Coil Pro What’s in the box Rokoko Coil Pro 01 Power supply USB C to A cable The included power supply is designed for use with the Coil Pro specifically. Do not use it to charge or provide power for any other devices such as phones, laptops or other electronic equipment. Note of caution Adapters for EU, UK, Australia and US How to set up the Coil Pro Rokoko Studio1. Download and install Rokoko Studio by going to rokoko.com/studio Position your Coil Pro2. Rokoko Coil Pro can be placed in the room in multiple ways. For example by directly putting it on a table, floor or other flat, plane surface. Coil Pro can also be mounted on a tripod or upside-down from the ceiling via the thread mount in the foot. 02 Ferro-metals such as iron will affect the electromagnetic field emitted by the Coil Pro. Therefore, for optimal capture performance, Connect your Coil Pro to the computer 3. Use the USB C to A cable to connect the Coil Pro to the computer: The C end connects to Coil Pro and the A end connects to the computer. The USB C connection on Coil Pro is found on the bottom of Coil Pro. avoid placing the Coil Pro close to ferro-metals and secure uninterrupted capture space. The Coil Pro is not producing a field and is thereby not functional for recordings in this PC-connected state. Power up your Coil Pro5. Locate the included power supply and connect it to your Coil Pro. The same USB-C port/slot that was used to attach to the PC can now be used to power up the device into an active state for recordings. If you don’t see any prompts to update when your devices are connected, it means you have the latest firmware already. Be sure to use the specific power supply included with the Coil Pro. Also, do not use this included power supply to power other devices than Coil Pro. Update firmware4. Open Rokoko Studio and check for new firmware updates. We always recommend updating to the latest firmware version. Pairing Coil Pro and Smartgloves6. When Smartgloves are powered up, they will automatically detect and pair themselves with Coil Pro in Studio. Make sure that Smartgloves are running the latest firmware version. For instructions on firmware update for Smartgloves, please refer to the quick start guide for Smartgloves. Safety tested, production monitored This mark is awarded exclusively by TÜV SÜD Product Service. It clearly indicates that safety inspections are performed and production sites are monitored regularly. This product has been tested thoroughly according to national standards in different regions globally. The following summarises the minimum recommended safe distance for regular equipment operation, according to said standards. Note of caution For safety reasons, please remove the power plug from the wall to power off Coil Pro, when Coil Pro is not in use, or when moving / placing the product. EU/UK: 51 cmUSA: 20 cmCanada: 20 cm Onwards to motion capture Create a scene 1. Setup your motion capture scene with the relevant Actors and pair your Rokoko gear to them. Calibrate 2. Once paired, be sure to calibrate all actors. It is good practice to do so once in a while in-between recordings as well. Record or livestream 3. When everything is set up and calibrated, start recording and see your motion capture in real-time. You can also instead choose 03 Clean4. Use our built-in filters and editing tools to clean up your mocap recordings and have it looking just right. Export5. When you’re done with your recordings, you can batch export using a range of export settings. to just livestream the data to another application like Blender, Unity, Unreal or Maya. Head over to rokoko.co/coil Want to know more? Compliance information 04 EU Compliance Information Hereby, Rokoko Electronics ApS, declares that this device is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at rokoko.com/products/coil-pro UK Compliance Information Hereby, Rokoko Electronics ApS, declares that this device is in compliance with Radio Equipment Regulations 2017. The full text of the UK declaration of conformity is available at rokoko.com/products/coil-pro Output power: WPT 21 KHz ~ 23 KHz: 55.69 dBuA/m at 10m Caution: Use only the adapter supplied with the device. Adapter shall be installed near the equipment. UK importer information is located on our website and product packaging. Waste Electrical and Electronic Equipment (WEEE) This symbol means that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities. Proper recycling of your product will protect human health and the environment. US Compliance Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorien…
Text truncated - open the document above for the full version.
