.12 12.06 Peak Gain Position (Theta) 165.00 165.00 Peak Gain Position (Phi) 120.00 120.00 Efficiency ThetaPol (%) 0.01 0.01 Efficiency PhiPol (%) 0.01 0.01 Upper Hem. Efficiency (%) 0.00 0.00 Lower Hem. Efficiency (%) 0.02 0.02 二:Antenna 2D-XZ/YZ/XY 9 三:Antenna 3D(433-434MHz)

Test Setup Photos

Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Appendix : Test Setup Photograph Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E Tianjin Dongdian Testing Service Co., Ltd. Report No.: DDT-B24011002-2E

Contact Information

Applicant

Peter Lu(Manager)
[email protected]+86-18861139066Fax: +86-18861139066

Test Firm

Tianjin Dongdian Testing Service Co.,Ltd.Kevin Feng
[email protected]+86-22-23961234

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Sensata Technologies (Changzhou) Co., Ltd.

2BAW4-CZBG6FD4

TPMS Sensor

Aug 07, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2BAW4-NHSS4

TPMS Sensor

Apr 01, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor - FCC ID 2BAW4-AG5PF3 - Sensata Technologies (Changzhou) Co., Ltd.
2BAW4-AG5PF3

TPMS Sensor

May 07, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter