Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
3500 SERIES RESIDENTIAL GRADE DEADBOLT 1 Do this first: Hardware Installation 1 Install your lock. Use this Hardware Installation Guide to get your lock installed. You are here. Get connected. Use the Connection Guide to get your lock online and registered. Take control. Now your lock is fully functional and can be managed from anywhere. 2 3 Here’s what you’ll need: Four AA Batteries Phillips Screwdriver OPTIONAL: Power Drill 2 1/8” Hole Saw 1” Drill Bit Measuring Tape Adhesive Tape What’s in the box? Interior Lock Exterior Lock Mounting Plate Strike Plate Deadbolt Latch Key Set Hardware Pack Let’s get started. First things first, let’s get your new lock installed. Drilling new holes? Most doors will have an existing hole drilled for a deadbolt installation. If your door needs to be drilled, you’ll need to drill a 2 1/8“ (54mm) hole for the lockset on the face of the door, as well as a 1” bore hole for the latch on the edge of the door. Edge Bore Hole for Latch Face Bore Hole The backset is the distance from the center of the face bore hole to the edge of the door. STEP 1 Position the template. If your door already has a latch and face bore hole, please proceed to STEP 3. Use the template to the right to mark the center of each hole precisely. Once the template is aligned, tape the template in place. Quick Tip TEMPLATE Fold and fit door edge on this line. Drill a 1 in diameter latch hole at the exact center of your door’s edge. Drill a 2 in (54mm) diameter hole for either a 2¾ in or 2 in backset. 2¾ in (70mm ) 2 in (60mm) 2” 51mm 1 3/4” 1 9/16” 1 3/8” 45mm 40mm 35mm Drill a 2 in (54mm) diameter hole for either a 2¾ in or 2 in backset. 2¾ in (70mm ) 2 in (60mm) TEMPLATE Fold and fit door edge on this line. Drill a 1 in diameter latch hole at the exact center of your door’s edge. 1 3/8” 35mm 1 9/16” 40mm 1 3/4” 45mm 2” 51mm Interior of Door Exterior of Door STEP 2 Mark carefully and drill. Use a thumbtack or sharp object to mark the center of each hole you will drill. Mark the exterior of the door, then apply the template to the interior of the door. Make sure the holes are aligned precisely from one side of the door to the other and double check all the measurements and markings. Interior of Door Edge of Door Exterior of Door Align the drill bit over your mark and hold the door steady. Keep the drill level and straight. Drill the 2 1/8“ face bore halfway through on the first side. Then drill the remaining half from the other side of the door. This prevents damage to the door and improves accuracy. Finally, use a 1” drill bit to drill the edge bore hole until you reach the face bore hole. Interior of Door Edge of Door Exterior of Door STEP 3 Measure the backset and adjust the latch to fit. The backset is the distance between the center of the face bore hole to the edge of the door. The deadbolt latch has two positions, for either a 2 ⅜” (60mm) or 2 ¾” (70mm) backset. Rotate the latch case clockwise for 2 ¾”. Rotate the latch counter- clockwise for 2 ⅜”. Exterior of Door Interior of Door X2 Make sure the latch plate lays flush with the door. If the latch plate is not flush with the door, draw an outline around the faceplate edge and chisel a rebate to allow the latch to lay flush with the door edge. STEP 4 Install latch. Insert the latch and make sure it is flush with the door frame. Ensure the symbol on the latch is pointed up. Hand tighten with two of the included wood screws. Quick Tip Make sure the power cable is inserted under the latch and the tailpiece is inserted horizontally. STEP 5 Position keypad. Position the keypad on the exterior of the door. Ensure that the deadbolt latch is retracted and pass the power cable under the latch. Insert the tailpiece into the hub of the latch, making sure it is in the horizontal position. Quick Tip Interior of Door Exterior of Door X2 STEP 6 Attach mounting plate. Hold the mounting plate up to the interior of the door, making sure the prongs are facing up and outward. Pass the power cable through the bottom center hole in the mounting plate. Secure the mounting plate to the exterior half of the lock with the 2 included long bolts. BOTTOM CENTER HOLE Take a picture of the serial number sticker on the back of the lock. The serial number can also be found on the exterior of the lock’s packaging. Model : OE-3500 Serial : AC000W000000000 MacID : E04F00000000 STEP 7 Prepare the interior lock. Remove the battery cover from the interior of the lock by sliding the cover upward and pulling it off. Ensure the thumb turn knob is still in the unlocked position by turning it to face away from the edge of the door. Quick Tip X3 STEP 8 Attach interior lock. Connect the front lock’s power cable to the interior lock. Next, place the interior lock onto the tailpiece and mounting plate. Secure to the mounting plate using the 3 included short bolts. Ensure the thumb turn moves freely, extending and retracting the latch. (OPTIONAL STEP) A wood screw is provided and can be used to screw the lock directly to a wood door in a more permanent and secure manner. This hole is located in the top, middle portion of the battery compartment. OPTIONAL STEP 9 Insert batteries. Insert four AA alkaline or lithium batteries into the battery compartment. Slide the battery cover back onto the lock. Rechargeable batteries should never be used in this device because they do not support the necessary voltage. Please only use name brand alkaline or lithium batteries. ! IMPORTANT. DO NOT MISS THIS STEP. The default programming code is 123456 but this will be reset after 24 hours of connecting your lock for the first time. STEP 10 Set handing. Ensure the deadbolt is in the unlocked position. Then, enter the lock’s , button, 140, button. When handing is correctly set, you will see two green flashes and hear two beeps. Quick Tip STEP 11 Add User Code. Add a custom User Code via the keypad. User Codes can be 4–8 digits in length. To add a User Code, enter the following on the lock’s keypad: Ent…
Text truncated - open the document above for the full version.
