FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Senci Electro mechanical Co.Ltd./
  3. 2BD9Y-SC2000

2BD9Y-SC2000Portable Power Station

Senci Electro mechanical Co.Ltd.
Portable Power Station - FCC ID 2BD9Y-SC2000 - Senci Electro mechanical Co.Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 25, 2026
Application Purpose
Original Equipment
Equipment Note
Portable Power Station
Frequency Range
0.11100000 - 0.20500000
Company
Senci Electro mechanical Co.Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual SC-2000 PORTABLEPOWERSTATION User Manual Before use, please read the user manual of this product to ensure correct use after complete understanding. After reading, please keep the user manual for future reference. If you do not operate this product properly, you may cause serious injury to yourself or others, or cause product damageand property damage. By using this product, you will be deemed to have understood, approved and accepted the full terms and contents of this document. The user undertakes to be responsible for his actions and all consequences arising therefrom. Senci shall not be liable for any loss caused by the user's failure to use the product in accordance with the User Manual.In compliance with the laws and regulations, the Company has the right to the final interpretation of this document and all documents related to this product. Updates, modifications or terminations are subject to notice. Please visit Senci's official website for the latest product information. Disclaimer 01 02 This newly designed solar generator SC- uses high-quality lithium-ion batteries as the main body for energy storage. Compact size, light weight, large capacity, easy to carry, with built-in USB ports, DC and AC outputs, this unit can provide power solutions to you quickly and easily wherever you are in outages or outdoors. Use the Power Cable provided to charge the unit and keep it works properly. SC-2000 PORTABLEPOWERSTATION User Manual The cable is different for different regions. Solar CATALOGCATALOGCATALOGCATALOGCATALOGCATALOG 04 05 06 07 08 09.10.11 Safety Instructions Product appearance introduction 12 13 04 Safety Instructions Usage Do not use the product near a heat source, such as a fire source or a heating furnace.2. Avoid contact with any liquid. Do not immerse the product in water or get it wet. Do not use theproduct in rain or humid environments. Do not use the product in an environment with strong static electricity/magnetic fields Do not disassemble the product in any way or pierce the product with sharp objects. Avoid using wires or other metal objects that may result in a short circuit. Do not use unofficial components or accessories. lf you need to replace any components oraccessories, please visit official SENCI channels to check relevant information. When using the product, please strictly follow the operating environment temperature specified inthis user manual. lf the temperature is too high, it may result in a fire or explosion. if the temperatureis too low, the product performance may be severely reduced, or the product may cease to work. Do not stack any heavy objects on the product. Do not lock the fan forcibly during use or place the product in an unventilated or dusty area. Please avoid impact, falls, or severe vibrations when using the product. n case of a severe externaimpact, turn off the power supply immediately and stop using the product. Ensure the product iswell fastened during transportation to avoid vibrations and impacts. lf you accidentally drop the product into water during use, please place it in a safe open area, andstay away from it until it is completely dry. The dried product should not be used again, and shouldbe properly disposed of according to Section 2.2 below. lf the product catches fire, we recommendthat you use the fire extinguishers in the following order: water or water mist, sand, fire blanket, drypowder,and finally a carbon dioxide fire extinguisher. Use a dry cloth to clean off dirt on the product ports Rest the product on a flat surface to avoid damages caused by the product falling over. lf theproduct is overturned and severely damaged, turn it off immediately, place the battery in an openarea, keep it away from combustible matter and people, and dispose of it in accordance with localaws and regulations. Ensure that the product is kept out of reach of children and pets. DisposalGuide lf conditions permit, make sure that the battery is fully discharged before disposing it in a designatedbattery recycling bin. The product contains batteries with potentially dangerous chemicals, so it isstrictly prohibited to dispose of it in ordinary trash cans. For more details, please follow the local lawsand regulations on battery recycling and disposal. lf the battery cannot be fully discharged due to a product failure, please do not dispose of thebattery directly in the battery recycling box. In such case, you should contact a professional batteryrecycling company for further processing. Please dispose of over-discharged batteries that cannot be recharged. 05 产品基本信息 Net weight:34.1kg(69.23lbs) Dimension:359.7*541.2*337.5mm(14.16*21.31*13.29inches) Battery Capacity: 42Ah, 2150.4Wh. Battery cycle life: ≥3000 times, remaining capacity>80%( LiFePO4) Wireless Charging ×2:15W DC 5521 Output ×2: 13.6V⎓5A, total 8A. Car Outlet Output: 12V⎓10A (DC 5521 Output (2)+ Car Outlet Output: Total 8A max.) FAST CHARGE Output ×2: 5V⎓2.5A, 9V⎓2A, 12V⎓2A(24W max) USB-C 100W Output ×1: 5V⎓3A,9V⎓3A,12V⎓3A,15V⎓3A,20V⎓5A 100W max AC Output ×3: 120V~ 60Hz, total 2000W. Power Station (Two sets can parallel by using parallel box, the parallel box purchased separately.) Generator (Separate parallel box) Parallel Input DC Input: 10V-150V⎓20A max. AC Input : 100V~120Vac 50-60Hz, 1200W max. Type of protection: High temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection 06 Product appearance introduction 13.Parallel 1.LCD Display 4.DC Output Switch 7.USB-C 100W Output 8.FAST CHARGE Output 9.Power Switch 5.120V AC Output 6.AC Output Switch 12.AC Charging protect 15.Wireless Charging Support parallel output of power station/generator, parallel box need to be equipped and it purchased separately. Display the power and usage status of the unit. 10.AC Recharging Input Insert the power cord connector into this port and then connect it to the city p…

