2BBDH-BLDS60-AMobile Radar Device

Integrity Communications Solutions, Inc.

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Jan 16, 2026
Application Purpose
Original Equipment
Equipment Note
Mobile Radar Device
Frequency Range
60000.00000000 - 63950.00000000
Company
Integrity Communications Solutions, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

4040 E Bijou Street, Colorado Springs, CO 80909 T. 719-728-4994 E. [email protected] Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 19, 2025 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2BBDH-BLDS60-A Integrity Communications Solutions, certifies that, as of the date of the filing of the application, Integrity Communications Solutions is our designated U.S. agent for service of process for the above referenced FCC ID. Integrity Communications Solutions, accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Integrity Communications Solutions accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Integrity Communications Solutions FRN: 0028090454 Address: 4040 E Bijou St, Ste 105, Colorado Springs CO 80909 Contact Person: Michael Tipton Tel.: 719-331-0476 Email: [email protected] __________________________ US Agent Signature

Attestation Statements

4040 E. Bijou St., Ste. 120 Colorado Springs, CO 80909 www.integritycsinc.com EST. 2009 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 11/6/2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BBDH-BLDS60-A Integrity Communication Solutions, Inc. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Integrity Communication Solutions, Inc. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). ☒ Device is inherently compliant based on hardware limitations or software controls. or ☐ A Software Bill of Materials (SBOM) is provided to the TCB for review, and ☐ The end-user or third parties cannot install additional software on this device. Sincerely, Michael Tipton Chief Executive Officer Integrity Communications Solutions, Inc. 4040 E. Bijou St., Ste 120 Colorado Springs, CO 80909 [email protected] (719) 331-0476 4040 E. Bijou St., Ste. 120 Colorado Springs, CO 80909 www.integritycsinc.com EST. 2009 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 11/6/2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BBDH-BLDS60-A Integrity Communication Solutions (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Michael Tipton Chief Executive Officer Integrity Communications Solutions, Inc. 4040 E. Bijou St., Ste 120 Colorado Springs, CO 80909 [email protected] (719) 331-0476

Cover Letter(s)

4040 E Bijou Street, Colorado Springs, CO80909 T. 719-728-4994 E. [email protected] 29 October 2025 Federal Communications Commission Equip Approval Services Post Office Box 358315 Pittsburgh, Pennsylvania 15215-5315 To Whom It May Concern: Pursuant to 47 CFR 2.911, Integrity Communications Solutions has authorized Fox Lane, Karthik Vepuri, and Blake Winter of the Nebraska Center for Excellence in Electronics (NCEE Labs), at 4740 Discovery Drive, Lincoln, NE 68521 to act on Integrity Communications Solutions behalf for the sole and express purpose of processing applications to the Federal Communication Commission (FCC) for equipment FCC authorization. This authorization is limited to FCC ID: 2BBDH-BLDS60-A. Consistent with the foregoing, Fox Lane, Karthik Vepuri, and Blake Winter are authorized to the following: 1) Sign Form 731 2) Sign letters of application 3) Request confidentiality 4) Exchange data and information with the FCC, and authorized TCBs on behalf of Integrity Communications Solutions. This authorization is not assignable to others beyond Fox Lane, Karthik Vepuri, and Blake Winter. No party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C 862. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. This authorization expires October 29, 2027. Sincerely, Michael Tipton President & CEO Integrity Communications Solutions

Cover Letter(s)

Page 1 of 1 Request for Confidentiality Date: September 8, 2025 Subject: Confidentiality Request for: FCC ID: 2BBDH-BLDS60-A IC: 33819-BLDS60-A Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 12.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☒ Permanent ☐ Not Provided Block Diagrams ☒ Short Term ☐ Not Provided External Photos ☒ Short Term ☐ Permanent ☐ Not Provided Internal Photos ☐ Short Term ☒ Permanent ☐ Not Provided Operation Description/Theory of Operation ☐ Short Term ☐ Permanent ☒ Not Provided Parts List & Placement/BOM ☐ Short Term ☐ Permanent ☒ Not Provided Tune-Up Procedure ☐ Short Term ☒ Permanent ☐ Not Provided Schematics ☒ Short Term ☐ Not Provided Test Setup Photos ☒ Short Term ☐ Permanent ☐ Not Provided User’s Manual The above-mentioned company has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality (if applicable): The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify Timco in the event information regarding the product or the product is made available to the public before the requested period has expired. Timco will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04- 1705. Sincerely, By: __________________________ Fox Lane, EMC Test Engineer, NCEE Labs

RF Exposure Info

The Nebraska Center for Excellence in Electronics (NCEE) authorizes the above-named company to reproduce this report provided it is reproduced in its entirety for use by the company’s employees only. Any use that a third party makes of this report, or any reliance on or decisions made based on it, are the responsibility of such third parties. NCEE accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. RF Exposure Evaluation Report Client: Integrity Communication Solutions Address: 4040 E Bijou St. Ste 105, Colorado Springs CO, 80909 Model: BLDS60-A Test Report No.: RFE20241015-70-M2 Rev. 0 Approved By: __________________ Fox Lane, EMC Test Engineer Date: January 2, 2026 Total Pages: 11 NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 2 of 11 Revision Page Rev. No. Date Description Original 2 January 2026 Issued by FLane Prepared by FLane NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 3 of 11 1 Regulatory Requirements: FCC Part 1.1310, 2.1091, 2.1093 KDB 447498 D01 RSS-102, Issue 6 EN IEC 62311:2020 Summary: The purpose of this report is to evaluate the EUT’s transmitter for exemption from routine SAR testing. EUT: Model: BLDS60-A FCC ID: 2BBDH-BLDS60-A IC: 33819-BLDS60A HVIN: BLDS60-A MPE Lab Nebraska Center for Excellence in Electronics MPE Labs FCC Cab Designation: US1060 MPE Labs ISED Cab Designation: US0177 Notes: added NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 4 of 11 2 FCC FCC Limits, Part 1.1310 Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300-1,500 f/300 6 1,500-100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1,500 f/1500 30 1,500-100,000 1.0 30 NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 5 of 11 Occupational/Controlled ☐ General Population/uncontrolled ☒ FCC Power Density Calculations, eCFR 2.1091 Freq. Conducted Power Antenna Gain EIRP EIRP +10% for Tolerance Power Density Limit at specified distance % of limit Result MHz mW numerical mW mW mW/cm^2 mW/cm^2 % 60000.00 5.582 1.26 7.03 7.73 0.002 1.00 0.154 PASS 62000.00 20.255 1.26 25.50 28.05 0.006 1.00 0.558 PASS 64000.00 22.393 1.26 28.19 31.01 0.006 1.00 0.617 PASS Distance (d) 20 cm S = (P x G)/(4 x π x d^2) – used to calculate exposure at "d" cm EIRP = P x G, measured as field strength d = √(S/(P x G) x 4 X π) – used to calculate minimum distance to meet limits S = power density (mW/cm^2) P = transmitter conducted power (in mW) G = antenna numeric gain (Numerical) d = distance to radiation center (cm) Results: Complies Note: The user’s manual will stipulate that a 20cm distance from the user is to be maintained. EIRP values in mW were multiplied by 1.1 to account for a 10% tolerance. NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 6 of 11 3 ISED RSS 102, Issue 6, Section 6.4 (for distances less than 20cm) NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 7 of 11 RSS 102, Issue 6, Section 6.6 (for distances 20cm or greater) NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 8 of 11 Occupational/Controlled ☐ General Population/uncontrolled ☒ ISED Power Density Calculations, RSS-102 Frequency EIRP Antenna Gain Peak Power EIRP Peak Power EIRP +10% for Tolerance Power Density Limit at specified distance % of limit Result MHz mW numerical mW mW mW/cm^2 mW/cm^2 % 60000.00 5.582 1.00 5.58 6.14 0.001 1.00 0.122 PASS 62000.00 20.255 1.00 20.26 22.28 0.004 1.00 0.443 PASS 64000.00 22.393 1.00 22.39 24.63 0.005 1.00 0.490 PASS Antenna Gain set to 1.00 because power measurements were performed with radiated method Distance (d) 20 cm S = (P x G)/(4 x π x d^2) – used to calculate exposure at "d" cm EIRP = P x G, measured as field strength d = √(S/(P x G) x 4 X π) – used to calculate minimum distance to meet limits S = power density (mW/cm^2) P = transmitter conducted power (in mW) G = antenna numeric gain (Numerical) d = distance to radiation center (cm) Note: The user’s manual will stipulate that a 20cm distance from the user is to be maintained. EIRP values in mW were multiplied by 1.1 to account for a 10% tolerance. Result: The EUT was found to be exempt from routine SAR testing and COMPLIANT with FCC and ISED RF exposure requirements. NCEE Labs Report Number: RFE20241015-70-M2 Rev. 0 Test Report Prepared for Integrity Communication Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 9 of 11 4 EU EN 62311:2020 states the EUT shall comply with the limit restrictions can be found in Annex III of the Council Recommendation 1999/519/EC [1] NCEE Labs Report Number: RFE20241015-…

Text truncated - open the document above for the full version.

Test Report

The Nebraska Center for Excellence in Electronics (NCEE) authorizes the above-named company to reproduce this report provided it is reproduced in its entirety for use by the company’s employees only. Any use that a third party makes of this report, or any reliance on or decisions made based on it, are the responsibility of such third parties. NCEE accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Test Report Prepared for: Integrity Communications Solutions Address: 4040 E Bijou St. Ste 105, Colorado Springs CO, 80909 Product: BLDS60-A Test Report No: R20241015-70-E1 Rev: B Approved by: __________________ Fox Lane, EMC Test Engineer DATE: January 2, 2026 Total Pages: 26 Report Number: R20241015-70-E1 Rev B Prepared for: Integrity Communications Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 2 of 26 REVISION PAG E Rev. No. Date Description 0 4 September 2025 Issued by FLane Prepared by FLane A 10 November 2025 Added Timing Measurement Updated IC ID – FL B 2 January 2026 Added data from new device housing – FL Report Number: R20241015-70-E1 Rev B Prepared for: Integrity Communications Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 3 of 26 CONT ENT S Revision Page ............................................................................................................................................................................... 2 1.0 Summary of test results ....................................................................................................................................... 4 2.0 EUT Description .................................................................................................................................................... 5 2.1 Equipment under test ........................................................................................................................................ 5 2.2 Description of test modes ................................................................................................................................ 5 2.3 Description of support units ............................................................................................................................ 5 3.0 Laboratory and General Test Description ........................................................................................................ 6 3.1 Laboratory description ...................................................................................................................................... 6 3.2 Test personnel ..................................................................................................................................................... 6 3.3 Test equipment.................................................................................................................................................... 7 3.4 General Test Procedure and Setup for Radio Measuremnts ................................................................... 8 4.0 Results .................................................................................................................................................................. 10 4.1 Output Power/Field Strength ......................................................................................................................... 11 4.2 Bandwidth ........................................................................................................................................................... 14 4.3 Radiated emissions .......................................................................................................................................... 15 4.4 Frequency Error ................................................................................................................................................ 20 4.5 OFF-times ........................................................................................................................................................... 22 Appendix A: Sample Calculation ........................................................................................................................................... 24 Appendix B – Measurement Uncertainty .............................................................................................................................. 25 REPORT END ..................................................................................................................................................................... 26 Report Number: R20241015-70-E1 Rev B Prepared for: Integrity Communications Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 4 of 26 1.0 SU MMAR Y OF TEST R ESULT S The worst-case measurements were reported in this report. Summary of test results presented in this report correspond to the following section (Please see the checked box below for the rule part used): The EUT has been tested according to the following specifications: (1) US Code of Federal Regulations, Title 47, Part 15.255 (2) ISED RSS-210 Issue 11 (3) ISED RSS-Gen, Issue 5 APPLIED STANDARDS AND REGULATIONS Standard Section Test Type Result FCC Part 15.255 (c)(2)(iii)(A) RSS-210 J.3.2 (b)(iii) EIRP Complies FCC Part 15.255 (d) RSS-210 J.4 / J.5 Spurious Emissions Complies FCC Part 15.255 (f) RSS-210 J.6 Frequency Stability Complies Report Number: R20241015-70-E1 Rev B Prepared for: Integrity Communications Solutions The Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521 Page 5 of 26 2.0 EUT D ESC RIPT ION 2.1 EQU IPMENT UND ER T EST Summary and Operating Condition: EUT BLDS60-A FCC ID 2BBDH-BLDS60-A IC ID 33819-BLDS60A EUT Received 19 February 2025 EUT Tested 19 February 2025 - 2 Jan…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Michael Tipton(President/CEO)
[email protected]Fax: 8664721346

Technical Contact

Integrity Communications Solutions80909 Tipton
[email protected]

4040 E Bijou St · Colorado Springs, Colorado, 80909 · United States

Test Firm

Nebraska Center for Excellence in ElectronicsKarthik Vepuri
[email protected]Fax: 4024725881

Technical Specifications

#Rule PartsFrequency RangePower Output
115.25560.00 GHz - 63.95 GHz22.39 mW
Confidentiality
Long Term
Grant Notes
Power listed is EIRP. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions to satisfy RF exposure compliance. This device may only be operated on aircraft with the restrictions of §15.255(b)(2). This device may not be installed on satellites.