3500 SERIES RESIDENTIAL GRADE LEVER 1 Do this first: Hardware Installation 1 Install your lock. Use this Hardware Installation Guide to get your lock installed. You are here. Get connected. Use the Connection Guide to get your lock online and registered. Take control. Now your lock is fully functional and can be managed from anywhere. 2 3 Here’s what you’ll need: Four AA Batteries Phillips Screwdriver OPTIONAL: Power Drill 2 1/8” Hole Saw 1” Drill Bit Measuring Tape Adhesive Tape What’s in the box? Interior Lock Exterior Lock Mounting Plate Strike Plate Key Set Latch Hardware Pack Let’s get started. First things first, let’s get your new lock installed. Drilling new holes? Most doors will have an existing hole drilled for a lever lock. If your door needs to be drilled, you’ll need to drill a 2 1/8“ (54mm) hole for the lockset on the face of the door, as well as a 1” bore hole for the latch on the edge of the door. Edge Bore Hole for Latch Face Bore Hole The backset is the distance between the center of the face bore hole to the edge of the door. STEP 1 Position the template. If your door already has a latch and face bore hole, please proceed to STEP 3. Use the template to the right to mark the center of each hole precisely. Once the template is aligned, tape the template in place. Quick Tip TEMPLATE Fold and fit door edge on this line. Drill a 1 in diameter latch hole at the exact center of your door’s edge. Drill a 2 in (54mm) diameter hole for either a 2¾ in or 2 in backset. 2¾ in (70mm ) 2 in (60mm) 2” 51mm 1 3/4” 1 9/16” 1 3/8” 45mm 40mm 35mm Drill a 2 in (54mm) diameter hole for either a 2¾ in or 2 in backset. 2¾ in (70mm ) 2 in (60mm) TEMPLATE Fold and fit door edge on this line. Drill a 1 in diameter latch hole at the exact center of your door’s edge. 1 3/8” 35mm 1 9/16” 40mm 1 3/4” 45mm 2” 51mm Interior of Door Exterior of Door STEP 2 Mark carefully and drill. Use a thumbtack or sharp object to mark the center of each hole you will drill. Mark the exterior of the door, then apply the template to the interior of the door. Make sure the holes are aligned precisely from one side of the door to the other and double check all the measurements and markings. Interior of Door Edge of Door Exterior of Door Align the drill bit over your mark and hold the door steady. Keep the drill level and straight. Drill the 2 1/8“ face bore halfway through on the first side. Then drill the remaining half from the other side of the door. This prevents damage to the door and improves accuracy. Finally, use a 1” drill bit to drill the edge of the door with the latch bore hole. Drill until you reach the face bore hole. Interior of Door Edge of Door Exterior of Door STEP 3 Measure the backset and adjust the latch to fit. The backset is the distance between the center of the face bore hole to the edge of the door. The lever latch has two positions, when retracted it will fit a 2 ⅜” (60mm) backset or when extended, will fit a 2 ¾” (70mm) backset. POSITION 1 POSITION 2 X2 Make sure the latch plate lays flush with the door. If the latch plate is not flush with the door, draw an outline around the faceplate edge and chisel a rebate to allow the latch to lay flush with the door edge. STEP 4 Install latch. Insert the latch and make sure it is flush with the door frame. Ensure the symbols on the latch are pointed up. Hand tighten with two of the included wood screws. The guard latch should face the exterior of the door. Quick Tip Exterior of Door Exterior of Door GUARD LATCH Make sure the power cable is inserted above the latch and the latch tailpiece is in the vertical position.. STEP 5 Position keypad. Place the keypad portion of the lock on the exterior side of the door. Pass the power cable over the latch to the interior side of the door. Ensure the tailpiece is in the vertical position and inserted through the hub of the latch. Quick Tip Interior of Door POWER CABLE TAILPIECE Exterior of Door X2 STEP 6 Attach mounting plate. Hold the mounting plate up to the interior of the door, making sure the prongs are facing up and outward. Pass the power cable through the upper center hole on the mounting plate. Secure the mounting plate to the exterior half of the lock with the two included long bolts. If the lock appears crooked or lopsided, loosen the screws, adjust its position, and retighten. UPPER CENTER HOLE