Application Details

Equipment Class
VRD - Part 95 Vehicular Radar Systems
Date of Grant
Sep 16, 2024
Application Purpose
Original Equipment
Date of Application
Sep 16, 2024
Equipment Note
Blind Spots Radar
Frequency Range
77000.00000000 - 81000.00000000
Company
Q Global Solutions (Xiamen) Electronics Corp.
Country
China

Documents & Files

Select a file to view

Users Manual

β†—

Attestation Statements

β†—
β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

of Eu

External Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-EXP Page 1 / 3 EUT EXTERNAL PHOTOS Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-EXP Page 2 / 3 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-EXP Page 3 / 3 LED Display

Internal Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 1 / 7 EUT INTERNAL PHOTOS Rada r1Radar 2 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 2 / 7 Radar 1 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 3 / 7 Antenna Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 4 / 7 Radar 2 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 5 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 6 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-INP Page 7 / 7

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402V43192E-RF-00A Report Template Version: FCC-Part 95 M-V1.2 Page 38 of 39 EXHIBIT C - RF EXPOSURE EVALUATION Applicable Standard FCC Β§95.3385 & Β§1.1310 & Β§2.1091 Regardless of the power density levels permitted under this subpart, devices operating under the provisions of this subpart are subject to the radiofrequency radiation exposure requirements specified in Β§Β§ 1.1307(b), 2.1091, and 2.1093 of this chapter, as appropriate. Applications for equipment authorization of devices operating under this section must contain a statement confirming compliance with these requirements for both fundamental emissions and unwanted emissions. Technical information showing the basis for this statement must be submitted to the Commission upon request. Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. See Β§1.1307(b)(1) of this chapter. Limits for Maximum Permissible Exposure (MPE) (Β§1.1310, Β§2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/fΒ²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to Β§1.1310 and Β§2.1091 RF exposure is calculated. Procedure Prediction of power density at the distance of the applicable MPE limit S = PG/4RΒ² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); For simultaneously transmit system, the calculated power density should comply with: Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402V43192E-RF-00A Report Template Version: FCC-Part 95 M-V1.2 Page 39 of 39 Measurement Result Frequency (GHz) EIRP Average Output power Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBm) (mW) 77-81 35 3162 25.0 0.40 1.0 Note: The EIRP including Tune-up Tolerance provided by manufacturer The two radar can transmit simultaneously: =S Radar1 /S limit- Radar1 + S Radar2 /S limit- Radar2 = 0.40*2 =0.8 < 1.0 Result: The device meet FCC MPE at 25 cm distance. ***** END OF REPORT *****

Test Report

TEST REPORT Applicant: Q Global Solutions (Xiamen) Electronics Corp. Address: Floor 3,4,5,No 195 Simingyuan,Tong an Collective Industrial Park,Tong an District, Xiamen, Fujian, China P r o d u c t N a m e : Blind Spots Radar F C C I D : 2BDTH-QRSSK-P Standard(s): 47 CFR Part 95, Subpart M ANSI C63.26-2015 KDB 653005 D01 76-81 GHz Radars v01r02 Report Number: 2402V43192E-RF-00A Report Date: 2024/8/20 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked β–² is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with β˜….This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: 2402V43192E-RF-00A Report Template Version: FCC-Part 95 M-V1.2 Page 2 of 39 CONTENTS DOCUMENT REVISION HISTORY .................................................................................................. 4 1. GENERAL INFORMATION ............................................................................................................ 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................ 5 1.2 ACCESSORY INFORMATION ......................................................................................................................... 5 1.3 ANTENNA INFORMATION DETAILβ–² ........................................................................................................... 5 1.4 EQUIPMENT MODIFICATIONS ...................................................................................................................... 5 2. SUMMARY OF TEST RESULTS .................................................................................................... 6 3 DESCRIPTION OF TEST CONFIGURATION .............................................................................. 7 3.1 EUT OPERATION CONDITION ..................................................................................................................... 7 3.2 EUT EXERCISE SOFTWARE ......................................................................................................................... 7 3.3 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................. 7 3.4 SUPPORT CABLE LIST AND DETAILS ........................................................................................................... 7 3.5 BLOCK DIAGRAM OF TEST SETUP ............................................................................................................... 7 3.6 TEST FACILITY ............................................................................................................................................. 8 3.7 MEASUREMENT UNCERTAINTY ................................................................................................................... 8 4. REQUIREMENTS AND TEST RESULTS ..................................................................................... 9 4.1 EQUIVALENT ISOTROPICALLY RADIATED POWER (EIRP) ....................................................................... 9 4.1.1 Applicable Standard ................................................................................................................................................ 9 4.1.2 EUT Setup ............................................................................................................................................................... 9 4.1.3 Test Procedure ....................................................................................................................................................... 10 4.1.4 Test Data and Result ............................................................................................................................................. 11 4.2 UNWANTED EMISSIONS .............................................................................................................................. 14 4.2.1 Applicable Standard .............................................................................................................................................. 14 4.2.2 EUT Setup ............................................................................................................................................................. 15 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ................................................................................................... 17 4.2.4 Test Procedure ....................................................................................................................................................... 18 4.2.5 Corrected Amplitude & Margin Calculation ......................................................................................................... 18 4.2.6 Test Data and Result ............................................................................................................................................. 20 4.3 FREQUENCY STABILITY:…

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP TEST SETUP PHOTOGRAPHS Radiated Emission 9k-30MHz Parallel View Radiated Emission 9k-30MHz Perpendicular View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP Radiated Emission 9k-30MHz Ground-parallel View Radiated Emission 30M-1GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP Radiated Emission 1-18GHz View Radiated Emission 18-26.5GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP Radiated Emission 26.5-40GHz View Radiated Emission 40-60GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP Radiated Emission 60-90GHz View Radiated Emission 90-140GHz View Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT No.: 2402V43192E-RF-00A-TSP Radiated Emission 140-220GHz View Radiated Emission 220-231GHz View

Contact Information

Applicant

KO-CHIN LOH(Manager)
[email protected]0592-5790369Fax: N/A

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)David Zhang
[email protected]0086-769-8685-8891

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
195M77.00 GHz - 81.00 GHz2.576 W3G46N0N
Confidentiality
Long Term
Grant Notes
Output power listed is average EIRP. Device must be installed to provide a separation distance of at least 25cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Use of this device is limited to vehicular radar operations, or as fixed or mobile operations in air operations areas as allowed by 95.3331. Use in aircraft during flight is prohibited and requires the use of automatic shut-off capability that discontinues all 76-81 GHz radar functions while the aircraft is airborne. Fixed radar use in prohibited outside of airport areas and airborne radar operations.

Other Applications from Q Global Solutions (Xiamen) Electronics Corp.

Front radar - FCC ID 2BDTH-QRM-GTP - Q Global Solutions (Xiamen) Electronics Corp.
2BDTH-QRM-GTP

Front radar

Feb 09, 2026

Equipment Class

VRD - Part 95 Vehicular Radar Systems
2BDTH-QRM150SST

Medium range radar

Jan 18, 2024

Equipment Class

VRD - Part 95 Vehicular Radar Systems