FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Emlid Tech Kft./
  3. 2BAYEWL1

2BAYEWL1Dual-band radio module

Emlid Tech Kft.

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Sep 29, 2025
Application Purpose
Original Equipment
Equipment Note
Dual-band radio module
Frequency Range
410.12500000 - 469.12500000
Company
Emlid Tech Kft.
Country
Hungary

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FCC COVERED LIST DECLARATION LETTER Page 1 of 1 Revision 1.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Emlid Tech Kft. Address Esztergomi way 31-39, HUB 3 building, 5 floor Budapest Hungary 1138 FRN 0033690983 Grantee Code 2BAYE FCC ID: 2BAYEWL1 Authorized Contact Name Happy fei Contact Phone +36204199518 Contact Email [email protected] We certifies: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant [is not] identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. - the software to be loaded prior to marketing of the equipment identified above is not “covered” software manufactured by any entity including predecessors, successors, parents, subsidiaries, affiliates or any entity which has rebranded or relabeled the software produced by the entity(ies) identified on the “Covered List”. - the device is not capable of storing or running software listed on the covered list and therefore is inherently compliant. NOTE: Justification/evidence explaining how compliance is met must accompany this letter Link to the Covered List: Covered List Applicant Signature: Date: 2025/06/30 Print Name: Happy fei Title: Quality Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.4 April 25, 2025 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Emlid Tech Kft. Address Esztergomi way 31-39, HUB 3 building, 5 floor Budapest Hungary 1138 FRN 0033690983 Grantee Code 2BAYE FCC ID: 2BAYEWL1 Authorized Contact Name Happy fei Contact Phone +36204199518 Contact Email [email protected] I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc. terms and conditions as specified in the TCB Application Form 731 (QSF27-14-01). Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Applicant Signature: Date: 2025/06/30 Print Name: Happy fei Title: Quality Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

UNITED STATES DESIGNATED AGENT LETTER Date: 2025/06/30 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: Emlid Tech Kft. Company Name: NexGroup Inc. FRN: 0033690983 FRN: 0033876012 Grantee Code: 2BAYE Contact Name: Happy fei Contact Name Happy Fei Address: Esztergomi way 31-39, HUB 3 building, 5 floor Budapest Hungary 1138 Address: 100 TradeCenter Suite G-700, Woburn, MA USA 01801 City/Province/Zip: Budapest Hungary 1138 City/Province/Zip: Woburn, MA USA 01801 Telephone: +36204199518 Telephone: / Fax: / Fax: / Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: 2BAYEWL1 ATTN: Director of Certification: We, < Emlid Tech Kft. > and < U.S. agent > understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e-mail of the designated agent listed above. We, < Emlid Tech Kft. > and < U.S. agent > acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Applicant U.S. designated agent Name (Printed): Happy fei Name (Printed): Happy fei Title: Quality Manager Title: Quality Manager Signature: Signature:

Attestation Statements

Emlid Tech Kft. To: Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd. Columbia MD 21046 From: Emlid Tech Kft. Esztergomi way 31-39, HUB 3 building, 5 floor, 1138 Budapest, Hungary Dear Sir/Madam, We, Emlid Tech Kft. hereby declare that our product: Dual-band radio module, FCC ID: 2BAYEWL1 Acknowledge that this device is for use in part 90, additionally, Federal end users are intended per Part 2.103(a). the frequency bands are:410.125MHz-469.125MHz. Part 2.106 has been used to construct the following table of frequency range capability intended for end users. Acknowledge that operation on unauthorized frequencies is a violation of FCC rules. Acknowledge the inclusion of Grant note code “EF”. Frequency (MHz) Part 90 Part 80 Part 74 Part 22 Federal 400.0000-406.0000 √ 406.1000-420.0000 √ √ 420.0000-450.0000 √ √ 450.0000-454.0000 √ √ 454.0000-455.0000 √ √ 455.0000-456.0000 √ 456.0000-460.0000 √ √ √ 460.0000-462.5375 √ √ 462.5375-462.7375 √ 462.7375-467.5375 √ √ √ 467.5375-467.7375 √ √ 467.7375-470.0000 √ √ √ Sincerely yours, Print Name: Happy fei Title: Quality Manager Signature: On behalf of Company: Emlid Tech Kft. Telephone: +36204199518 E-mail: [email protected]

Cover Letter(s)

Emlid Tech Kft. Date: 2025/06/30 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2BAYEWL1 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Emlid Tech Kft. This authorization is valid until further written notice from the applicant. Print Name: Happy fei Title: Quality Manager Signature: On behalf of Company: Emlid Tech Kft. Telephone: +36204199518 E-mail: [email protected]

Cover Letter(s)

Emlid Tech Kft. Date: 2025/06/30 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request regarding application for FCC ID: 2BAYEWL1 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune up The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within aforementioned days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Print Name: Happy fei Title: Quality Manager Signature: On behalf of Company: Emlid Tech Kft. Telephone: +36204199518 E-mail: [email protected]

Cover Letter(s)

Emlid Tech Kft. Cover Letter-Modular Approval FCC ID: 2BAYEWL1 Date: 2025/09/15 Gentlemen: There’s an Module that would like to have your authorization as a modular approval. The specific product as below, Module with its designed features and specified description, meets special requirements for Full modular approval on FCC KDB996369 by cross-reference list below. Company Emlid Tech Kft. Model Name Dual-band radio module Model Number WL1 FCC ID 2BAYEWL1 Requirement of FCC KDB996369 Comply(Y/N) 1. The modular transmitter must have its own RF shielding. Y The EUT provides the RF shielding. See EUT photo. 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. Y The EUT has its buffered modulation. Please see the Schematic Diagram. 3. The modular transmitter must have its own power supply regulation. Y The EUT has its own power supply regulation, please see the Schematic Diagram. 4. The modular transmitter must comply with the antenna and transmission system requirements of Sections 15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The “professional installation” provision of Section 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. Y The EUT meets the FCC antenna requirements. 5. The modular transmitter must be tested in a stand -alone configuration, i.e., the module must not be inside another device during testing. Y The EUT was tested with a test board, Please see test report and setup photo 6. The modular transmitter must be labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior Y Please see exhibition label sample for the FCC ID of this module. And also in the exhibition Users manual, there are instructions give to the OEM on how to label the end product. label can use wording such as the following: “Contains Transmitter Module FCC ID” or “Contains FCC ID” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. 7. The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Y The EUT is compliant with all applicable FCC rules. Details instructions for maintaining compliance are give in the User Manual. 8. The modular transmitter must comply with any applicable RF exposure requirements. For example, FCC Rules in Sections 2.1091, 2.1093 and specific sections of Part 15, including 15.319(i), 15.407(f), 15.253(f) and 15.255(g), require that Unlicensed PCS, UNII and millimeter wave devices perform routine environmental evaluation for RF Exposure to demonstrate compliance. In ad dition, spread spectrum transmitters operating under Section 15.247 are required to address RF Exposure compliance in accordance with Section 15.247(b)(4). Y The EUT complies with RF exposure requirement. Thank you. Sincerely, Print Name: Happy fei Title: Quality Manager Signature: On behalf of Company: Emlid Tech Kft. Telephone: +36204199518 E-mail: [email protected]

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252604 Page: 1 of 8 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Evaluation Report Application No.: SZCR2506002526AT Applicant: Emlid Tech Kft. Address of Applicant: Esztergomi way 31-39, HUB 3 building, 5 floor, 1138 Budapest, Hungary Manufacturer: NexPCB Limited Address of Manufacturer: Room 605A,TCL Industrial Centre, 8 Tai Chung Road, Tsuen Wan,Hong Kong Factory: Ningbo High-tech Zone Ladder Science co., Ltd Address of Factory: No. 4-1, 5-1, 6-1, Building 3, No. 3, Lane 215, Qingyi Road, Ningbo High-tech Zone, Zhejiang Province Equipment Under Test (EUT): Product Name: Dual-band radio module Model No.: WL1 Trade mark: EMLID FCC ID: 2BAYEWL1 Standards: 47 CFR Part 1.1307 47 CFR Part 1.1310 Date of Receipt: 2025-06-13 Date of Test: 2025-06-17 to 2025-08-29 Date of Issue: 2025-08-29 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252604 Page: 2 of 8 Revision Record Version Chapter Date Modifier Remark 01 2025-08-29 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252604 Page: 3 of 8 2 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 CONTENTS .................................................................................................................................................. 3 3 GENERAL INFORMATION .......................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF EUT ................................................................................................................. 4 3.2 TEST LOCATION .......................................................................................................................................... 5 3.3 TEST FACILITY ............................................................................................................................................ 5 3.4 DEVIATION FROM STANDARDS ..................................................................................................................... 6 3.5 ABNORMALITIES FROM STANDARD CONDITIONS ............................................................................................ 6 3.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................................................................. 6 4 RF EXPOSURE EVALUATION .................................................................................................................... 7 4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 7 4.1.1 Limits ................................................................................................................................................ 7 4.1.2 Test Procedure ................................................................................................................................ 7 4.1.3 EUT RF Exposure Evaluation .......................................................................................................... 8 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252604 Page: 4 of 8 3 General Information 3.1 General Description of EUT Power supply: DC 5V,2.1A For Lora Operation Frequency: 902.9MHz to 927.5MHz Modulation Type: CSS Number of Channels: 42 Channels Channel Spacing: 500KHz Antenna Type: Terminal Antenna Antenna Gain: 2.5dBi For UHF Frequency Range: 410.125MHz-469.125MHz Modulation Type: GMSK Channel separation: 12.5KHz/25KHz Rate output Power: 500mW/1000mW/2000mW Antenna Type: Monopole Antenna Antenna Gain: 2.94dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252604 Page: 5 of 8 3.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China. 518057. Tel: +86 755 2601 2053 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • CNAS (No. CNAS L2929) CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the competence in the field of testing. • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recogn…

Text truncated - open the document above for the full version.

Test Report

TM VeeLink Telecommunication Co., Ltd. New Light Source Industrial Base in Shishan Town, Nanhai District, Foshan City, Guangdong Province, China. Note: Specifications subject to technical changes and tests. -www.veelinktelecom.com VL900ES TerminalAntenna\862-928MHz ElectricalSpecifications:MechanicalSpecifications: Frequencyband862-928MHzRF connectorinterfaceRPSMAmale Band width66MHz PolarizationVertical Gain 2±0.5dBi VSWR≤2.5 Max. input power20watts Inputimpedance50 Ω Antennatyp eMonopole EnvironmentalSpecifications:Dimension& weight: OperatingTempt.-40 °C to + 60 °CAntennaheightp16x 180mm RatedWind Velocity60m/sNet weight30g RelativeHumidityUp to 80%Shippingpackage500units/carton Packeddimensions40*30*20cm Shippingweight15.5kg Radiationpatterns:Outlinedrawing:

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 1 of 79 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2506002526AT Applicant: Emlid Tech Kft. Address of Applicant: Esztergomi way 31-39, HUB 3 building, 5 floor, 1138 Budapest, Hungary Manufacturer: NexPCB Limited Address of Manufacturer: Room 605A,TCL Industrial Centre, 8 Tai Chung Road, Tsuen Wan,Hong Kong Factory: Ningbo High-tech Zone Ladder Science co., Ltd Address of Factory: No. 4-1, 5-1, 6-1, Building 3, No. 3, Lane 215, Qingyi Road, Ningbo High- tech Zone, Zhejiang Province,China Equipment Under Test (EUT): EUT Name: Dual-band radio module Model No.: WL1 Trade mark: EMLID FCC ID: 2BAYEWL1 Standard(s) : 47 CFR Part 22, 47 CFR Part 74, 47 CFR Part 80, 47 CFR Part 90, Date of Receipt: 2025-06-13 Date of Test: 2025-06-17 to 2025-09-12 Date of Issue: 2025-09-12 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 2 of 79 Revision Record Version Chapter Date Modifier Remark 01 2025-09-12 Original Authorized for issue by: Edison Li /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 3 of 79 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 22, Part 74, Part 80, Part 90 N/A 47 CFR Part 22.365, 47 CFR Part 74.30, 47 CFR Part 80.3(e), 47 CFR Part 90.205(g,h), Pass Radio Spectrum Matter Part Item Standard Method Requirement Result RF Power Output 47 CFR FCC Part 2, Part22, Part74, Part80, Part90 ANSI/TIA-603- E:2016 ANSI C63.4.2014 TIA-102 CCAA-A TIA-102 CCAB-D TIA-102 CCAA-D ANSI C63.26-2015 47 CFR FCC Part 2.1046, Part22.565, Part74.461, Part80.215, Part90.205 Pass Frequency Stability 47 CFR FCC Part 2, Part22, Part74, Part80, Part90 47 CFR FCC Part 2.1055, Part22.355, Part74.464, Part80.209, Part90.213 Pass Audio Frequency Response 47 CFR FCC Part 2, Part74, Part80, Part90, 47 CFR FCC Part2.1047, Part74.463, Part80.213, Part90.212, N/A Modulation Limiting 47 CFR FCC Part 2, Part74, Part80, Part90, 47 CFR FCC Part2.1047, Part74.463, Part80.213, Part90.212, N/A Occupied Bandwidth 47 CFR FCC Part 2, Part22, Part74, Part80, Part90 47 CFR FCC Part 2.1049, Part22.359, Part74.462, Part80.211(e,f), Part90.210 Pass Transient Frequency Behaviour 47 FCC CFR Part90 47 CFR FCC Part90.214 Pass Conducted Spurious Emission 47 CFR FCC Part 2, Part22, Part74, Part80, Part90 47 CFR FCC Part 2.1051, Part22.359, Part74.462(c), Part80.211(c), Part90.210 Pass Radiated Spurious Emission 47 CFR FCC Part 2, Part22, Part74, Part80, Part90 47 CFR FCC Part 2.1051, Part22.359, Part74.462(c), Part80.211(c), Part90.210 Pass N/A: Not Applicable. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 4 of 79 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 8 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 8 4.4 TEST LOCATION .................................................................................................................................... 9 4.5 TEST FACILITY ...................................................................................................................................... 9 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 9 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 9 5 EQUIPMENT LIST .................................................................................................................................... 10 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 12 6.1 ANTENNA REQUIREMENT .................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 14 7.1 RF POWER OUTPUT ........................................................................................................................... 14 7.1.1 E.U.T. Operation .......................................................................................................................... 19 7.1.2 Test Setup Diagram ..................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 59 of 79 12.5KHz, GMSK mode, Assigned Frequency: 410.125MHz, Rated power: 1000mW 12.5KHz, GMSK mode, Assigned Frequency: 450.125MHz, Rated power: 1000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 60 of 79 12.5KHz, GMSK mode, Assigned Frequency: 456.125MHz, Rated power: 1000mW 12.5KHz, GMSK mode, Assigned Frequency: 469.125MHz, Rated power: 1000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 61 of 79 12.5KHz, GMSK mode, Assigned Frequency: 410.125MHz, Rated power: 2000mW 12.5KHz, GMSK mode, Assigned Frequency: 450.125MHz, Rated power: 2000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 62 of 79 12.5KHz, GMSK mode, Assigned Frequency: 456.125MHz, Rated power: 2000mW 12.5KHz, GMSK mode, Assigned Frequency: 469.125MHz, Rated power: 2000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 63 of 79 4.Emission Mask 25KHz, GMSK mode, Assigned Frequency: 410.125MHz, Rated power: 500mW 25KHz, GMSK mode, Assigned Frequency: 450.125MHz, Rated power: 500mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 64 of 79 25KHz, GMSK mode, Assigned Frequency: 456.125MHz, Rated power: 500mW 25KHz, GMSK mode, Assigned Frequency: 469.125MHz, Rated power: 500mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 65 of 79 25KHz, GMSK mode, Assigned Frequency: 410.125MHz, Rated power: 1000mW 25KHz, GMSK mode, Assigned Frequency: 450.125MHz, Rated power: 1000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 66 of 79 25KHz, GMSK mode, Assigned Frequency: 456.125MHz, Rated power: 1000mW 25KHz, GMSK mode, Assigned Frequency: 469.125MHz, Rated power: 1000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 67 of 79 25KHz, GMSK mode, Assigned Frequency: 410.125MHz, Rated power: 2000mW 25KHz, GMSK mode, Assigned Frequency: 450.125MHz, Rated power: 2000mW SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/1 Report No.: SZCR250600252603 Page: 68 of 79 25KHz, GMSK mode, Assigned Frequency: 456.125MHz, Rated power: 2000mW 25KHz, GMSK mode, Assigned Frequency: 469.125MHz, Rated power: 2000mW SGS-CSTC Standards Technical Serv…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Happy fei
[email protected]Fax: /

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122,74,8410.125 MHz - 469.125 MHz514.60 mW9K69F3E5ppm
222,74,8410.125 MHz - 469.125 MHz1.1649 W9K70F3E5ppm
322,74,8410.125 MHz - 469.125 MHz2.2356 W9K74F3E5ppm
422,74,80,9410.125 MHz - 469.125 MHz505.80 mW4K76F3E5ppm
522,74,80,9410.125 MHz - 469.125 MHz1.1692 W4K77F3E5ppm
622,74,80,9410.125 MHz - 469.125 MHz2.0526 W4K76F3E5ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. Single Modular Approval. The antenna used for this transmitter must be installed to provide a separation distance of at least 50cm from all persons and must not be co-located or operating in configuration with any other antenna or transmitter. End-users must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.