2BCMY-TVE1065MTablet

Techvision Intelligent Technology Co., Ltd.
Tablet - FCC ID 2BCMY-TVE1065M - Techvision Intelligent Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 11, 2024
Application Purpose
Original Equipment
Date of Application
Mar 11, 2024
Equipment Note
Tablet
Frequency Range
2412.00000000 - 2462.00000000
Company
Techvision Intelligent Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LincPlusT4 Tablet UserManual BrandLincPlus Model LincPlusT4 CPU MediaTekG99,Dual-CoreA762.2G+Hexa-CoreCA552.0G OS Android TM 13 Memory8GLpDDR4 Storage 128GUFS Display 10.95inch,2000x1200,IPS Touch Incell,10piont CaseFullMetal Battery8000mAH/3.8V Camera Front8M,Rear13M,Flashlight Wi-Fi 2.4G/5G802.11a/b/g/n/ac BluetoothBluetooth5.2 I/O USBportUSBTypeC,USBdataandaudioout SDport MicroSD Button Power,VOL-,VOL+ SensorG-sensor/L-Sensor/P-Sensor/Compass/Gyroscope GNSS GPS/BeiDou/Glonass Microphones2xMIC Speaker4xBoxSpeaker Charger 20W,SupportPD/PE+quickcharger Dimension256.9x161.5x7.2mm Weight Tablet519g ContainsTablet,ChargerCable,Adapter,Ejectionpin,Magnetic holder,USI2.0handwritingpen,Manual ① Powerbutton ② Speakers ③ Volumeup/down ④MicroSD⑤Frontcamera⑥Touchkeyboardretainer ⑦ Touchkeyboardconnector ⑧ USBport ⑨ FlashLight ⑩ Rearcamera Dearcustomer; LincPluswouldliketothankyouforyourrecentpurchase.Wetrulycareabout youruserexperience. Ifyouhaveanyquestionsorconcerns,pleasefeelfreetocontactus.Our customersupportteamisstandingbytoassistyou. Bestregards LincPlusServiceTeam CETPRODUCTSERVICELTD.(forauthoritiesonly) BeaconHouseStokenchurchBusinessPark, IbstoneRd,Stokenchurch HighWycombeHP143FEUK CETPRODUCTSERVICESP.ZO.O.(forauthoritiesonly) Ul.Dluga33102Zgierz PostalCode:95-100Polen Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe followingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. AndroidisatrademarkofGoogleLLC FCCStatement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothe following twoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass Bdigitaldevice,pursuanttopart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation. Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,if notinstalledandusedinaccordancewiththeinstructions, maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception, whichcanbedeterminedbyturningtheequipmentoffandon, theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures:Reorientorrelocatethereceivingantenna. .Increasetheseparationbetweentheequipmentandreceiver. .Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected. .Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenotexplicitlyapprovedby manufacturercouldvoidyourauthoritytooperatethisequipment.RFExposure Information ThedevicewasevaluatedtomeetgeneralRFexposurerequirements.This equipmentshouldbeinstalledandusedwithaminimumdistanceof0mm betweentheradiatorandyourbody. Add:12F,BuildingA4,NanshanZhiyuan,No.1001,XueyuanAvenue,XiliTown,Nanshan District,Shenzhen,P.R.China E-mail : [email protected]://www.lincplustech.com Specific Absorption Rate (SAR) information: This Tablet meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body- worn accessories that do not meet these requirements may not comply with RF exposure FCC RF Exposure Information and Statement The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: LincPlus T4 (FCC ID: 2BCMY-TVE1065M) has also been tested against this SAR limit. The highest SAR value reported under this standard when properly worn on the body is 0.726W/ kg. This device was tested for typical body-worn operations with the back of the Tablet kept 0mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 0mm separation distance between the user's body and the back of the Tablet. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. requirements and should be avoided. Use only the supplied or an approved antenna.

