Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 1 THANKYOU Thanksforpurchasingthisproduct.Theproductwillhelpyoukeepfitter,healthierandbetterina veryeasyway. UserGuide 1. Always connect the appliance to a socket with a grounded circuit and no other appliances connectedtoit.Itisrecommendednottouseanyextension 2.Ensurethetreadmillstableonthegroundbeforeuse. 3.Checkifitsfunctionnormalornotbeforerunning. 4.Standontwosiderailswhenthetreadmillstarts 5.Clippedthesafetykeytoyourclotheswhenupcomingtocontrolanyemergency. 6.Pressthe“start”buttontogetthetreadmillstarted. 7. Follow the running belt with left leg to do pre-running.Only when you feel it right, then to run withtwolegsonthetreadmillwithproperrunningposture. 8.ThetreadmillisFORONEPERSONONLY.Overloadisnotallowed. 9.Youcanadjustspeedifnecessary. 10.Afterrunning,you canstop the treadmillby pullingoutthe safety key or pressing the “stop” button. 11.Remembertoturnoffthepowerandpullouttheplugwhenyoufinishexercising. Safetyprecaution : ◆ Placethetreadmillindoorstoavoidanywaterandnoheavystuff. ◆When using the fitness device, wear comfortable clothing and preferably sports or aerobicshoes. ◆ Keepchildrenawayfromthetreadmilltoavoidanyaccident. ◆ No overload to give damages to motor, controller, roller and running belt. Make routine maintenancetothetreadmill. ◆ Keep less indoor dust and a certain extent of humidity to avoid interference of console andcontroller. ◆Keepthehomeusetreadmillcontinuousrunningnomorethan2hours. ◆Keepgoodaircirculationwhenrunning. ◆Thereshouldbe2000x1000mmsafespaceattheendoftreadmillwhenrunning。 ◆Stoprunningifanydiscomfortandconsultthedoctor. 2 ◆Reserve the silicon bottle to some place that children can not reach, to avoid serious mistake. ◆Prohibittheuserjumpingoffthetreadmilldirectlyafteruse. ◆Pulloutthepowerpluggentlyfromthesocket. ◆Stopthemachineifanythingwrongandcutthepowerimmediately. ◆Ask local distributor to handle any issue or provide service. Dismantle the components personallyisnotallowed. DANGER! Toreduceaccidentsordoharmtoanyothers,pleasecheckfollowingrules. ◆Ensureyourclotheszippedupbeforerunning. ◆Donotwearclothesthateasilyhooked. ◆Keeppowercordawayfromhotobjects. ◆Keepchildrenawayfromthetreadmill. ◆Ifsomethingwrong,supportthehandlebartopushupandleaverunningbelt. ◆ Donotusethetreadmilloutdoor. ◆ Cutoffthepowerbeforemoveofthetreadmill. ◆ Donotopenmotorandrollercoverunlessprofessionals. ◆ Thismachinecanbeusedunder10Acircuit. ◆ Ensurethatonlyonepersonatatimeusesthefitnessdevice. ◆ TheHRCtestingmaybeasexactasmedicaldevicessoitsresultsforreferenceonly. ◆Stopexercisingimmediatelyshouldyoufeelunwellorifyoufeelpaininyour joints or muscles. In particular, keep an eye on how your body is responding to the exercise program. Dizziness is a sign that you are exercising too intensively with the device. At the first signsofdizziness,laydownonthegrounduntilyoufeelbetter. 3 Warning! ◆Followingpatientsundertreatmentneedtogetuseofthetreadmillafterapprovalof professionaldoctor. ( 1 ) Thepersonwithbackacheorusedtogethurtintheleg,waist,neck. (2)Thepatientwitharthritisdeformans,rheumatismorgout. (3)Thepatientwithosteoporosis. (4)Thepatientwithabadcirculatorysystemlikeheartdisease,vascular disordersandvascularhypertension. ( 5 ) Thepatientwithrespiratory disturbance. ( 6 ) ThepatientwithArtificialheartrhythmproblem. (7)Thepatientwithmalignanttumors. (8)Thepatientwiththrombosis. (9)Thepatientwithdiabetescausedperceptualdisturbance. (10)Thepersonwithskininjury. ( 11 ) Thepatientwithahighfeverabove38?C. (12)Thepersonwithbentbackbone. (13)Thepersonwithpregnancyorin(menstrual)period. (14)Thepersonfeelsdiscomfortable. (15)Thepersonisobviouslyinabadcondition. ( 16 ) Thepersonforthepurposeofrehabilitation. ( 17 ) Thepersonhavingabnormalphysicalfeatures. -Abovecasesmaycauseaccidentorpoorhealth ◆Stop exercising immediately should you feel unwell like pain in your joints or muscles, dizziness,numb,andabnormalheartbeat,andconsultthedoctorASAP. ◆Keepchildrenawayfromthisproduct. -Youmaygethurtifyouignorethis. ◆Toldthechildrenthatthisisnotatoy. -Youmaygethurtifyouignorethis. ◆whenusing,takingout,puttingbackormovingthisproduct,pleasemakesurethereis nobodyorpetsaround. Prohibit ! ◆stopusethisproductwhenthecovercracked(innerpartscomeout)orweldedpartsdrop off. -maycausedangerorinjury. 4 ◆Donotjumpupordownfromthetreadmillwhenrunning. -mayfalldownandgetinjury. ◆Donotuseorreservethetreadmilloutdoorornearbathroomtoavoidwater. ◆ Donotuseorreservethetreadmillintheareaexposedtodirectsunlight,andavoidhigh temperatureplaceslikeelectricblanketandwarmer. -maycauseelectricleakageorfire. ◆Donotusewhenthepowerlineorplugdamaged,orthesocketisloose. -maycauseelectricshock,shortcircuitorfire. ◆ Donotdamageortwistthepowercord,alsodonotputheavythingsonit. -maycausefireorelectricshock. ◆Onlyforonepersonatatime,tellpeoplearoundnottooclose. -mayfalldownandcauseinjury. ◆peoplewhoisnotconsciousorcan’toperatebyhimselfcannotusethetreadmill. -maycauseaccidentorgetinjury. ◆ disassemble,repair,changebycustomerthemselvesareforbidabsolutely. -maycausemechanicalbreakdownandinjury. Toavoidwater! ◆themainbodyandoperatingcomponentscannotmeetwithwaterordrink. -maycauseelectricshockandfire. Prohibition ! ◆Donotexercisetoomuchifyouarenotaregularsportspeople. ◆Donotusethetreadmillaftermealsorwhenfeeltired. -maycausedamagetoyourhealth. ◆Thisproductisforhomeuse.itcannotuseinschoolorgymnasiumwherearelotsof unspecificusers. -maycauseinjury. ◆Donotusetheproductwhileyouarehavingmealsordoingotheractivities. ◆Donotusetheproductwhenyoufeelthebodybecomeslowafterdrink. -maycause accidentorinjury. ◆ Donotusetheproductwhenyouhavehardobjectinyourpocket. 5 -maycauseaccidentorinjury. ◆thepowerplugcannotbeattachedwithneedle,wasteorwater. -maycauseelectricshock,shortcircuitandfire. ◆ Donotpullouttheplugorswitchthepowerto“off”whileoperating. -maycauseinjury. Donotoperatewithwethands ! ◆Donotpulloutorinserttheplugwithwethands. -maycauseelectricshockorinjury. Remembertopullouttheplug ! ◆ Remembertopullouttheplugwhennotusing. -Dustanddampnesscandamageinsulati…
Text truncated - open the document above for the full version.
ModelNo.: 3305EA
ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. ModelNo.: 3305EA
RFExposureevaluation ProductName:Electrictreadmill FCCID:2BDTT-3305EA-3308EA TestStandard: KDB447498D04GeneralRFExposure Guidancev01 Accordingto447498D04InterimGeneralRFExposureGuidancev01 Antgain=-0.58dBi MaxOutputpower=0.927dBm@2480MHz ERP=0.927dBm-0.58dBi-2.15=-1.803dBm So ERPisworsecase 10^-0.1803=0.6602mW<2.72mW ComplywithRFexposureexemptionlimit.
Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. TestReport Applicant:OMAFITNESSEQUIPMENTCO.,LTD Address: No.93TaiAnRoadSouth,Yang'eVillage,Lunjiao Town,Shunde,Foshan,Guangdong ProductName:Electrictreadmill BrandMark:N/A Model:3305EA Seriesmodel:3308EA ReportNumber:BLA-EMC-202402-A3702 FCCID:2BDTT-3305EA-3308EA DateofReceipt:2024.02.23 DateofTest:2024.02.27to2024.05.08 TestStandard:47CFRPart15,SubpartC15.247 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:2024.05.10 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Address:BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China ReportNo.:BLA-EMC-202402-A3702 Page 2 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] TableofContents 1Generalinformation......................................................................................................................................................5 1.1Generalinformation.................................................................................................................................................5 1.2GeneraldescriptionofEUT.....................................................................................................................................5 2Testsummary................................................................................................................................................................6 3TestConfiguration........................................................................................................................................................7 3.1Testmode................................................................................................................................................................7 3.2Note1:TheEUTwasconfiguredtomeasureitshighestpossibleemissionand/orimmunitylevel.Thetestmodes wereadaptedaccordingtotheoperationmanualforuse.............................................................................................7 3.3OperationFrequencyeachofchannel....................................................................................................................7 3.4Testchannel.............................................................................................................................................................7 3.5Auxiliaryequipment.................................................................................................................................................8 3.6Testenvironment.....................................................................................................................................................8 4Laboratoryinformation................................................................................................................................................9 4.1Laboratoryandaccreditations.................................................................................................................................9 4.2Measurementuncertainty........................................................................................................................................9 5Testequipment............................................................................................................................................................10 6Testresult....................................................................................................................................................................11 6.1Antennarequirement.............................................................................................................................................11 6.2ConductedemissionsatACpowerline(150kHz-30MHz)..................................................................................12 6.3ConductedpeakoutputPower..............................................................................................................................16 6.4Minimum6dBbandwidth.......................................................................................................................................17 6.5Powerspectrumdensity........................................................................................................................................18 6.6ConductedBandEdgesMeasurement.................................................................................................................19 6.7Conductedspuriousemissions.............................................................................................................................20 6.8Radiatedspuriousemissions................................................................................................................................21 6.9Radiatedemissionswhichfallintherestrictedbands..........................................................................................32 7AppendixA..................................................................................................................................................................39 7.1MaximumConductedOutputPower.....................................................................................................................39 7.2-6dBBandwidth.....................................................................................................................................................41 7.3OccupiedChannelBandwidth...............................................................................................................................43 Repor…
Text truncated - open the document above for the full version.
ReportNo.:BLA-EMC-202402-A3702 Page 31 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] [Testmode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202402-A3702 Page 32 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 6.9Radiatedemissionswhichfallintherestrictedbands TestStandard47CFRPart15,SubpartC15.247 TestMethodANSIC63.10(2013)Section6.10.5 TestMode(Pre-Scan)TX TestMode(FinalTest)TX 6.9.1Limit Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.4902400/F(kHz)300 0.490-1.70524000/F(kHz)30 1.705-30.03030 30-881003 88-2161503 216-9602003 Above9605003 Remark:TheemissionlimitsshownintheabovetablearebasedonmeasurementsemployingaCISPR quasi-peakdetectorexceptforthefrequencybands9-90kHz,110-490kHzandabove1000MHz.Radiated emissionlimitsinthesethreebandsarebasedonmeasurementsemployinganaveragedetector,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation. ReportNo.:BLA-EMC-202402-A3702 Page 33 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 6.9.2Testsetup Below1GHz: 30MHz-1GHz: Above1GHz: ReportNo.:BLA-EMC-202402-A3702 Page 34 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 6.9.3Procedure a)Forbelow1GHz,theEUTwasplacedonthetopofarotatingtable0.8metersabovethegroundat a3or10metersemi-anechoicchamber.Thetablewasrotated360degreestodeterminethe positionofthehighestradiation. b)Forabove1GHz,theEUTwasplacedonthetopofarotatingtable1.5metersabovethegroundat a3meterfully-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionof thehighestradiation. c)TheEUTwasset3or10metersawayfromtheinterference-receivingantenna,whichwasmounted onthetopofavariable-heightantennatower. d)Theantennaheightisvariedfromonemetertofourmetersabovethegroundtodeterminethe maximumvalueofthefieldstrength.Bothhorizontalandverticalpolarizationsoftheantennaare settomakethemeasurement. e)Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentheantennawas tunedtoheightsfrom1meterto4meters(forthetestfrequencyofbelow30MHz,theantennawas tunedtoheights1meter)andtherotatabletablewasturnedfrom0degreesto360degreestofind themaximumreading. f)Thetest-receiversystemwassettoPeakDetectFunctionandSpecifiedBandwidthwithMaximum HoldMode. g)IftheemissionleveloftheEUTinpeakmodewas10dBlowerthanthelimitspecified,thentesting couldbestoppedandthepeakvaluesoftheEUTwouldbereported.Otherwisetheemissionsthat didnothave10dBmarginwouldbere-testedonebyoneusingpeak,quasi-peakoraverage methodasspecifiedandthenreportedinadatasheet. h)TesttheEUTinthelowestchannel,themiddlechannel,thehighestchannel. i)TheradiationmeasurementsareperformedinX,Y,ZaxispositioningforTransmittingmode,and foundtheXaxispositioningwhichitistheworstcase. j)Repeataboveproceduresuntilallfrequenciesmeasuredwascomplete. Note1:Level(dBuV)=Reading(dBuV)+Factor(dB/m) Note2:Forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation.Fortheemissionswhosepeaklevelislowerthantheaveragelimit,only thepeakmeasurementisshowninthereport. ReportNo.:BLA-EMC-202402-A3702 Page 35 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 6.9.4Testdata [Testmode:TXlowchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202402-A3702 Page 36 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] [Testmode:TXlowchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202402-A3702 Page 37 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] [Testmode:TXHighchannel];[Polarity:Horizontal] TestResult:Pass ReportNo.:BLA-EMC-202402-A3702 Page 38 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] [Testmode:TXHighchannel];[Polarity:Vertical] TestResult:Pass ReportNo.:BLA-EMC-202402-A3702 Page 39 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 7AppendixA 7.1MaximumConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNTBLE1M2402Ant10.00830Pass NVNTBLE1M2442Ant10.75130Pass NVNTBLE1M2480Ant10.92730Pass PowerNVNTBLE1M2402MHzAnt1 PowerNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202402-A3702 Page 40 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] PowerNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202402-A3702 Page 41 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 7.2-6dBBandwidth ConditionModeFrequency(MHz)Antenna-6dBBandwidth(MHz)Limit-6dBBandwidth(MHz)Verdict NVNTBLE1M2402Ant10.7030.5Pass NVNTBLE1M2442Ant10.7080.5Pass NVNTBLE1M2480Ant10.7350.5Pass -6dBBandwidthNVNTBLE1M2402MHzAnt1 -6dBBandwidthNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202402-A3702 Page 42 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] -6dBBandwidthNVNTBLE1M2480MHzAnt1 ReportNo.:BLA-EMC-202402-A3702 Page 43 of 56 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 7.3OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTBLE1M2402Ant11.0859 NVNTBLE1M2442Ant11.1170 NVNTBLE1M2480Ant11.1388 OBWNVNTBLE1M2402MHzAnt1 OBWNVNTBLE1M2442MHzAnt1 ReportNo.:BLA-EMC-202402-A3702 Page 44 of 56 BlueAsiaofTechnicalServices(Shenz…
Text truncated - open the document above for the full version.
ModelNo.: 3305EA ConductedemissionsatACpowerline(150kHz-30MHz) RadiatedEmissions(30MHz-1GHz) BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected] RadiatedEmissions(above1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.24 mW |

Treadmill
Equipment Class
DTS - Digital Transmission System
Treadmill
Equipment Class
DTS - Digital Transmission System
Electric treadmill
Equipment Class
DTS - Digital Transmission System