Text truncated - open the document above for the full version.

Users Manual

08 When the AC input current is continuously greater than 15A, the AC input port thermal protector will protect itself, and the button will pop up automatically. After confirming that the product has no fault, press the AC input overload protector to resume charging; Charging: the battery level indicator rotates.Charging: the battery level indicator rotates. 1.3 1.8 Recharging Ways Example 2: SP2113*P4/SolarchargingSP2913*P3/ACcharging 09 0 Power on Power outage UPS 10 Note: You need to connect the mains first, then turn on the AC output, and make sure the UPS function icon is lit up, then you can enter the UPS switching function normally. Under normal circumstances, when the load is less than W, the mains power is directly supplied to the load, and when the load is greater than W, the mains power is directly charged by the energy storage power supply, and when the product is fully charged (SOC is displayed as %). Do not plug the parallel cable in when both products are at the same output state, when using the parallel connection. Do not unplug in the middle of the process, when the products are connected in parallel;this is to prevent abnormalities from occurring. Parallel: This product can be connected in parallel expansion using two or more power stations, which can be used to meet the demand for more power and capacity. When using this product for additional parallel connections, follow the user instruction manual. Please make sure that the two products to be paralleled are switched off before using the parallel function and connecting them by using the parallel cable. When the output current is greater than 15A, it needs to be output from a parallel box (parallel box plug accessory must be purchased separately). The rated maximum power and rated battery capacity are doubled when the products are connected in parallel. Please use the parallel cable provided by our company for connection to avoid damage to the product. 11 Parallel Cable (purchased separately) Parallel Power≤3600W 12 Please be aware that this manual is only for this unit SC-2000 and does not represent the manual for others. In addition, this manual is provided as a guide only, the pictures in this manual are for reference only, and all statements, information and suggestions in this manual do not constitute any express or implied warranty. We are always dedicate to the improvement of product itself, therefore, the appearance and performance of units may be slightly different from this manual, please understand. 13 2000W

Attestation Statements

Senci Electro mechanical Co.Ltd. 2025-12-27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BD9Y-SC2000) [Senci Electro mechanical Co.Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Yong sheng Tang Manager Senci Electro mechanical Co.Ltd. No.200 Tongxinbei Road,Beibei District Chongqing 400701,China Senci Electro mechanical Co.Ltd. 2025-12-27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BD9Y-SC2000) [Senci Electro mechanical Co.Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Yong sheng Tang Manager Senci Electro mechanical Co.Ltd. No.200 Tongxinbei Road,Beibei District Chongqing 400701,China

Attestation Statements

Attestation Statements (2025-04-25) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (GC: 2BD9Y) (Senci Electro mechanical Co.Ltd.), the undersigned, hereby authorize (Wilson Tech Service LLC) to act as our designated U.S. agent for service of process,(Senci Electro mechanical Co.Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (Wilson Tech Service LLC) accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Senci Electro mechanical Co.Ltd. Contact Name: Yong sheng Tang Address: No.200Tongxinbei Road,Beibei District Chongqing 400701,China FRN: 0034656249 Telephone No: +86-023-88028731 Email: [email protected] Signature [Yong sheng Tang] U.S. Agent Information: Company Name: Wilson Tech Service LLC Address: 1312 17th Street Suite 692, Denver, CO, 80202, US FRN: 0033402033 Contact Name: Wilson Cheung Telephone No: +1-716-965-5112 Email: [email protected] Signature [Wilson Cheung]