Interior of Door Take a picture of the serial number sticker on the back of the lock. The serial number can also be found on the exterior of the lock’s packaging. Model : OE-3500 Serial : AC000W000000000 MacID : E04F00000000 STEP 7 Prepare the interior lock. Remove the battery cover from the interior of the lock by sliding the cover upward and pulling it off. The lever lock’s thumb turn should still be in the horizontal, unlocked position and the tailpiece slot should be in the vertical position. Quick Tip VERTICAL TAILPIECE SLOT UNLOCKED THUMB TURN X3 STEP 8 Attach interior lock. Connect the front lock’s power cable to the interior lock. Next, place the interior lock on the mounting plate making sure it is pressed flush to the door and the screw holes align with the mounting plate. Secure the interior lock to the mounting plate using the 3 included short bolts. (OPTIONAL STEP) A wood screw is provided and can be used to screw the lock directly to a wood door in a more permanent and secure manner. This hole is located in the top, middle portion of the battery compartment. OPTIONAL STEP 9 Install handles. With the levers still in the unlocked position, insert the provided pin wrench into the small hole on the neck of the lever and apply pressure to depress the catch. Once the catch has been depressed, pull out the lever from the stem. Follow the same steps to remove the lever from the other side of the lock to exchange the position of the levers or change the lock’s ‘handing’. Quick Tip Lever handles should face away from the edge of the door to ensure smooth and ergonomic opening and closing. Interior of Door …
Text truncated - open the document above for the full version.
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 Applicant as U.S. Agent Letter of Attestation Date: 11-24-2023 To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BBNS-KL550 KoreLock, Inc. (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. Designated U.S. Agent from Applicant Company Company Name: Robert Goff Contact Person: KoreLock, Inc. Address: 7100 E Belleview Ave, Suite 203, Greenwood Village, CO 80111 USA Tel.: 303.681.5785 Email: [email protected] FCC FRN: 0033882762 Sincerely yours, Robert Goff Title: Co-Founder/VP, Product Email: [email protected]
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 11-24-2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BBNS-KL550 KoreLock, Inc. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Printed Name: Robert Goff Title: Co-Founder/VP, Product Address: 7100 E Belleview Ave, Suite 203, Greenwood Village, CO 80111 USA Tel.: 303.681.5785 Email: [email protected]
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 11-24-2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BBNS-KL550 KoreLock, Inc.(“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Robert Goff Title: Co-Founder/VP, Product Address: 7100 E Belleview Ave, Suite 203, Greenwood Village, CO 80111 USA Tel.: 303.681.5785 Email: [email protected]
KoreLock, Inc. 8301 E Prentice Ave, Suite 215 Greenwood Village, CO 80111 USA 303.681.5785 Authority to Act as Agent Date: June 1, 2023 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint Mr. Raghavendra Kulkarni to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with KoreLock, Inc at 8301 E Prentice Ave, Suite 215 Greenwood Village, CO 80111 USA. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: June 1, 2023 Agreement is valid for 12 months from the above date. By: __________________________ __Robert Goff______________ (Signature) (Print name) _Co-Founder/VP, Product_____ __720-250- 7780____________ (Title) On behalf of: __KoreLock, Inc.____________ (Company Name) (Telephone) Page 1 of 1
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 MS-0044715 Page 1 of 1 Revision 1 Legal Scope: Global Business Scope: Cross Business Process Scope: Cross Process Date: 24-Nov-2023 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BBNS-KL550 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Gain Information Datasheet Korelock Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, Robert Goff By: _______________________________________________ ________________________ (Signature/Title) (Print name) Tel: +1 720-250-7780 Email: [email protected]
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 The key difference between the two variants is as follows. 3500 Series Deadbolt Lock (Varinat#1) 3500 Series Lever Lock (Varinat#2) Mechanical Enclosure A deadbolt is a single- cylinder lock that extends or retracts by turning a key or thumb turn. It is typically a solid, rectangular bolt that slides into the door jamb when locked. Deadbolts are commonly used as secondary locks in addition to regular knob or lever locks. A lever door lock, on the other hand, uses a lever handle to engage or disengage a spring-loaded latch. Lever locks can be used without a deadbolt lock on a door. PCBA KL-PCB-550 KL-PCB-550 Antenna BLE & WiFi – PCB Antenna BLE & WiFi – PCB Antenna Schematic All the components are same including DC-DC Converter, Buzzer, BLE & WiFi module, Switches, Keypad, Flash memory, Motor Driver All the components are same including DC-DC Converter, Buzzer, BLE & WiFi module, Switches, Keypad, Flash memory, Motor Driver Power Supply 6V DC 6V DC
KoreLock, Inc. 7100 E. Bellevue Ave. Suite 203 Greenwood Village, CO 80111 USA 303.681.5785 Date: Jan 09, 2024 Justification for Re-use of Radio Test Results We, KoreLock Inc, believe that the conducted signal test data on original reports provided by the Laird Technologies FCC ID: SQGBL654 Report# FR813002 on 29 th Jun 2018 & ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD FCC ID: 2AC7Z-ESPS2MINI2 Report# FR262713 on 10 th Nov 2022 can be re-used for the following reasons: 1. Applicant has built in the radio module according to the specific radio module integration guides. 2. No changes have been made on radio module. 3. Re-test the conducted power for spot check verification, the radiated spurious emission, and reevaluated the RF Exposure. Also, we have disabled the 801.15.4 proprietary protocol in the BLE module. By Robert Goff Title: VP, Product
Produkte Products www.tuv.com EUT External Photos Reference Test Report No: IN23BVW8 001 Seite 1 von 5 Page 1 of 5 EUT EXTERNAL PHOTOS 3500 Series Deadbolt Lock 3500 Series Lever Lock Produkte Products www.tuv.com EUT External Photos Reference Test Report No: IN23BVW8 001 Seite 2 von 5 Page 2 of 5 EUT Front View EUT SideView Produkte Products www.tuv.com EUT External Photos Reference Test Report No: IN23BVW8 001 Seite 3 von 5 Page 3 of 5 EUT Side View EUT Dimensional View Produkte Products www.tuv.com EUT External Photos Reference Test Report No: IN23BVW8 001 Seite 4 von 5 Page 4 of 5 EUT Dimensional View EUT Dimensional View Produkte Products www.tuv.com EUT External Photos Reference Test Report No: IN23BVW8 001 Seite 5 von 5 Page 5 of 5 EUT Front View EUT Side View
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including, an interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body FCC ID: 2BBNS-KL550Model: KeyInCode 3500 Series Compliance Statement Label QR Label
Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: IN23BVW8 001 Seite 1 von 3 Page 1 of 3 EUT INTERNAL PHOTOS BLE Module Without Shield Wi-Fi Module close up view without shield Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: IN23BVW8 001 Seite 2 von 3 Page 2 of 3 PCB Dimensional View PCB Dimensional View Produkte Products www.tuv.com EUT Internal Photos Reference Test Report No: IN23BVW8 001 Seite 3 von 3 Page 3 of 3 KL-PCB-550 PCB with Shield Rear side KL-PCB-550 PCB with Shield front side
Prüfbericht – Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: IN23BVW8 001 Auftrags-Nr.: Order no.: 146797959 0010 Seite 1 von 3 Page 1 of 3 Kunden-Referenz-Nr.: Client reference no.: 2133653 Auftragsdatum: Order date: 2023-06-07 Auftraggeber: Client: KoreLock, Inc 7100 E. Belleview Ave., Ste. 203, Greenwood Village, CO 80111 Prüfgegenstand: Test item: KeyInCode 3500 Series Smart Lock Bezeichnung Identification 3500 Series Deadbolt Lock 3500 Series Lever Lock Auftrags-Inhalt: Order content: Maximum Permissible Expsoure Prüfgrundlage: Test specification: FCC 1.1310, KDB 447498 D01 Wareneingangsdatum: Date of sample receipt: 2023-06-07 Prüfmuster-Nr.: Test sample no: Serien -Nr.: Serial no.: A003491436-001 & A003491436- 003 Engineering Sample Prüfzeitraum: Testing period: 2023-07-03 - 2023-11-03 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt. Ltd. 27/B,2nd cross road, Electronic city Phase1, Banglore-560100, India FCC Test Site Registration No: 496599 IC Test Site Registration No: 27711 Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2023-11-05 Ausstellatum: Issue date: 2024-02-02 Stellung / Position: M.V.Naveen Kumar Senior Engineer Stellung / Position: Lokesh Ramu Senior Manager Sonstiges / Other: FCC ID: 2BBNS-KL550 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd, Plot No.27/B, 2nd Cross, Electronic city, Industrial Area, Phase I, Hosur Road Bangalore-560 100, India Mail: [email protected] ∙ Web: www.ind.tuv.com Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: IN23BVW8 001 Seite 2 von 3 Page 2 of 3 1 Maximum Permissible Exposure 1.1 RF Exposure Compliance Requirement The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 1.2 RF Exposure Limits: 1.2.1 For FCC 1. According to FCC Part 1 Subpart I 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) showed in Table 1. F or ƒ = Frequency in MHz Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation. Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: IN23BVW8 001 Seite 3 von 3 Page 3 of 3 Test Results: Antenna details: Sl.No RF Protocols Antenna Type Antenna Gain (dBi) 1 Wi-Fi 2.4GHz Printed PCB monopole antenna – on-board 4.54 2 BLE Printed PCB trace monopole antenna – on- board -1.05 Radio Protocol Antenna Model Frequency (MHz) Maximum measured RF output power with tune- up Value (dBm) Max power Including tune-up tolerance * (mW) Antenna Gain in linear Min Separation distance (CM) Power Density (Pd)(mW/cm²) FCC Limit (mW/cm2) BLE Printed PCB monopole antenna – on-board 2440 8.00 6.3095 0.7852 20 0.0009 1 Wi-Fi 2462 16.00 39.8107 2.844 20 0.0225 1 Exemption calculation for simultaneous Operation: RF Protocol Calculated MPE Final MPE Limit Wi-Fi 2.4GHz + BLE 0.0009+0.0225 0.0234 <1 Note: 1. For above table, to calculate MPE following formula is used MPE RF 1 / Limit RF 1 + MPE RF2 / LIMIT RF 2 + ..... +MPE RFn / Limit RFn < 1 2. Maximum conducted output power taken from test Reports: IN23BVW8 001 1.3 Conclusion The Power density of the EUT is less than defined limit as shown above, Hence EUT is meeting MPE Calculation.
https://www.lairdconnect.com/bl654 Laird Connectivity 50 S. Main St. Suite 1100 Akron, OH 44308 USA
Wireless Device Over the Air Performance Data Summary REPORT NO. : OQ1D0806 EQUIPMENT : ESP-ANT S-H BRAND NAME : ESPRESSIF MODEL NAME : ESP32-S3-MINI-1 DEVICE RECEIVING DATE : Nov. 16, 2021 TEST DATE(S) : Nov. 16, 2021 ~ Nov. 16, 2021 Reviewed by: Approved by: Feynman Liu / Vice Manager Kevin Chu / Manager Sporton International (Kunshan) Inc. No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People’s Republic of China Sporton International (Kunshan) Inc. Page Number : 2 of 10 TEL : +86-512-57900158 Report Issued Date : Dec. 14, 2021 FAX : +86-512-57900958 Report Version : 1.0 Wireless Device OTA RF Performance Data Summary Report No. : OQ1D0806 Table of Contents Revision History ---------------------------------------------------------------------------------------------------------------------- 3 1. Administration Data ----------------------------------------------------------------------------------------------------------- 4 1.1 Testing Laboratory ------------------------------------------------------------------------------------------------------- 4 1.2 Applicant ------------------------------------------------------------------------------------------------------------------- 4 2. Product Photo ------------------------------------------------------------------------------------------------------------------- 4 3. Summary of Test Results ---------------------------------------------------------------------------------------------------- 5 4. FS Pattern ------------------------------------------------------------------------------------------------------------------------- 6 5. Description for EUT Testing Position ------------------------------------------------------------------------------------ 9 Sporton International (Kunshan) Inc. Page Number : 3 of 10 TEL : +86-512-57900158 Report Issued Date : Dec. 14, 2021 FAX : +86-512-57900958 Report Version : 1.0 Wireless Device OTA RF Performance …
Text truncated - open the document above for the full version.
7100 E. Bellevue Ave. Suite 203 · Greenwood Village, Colorado · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 348.30 mW |

PDQ series locks
Equipment Class
DTS - Digital Transmission SystemKeyInCode 5200 Series Smart Lock
Equipment Class
DTS - Digital Transmission System