Attestation Statements

Techvision Intelligent Technology Co., Ltd. 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-3-6 To whom it may concern: We, Techvision Intelligent Technology Co., Ltd., hereby certify that the equipment for which authorization is sought (FCC ID: 2BCMY-TVE1065M) is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Shark. Tang DQE Engineer Techvision Intelligent Technology Co., Ltd. 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2024-3-6> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2BCMY-TVE1065M LincPlus T4 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Shark. Tang/DQE Engineer Company: Techvision Intelligent Technology Co., Ltd. Address: 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Phone: 0755-36995508 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Techvision Intelligent Technology Co., Ltd. 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Date: 2024-3-6 FCC ID: 2BCMY-TVE1065M Model Number: LincPlus T4 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, Techvision Intelligent Technology Co., Ltd., declare that this EUT (FCC ID: 2BCMY-TVE1065M) doesn’t have Ad Hoc mode function on “non-US/Canada frequencies”. In addition. The frequency selection feature is disabled by firmware for devices marked to the US/Canada. For DTS part of this device, only channels 1-11 will be used in North America, Country code selection is disabled. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Name/Title: Shark. Tang/DQE Engineer Company: Techvision Intelligent Technology Co., Ltd. Address: 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Phone: 0755-36995508 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Techvision Intelligent Technology Co., Ltd. 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2024-3-6 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2BCMY-TVE1065M including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Shark. Tang/DQE Engineer Company: Techvision Intelligent Technology Co., Ltd. Address: 12/F, A4, Nanshan Zhiyuan, 1001 Xueyuan Avenue, Nanshan Dist.Shenzhen China Phone: 0755-36995508 Fax: N/A E-Mail: [email protected]

External Photos

Page1of5FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. ExternalPhotos Photo1 Photo2 Page2of5FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo3 Photo4 Page3of5FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo5 Photo6 Page4of5FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo7 Photo8 Page5of5FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo9 Photo10 ------End------

ID Label/Location Info

Label FCCID:2BCMY-TVE1065M ProductName:Tablet ModelNo.:LincPlusT4

Internal Photos

Page1of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. InternalPhotos Photo1 Photo2 Page2of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo3 Photo4 Page3of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo5 Photo6 Page4of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo7 Photo8 Antenna Page5of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo9 Photo10 Page6of6FCCID:2BCMY-TVE1065M DongguanYaxu(AiT)TechnologyLimited No.22,Jinqianling3rdStreet,Jitigang, Huangjiang,Dongguan,Guangdong,China. Photo11 Photo12 ------End------

RF Exposure Info

Page 1 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix C Calibration certificate 1. Dipole D2450V2-SN 808(2023-10-23) D5GHzV2-SN 1046(2023-10-23) 2. DAE DAE3-SN 373(2024-01-03) 3. Probe EX3DV4-SN 3805(2023-11-23) Page 2 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 15 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 16 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 17 of 27 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Str…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A Detailed System Check Results 1. System Performance Check System Performance Check 2450 MHz Head System Performance Check 5250 MHz Head System Performance Check 5600 MHz Head System Performance Check 5750 MHz Head Page 2 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/23 Test Laboratory: LCS-SAR Lab System Check 2450 MHz DUT: D2450V2; Type: D2450V2; Serial: 808 Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2450 MHz; σ = 1.785 S/m; ε r = 39.365; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (4x8x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 17.0 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 88.94 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 26.1 W/kg SAR(1 g) = 12.5 W/kg; SAR(10 g) = 5.75 W/kg Maximum value of SAR (measured) = 19.3 W/kg 0 dB = 19.3 W/kg = 12.86 dBW/kg Page 3 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/26 Test Laboratory: LCS-SAR Lab System Check 5250 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5250 MHz; σ = 4.656 S/m; ε r = 36.18; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 17.3 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 50.65 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 28.9 W/kg SAR(1 g) = 7.65 W/kg; SAR(10 g) = 2.24 W/kg Maximum value of SAR (measured) = 19.3 W/kg 0 dB = 19.3 W/kg = 12.86 dBW/kg Page 4 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/27 Test Laboratory: LCS-SAR Lab System Check 5600MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5600 MHz; σ = 5.093 S/m; ε r = 35.113; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 20.4 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 69.62 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 35.8 W/kg SAR(1 g) = 8.25 W/kg; SAR(10 g) = 2.29 W/kg Maximum value of SAR (measured) = 21.6 W/kg 0 dB = 20.4 W/kg = 13.10 dBW/kg a Page 5 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/27 Test Laboratory: LCS-SAR Lab System Check 5750 MHz DUT: D5GHzV2; Type: D5GHzV2; Serial: 1046 Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5750 MHz; σ = 5.184 S/m; ε r = 35.502; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.88, 4.88, 4.88); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 19.2 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 62.85 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 33.2 W/kg SAR(1 g) = 8.04 W/kg; SAR(10 g) = 2.22 W/kg Maximum value o…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 6 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B Detailed Test Results 1. WIFI WIFI 2.4GHz for Body WIFI 5.2GHz for Body WIFI 5.3GHz for Body WIFI 5.5GHz for Body WIFI 5.8GHz for Body Page 2 of 6 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/23 Test Laboratory: LCS-SAR Lab WIFI 2.4G 802.11b 11CH Rear side 0mm DUT: LincPlus T4; Type: Tablet; Serial: A240124019-1 Communication System: UID 0, WIFI 2.4GHz (0); Frequency: 2462 MHz;Duty Cycle: 1:1 Medium parameters used: f = 2462 MHz; σ = 1.814 S/m; ε r = 39.948; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(7.42, 7.42, 7.42); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (9x14x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 1.04 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 2.921 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 1.69 W/kg SAR(1 g) = 0.603 W/kg; SAR(10 g) = 0.229 W/kg Maximum value of SAR (measured) = 1.14 W/kg 0 dB = 1.14 W/kg = 0.57 dBW/kg Page 3 of 6 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/26 Test Laboratory: LCS-SAR Lab WIFI 5.2G 802.11a 36CH Rear side 0mm DUT: LincPlus T4; Type: Tablet; Serial: A240124019-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5180 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5180 MHz; σ = 4.674 S/m; ε r = 35.587; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (11x16x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.542 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 1.65 W/kg SAR(1 g) = 0.346 W/kg; SAR(10 g) = 0.087 W/kg Maximum value of SAR (measured) = 0.746 W/kg 0 dB = 0.746 W/kg = -1.27 dBW/kg a Page 4 of 6 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/26 Test Laboratory: LCS-SAR Lab WIFI 5.3G 802.11a 52CH Rear side 0mm DUT: LincPlus T4; Type: Tablet; Serial: A240124019-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5260 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5260 MHz; σ = 4.765 S/m; ε r = 36.229; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(5.38, 5.38, 5.38); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (11x16x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.559 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.5170 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 1.82 W/kg SAR(1 g) = 0.359 W/kg; SAR(10 g) = 0.088 W/kg Maximum value of SAR (measured) = 0.791 W/kg 0 dB = 0.791 W/kg = -1.02 dBW/kg Page 5 of 6 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Date: 2024/2/27 Test Laboratory: LCS-SAR Lab WIFI 5.5G 802.11a 140CH Rear side 0mm DUT: LincPlus T4; Type: Tablet; Serial: A240124019-1 Communication System: UID 0, WIFI 5GHz (0); Frequency: 5700 MHz;Duty Cycle: 1:1 Medium parameters used: f = 5700 MHz; σ = 5.149 S/m; ε r = 35.718; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY Configuration:  Probe: EX3DV4 - SN3805; ConvF(4.75, 4.75, 4.75); Calibrated: 2023/11/23;  Sensor-Surface: 2mm (Mechanical Surface Detection)  Electronics: DAE3 Sn373; Calibrated: 2024/1/3  Phantom: ELI v5.0; Type: ELI; Serial: 2010  DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Unnamed procedure/Area Scan (11x16x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.839 W/kg Configuration/Unnamed procedure/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 2.07 …

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 5 FCC ID: 2BCMY-TVE1065M Report No.: LCSA01244025E Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 07…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shark. Tang(DQE Engineer)
[email protected]0755-36995508Fax: N/A

Test Firm

Dongguan Yaxu (AiT) Technology LimitedCoin Tang
[email protected]+86 0769-82020499-21

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz34.80 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. For body worn operation, this Tablet has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the Tablet a minimum of 0 mm from the body.Use of other accessories may not ensure compliance with FCC RF exposure guidelines.End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR for body-worn accessory is 0.69 W/kg.

Other Applications from Techvision Intelligent Technology Co., Ltd.

Creator tablet - FCC ID 2BCMY-TVE1327X - Techvision Intelligent Technology Co., Ltd.
2BCMY-TVE1327X

Creator tablet

Dec 14, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
NAS - FCC ID 2BCMY-TVI8310X - Techvision Intelligent Technology Co., Ltd.
2BCMY-TVI8310X

NAS

Oct 25, 2023

Equipment Class

DTS - Digital Transmission System