Cover Letter(s)

SenciElectromechanicalCo.Ltd. 2025-12-27 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:LETTEROFAGENTAUTHORIZATION ToWhomItMayConcern: We,theundersigned,herebyauthorizeGuangdongGlobalTestingTechnologyCo.,Ltd.toact onourbehalfinallmattersrelatingtoapplicationforequipmentauthorization,includingthe signingofalldocumentsrelatingtothesematters. Wealsoherebycertifythatnopartytotheapplicationauthorizedhereunderissubjecttothe denialofbenefits,includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseAct of1988,21U.S.C.853(a). Thisagreementexpiresoneyearfromthecurrentdate. Sincerely, YongshengTang Manager SenciElectromechanicalCo.Ltd. No.200TongxinbeiRoad,BeibeiDistrictChongqing400701,China

Cover Letter(s)

SenciElectromechanicalCo.Ltd. 2025-12-27 EurofinsElectricalandElectronicTestingNA,Inc. 914WestPatapscoAvenue Baltimore,MD21230 RE:CONFIDENTIALITYREQUESTFOR(EUTName:PortablePowerStation/Model: SC-2000/FCCID:2BD9Y-SC2000) ToWhomItMayConcern: Thisletterservesasanofficialrequestforconfidentialityundersections0.457and0.459 ofCFR47.Wehaverequestedthatthe(BlockDiagram,OperationalDescription,Schematics) requiredtobesubmittedwiththisapplicationbepermanentlywithheldfrompublic review. Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic.The publicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovideunjustifiedbenefitstoitscompetitors. Pleasecontactmeifthereisanyinformationyoumayneed. Sincerely, YongshengTang Manager SenciElectromechanicalCo.Ltd. No.200TongxinbeiRoad,BeibeiDistrictChongqing400701,China

External Photos

External Photographs View of EUT-1 View of EUT-2 Page 2 of 5 View of EUT-3 View of EUT-4 Page 3 of 5 View of EUT-5 View of EUT-6 Page 4 of 5 View of EUT-7 View of EUT-8 Page 5 of 5 View of EUT-9 View of EUT-10

Internal Photos

Internal Photographs Internal View of EUT-1 Internal View of EUT-2 Page 2 of 6 Internal View of EUT-3 Internal View of EUT-4 Page 3 of 6 Internal View of EUT-5 Internal View of EUT-6 Page 4 of 6 Internal View of EUT-7 Internal View of EUT-8 Page 5 of 6 Internal View of EUT-9 Internal View of EUT-10 Page 6 of 6 Internal View of EUT-11 Internal View of EUT-12

RF Exposure Info

RF EXPOSURE EVALUATION EUT Specification FCC ID: 2BD9Y-SC2000 Characteristics Description Product Name Portable Power Station Model number SC-2000 Series Model / Model difference / Power Supply AC 120V/60Hz DC 150V Battery 51.2V Operating Frequency Range 111-205KHz for phone charging Modulation Technique ASK Antenna Type Coil Antenna Device category Portable (<20cm separation) Mobile (>20cm separation) Others ___ Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Evaluation applied MPE Evaluation SAR Evaluation Applicable Standard: FCC Part 1(1.1310), Part 2(2.1093) and KDB 680106 D01 Wireless Power Transfer v04 Page 2 of 11 Applicable Requirement: Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR ß2.1091. Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFRß2.1093). The FCC also categorizes the use of the device as based upon the user’s awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception oftransient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure. Page 3 of 11 General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Licensees and applicants are responsible for compliance with both the occupational/controlled exposure limits and the general population/uncontrolled exposure limits as they apply to transmitters under their jurisdiction. Licensees and applicants should be aware that the occupational/controlled exposure limits apply especially in situations where workers may have access to areas in very close proximity to antennas and access to the general public may be restricted. In lieu of evaluation with the general population/uncontrolled exposure limits, amateur licensees authorized under part 97 of this chapter and members of his or her immediate household may be evaluated with respect to the occupational/controlled exposure limits in this section, provided appropriate training and information has been provided to the amateur licensee and members of his/her household. Other nearby persons who are not members of the amateur licensee's household must be evaluated with respect to the general population/uncontrolled exposure limits. Test Setup Block Page 4 of 11 Test Procedure 1.Connect the EUT and equipment as above diagram of test configuration. 2.EUT was placed on a table, and the measure probe was placed at a measurement distance of 20cm from the EUT to the center of the probe. 3.Power on the measuring probe, the EUT was set at the maximum field strength emission state. 4.The EUT was put in different directions (Left, Right, Front, Rear, Top and Bottom) toward to the measure probe. The distance from the top of the EUT to the probe is 20cm, and the distance from other directions is 20cm.Measure the value of field strength. 5.Record the worst data of the different directions. Measuring Device and Test Equipment Used Equipment Manufacturer Model No. Serial No. Last Cal. Due Date  E&H-Field Probe(9kHz- 30MHz) Narda EHP-200A 180ZX11012 2025/08/28 2026/08/27 Description of Support Device No. Equipment Manufa…

Text truncated - open the document above for the full version.

Test Report

客户名称:(CUSTOMER) . 物料名称 APPELLATION: A11 Wireless Transmission Single-Coil Module 产品型号 MODE:YX-A11-R501053-G0807. 客户料号 No.:. 生 产 方 工艺审核 TECHNICAL 品质审核 QUALITY 项目审核 PROJECT 开发审核 DEVELOPING 客 户 方 材料工程师 Materials Engineer 设计工程师 Engineer 主管审批 Approval 研发体系 R & D System 供应商名称:Shenzhen Cilanda Electronics Co., Ltd. 供应商地址:深圳市南山区西丽镇牛城村 221 号5 楼 Tel:0755-27652992 29016433 Mail:[email protected] Http: //www.cd-tek.com 产 品 规 格 书 PRODUCT SPECIFICATION SHEET 变更履历表 变更日期变更内容版次备注 2020-05-15新制作A1 1. DIMENSIONS & MARKING: SymbolABCDEF Value(mm) 50.00MAX 21.50±1.50 5.30 4.50±1.00 7.0-9.0 2. ELECTRICALSPECIFICATIONS @25°C 2.1 Operating Temperature range: -40°C~+85°C 2.2 Storage temperature range: -25°C TO +125°C 2.3 The test frequency: 100 KHz, 100mV @ 25°C,65% 2.4 OCL : 6.30 ± 5% μH . 2.5 Diameter : 0.08mm*105P 2.5 Turns Ratio: 10T DRAWN BY:CHECKED BY:APPROVED BY:CUSTOMER: jiuguijiangjiuguijiangwangchunxiaPART NO. : YX-A11-R501053-G0807 REV. : A PAGE: 3Of 4 D C B A E F 43.0±2.00 Shenzhen Cilanda Electronics Co., Ltd. 3、Bill of materials: Serial Number Material Name Material Specification Use of MaterialsRemark 1 Silk-covered Wire 0.08mm*105P√ 2 Self-adhesive Wire 0.08mm*105P 3 Magnetic Sheet G 50.0*5.3*1.0mm√ 4 High-Temperature Tape 8.00*0.05mm√ 5 Adhesive-backed Tape T 48.50*2mm 6 Glue Environmentally Friendly Water-Based Adhesive √ 7 Tin Bar Sn97.3-0.7Cu√ 4、Packaging: 4.1 Quantity per grid: 6 PCS 4.2 Quantity per carton: 6*50 = 300PCS 4.3 Quantity per carton: 300*3 = 900PCS 4.4 Carton size: 350*350*180mm. DRAWN BY:CHECKED BY:APPROVED BY:CUSTOMER: jiuguijiangjiuguijiangwangchunxiaPART NO. : YX-A11-R501053-G0807 REV. : A PAGE: 4Of 4 Shenzhen Cilanda Electronics Co., Ltd. √ Hardness: 38