5RNRNR(OHFWURQLFV$S6 6DQNW*HUWUXGV6WUDHGH&RSHQKDJHQ'HQPDUN 7HO )HGHUDO&RPPXQLFDWLRQV&RPPLVVLRQ 2DNODQG0LOOV5RDG &ROXPELD0' 'DWH6HSWHPEHU 6XEMHFW&HUWLILFDWLRQVFRQFHUQLQJ³FRYHUHG ́HTXLSPHQWSXUVXDQWWR3DUW G L DQG LL 7RZKRPLWPD\FRQFHUQ 5RNRNR(OHFWURQLFV$S6 ³WKHDSSOLFDQW ́ FHUWLILHVWKDWWKHHTXLSPHQW>)&&,'%&<5..&3@IRUZKLFK DXWKRUL]DWLRQLVVRXJKWLVQRW³FRYHUHG ́HTXLSPHQWSURKLELWHGIURPUHFHLYLQJDQHTXLSPHQWDXWKRUL]DWLRQ SXUVXDQWWRVHFWLRQRIWKH)&&UXOHV 5RNRNR(OHFWURQLFV$S6 ³WKHDSSOLFDQW ́ FHUWLILHVWKDWDVRIWKHGDWHRIWKHILOLQJRIWKHDSSOLFDWLRQWKH DSSOLFDQW>LVQRW@LGHQWLILHGRQWKH&RYHUHG/LVW DVDVSHFLILFDOO\QDPHGHQWLW\RUDQ\RILWVVXEVLGLDULHVRU DIILOLDWHV DVDQHQWLW\SURGXFLQJ³FRYHUHG ́HTXLSPHQW 6LQFHUHO\ -DNRE%DOVOHY BBBBBBBBBBBBBBBBBBBBBBBB 1DPH.HQGUD%DQQLVWHU 7LWOH93RI+DUGZDUH'HYHORSPHQW (PDLONHQGUDEDQQLVWHU#URNRNRFRP
5RNRNR(OHFWURQLFV$S6 6DQNW*HUWUXGV6WUDHGH&RSHQKDJHQ'HQPDUN 7HO )HGHUDO&RPPXQLFDWLRQV&RPPLVVLRQ 2DNODQG0LOOV5RDG &ROXPELD0' 'DWH6HSWHPEHU 6XEMHFW&HUWLILFDWLRQVFRQFHUQLQJ³FRYHUHG ́HTXLSPHQWSXUVXDQWWR3DUW G L DQG LL 7RZKRPLWPD\FRQFHUQ 5RNRNR(OHFWURQLFV$S6 ³WKHDSSOLFDQW ́ FHUWLILHVWKDWWKHHTXLSPHQW>)&&,'%&<5..&3@IRUZKLFK DXWKRUL]DWLRQLVVRXJKWLVQRW³FRYHUHG ́HTXLSPHQWSURKLELWHGIURPUHFHLYLQJDQHTXLSPHQWDXWKRUL]DWLRQ SXUVXDQWWRVHFWLRQRIWKH)&&UXOHV 5RNRNR(OHFWURQLFV$S6 ³WKHDSSOLFDQW ́ FHUWLILHVWKDWDVRIWKHGDWHRIWKHILOLQJRIWKHDSSOLFDWLRQWKH DSSOLFDQW>LVQRW@LGHQWLILHGRQWKH&RYHUHG/LVW DVDVSHFLILFDOO\QDPHGHQWLW\RUDQ\RILWVVXEVLGLDULHVRU DIILOLDWHV DVDQHQWLW\SURGXFLQJ³FRYHUHG ́HTXLSPHQW 6LQFHUHO\ -DNRE%DOVOHY BBBBBBBBBBBBBBBBBBBBBBBB 1DPH.HQGUD%DQQLVWHU 7LWOH93RI+DUGZDUH'HYHORSPHQW (PDLONHQGUDEDQQLVWHU#URNRNRFRP
Rokoko Electronics ApS Sankt Gertruds Straede 10 Copenhagen Denmark 1129 Tel: 29709615 Date: October 13, 2023 FCC Laboratory 7435 Oakland Mills Rd Columbia MD 21046 Subject: Request for Confidentiality FCC ID: 2BCY2-RKKCP01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following documents from public disclosure indefinitely. l Schematic Diagram l Block Diagram l Operational Description l Parts List Above mentioned documents which contain detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we are requesting the Commission to withhold the following documents for 180 days after the grant of equipment authorization is issued: l External Photos l Internal Photos l Test Setup Photos l User Manual It is our understanding that all measurement test reports, FCC ID label format cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, _______________________ Kendra Bannister VP of Hardware Development [email protected]
5RNRNR(OHFWURQLFV$S6 6DQNW*HUWUXGV6WU GH &RSHQKDJHQ'HQPDUN 7HO 5H$WWHVWDWLRQ6LJQDWXUH3HUPLVVLRQ 7RZKRPLWPD\FRQFHUQ ,KHUHE\JUDQWSHUPLVVLRQIRU&(2DQG'LUHFWRURI5RNRNRWRVLJQWKH86 -DNRE%DOVOHY $JHQW$WWHVWDWLRQOHWWHU 6XEMHFW&HUWLILFDWLRQGHVLJQDWLQJD86DJDLQVWIRUVHUYLFHRISURFHVVSXUVXDQWWR 3DUW G %HVWUHJDUGV .HQGUD%DQQLVWHU 93RI+DUGZDUH'HYHORSPHQW )&&*UDQWHHIRU5RNRNR(OHFWURQLFV$S6
PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 1 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 1. External Photograph of EUT Brand Name: Rokoko / Model Name: RKK-CP-01 / Marketing Name: Coil Pro PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 2 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 3 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 4 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 5 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 6 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 720510 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 7 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 2. Photograph of Accessory Brand Name: Rokoko / Model Name: RKK-CP-01 / Marketing Name: Coil Pro Specification of Accessory AC Adapter Brand Name FRIWO Gerätebau GmbH Model Name FW8030/12 USB Cable Brand Name Rokoko Model Name 6011008 SG USB A/C 90 grader 1500mm Remark: For accessories equipped with this EUT, please refer to the following photos. PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 8 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 720510 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 9 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 AC Adapter
Model: RKK-CP-01 SN: XXXXXXXXXXXX FCC ID: 2BCY2-RKKCP01 CAN ICES-003(B)/NMB-003(B) HVIN: RKK-CP-01 IC: 31264-RKKCP01 RISK OF ELECTRIC SHOCK DO NOT OPEN 12V 1.7A CAUTION!
Device Bottom Label
PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 10 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 3. Internal Photograph of EUT Brand Name: Rokoko / Model Name: RKK-CP-01 / Marketing Name: Coil Pro PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 11 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 12 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 13 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 14 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 15 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 16 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 17 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 18 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 19 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 20 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 21 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 22 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 720510 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 23 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 24 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 25 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 26 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 27 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 28 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 29 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 30 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 31 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 32 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 33 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 34 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 35 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 36 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 37 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 38 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 39 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 40 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01
PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 41 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 42 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 43 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 44 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 45 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 46 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 47 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 48 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 49 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 50 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 51 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 52 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 53 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 54 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 55 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 56 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 57 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 58 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 59 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 60 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 61 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 PHOTOGRAPHS OF EUT Report No.: EP370328 TEL : 886-3-327-3456 Page Number : 62 of 62 FAX : 886-3-328-4978 Issue Date : Dec. 11, 2023 Report Version : 01 ─────THE END────
SPORTON INTERNATIONAL INC. Page Number : 1 of 5 TEL : 886-3-327-3456 Report Issued Date : Dec. 12, 2023 FAX : 886-3-328-4978 FCC RF Exposure Report Report No. : FA370328 RF Exposure Report FCC ID : 2BCY2-RKKCP01 Equipment : Coil Pro Brand Name : Rokoko Model Name : RKK-CP-01 Applicant : Rokoko Electronics ApS Sankt Gertruds Stræ de 10, 1129 Kø benhavn Manufacturer : Rokoko Electronics ApS Sankt Gertruds Stræ de 10, 1129 Kø benhavn Standard : FCC CFR 47 part 2.1091 The product was received on Sep. 20, 2023 and testing was started from Oct. 11, 2023 and completed on Oct. 11, 2023. We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample provide by manufacturer and the test data has been evaluated in accordance with the test procedures given in 47 CFR Part 2.1091 and FCC KDB 680106 D01v03r01 and has been pass the FCC requirement. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. Sporton International Inc. EMC & Wireless Communications Laboratory No.52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan Approved by: Cona Huang / Deputy Manager SPORTON INTERNATIONAL INC. Page Number : 2 of 5 TEL : 886-3-327-3456 Report Issued Date : Dec. 12, 2023 FAX : 886-3-328-4978 FCC RF Exposure Report Report No. : FA370328 Table of Contents 1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. RF EXPOSURE LIMIT ................................................................................................................................. 4 4. RF EXPOSURE EVALUATION ................................................................................................................... 5 Appendix A. Test Setup Photo SPORTON INTERNATIONAL INC. Page Number : 3 of 5 TEL : 886-3-327-3456 Report Issued Date : Dec. 12, 2023 FAX : 886-3-328-4978 FCC RF Exposure Report Report No. : FA370328 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA370328 Rev. 01 Initial issue of report Dec. 12, 2023 SPORTON INTERNATIONAL INC. Page Number : 4 of 5 TEL : 886-3-327-3456 Report Issued Date : Dec. 12, 2023 FAX : 886-3-328-4978 FCC RF Exposure Report Report No. : FA370328 1. Description of Equipment Under Test (EUT) Product Feature & Specification EUT Type Coil Pro Brand Name Rokoko Model Name RKK-CP-01 FCC ID 2BCY2-RKKCP01 Frequency Range 21 KHz ~ 23 KHz HW Version RKK-CP-01 2. RF Exposure Limit According to KDB 447498 D04 Table1, when the device operate frequency is ≤ 100 kHz, the RF Exposure limit can be reference to KDB 680106 section3)a)2). Evaluation of RF Exposure test data for determining compliance of systems (both portable and not) operating at frequencies below 100 kHz is provided on a case-bycase basis following a KDB inquiry. In these situations, a device may be considered acceptable when supporting data from measurements and/or numerical simulations show that, for all the positions of space relevant for the body exposure, the external (unperturbed) temporal peak field strengths do not exceed the following reference levels: - 83 V/m for the electric field - 90 A/m for the magnetic field 3. Measurement Equipment Instrument Manufacturer Model No. Serial No. Freq. Range Last Cal. Due Date Electric and Magnetic field Probe-Analyzer Narda S.T.S / PMM EHP 200AC 170WX80309 3KHz~30MHz Nov. 03, 2022 Nov. 02, 2023 SPORTON INTERNATIONAL INC. Page Number : 5 of 5 TEL : 886-3-327-3456 Report Issued Date : Dec. 12, 2023 FAX : 886-3-328-4978 FCC RF Exposure Report Report No. : FA370328 4. RF Exposure Evaluation General Note: 1. The device generates a magnetic field with known strength and is used in a motion capture global positioning application, where a receiver device can determine positioning within the field by fusing sensor EMF + IMU data. 2. When the product is on, the receiver will measure user movement within the field. 3. When the user is too close to the product (approximately 50-70cm), the performance of the sensor fusion is poor, as the EME sensor data becomes saturated. We therefore recommend in regular use for our application, that the user remains at least this distance from the product during regular operation for optimal performance reasons. 4. The product function (generate the necessary field for receiver measurement) at more than 20 cm from the human body, and as mentioned above, this recommended for optimal performance. The device is powered using a AC<>DC power adapter, and is stationary during operation to maintain a stable origin for global positioning. Therefore, RF exposure evaluation is tested at 20 cm. Position E-Field Measurement (V/m) limit Result Front Left Right Top Bottom Test Dis.(mm) 200 200 200 200 200 Adapter 41.496 41.254 34.296 36.454 40.542 83 Pass Position H-Field Measurement (A/m) limit Result Front Left Right Top Bottom Test Dis.(mm) 200 200 200 200 200 Adapter 33.079 34.159 33.061 36.232 32.923 90 Pass Conclusion: The measurement E/H-Field resuls for for all the positions of space relevant for the body exposure, the external (unperturbed) temporal peak field strengths is compliance with: - 83 V/m for the electric field - 90 A/m for the magnetic field
TEL : 886-3-327-3456 Page Number : 1 of 14 FAX : 886-3-328-4978 Issue Date : Feb. 07, 2024 Report Template No.: BU5-FR15CNFMI Version 2.1 Report Version : 03 FCC RADIO TEST REPORT Report No. : FR370328 FCC RADIO TEST REPORT FCC ID : 2BCY2-RKKCP01 Equipment : Coil Pro Brand Name : Rokoko Model Name : RKK-CP-01 Marketing Name : Coil Pro Applicant : Rokoko Electronics ApS Sankt Gertruds Stræ de 10, 1129 Kø benhavn Manufacturer : Rokoko Electronics ApS Sankt Gertruds Stræ de 10, 1129 Kø benhavn Standard : FCC Part 15 Subpart C §15.209 The product was received on Sep. 12, 2023 and testing was performed from Sep. 20, 2023 to Dec. 05, 2023. We, Sporton International Inc. EMC & Wireless Communications Laboratory, would like to declare that the TAF ISO 17025 excludes the Radiated Emission Test accreditation, and the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. EMC & Wireless Communications Laboratory No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) TEL : 886-3-327-3456 Page Number : 2 of 14 FAX : 886-3-328-4978 Issue Date : Feb. 07, 2024 Report Template No.: BU5-FR15CNFMI Version 2.1 Report Version : 03 FCC RADIO TEST REPORT Report No. : FR370328 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1. General Description ................................................................................................................................... 5 1.1. Feature of Equipment Under Test ..................................................................................................... 5 1.2. Modification of EUT ........................................................................................................................... 5 1.3. Test Location ..................................................................................................................................... 5 1.4. Applied Standards ............................................................................................................................. 6 2. Test Configuration of Equipment Under Test ......................................................................................... 7 2.1. Test Mode ......................................................................................................................................... 7 2.2. Connection Diagram of Test System ................................................................................................ 7 3. Test Result .................................................................................................................................................. 8 3.1. 20dB and 99% Occupied Bandwidth Measurement ......................................................................... 8 3.2. Radiated Emission ............................................................................................................................ 9 3.3. AC Power Line Conducted Emissions Measurement ..................................................................... 11 4. List of Measuring Equipment .................................................................................................................. 13 5. Measurement Uncertainty ....................................................................................................................... 14 Appendix A. Test Results of Conducted Emission Test Appendix B. Test Results of Near Field Test Items Appendix C. Test Results of Radiated Test Items Appendix D. Setup Photographs TEL : 886-3-327-3456 Page Number : 3 of 14 FAX : 886-3-328-4978 Issue Date : Feb. 07, 2024 Report Template No.: BU5-FR15CNFMI Version 2.1 Report Version : 03 FCC RADIO TEST REPORT Report No. : FR370328 History of this test report Report No. Version Description Issue Date FR370328 01 Initial issue of report Dec. 11, 2023 FR370328 02 Revise Appendix D This report is an updated version, replacing the report issued on Dec. 11, 2023. Dec. 27, 2023 FR370328 03 Revise cover page This report is …
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.021 MHz - 0.021 MHz | - |
Smartglove II
Equipment Class
NII - Unlicensed National Information Infrastructure TX