
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ISED This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence- exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Requirement Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Scan the QR code on the right to access it, or visit help.fitbeing.net to browse. You can find the complete product manual in Fitbeing app at "Profile → User Guide". Product Manual Scan the QR code on the right to access or visit help.fitbeing.net for assistance. If you encounter any problems while using the product, you can access the "Profile → Help & Support" section in the Fitbeing app for assistance. Frequently Asked Questions Help and Guide · Do not replace the built-in battery yourself as it may pose a safety risk. · Avoid forcibly opening the watch case, as it may cause short circuits and overheating. · Keep the watch away from environments exceeding 60°C to prevent battery leakage or explosion. · While the product complies with IP68 waterproof standards, it is not recommended for activities such as bathing, diving, or water skiing that involve high temperatures, steam, or rapid water flow. Note that the waterproof performance may be compromised if the product structure is damaged. · Be aware that firmware upgrades can lead to interface and usage changes. For detailed information, please refer to the product's upgrade instructions. Precautions EN CW Watch R1 1.43" HD AMOLED 466 × 466 370 mAh Bluetooth 5.3 IP68 46.8mm × 46.8mm × 10.8mm Support Compass 0°C ~ 50°C iOS 13.0 and above, Android 9.0 and above Product Name Display Resolution Battery Capacity Wireless Connection Water resistance garde Body Dimension Geomagnetic sensor Working Temperature Compatible Operating Systems Key Specifications 2 1 For optimal data accuracy, please observe the following guidelines while wearing the watch: 1. Wear the watch at a position approximately two finger-widths from your wrist bone. 2. For comfort, adjust the band to allow a finger's width between it and your wrist. This ensures both contact and fit. Wear Your Watch ●It is advised to remove the watch for approximately one hour daily. If you experience discomfort or irritation like redness, tingling, or a burning sensation, take off the watch and rest your wrist. To maintain hygiene, regularly clean your watch and wrist, particularly after workouts and sweating. Avoid using hand soap, shower gel, dishwashing liquid, or cleaning wipes as they can cause skin irritation. Instead, use mild soap and fresh water to clean the band. ● Wear and Care EN Spring bar A Install band 1. Insert the metal pin at position "A" in the hole. 2. Push and hold the spring bar. 3. Press the band into the body and release the spring bar. 4. Pull the watch band to confirm the firm installation. Spring bar Remove band 1. Lift the spring bar from the groove. 2. Push and hold the spring bar. 3. Pull it out gently to remove the band. Change the Band Note: Make sure the USB charging plug is at the same side as the crown. Ensure to use a standard USB power source with an output of 5V⎓1A or above. Prior to charging, ensure to clean the charging contacts of the watch to eliminate any lingering sweat or moisture. To charge the watch, connect the charging cable to a USB power source. Attach the other end to the charging contact on the back of the watch. The watch will display a charging icon while it is being charged. Charge the Watch In the Fitbeing app, navigate to the Face Gallery page to pick up your preferred watch face. Install New Watch Faces EN When wearing the watch, it automatically measures health data such as heart rate, sleep, stress, and activity. You can also view and track this data in the application. Health Metrics Measurement For outdoor workouts, wait in an open area until the GPS connects. The blinking icon " " shows it's acquiring a location fix and w…
Text truncated - open the document above for the full version.
CreekWearableTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2023-12-13 FCCID:2BBYH-C1023 Ref.#1:AttestationStatementsPart2.911(d)(5)(i)Filing CreekWearableTechnologyCo.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorization pursuanttosection2.903oftheFCCrules. Ref.#2:AttestationStatementsPart2.911(d)(5)(ii)Filing CreekWearableTechnologyCo.,Ltd.certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing “covered”equipment. Applicant:CreekWearableTechnologyCo.,Ltd. Address:910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen,China ContactPerson:chenlong Tel.:075526648642 Email:[email protected] Sincerely, Signature:
CreekWearableTechnologyCo.,Ltd. Address:910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen,China Granteecode:2BBYH FRN:0033975350 FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BBYH-C1023 CreekWearableTechnologyCo.,Ltd..certifiesthat,asofthedateofthefilingofthe application,ClevelandInternationalTradeAgency.isourdesignatedU.S.agentforserviceof processfortheabovereferencedFCCID.CreekWearableTechnologyCo.,Ltd.acceptsto maintainanagentfornolessthanoneyearafterthegranteehasterminatedallmarketing andimportationortheconclusionofanyCommission-relatedproceedinginvolvingthe equipment. ClevelandInternationalTradeAgencyaccepts,asofthedateofthefilingoftheapplication, theobligationofthedesignatedU.S.agentforserviceofprocessfortheabovereferenced FCCID. DesignatedU.S.AgentInformation: Name:ClevelandInternationalTradeAgency Address:4033StClairAve,Cleveland,OH44103,USA ContactPerson:BeckyDeng Tel.:216-600-0606 Email:[email protected] FRN:0033401837 Sincerely, SignedonbehalfofShenzhenStar InstrumentCo.,Ltd. SignedonbehalfofClevelandInternational TradeAgency SignatureSignature Name: chenlong Name:BeckyDeng Title:ManagerTitle:Manager Date:December13,2023Date:December13,2023
CreekWearableTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:December13,2023 Subject;RequestforConfidentiality FCCID:2BBYH-C1023 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:chenlong Title:Manager
EffectiveDate:April2,2020QSF7.6.4-8–AgentAuthorizationLetterTemplatePage1of1 RevisionDate:Revision:0 CreekWearableTechnologyCo.,Ltd. Date:2023-12-13 ProductModelNumber:CWWatchR1 FCCID:2BBYH-C1023 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatORGANIZATION.isallowedtoforwardallinformationrelatedtotheapproval projecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscussanyissues concerningtheapprovalapplication.AnyandallactscarriedoutbyORGANIZATION.onour behalfshallhavethesameeffectasactsofourown. By:chenlong ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:075526648642 Onbehalfof:CreekWearableTechnologyCo.,Ltd.
TechnicalSpecification AntennaModeCW06Manufactured SHENZHENHENGXIANGTONGANTENNA TECNOLOGYCO.,LTD. Address 606,BuildingE,EnterpriseAviationTechnologyInnovationResearchandDevelopment IndustrialPark,No.1008,SongbaiRoad,SunshineCommunity,XiliStreet,Nanshan District,Shenzhen Size & Picture UINT:MM Antennamatching circuit BT:LOOP Band ModeNameFrequencyAntennaType AntennaMaxGain BTBluetooth 2400-2500Metalframe antenna -0.52dBi BT3-DPattenPlots BT:2400Mhz-2480Mhz PassiveTestForBT FreqEffiEffiGain (MHz)(%)(dB)(dBi) 240020.89-6.8-1.74 241021.14-6.75-1.67 242022.53-6.47-1.42 243022.82-6.42-1.31 244023.81-6.23-1.07 245024.14-6.17-0.92 246024.51-6.11-0.68 247025.22-5.98-0.76 248025.87-5.87-0.52 249026.81-5.72-0.44 250027.94-5.54-0.39
Externalphotos
R1 F C C I D : 2 B B Y H - C 1 0 2 3 I C : 3 0 9 0 3 - C 1 0 2 3 xxx-xxxxxx CW Watch R1 3mm
Internalphotos
ShenzhenHuaxiaTestingTechnologyCo.,Ltd 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20231102017E-03 Applicant: CreekWearableTechnologyCo.,Ltd. AddressofApplicant: 910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen EquipmentUnderTest(EUT): EUTName: SmartWatch ModelNo.: CWWatchR1 TestModelNo.: CWWatchR1 BrandName: N/A FCCID:2BBYH-C1023 Standards: 47CFRPart1.1307 47CFRPart2.1093 KDB447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2023-11-09 DateofTest: 2023-11-09to2023-11-20 DateofIssue:2023-12-13 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-03 Page:2of8 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20231102017E-03Rev.01 Initialreport 2023-12-13 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-03 Page:3of8 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 ..................................................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOFBLE...................................................................................................................................4 3.4GENERALDESCRIPTIONOFBT......................................................................................................................................4 4RFEXPOSUREEVALUATION.......................................................................................................................................5 4.1SAREVALUATIONFORPORTABLECONDITION...........................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.1.3SARExclusionEvaluationResult...................................................................................................................7 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-03 Page:4of8 3GeneralInformation 3.1ClientInformation Applicant: CreekWearableTechnologyCo.,Ltd. AddressofApplicant: 910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen Manufacturer: CreekWearableTechnologyCo.,Ltd. AddressofManufacturer: 910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen Factory: CreekWearableTechnologyCo.,Ltd. AddressofFactory: 910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen 3.2GeneralDescriptionofEUT ProductName: SmartWatch ModelNo.: CWWatchR1 TestModelNo.: CWWatchR1 TradeMark: N/A SoftwareVersion: V0.0.0.2 HardwareVersion: CW06-MTLMAINBOARDV1.1 PowerSupply: Li-ionbattery:DC3.85V370mAh,ChargebyDC5Vforadapter SimultaneousTransmissionSimultaneousTXissupportedandevaluatedinthisreport. SimultaneousTXisnotsupported. 3.3GeneralDescriptionofBLE OperationFrequency:2402MHz~2480MHz ModulationType:GFSK TransferRate:1Mbps/2Mbps NumberofChannel:40 ProductType:MobilePortable AntennaType: Metalframeantenna AntennaGain: -0.52dBi 3.4GeneralDescriptionofBT OperationFrequency:2402MHz~2480MHz ModulationType:GFSK,π/4DQPSK,8DPSK TransferRate:1Mbps/2Mbps/3Mbps NumberofChannel:79 ProductType:MobilePortable AntennaType: Metalframeantenna AntennaGain: -0.52dBi ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-03 Page:5of8 4RFExposureEvaluation 4.1 SAREvaluationforPortablecondition 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataasrepresentative ofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttestpositions(e.g.body, head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.Thistestreductionprocess providesfortheuseoftestdataforonespecificchannel,whilereferencingtothosedatafordemonstrating complianceinotherrequiredchannelsforeachtestpositionofanexposurecondition,withintheoperating modeofafrequencyband.Thisislimitedspecificallytowhenthereported1-gor10-gSARforthemid- bandorhighestoutputpowerchannelmeetsanyofthefollowingconditions. 4.1.2Limits SAR-basedthresholdsarederivedbasedonfrequency,power,andseparationdistanceoftheRF source.Theformuladefinesthethresholdsingeneralforeitheravailablemaximumtimeaveragedpoweror maximumtime-averagedERP,whicheverisgreater. IftheERPofadeviceisnoteasilydetermined,suchasforaportabledevicewithasmallform factor,…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. 1F.,BlockAofTongshengTechnologyBuilding,HuahuiRoad,DalangStreet,LonghuaDistrict, Shenzhen,China Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V05 ReportTemplateRevisionDate:2021-11-03 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20231102017E-01 Applicant: CreekWearableTechnologyCo.,Ltd. AddressofApplicant: 910,5Aofficebuilding,LongguangJiuzuan,LonghuaDistrict,Shenzhen EquipmentUnderTest(EUT): Product: SmartWatch ModelNo.: CWWatchR1 TestModelNo.: CWWatchR1 BrandName: N/A FCCID: 2BBYH-C1023 Standards:47CFRPart15,SubpartC DateofReceipt:2023-11-09 DateofTest: 2023-11-09to2023-11-20 DateofIssue:2023-12-13 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:2of91 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20231102017E-01Rev.01 Initialreport 2023-12-13 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:3of91 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement47CFRPart15.203/PASS ACPowerLineConducted Emission 47CFRPart15,SubpartCSection 15.207 ANSIC63.10-2013PASS ConductedPeakOutput Power 47CFRPart15.247ANSIC63.10-2013PASS 20dBOccupiedBandwidth47CFRPart15.247ANSIC63.10-2013PASS CarrierFrequencies Separation 47CFRPart15.247ANSIC63.10-2013PASS HoppingChannelNumber47CFRPart15.247ANSIC63.10-2013PASS DwellTime47CFRPart15.247ANSIC63.10-2013PASS PseudorandomFrequency HoppingSequence 47CFRPart15.247ANSIC63.10-2013PASS Band-edgeforRF ConductedEmissions 47CFRPart15.247ANSIC63.10-2013PASS RFConductedSpurious Emissions 47CFRPart15.247ANSIC63.10-2013PASS RadiatedSpurious emissions 47CFRPart15.209ANSIC63.10-2013PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15.205/15.209ANSIC63.10-2013PASS Remark: Thetestedsample(s)andthesampleinformationareprovidedbytheclient. Tx:InthiswholereportTx(ortx)meansTransmitter. Rx:InthiswholereportRx(orrx)meansReceiver. RF:InthiswholereportRFmeansRadiatedFrequency. CH:InthiswholereportCHmeanschannel. Volt:InthiswholereportVoltmeansVoltage. Temp:InthiswholereportTempmeansTemperature. Humid:InthiswholereportHumidmeanshumidity. Press:InthiswholereportPressmeansPressure. N/A:Inthiswholereportnotapplication ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:4of91 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.7TESTLOCATION........................................................................................................................................................10 4.8TESTFACILITY..........................................................................................................................................................10 4.9ABNORMALITIESFROMSTANDARDCONDITIONS......................................................................................................10 4.10OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.11EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUTPOWER.........................................................................................................................17 5.420DBOCCUPIEDBANDWIDTH...................................................................................................................................24 5.5CARRIERFREQUENCIESSEPARATION................................................................................…
Text truncated - open the document above for the full version.
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:61of91 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:62of91 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:63of91 2DH5_Ant1_2441_0~Reference 2DH5_Ant1_2441_30~1000 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:64of91 2DH5_Ant1_2441_1000~26500 2DH5_Ant1_2480_0~Reference ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:65of91 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:66of91 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:67of91 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:68of91 3DH5_Ant1_2441_30~1000 3DH5_Ant1_2441_1000~26500 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:69of91 3DH5_Ant1_2480_0~Reference 3DH5_Ant1_2480_30~1000 ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:70of91 3DH5_Ant1_2480_1000~26500 Remark: Pretest9kHzto25GHz,findthehighestpointwhentesting,soonlytheworstdatawereshowninthetest report.PerFCCPart15.33(a)and15.31(o),Theamplitudeofspuriousemissionsfromintentionalradiators whichareattenuatedmorethan20dBbelowthepermissiblevalueneednotbereportedunlessspecifically requiredelsewhereinthispart. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:71of91 5.10 OtherrequirementsFrequencyHoppingSpreadSpectrumSystem TestRequirement:47CFRPart15CSection15.247(a)(1),(h)requirement: Thesystemshallhoptochannelfrequenciesthatareselectedatthesystemhopping ratefromaPseudorandomorderedlistofhoppingfrequencies.Eachfrequencymustbeusedequally ontheaveragebyeachtransmitter.Thesystemreceiversshallhaveinputbandwidthsthatmatchthe hoppingchannelbandwidthsoftheircorrespondingtransmittersandshallshiftfrequenciesin synchronizationwiththetransmittedsignals. Frequencyhoppingspreadspectrumsystemsarenotrequiredtoemployallavailablehopping channelsduringeachtransmission.However,thesystem,consistingofboththetransmitterandthe receiver,mustbedesignedtocomplywithalloftheregulationsinthissectionshouldthe transmitterbepresentedwithacontinuousdata(orinformation)stream.Inaddition,asystem employingshorttransmissionburstsmustcomplywiththedefinitionofafrequencyhoppingsystem andmustdistributeitstransmissionsovertheminimumnumberofhoppingchannelsspecifiedin thissection. Theincorporationofintelligencewithinafrequencyhoppingspreadspectrumsystemthatpermits thesystemtorecognizeotheruserswithinthespectrumbandsothatitindividuallyand independentlychoosesandadaptsitshopsetstoavoidhoppingonoccupiedchannelsispermitted. Thecoordinationoffrequencyhoppingsystemsinanyothermannerfortheexpresspurposeof avoidingthesimultaneousoccupancyofindividualhoppingfrequenciesbymultipletransmittersis notpermitted. Complianceforsection15.247(a)(1) AccordingtoBluetoothCoreSpecification,thepseudorandomsequencemaybegeneratedinanine- stageshiftregisterwhose5thand9thstage outputsareaddedinamodulo-twoadditionstage.Andtheresultisfedbacktotheinputofthefirst stage.ThesequencebeginswiththefirstONEof9consecutiveONEs;i.e.theshiftregisterisinitialized withnineones. •Numberofshiftregisterstages:9 •Lengthofpseudo-randomsequence:2 9 -1=511bits •Longestsequenceofzeros:8(non-invertedsignal) AnexampleofPseudorandomFrequencyHoppingSequenceasfollow: Eachfrequencyusedequallyontheaveragebyeachtransmitter. AccordingtoBluetoothCoreSpecification,BluetoothreceiversaredesignedtohaveinputandIF bandwidthsthatmatchthehoppingchannelbandwidthsofanyBluetoothtransmittersandshift frequenciesinsynchronizationwiththetransmittedsignals. Complianceforsection15.247(g) AccordingtoBluetoothCoreSpecification,theBluetoothsystemtransmitsthepacketwiththe pseudorandomhoppingfrequencywithacontinuousdataandtheshortbursttransmissionfromthe Bluetoothsystemisalsotransmittedunderthefrequencyhoppingsystemwiththepseudorandom hoppingfrequencysystem. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:72of91 Complianceforsection15.247(h) AccordingtoBluetoothCorespecification,theBluetoothsystemincorporateswithanadaptive systemtodetectotheruserwithinthespectrumbandsothatitindividuallyandindependentlyto avoidhoppingontheoccupiedchannels. AccordingtotheBluetoothCorespecification,theBluetoothsystemisdesignednothavetheability tocoordinatedwithotherFHSSSysteminanefforttoavoidthesimultaneousoccupancyofindividual hoppingfrequenciesbymultipletransmitter. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ20231102017E-01 Page:73of91 5.11 RadiatedSpuriousEmission&Restrictedbands TestRequirement:47CFRPart15CSection15.209and15.205 TestMethod:ANSIC63.10:2013 TestSite:MeasurementDistance:3m(Semi-AnechoicChamber) ReceiverSetup: FrequencyDetectorRBWVBWRemark 0.009MHz-0.090MHzPeak10kHz30kHzPeak 0.009MHz-0.090MHzAverage10kHz30kHzAverage 0.090MHz-0.110MHzQuasi-peak10kHz30kHzQuasi-peak 0.110MHz-0.490MHzPeak10kHz30kHzPeak 0.110MHz-0.490MHzAverage10kHz30kHzAverage 0.490MHz-30MHzQuasi-peak10kHz30kHzQuasi-peak 30MHz-1GHzPeak120kHz300kHzPeak Above1GHz Peak1MHz3MHzPeak Peak1MHz10HzAverage Limit: Frequency Fieldstrength (microvolt/meter) Limit (dBuV/m) Remark Measurement distance(m) 0.009MHz-0.490MHz2400/F(kHz)--300 0.490MHz-1.705MHz24000/F(kHz)--30 1.705MHz-30MHz30--30 30MHz-88MHz10040.0Quasi-peak3 88MHz-216MHz15043.5Quasi-peak3 216MHz-960MHz20046.0Quasi-peak3 960MHz-1GHz50054.0Quasi-peak3 Above1GHz50054.0Average3 Note:15.35(b),Unlessotherwisespecified,thelimitonpeakradiofrequency emissionsis20dBabovethemaximumpermittedaverageemissionlimit applicabletotheequipmentundertest.Thispeaklimitappliestothetotal peakemissionlevelradiatedbythedevice. ShenzhenHuaxiaTestingTechnologyCo.,Ltd. ReportNo.:CQASZ2023…
Text truncated - open the document above for the full version.
1Photographs-EUTTestSetup 1.1RadiatedEmission 9KHz~30MHz: 30MHz~1GHz: Above1GHz: 1.2ConductedEmission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 900.00 µW |

Smart Watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Watch
Equipment Class
DTS - Digital Transmission System
Smart Watch
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter