Rev2/6/2023 WinnersIndustryCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2024.3.28 FCCID:2BBPU-24MG-WRGB1838 Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing [WinnersIndustryCo.,Ltd.](“theapplicant”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing [WinnersIndustryCo.,Ltd.](“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicant[isnot]identifiedontheCoveredListasanentityproducing“covered” equipment. CoverListLink:(https://www.fcc.gov/supplychain/coveredlist) Applicant:WinnersIndustryCo.,Ltd. Address:1400BRANDYWINEDRIVE,TYLER,TX75703,UnitedStates ContactPerson:MrNathanIhrig Tel.:(903)714-2133 Email:[email protected] Sincerely,
Rev2 WinnersIndustryCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA FCCID:2BBPU-24MG-WRGB1838 DateofFilingtoTCB:2024.3.28 Ref:AttestationStatementsPart2.911(d)(7)Filing [WinnersIndustryCo.,Ltd.](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication, [WinnersIndustryCo.,Ltd.]isourdesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID.[WinnersIndustryCo.,Ltd.]acceptstomaintainanagentfornolessthanoneyearafterthe granteehasterminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipmentandwillnotifytheTCB/FCCinatimelymanneriftheUSProcessing Agentchanges. [WinnersIndustryCo.,Ltd.]accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:WinnersIndustryCo.,Ltd. FRN:0033897513 Address:1400BRANDYWINEDRIVE,TYLER,TX75703,UnitedStates ContactPerson:MrNathanIhrig Tel.:(903)714-2133 Email:[email protected] Sincerely, (Applicantprintedname) MrNathanIhrig (Applicantsignature) (USLocalAgentprintedname) MrNathanIhrig (USLocalAgentsignature)
SCS-F019:ConfidentialityRequestLetterPage 1 of 2 Rev8 OneDistributionCenterCircle,Suite1 Littleton,MA01460 Tel:+19784868880 Email:[email protected] Website:https://www.cps.bureauveritas.com/ Confidentiality RequestLetter ReasonforAmendment(current/obsolete) RevisionHistor y ApprovedDate FromTo InitialRelease (obsolete)1.01.0Nov-14-2006 AddingCFR2.459(obsolete)1.02.0August–11-2008 Updatedcompanytemplate&Addedtext box(obsolete) 2.03.0Jan-31-2012 AddedICconfidentialityletterform (obsolete) 3.04.0March-26-2015 CorrectionstoSTCform.Addedreference toKDB(obsolete) 4.05.0Nov-19-2015 Updatedcompanylogo(current)5.06.0Jun-26-2019 UpdatedReferencesandContactInfo6.07.0Aug-30-2020 UpdatedBVCompanyAddress7.08Nov-28-2023 SCS-F019:ConfidentialityRequestLetterPage 2 of 2 Rev8 WinnersIndustryCo.,Ltd. 2024.3.28 To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046-1609 Cc: BureauVeritasConsumerProductsServicesInc. OneDistributionCenterCircle,Suite1 Littleton,MA01460 Subject:ConfidentialityRequestforFCCID:2BBPU-24MG-WRGB1838 PursuanttoCFR47sections0.457and0.459,werespectfullyrequestpermanentconfidentialtreatmentofthe followingExhibitsaccompanyingthisapplicationbeheldconfidential: TypeofConfidentialityRequestedExhibit ShortTermPermanentBlockDiagram ShortTermExternalPhotos ShortTermPermanent i InternalPhotos ShortTermPermanentOperationalDescription/TheoryofOperation ShortTermPermanentPartsList ShortTermPermanentTune-UpProcedure ShortTermPermanentSchematics ShortTermTestSetupPhotos ShortTermPermanent i User’sManual Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic. Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovideunjustifiedbenefitstoits competitors. PermanentConfidentiality: Theapplicantrequeststheexhibitslistedaboveaspermanentlyconfidentialbepermanentlywithheldfrom publicreviewduetomaterialsthatcontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic. Short-TermConfidentiality: Toavoidprematurereleaseofsensitiveinformationpriortomarketingorreleaseoftheproducttothepublic,the applicantrequeststhefollowingdocumentscontainedinthiscertificationapplicationbetemporarilywithheld frompublicdisclosureforaninitialperiodof45 or180days;orforaspecifieddateofnottoexceed 180daysfromtheGrantDate Theapplicantunderstandsthatdisclosureofthisapplicationandallaccompanyingdocumentationwillnotbe madebeforethedateoftheGrantforthisapplication. Sincerely, Client’ssignature: Client’sname: MrNathanIhrig Contactinformation/address:1400BRANDYWINEDRIVE,TYLER,TX75703,UnitedStates i PermanentconfidentialitymayberequestedinaccordancewithFCCKDB726920
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 58 Report Version A Test Report No.: RF2312WDG0098-1 TEST REPORT Applicant Winners Industry Co., Ltd. Address 1400 BRANDYWINE DRIVE, TYLER, TX 75703, United States Manufacturer or Supplier Winners Industry Co., Ltd. Address 1400 BRANDYWINE DRIVE, TYLER, TX 75703, United States Product light string & music box & remote control & adapter Brand Name N/A Model 24MG-WRGB1838 Additional Model & Model Difference N/A Date of tests Dec. 14, 2023 ~ Jan. 16, 2024 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Apr. 01, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 58 Report Version A Test Report No.: RF2312WDG0098-1 TABLE OF CONTENTS RELEASE CONTROL RECORD ..................................................................................................... 5 1 SUMMARY OF TEST RESULTS ............................................................................................. 6 2 MEASUREMENT UNCERTAINTY .......................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT .................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ...................................................................................... 8 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ........................................................ 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................. 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ............................................................................... 11 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................................ 11 3.6 DUTY CYCLE OF TESET SIGNAL ................................................................................... 12 4 TEST TYPES AND RESULTS ............................................................................................... 13 4.1. CONDUCTED EMISSION MEASUREMENT ................................................................ 13 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ........................................ 13 4.1.2 TEST INSTRUMENTS .............................................................................................. 13 4.1.3 TEST PROCEDURES .............................................................................................. 14 4.1.4 DEVIATION FROM TEST STANDARD .................................................................... 14 4.1.5 TEST SETUP ............................................................................................................ 15 4.1.6 EUT OPERATING CONDITIONS ............................................................................. 15 4.1.7 TEST RESULTS........................................................................................................ 16 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT........................................ 18 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ................ 18 4.2.2 TEST INSTRUMENTS .............................................................................................. 19 4.2.3 TEST PROCEDURES .............................................................................................. 20 4.2.4 DEVIATION FROM TEST STANDARD .................................................................... 21 4.2.5 TEST SETUP ...................................................…
Text truncated - open the document above for the full version.
Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 13 Report Version B Test Report No.: AN2312WDG0098 ANTENNA TEST REPORT Applicant Winners Industry Co., Ltd. Address 1400 BRANDYWINE DRIVE, TYLER, TX 75703, United States Manufacturer or Supplier Winners Industry Co., Ltd. Address 1400 BRANDYWINE DRIVE, TYLER, TX 75703, United States Product Antenna Brand Name N/A Model 24MG-WRGB1838 Max. Peak Gain -1.54 dBi Date of tests Apr. 15, 2024 Tested by Andy Zhu Supervisor / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Apr. 17, 2024 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 13 Report Version B Test Report No.: AN2312WDG0098 TABLE OF CONTENTS 1. MEASUREMENTS SETUP ................................................................................................ 3 1.1 TEST PROCEDURE ............................................................................................... 3 2. MEASUREMENT UNCERTAINTY ..................................................................................... 4 3. SIZE OF THE ANTENNA ................................................................................................... 4 4. TEST INSTRUMENTS ....................................................................................................... 5 5. TEST RESULTS ................................................................................................................. 6 6. PHOTOGRAPHS OF THE TEST CONFIGURATION ....................................................... 13 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 13 Report Version B Test Report No.: AN2312WDG0098 1. MEASUREMENTS SETUP 1.1 TEST PROCEDURE a. The EUT was placed on the rotating table 1.5 meters above the ground at a Fully Anechoic Room, the table was rotated 360 degrees. b. The EUT was set 3 meters away from the receiving antenna, which was mounted on the top of a antenna tower. c. The antenna is 1.5 meters above the ground. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 13 Report Version B Test Report No.: AN2312WDG0098 2. MEASUREMENT UNCERTAINTY Expanded Uncertainty for Measurement (k=2 or 95% confidence level) at Passive antenna test over frequency range 1000MHz-6000MHz is +/- 1.86dB. 3. SIZE OF THE ANTENNA Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 13 Report Version B Test Report No.: AN2312WDG0098 4. TEST INSTRUMENTS Equipment Manufacturer Model No. Serial No. Next Cal. Signal Generator Agilent N5183A MY50140980 Jul. 11, 24 Spectrum Analyzer Rohde&Schwarz FSV40 101003 Jan. 01, 25 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 D 9120D-1247 Apr. 02, 25 Broad-Band Horn Antenna SCHWARZBECK BBHA 9120 B 00740 Jul. 20, 24 Turn Table MF MF-7802 MF780208191 N/A Controller MF MF-7802 MF780208243 N/A Test Software BV ADT BV ADT Antenna Pattern V6.2 N/A NOTE: 1. The test was performed in Fully Anechoic Room. 2. Equipment are calibrated by calibration laboratory accredited to ISO/IEC 17025 by a mutually recognized Accr…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.25 mW |

DC 7.5 MUSIC DUAL LED
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter