FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RUNHOOD POWER INC./
  3. 2BB59-F2400-US

2BB59-F2400-USRESIDENTIAL ESS & PORTABLE POWER STATION

RUNHOOD POWER INC.
RESIDENTIAL ESS & PORTABLE POWER STATION - FCC ID 2BB59-F2400-US - RUNHOOD POWER INC.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 14, 2024
Application Purpose
Original Equipment
Date of Application
Aug 14, 2024
Equipment Note
RESIDENTIAL ESS & PORTABLE POWER STATION
Frequency Range
2412.00000000 - 2462.00000000
Company
RUNHOOD POWER INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

RUNHOODPOWERINC. 2.911(d)(5)(i)EquipmentTypeAttestationv1.2 Section2.911(d)(5)(i)Certification–EquipmentType Companyname:RUNHOODPOWERINC. Address:3980-DValleyBlvd,Walnut,California91789UnitedStates ProductName:RESIDENTIALESS&PORTABLEPOWERSTATION FCCID:2BB59-F2400-US Model(s):F2400-US 2.911(d)(5)(i)EquipmentType We,[RUNHOODPOWERINC.]certifythattheequipmentforwhichauthorizationissoughtthrough certificationisnot:  Prohibitedfromreceivinganequipmentauthorizationpursuantto§2.903;oftheFCCrules.  Identifiedasanequipmenttypeinthe“CoveredList” NOTE1 Yourssincerely, Signature: Name:QinWeiDate:2024.8.5 TitleandCompanyname:DeputygeneralmanagerofR&D / RUNHOODPOWERINC. NOTE1 “CoveredList”;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

RUNHOODPOWERINC. 2.911(d)(5)(ii)ApplicantAttestationv1.2 Section2.911(d)(5)(ii)Certification–Applicant(CoveredList) Companyname: RUNHOODPOWERINC. Address:3980-DValleyBlvd,Walnut,California91789UnitedStates ProductName: RESIDENTIALESS&PORTABLEPOWERSTATION FCCID:2BB59-F2400-US Model(s): F2400-US 2.911(d)(5)(ii)Applicantfiling We,[ RUNHOODPOWERINC. ]certifythat,asofthedateofthefilingoftheapplication,theapplicantis notidentified NOTE1 onthe“CoveredList” NOTE2 ,establishedpursuantto §1.50002ofthischapter,asanentityproducingcoveredcommunicationsequipment. Yourssincerely, Signature: Name:QinWeiDate:2024.8.5 TitleandCompanyname:DeputygeneralmanagerofR&D/RUNHOODPOWERINC. NOTE1 Deleteoptionnotapplicabletothisapplication. NOTE2 “CoveredList ” ;istheListofEquipmentandServicesCoveredBySection2ofTheSecureNetworksAct,availableat https://www.fcc.gov/supplychain/coveredlist References; 1)986446D01CoveredEquipmentv01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2)FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

RUNHOODPOWERINC. 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname: RUNHOODPOWERINC. Address:3980-DValleyBlvd,Walnut,California91789UnitedStates ProductName:RESIDENTIALESS&PORTABLEPOWERSTATION FCCID:2BB59-F2400-US Model(s):F2400-US 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ RUNHOODPOWERINC. ]designate[ RUNHOODPOWERINC. ] NOTE1 forthe purposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. RUNHOODPOWERINC. 2.911(d)(7)USAAgentv1.5 USAAgent Companyname: RUNHOODPOWERINC. USAAddress:3980-DValley Blvd,Walnut,California91789UnitedStates FRNNumber:0034026419 ContactName:[email protected] TelephoneNo:+86-021-57766651 Email:[email protected] Applicant Companyname: RUNHOODPOWERINC. Address:3980-DValley Blvd,Walnut,California91789UnitedStates GranteeFRNNumber:0034026419 FCCGranteeCode:2BB59 ContactName:QinWei TelephoneNo:+86-021-57766651 Email:[email protected] Signature: Title:DeputygeneralmanagerofR&D Signature: Title:DeputygeneralmanagerofR&D Date:2024.8.5Date:2024.8.5 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

RUNHOODPOWERINC. AgentAuthorization Company:RUNHOODPOWERINC. Address:3980-DValleyBlvd,Walnut,California91789UnitedStates ModelNumber(s): F2400-US ProductDescription:RESIDENTIALESS&PORTABLEPOWERSTATION WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature: Date:2024.8.5 Name: QinWei Title: DeputygeneralmanagerofR&D Company: RUNHOODPOWERINC.

Cover Letter(s)

RUNHOODPOWERINC. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024.8.5 Subject;RequestforConfidentiality FCCID:2BB59-F2400-US ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:QinWei Title:DeputygeneralmanagerofR&D

External Photos

FCCID:2BB59-F2400-US External

ID Label/Location Info

Label size:210*100mm Label location:

Internal Photos

FCCID:2BB59-F2400-US Internal

RF Exposure Info

KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]: www.gdksign.com RFEXPOSUREEVALUATION 1.PRODUCTINFORMATION ProductDescriptionRESIDENTIALESS&PORTABLEPOWERSTATION ModelNameF2400-US FCCID2BB59-F2400-US 2.EVALUATIONMETHODANDLIMIT HumanexposuretoRFemissionsfrommobiledevices(47CFR§2.1091)maybeevaluated basedontheMPElimitsadoptedbytheFCCforelectricandmagneticfieldstrengthand/or powerdensity,asappropriate,sinceexposuresareassumedtooccuratdistancesof20cmor morefrompersons. §1.1310(e)(1)LIMITSFORGENERALPOPULATION/UNCONTROLLEDEXPOSURE Frequency Range (MHz) E-fieldStrength (E) (V/m) MagneticField Strength(H) (A/m) PowerDensity (S) (mW/cm 2 ) AveragingTime |E| 2 ,|H| 2 orS (Minutes) 0.3--1.346141.63(100)*30 1.34--30824/f2.19/f(180/f 2 )*30 30--30027.50.0730.230 300--1500----f/150030 1500--100,000----1.030 *Note: 1.f=FrequencyinMHz *=Plane-waveEquivalentPowerDensity 2.TheMPElimitforGeneralPopulation/Uncontrolledexposuretofixedtransmittersisnot applicableforportabletransmitters.Portabledevicesevaluationshallbeperformedaccording totheSARprovisionsin47CFR§2.1093. S=PG/4πR² Where: S=powerdensity(inappropriateunits,e.g.mw/cm 2 ) P=powerinputtoantenna(inappropriateunits,e.g.,mW) G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna(inappropriateunits,e.g.,cm) KSIGN(Guangdong)TestingCo.,Ltd. WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark, Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong,People’sRepublicofChina Tel.:+(86)755-29852678Fax:+(86)755-29852397E-mail:[email protected]: www.gdksign.com 3.CALCULATION Aminimumtestseparationdistance≥20cmisrequiredbetweentheantennaandradiating structuresofthedeviceandnearbypersonstoapplymobiledeviceexposurelimits.The distancemustbeatleast20cmandfullysupportedbytheoperatingandinstallation configurationsofthetransmitteranditsantenna(s),accordingtothesource-based time-averagedmaximumpowerrequirementsof§2.1091(d)(2).Incaseswherecablelosses orotherattenuationsareappliedtodeterminecompliance,themostconservativeoperating configurationsandexposureconditionsmustbeevaluated. WIFIPART(Cannottransmitatdifferentbandsimultaneously) AntennaGain=3.96dBi(Numeric2.49),π=3.14 802.11BSinglemode(Worstcase)For2.4GHzWIFI BLE(Worstcase2440MHz) AntennaGain=3.96dBi(Numeric2.49),π=3.14 Note: 1.Antennagainprovidedbytheapplicant.Canaffectthevalidityofresults. 2.Onlytheworstcaserecorded. 3.TheWIFIandBLEcantransmitsimultaneouslyand MPEratio(BLE+2.4GWIFI)=0.0001+0.01396=0.01406<1 itsatisfytheRFexposurerequirementsforsimultaneoustransmissionthatthesumofthe MPEradios<1 Result:Compliant --THEEND-- FrequencyOutputPowerOutputPowerPowerDensityPowerDensityLimit MHzdBmmWmW/cm2mW/cm2 241214.5028.18 0.01396 1 FrequencyOutputPowerOutputPowerPowerDensityPowerDensityLimit MHzdBmmWmW/cm2mW/cm2 2440-6.550.220.00011

Test Report

OTA TEST REPORT TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in ANSI/IEEE Std 149-2008. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Prepared by: Peng Tao Approved by: Kai Xu TA Technology (Shanghai) Co., Ltd. No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China TEL: +86‐021‐50791141/2/3 FAX: +86‐021‐50791141/2/3‐8000 Applicant Espressif System (Shanghai) Co.,Ltd Product ESP32-C3-MINI-1 Model ESP-ANT D-H Report No. Y2102A0260-T2 Issue Date March 9, 2021 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 2 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. TABLE OF CONTENTS 1. Test Laboratory .............................................................................................................................. 3 1.1. Notes of the Test Report ................................................................................................... 3 1.2. Test facility ........................................................................................................................ 3 1.3. Testing Location ................................................................................................................ 3 1.4. Laboratory Environment .................................................................................................... 4 2. General Description of Equipment under Test ............................................................................... 5 2.1. Applicant and Manufacturer Information ............................................................................ 5 2.2. General information ........................................................................................................... 5 2.3. Test Date ........................................................................................................................... 5 2.4. Receiving Date .................................................................................................................. 5 2.5. Applied Standards ............................................................................................................. 6 3. Test Conditions .............................................................................................................................. 7 3.1. Test Configuration ............................................................................................................. 7 3.2. Test Measurement ............................................................................................................. 7 4. Test Results ................................................................................................................................... 8 4.1. Gain and Efficiency ............................................................................................................ 8 5. Equipment List ............................................................................................................................... 9 ANNEX A 3-D Pattern Plots ................................................................................................................... 10 ANNEX B:The EUT Appearance and Test Configuration ...................................................................... 12 B.1 EUT Appearance ................................................................................................................... 12 B.2 Test Configuration ................................................................................................................. 13 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 3 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1. Test Laboratory 1.1. Notes of the Test Report This report shall not be reproduced in full or partial, without the written approval of TA technology (shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein .Measurement Uncertainties were not taken into account and are published for informational purposes only. This report is written to support regulatory compliance of the applicable standards stated above. 1.2. Test facility A2LA (Certificate Number: 3857.01) TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform measurement. 1.3. Testing Location Company: TA Technology (Shanghai) Co., Ltd. Address: No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China City: Shanghai Post code: 201201 Country: P. R. China Contact: Xu Kai Telephone: +86-021-50791141/2/3 Fax: +86-021-50791141/2/3-8000 Website: http://www.ta-shanghai.com E-mail: [email protected] OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 4 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 1.4. Laboratory Environment Temperature Min. =19°C,Max. = 25°C Relative humidity Min. =40%,Max. =72% Shield effect 0.7-6GHz > 100dB Ground resistance <0.5 OTA Test Report Report No: Y2102A0260-T2 TA Technology (Shanghai) Co., Ltd. TA-MB-04-008O P age 5 of 13 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd. 2. General Description of Equipment under Test 2.1. Applicant and Manufacturer Information Applicant Name Espressif System (Shanghai) Co.,Ltd Applicant address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China Manufacturer Name Espressif System (Shanghai) Co.,Ltd Manufacturer address Suite 204 Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China 2.2. …

Text truncated - open the document above for the full version.

Test Report

Page 1 of 80Report No.: KS2404S1505E01 TRF No. RF_R1 Add:West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu, Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, China Tel: +(86) 0755-2985 2678Fax: +(86) 0755-2985 2397E-mail: [email protected]: www.gdksign.com TEST REPORT Report No................................:KS2404S1505E01 FCC ID.....................................:2BB59-F2400-US Applicant..................................:RUNHOOD POWER INC. Address....................................:3980-D Valley Blvd,Walnut,California 91789 United States Manufacturer ........................... :Shanghai Runhood Smart Energy Co., Ltd. Address....................................: Room 401, 4F, Building 5, No.218 Mingnan Road, Songjiang District, Shanghai, China Product Name ......................... :RESIDENTIAL ESS & PORTABLE POWER STATION Model/Type reference............:F2400-US Standard..................................:47 CFR Part 15.247 Date of Receipt.......................:April 24, 2024 Date of Test Date....................:April 24, 2024 to August 5, 2024 Date of issue ........................... :August 5, 2024 Test result ............................... :Pass Conclusion...............................:The submitted sample was found to COMPLY with the standards above. Prepared by: ( Printed name + Signature) Chad Lin Approved by: ( Printed name + Signature) Sky Dong Testing Laboratory Name ... :KSIGN(Guangdong) Testing Co., Ltd. Address....................................: West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu, Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, China Page 2 of 80Report No.: KS2404S1505E01 TRF No. RF_R1 Add:West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu, Shatou, Shajing, Bao'an District, Shenzhen, Guangdong, China Tel: +(86) 0755-2985 2678Fax: +(86) 0755-2985 2397E-mail: [email protected]: www.gdksign.com TABLE OF CONTENTSPage 1. TEST SUMMARY.............................................................................................................................................3 1.1. Test Standards....................................................................................................................................... 3 1.2. Report Version....................................................................................................................................... 3 1.3. Test Description......................................................................................................................................4 1.4. Test Facility.............................................................................................................................................5 1.5. Measurement Uncertainty......................................................................................................................5 2. GENERAL INFORMATION..............................................................................................................................6 2.1. General Description Of EUT.................................................................................................................. 6 2.2. Accessory Equipment Information......................................................................................................... 6 2.3. Description of Test Modes......................................................................................................................6 2.4. Operation channel list............................................................................................................................ 7 2.5. Measurement Instruments List...............................................................................................................8 3. Evaluation Results (Evaluation)..................................................................................................................10 3.1. Antenna requirement............................................................................................................................10 4. Radio Spectrum Matter Test Results (RF)..................................................................................................10 4.1. Conducted Emission at AC power line.................................................................................................10 4.2. Occupied Bandwidth............................................................................................................................14 4.3. Maximum Conducted Output Power....................................................................................................15 4.4. Power Spectral Density........................................................................................................................16 4.5. Emissions in non-restricted frequency bands......................................................................................17 4.6. Band edge emissions (Radiated).........................................................................................................18 4.7. Emissions in frequency bands (below 1GHz)......................................................................................23 4.8. Emissions in frequency bands (above 1GHz)......................................................................................26 5. EUT TEST PHOTOS...................................................................................................................................... 33 6. PHOTOGRAPHS OF EUT CONSTRUCTIONAL..........................................................................................35 Appendix............................................................................................................................................................36 6.1. Appendix A: DTS Bandwidth.................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page1of61ReportNo.:KS2404S1505E02 TRFNo.RF_R1 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com TESTREPORT ReportNo................................:KS2404S1505E02 FCCID.....................................:2BB59-F2400-US Applicant..................................:RUNHOODPOWERINC. Address....................................:3980-DValleyBlvd,Walnut,California91789UnitedStates Manufacturer ........................... :ShanghaiRunhoodSmartEnergyCo.,Ltd. Address....................................: Room401,4F,Building5,No.218MingnanRoad,SongjiangDistrict, Shanghai,China ProductName ......................... :RESIDENTIALESS&PORTABLEPOWERSTATION Model/Typereference............:F2400-US Standard..................................:47CFRPart15.247 DateofReceipt.......................:April24,2024 DateofTestDate....................:April24,2024toAugust5,2024 Dateofissue ........................... :August5,2024 Testresult ............................... :Pass Conclusion...............................:ThesubmittedsamplewasfoundtoCOMPLYwiththestandardsabove. Preparedby: (Printedname+Signature) ChadLin Approvedby: (Printedname+Signature) SkyDong TestingLaboratoryName ... :KSIGN(Guangdong)TestingCo.,Ltd. Address....................................: WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrial Park,Minzhu,Shatou,Shajing,Bao'anDistrict,Shenzhen,Guangdong, China Page2of61ReportNo.:KS2404S1505E02 TRFNo.RF_R1 Add:WestSideof1/F.,BuildingC,ZoneA,FuyuanNewFactory,JiujiuIndustrialPark,Minzhu,Shatou, Shajing,Bao'anDistrict,Shenzhen,Guangdong,China Tel:+(86)0755-29852678Fax:+(86)0755-29852397E-mail:[email protected]:www.gdksign.com TABLEOFCONTENTSPage 1.TESTSUMMARY.............................................................................................................................................3 1.1.TestStandards.......................................................................................................................................3 1.2.ReportVersion.......................................................................................................................................3 1.3.TestDescription......................................................................................................................................4 1.4.TestFacility.............................................................................................................................................5 1.5.MeasurementUncertainty......................................................................................................................5 2.GENERALINFORMATION..............................................................................................................................6 2.1.GeneralDescriptionOfEUT..................................................................................................................6 2.2.AccessoryEquipmentInformation.........................................................................................................6 2.3.DescriptionofTestModes......................................................................................................................6 2.4.Operationchannellist............................................................................................................................7 2.5.MeasurementInstrumentsList...............................................................................................................8 3.EvaluationResults(Evaluation)..................................................................................................................10 3.1.Antennarequirement............................................................................................................................10 4.RadioSpectrumMatterTestResults(RF)..................................................................................................10 4.1.ConductedEmissionatACpowerline.................................................................................................10 4.2.OccupiedBandwidth............................................................................................................................14 4.3.MaximumConductedOutputPower....................................................................................................15 4.4.PowerSpectralDensity........................................................................................................................16 4.5.Emissionsinnon-restrictedfrequencybands......................................................................................17 4.6.Bandedgeemissions(Radiated).........................................................................................................18 4.7.Emissionsinfrequencybands(below1GHz)......................................................................................23 4.8.Emissionsinfrequencybands(above1GHz)......................................................................................26 5.EUTTESTPHOTOS......................................................................................................................................33 6.PHOTOGRAPHSOFEUTCONSTRUCTIONAL..........................................................................................35 Appendix............................................................................................................................................................36 6.1.AppendixA:DTSBandwidth................................................................................................................37 6.2.AppendixB:OccupiedChannelBandwidth.........................................................................................40 6.3.AppendixC:Maximumconductedoutputpower.............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

JappanID:R210-230558 ConductedEmissionatACpowerline Emissionsinfrequencybands(below1GHz) Emissionsinfrequencybands(above1GHz) RFConducted

Contact Information

Applicant

Qin Wei(Deputy general manager of R&D)
[email protected]+86-021-57766651Fax: +86-021-57766651

Technical Contact

RUNHOOD POWER INC.
[email protected]

United States

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]+(86) 0755-2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz28.18 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from RUNHOOD POWER INC.

RESIDENTIAL ESS & PORTABLE POWER STATION - FCC ID 2BB59-F3600-US - RUNHOOD POWER INC.
2BB59-F3600-US

RESIDENTIAL ESS & PORTABLE POWER STATION

Apr 02, 2024

Equipment Class

JAB - Part 15 Class B Digital Device
Portable power station - FCC ID 2BB59-HE1200-US - RUNHOOD POWER INC.
2BB59-HE1200-US

Portable power station

Jul 24, 2023

Equipment Class

8CC - Part 18 Consumer Device