Test Report

TRF No.: 04-E001-0B TRF Originator: GTG TRF Date: 2023-12-13 Web: www.gtggroup.com E-mail: [email protected] Tel.: 86-400 755 8988 CFR 47 FCC PART 15 SUBPART C TEST REPORT For Portable Power Station MODEL NUMBER: SC-2000 REPORT NUMBER: E04A24110482F00201 ISSUE DATE: December 10, 2025 FCC ID: 2BD9Y-SC2000 Prepared for Senci Electro mechanical Co.Ltd. No.200Tongxinbei Road,Beibei District Chongqing 400701,China Prepared by Guangdong Global Testing Technology Co., Ltd. Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 This report is based on a single evaluation of the submitted sample(s) of the above mentioned Product, it does not imply an assessment of the production of the products. This report shall not be reproduced, except in full, without the written approval ofGuangdong Global Testing Technology Co., Ltd. REPORT NO.: E04A24110482F00201 Page 2 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. Revision History Rev. Issue Date Revisions Revised By V0 December 10, 2025 Initial Issue REPORT NO.: E04A24110482F00201 Page 3 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. Summary of Test Results Test Item Limit/Requirement Result Antenna Requirement FCC Part 15.203 Pass AC Power Line Conducted Emission FCC Part 15.207 Pass 20dB Bandwidth FCC Part 15.215 Pass Radiated Emission FCC Part 15.205/15.209 Pass Note: 1. N/A: In this whole report not applicable. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C> when <Accuracy Method> decision rule is applied. REPORT NO.: E04A24110482F00201 Page 4 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 6 3. FACILITIES AND ACCREDITATION ..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. TEST MODE ............................................................................................................. 8 5.3. SUPPORT UNITS FOR SYSTEM TEST ................................................................... 9 5.4. SETUP DIAGRAM .................................................................................................... 9 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 10 7. RADIATED TEST RESULTS ............................................................................................... 11 7.1. Radiated Spurious Emission ................................................................................... 15 8. AC POWER LINE CONDUCTED EMISSION ...................................................................... 21 9. 20DB BANDWIDTH ............................................................................................................. 24 10. ANTENNA REQUIREMENT ................................................................................... 27 REPORT NO.: E04A24110482F00201 Page 5 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Senci Electro mechanical Co.Ltd. Address: No.200Tongxinbei Road,Beibei District Chongqing 400701,China Manufacturer Information Company Name: Senci Electro mechanical Co.Ltd. Address: No.200Tongxinbei Road,Beibei District Chongqing 400701,China EUT Information Product Description: Portable Power Station Model: SC-2000 Series Model: / Brand: Sample Received Date: November 21, 2025 Sample Status: Normal Sample ID: A24110482 001 Date of Tested: November 21, 2025 to December 3, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 FCC PART 15 SUBPART C Pass Prepared By: Checked By: Jok Yang Alan He Project Engineer Laboratory Leader Approved By: Shawn Wen Laboratory Manager REPORT NO.: E04A24110482F00201 Page 6 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. 2. TEST METHODOLOGY All tests were performed in accordance with the standard CFR 47 FCC PART 15 SUBPART C 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 6947.01) Guangdong Global Testing Technology Co., Ltd. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1343) Guangdong Global Testing Technology Co., Ltd. has been recognized to perform compliance testing on equipment subject to Supplier's Declaration of Conformity (SDoC) and Certification rules ISED (Company No.: 30714) Guangdong Global Testing Technology Co., Ltd. has been registered and fully described in a report filed with ISED. The Company Number is 30714 and the test lab Conformity Assessment Body Identifier (CABID) is CN0148. Note: All tests measurement facilities use to collect the measurement data are located at Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 REPORT NO.: E04A24110482F00201 Page 7 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. 4. CALIBRATION AND UNCERTAINTY 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this repor…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Spurious Emission AC Power Line Conducted Emission RF Exposure Evaluation

Contact Information

Applicant

Yong sheng Tang(Manager)
[email protected]Fax: +86-023-88028731

Technical Contact

Wilson Tech Service LLCWilson Cheung
[email protected]

1312 17th Street Suite 692 · Denver · United States

Test Firm

Guangdong Global Testing Technology Co., Ltd.Shawn Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Senci Electro mechanical Co.Ltd.

Portable Power Station - FCC ID 2BD9Y-SC2400 - Senci Electro mechanical Co.Ltd.
2BD9Y-SC2400

Portable Power Station

Feb 25, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
PORTABLE POWER STATION - FCC ID 2BD9Y-600 - Senci Electro mechanical Co.Ltd.
2BD9Y-600

PORTABLE POWER STATION

Jan 11, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz