Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 14, 2024
Application Purpose
Original Equipment
Date of Application
Aug 11, 2024
Equipment Note
Treadmill
Frequency Range
2402.00000000 - 2480.00000000
Company
OMA FITNESS EQUIPMENT CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 / 33 1 IMPORTANT SAFETY INSTRUCTIONS T h a n k s f o r p u r c h a s i n g t h i s p r o d u c t . T h e p r o d u c t w i l l h e l p y o u k e e p f i t t e r , h e a l t h i e r a n d b e t t e r i n a very easy way. User Guide 1 . A l w a y s c o n n e c t t h e p o w e r p l u g t o a s o c k e t w i t h a g r o u n d e d c i r c u i t a n d t h e s o c k e t m u s t h a v e a special circuit to avoid sharing with other electrical equipment. 2. Ensure the treadmill stable on the ground before use. 3 . C h e c k i f i t s f u n c t i o n n o r m a l o r n o t b e f o r e r u n n i n g . 4 . S t a n d o n t w o s i d e r a i l s w h e n t h e t r e a d m i l l s t a r t s 5 . C l i p p e d t h e s a f e t y k e y t o y o u r c l o t h e s w h e n u p c o m i n g t o c o n t r o l a n y e m e r g e n c y . 6 . P r e s s t h e “ s t a r t ” b u t t o n t o g e t t h e t r e a d m i l l s t a r t e d . 7 . F o l l o w t h e r u n n i n g b e l t w i t h l e f t l e g t o d o p r e p a r a t i o n b e f o r e t r i a l r u n . O n l y w h e n y o u f e e l y o u c a n r u n , y o u c a n s t a n d o n t h e t r e a d m i l l a n d d o i t w i t h t h e r i g h t p o s t u r e . A n d o n l y o n e p e r s o n i s allowed to exercise on the treadmill, and overload exercise is strictly prohibited. 8. You can adjust speed if necessary. 9 . A f t e r r u n n i n g , y o u c a n s t o p t h e t r e a d m i l l b y p u l l i n g o u t t h e s a f e t y k e y o r p r e s s i n g t h e “ s t o p ” b u t t o n . 1 0 . R e m e m b e r t o t u r n o f f t h e p o w e r a n d p u l l o u t t h e p l u g w h e n y o u f i n i s h e x e r c i s i n g . S a f e t y p r e c a u t i o n : ◆ P l a c e t h e t r e a d m i l l i n d o o r s t o a v o i d a n y w a t e r a n d n o h e a v y s t u f f . ◆ W h e n u s i n g t h e f i t n e s s d e v i c e , w e a r c o m f o r t a b l e c l o t h i n g a n d p r e f e r a b l y s p o r t s o r a e r o b i c s h o e s . ◆ K e e p c h i l d r e n a w a y f r o m t h e t r e a d m i l l t o a v o i d a n y a c c i d e n t . ◆ N o o v e r l o a d t o g i v e d a m a g e s t o m o t o r , c o n t r o l l e r , r o l l e r a n d r u n n i n g b e l t . M a k e routine maintenance to the treadmill. ◆Keep less indoor dust and a certain extent of humidity to avoid interference of c o n s o l e a n d c o n t r o l l e r . ◆ K e e p t h e h o u s e h o l d t r e a d m i l l c o n t i n u o u s l y r u n n i n g n o m o r e t h a n 2 h o u r s . ◆ K e e p g o o d a i r c i r c u l a t i o n w h e n r u n n i n g . ◆ T h e r e s h o u l d b e 2 0 0 0 x 1 0 0 0 m m s a f e s p a c e a t t h e e n d o f t r e a d m i l l w h e n r u n n i n g 。 ◆ S t o p r u n n i n g i f a n y d i s c o m f o r t a n d c o n s u l t t h e d o c t o r . ◆ R e s e r v e t h e s i l i c o n b o t t l e t o s o m e p l a c e t h a t c h i l d r e n c a n n o t r e a c h , t o a v o i d s e r i o u s mistake. 2 ◆ Prohibit the user jumping off the treadmill directly after use. ◆ P u l l o u t t h e p o w e r p l u g g e n t l y f r o m t h e s o c k e t . ◆Stop the machine if anything wrong and cut the power immediately. ◆ A s k l o c a l d i s t r i b u t o r t o h a n d l e a n y i s s u e o r p r o v i d e s e r v i c e . D i s m a n t l e t h e components personally is not allowed. D A N G E R ! Tor e d u c e a c c i d e n t s o r h a r m , p l e a s e c h e c k f o l l o w i n g r u l e s . ◆ E n s u r e y o u r c l o t h e s z i p p e d u p b e f o r e r u n n i n g . ◆ D o n o t w e a r c l o t h e s t h a t e a s i l y h o o k e d . ◆ K e e p p o w e r c o r d a w a y f r o m h o t o b j e c t s . ◆ K e e p c h i l d r e n a w a y f r o m t h e t r e a d m i l l . ◆ I f s o m e t h i n g w r o n g , s u p p o r t t h e h a n d l e b a r t o p u s h u p a n d l e a v e r u n n i n g b e l t . ◆ D o n o t u s e t h e t r e a d m i l l o u t d o o r . ◆ C u t o f f t h e p o w e r b e f o r e m o v e o f t h e t r e a d m i l l . ◆ D o n o t o p e n m o t o r a n d r o l l e r c o v e r u n l e s s p r o f e s s i o n a l s . ◆This machine can be used under 10A circuit . ◆ E n s u r e t h a t o n l y o n e p e r s o n a t a t i m e u s e s t h e f i t n e s s d e v i c e . ◆ The HRC testing may be not as exact as medical devices so its results for reference o n l y . ◆ S t o p e x e r c i s i n g i m m e d i a t e l y s h o u l d y o u f e e l u n w e l l o r i f y o u f e e l p a i n i n y o u r j o i n t s o r m u s c l e s . I n p a r t i c u l a r , k e e p a n e y e o n h o w y o u r b o d y i s r e s p o n d i n g t o t h e e x e r c i s e p r o g r a m . D i z z i n e s s i s a s i g n t h a t y o u a r e e x e r c i s i n g t o o i n t e n s i v e l y w i t h t h e d e v i c e . A t the first signs of dizziness, lay down on the ground until you feel better. W a r n i n g a n d P r o h i b i t ! ◆ F o l l o w i n g p a t i e n t s u n d e r t r e a t m e n t n e e d t o g e t u s e o f t h e t r e a d m i l l a f t e r a p p r o v a l o f p r o f e s s i o n a l d o c t o r . (1)The person with backache or used to get hurt in the leg ,waist ,neck . Those with n u m b n e s s o f l e g s , w a i s t , n e c k a n d h a n d s ( t h o s e w i t h c h r o n i c d i s e a s e s s u c h a s i n t e r v e r t e b r a l d i s c p r o t r u s i o n , s p i n a l s l i p , c e r v i c a l v e r t e b r a p r o t r u s i o n , e t c . ) ( 2 ) T h e p a t i e n t w i t h d e f o r m a t i o n a l a r t h r i t i s , r h e u m a t i s m o r g o u t . ( 3 ) T h e p a t i e n t w i t h o s t e r o p o r o s i s . ( 4 ) T h e p a t i e n t w i t h a b a d c i r c u l a t o r y s y s t e m l i k e h e a r t d i s e a s e , v a s c u l a r d i s o r d e r s a n d v a s c u l a r h y p e r t e n s i o n . ( 5 ) T h e p a t i e n t w i t h r e s p i r t o r y d i s t u r b a n c e . 3 ( 6 ) The patient with Artificial heart rhythm problem. ( 7 ) T h e p a t i e n t w i t h m a l i g n a n t t u m o r s …

Text truncated - open the document above for the full version.

Attestation Statements

OMAFITNESSEQUIPMENTCO.,LTD. * theapplicantmustdesignateacontactlocatedintheUnitedStatesforpurposesofactingasthe applicant’sagentforserviceofprocess,regardlessofwhethertheapplicantisadomesticorforeign entity.AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforserviceofprocess. U.S.AgentDesignationforServiceofProcess- CertificationAttestationLetter DATE2024.8.2 TO:FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ATTN.:ReviewingEngineer FCCID:2BDTT-OMA-7200EA FRNofapplicant: 0029677101 Persection2.911(d)(7)oftheFCCrules,[OMAFITNESSEQUIPMENTCO.,LTD. ](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisdesignatedto thefollowingU.S.agent*forserviceofprocess: CompanyName::BaihetianInnovativeSolutions FCCRegistrationNumber(FRN):0033401605 PhysicalU.S.CompanyAddress:6837ChaseRdDearborn,MI48126 ContactPerson:KennethYoung AgentEmailAddress:[email protected] Clickheretoentertext. Theabovecontactpersonacceptstheobligationforserviceofprocess. Theapplicantacceptstomaintainanagentfornolessthanoneyearafterthegranteehas terminatedallmarketingandimportationortheconclusionofanyCommission-related proceedinginvolvingtheequipment. ApplicantSigned: Signed: CompanyName:OMAFITNESSEQUIPMENT CO.,LTD. Date:2024.8. Printed name: Zhi Jian Guo Title: CertificationManager 3 AgentSigned(ifdifferentfromApplicant): Signed: Printedname:KennethYoung Title:Clickheretoentertext. CompanyName:Clickheretoentertext. Date:2024.8.3 Aug 2024 Manager Baihetian Innovative Solutions

External Photos

Product Name :Treadmill

Internal Photos

Product Name :Treadmill

RF Exposure Info

SARevaluation ProductName: Treadmill FCCID: 2BDTT-OMA-7200EA TestStandard: KDB447498D04GeneralRFExposure Guidancev01 Accordingto447498D04InterimGeneralRFExposureGuidancev01 StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-ghead orbodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,by measurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARExclusion Thresholdcondition,listedbelow,issatisfied. CalculatedResultandLimit(WORSECASEISASBELOW) BLE Directional antennaGain (Numeric) PeakOutput Power(dBm) PeakOutput Power(mW) Limit(mW/cm²) TestResult -0.58dBi -4.209 0.379 (2402) Compiles2.7 (0.875) ERP=-4.209-0.58-2.15=-6.939dBm

Test Report

ReportNo.:BLA-EMC-202407-A3702 Page 54 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-48.34-20Pass NVNTBLE1M2480Ant1-48.91-20Pass NVNTBLE2M2402Ant1-48.51-20Pass NVNTBLE2M2480Ant1-49.22-20Pass BandEdgeNVNTBLE1M2402MHzAnt1Ref BandEdgeNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 55 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] BandEdgeNVNTBLE1M2480MHzAnt1Ref BandEdgeNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 56 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] BandEdgeNVNTBLE2M2402MHzAnt1Ref BandEdgeNVNTBLE2M2402MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 57 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] BandEdgeNVNTBLE2M2480MHzAnt1Ref BandEdgeNVNTBLE2M2480MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 58 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] ReportNo.:BLA-EMC-202407-A3702 Page 59 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] ConductedRFSpuriousEmission ConditionModeFrequency(MHz)AntennaMaxValue(dBc)Limit(dBc)Verdict NVNTBLE1M2402Ant1-40.1-20Pass NVNTBLE1M2442Ant1-39.81-20Pass NVNTBLE1M2480Ant1-40.35-20Pass NVNTBLE2M2402Ant1-39.47-20Pass NVNTBLE2M2442Ant1-36.61-20Pass NVNTBLE2M2480Ant1-38.86-20Pass Tx.SpuriousNVNTBLE1M2402MHzAnt1Ref Tx.SpuriousNVNTBLE1M2402MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 60 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Tx.SpuriousNVNTBLE1M2442MHzAnt1Ref Tx.SpuriousNVNTBLE1M2442MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 61 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Tx.SpuriousNVNTBLE1M2480MHzAnt1Ref Tx.SpuriousNVNTBLE1M2480MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 62 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Tx.SpuriousNVNTBLE2M2402MHzAnt1Ref Tx.SpuriousNVNTBLE2M2402MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 63 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Tx.SpuriousNVNTBLE2M2442MHzAnt1Ref Tx.SpuriousNVNTBLE2M2442MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 64 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] Tx.SpuriousNVNTBLE2M2480MHzAnt1Ref Tx.SpuriousNVNTBLE2M2480MHzAnt1Emission ReportNo.:BLA-EMC-202407-A3702 Page 65 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] ReportNo.:BLA-EMC-202407-A3702 Page 66 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] AppendixB:photographsoftestsetup ConductedemissionsatACpowerline(150kHz-30MHz) RadiatedEmissions(30MHz-1GHz) ReportNo.:BLA-EMC-202407-A3702 Page 67 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] RadiatedEmissions(above1GHz) ReportNo.:BLA-EMC-202407-A3702 Page 68 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] AppendixC:photographsofEUT Referencetothetestreportno.BLA-EMC-202407-A3701 ----ENDOFREPORT---- Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,theresult(s)showninthisreportrefer onlytothesample(s)tested.WithoutwrittenapprovalofBlueAsia,thisreportcan’tbereproducedexceptinfull.

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. TestReport Applicant:OMAFITNESSEQUIPMENTCO.,LTD. Address: No.93,Tai'anRoadSouth,Yang'eVillage Committee,LunjiaoSub-districtOffice,Shunde District,FoshanCity ProductName:Treadmill BrandMark:N/A Model:7200EA FCCID:2BDTT-OMA-7200EA ReportNumber:BLA-EMC-202407-A3702 DateofReceipt:2024.07.09 DateofTest:2024.07.09to2024.07.26 TestStandard:47CFRPart15,SubpartC15.247 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:2024.07.26 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Address: BuildingC,No.107,ShihuanRoad,ShiyanSub-District,BaoanDistrict, Shenzhen,GuangdongProvince,China ReportNo.:BLA-EMC-202407-A3702 Page 2 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] TableofContents 1Generalinformation................................................................................................................................................4 1.1Generalinformation..........................................................................................................................................4 1.2GeneraldescriptionofEUT..............................................................................................................................4 2Testsummary..........................................................................................................................................................5 3TestConfiguration..................................................................................................................................................6 3.1Testmode.........................................................................................................................................................6 3.2OperationFrequencyeachofchannel.............................................................................................................7 3.3Testchannel.....................................................................................................................................................7 3.4Auxiliaryequipment..........................................................................................................................................7 3.5Testenvironment..............................................................................................................................................7 4Laboratoryinformation..........................................................................................................................................8 4.1Laboratoryandaccreditations..........................................................................................................................8 4.2Measurementuncertainty.................................................................................................................................8 5Testequipment........................................................................................................................................................9 6Testresult..............................................................................................................................................................10 6.1Antennarequirement......................................................................................................................................10 6.2ConductedemissionsatACpowerline(150kHz-30MHz)...........................................................................11 6.3ConductedpeakoutputPower.......................................................................................................................15 6.4Minimum6dBbandwidth................................................................................................................................16 6.5Powerspectrumdensity.................................................................................................................................17 6.6ConductedBandEdgesMeasurement..........................................................................................................18 6.7Conductedspuriousemissions......................................................................................................................19 6.8Radiatedspuriousemissions.........................................................................................................................20 6.9Radiatedemissionswhichfallintherestrictedbands...................................................................................31 7AppendixA............................................................................................................................................................38 AppendixB:photographsoftestsetup......................................................................................................................66 AppendixC:photographsofEUT................................................................................................................................68 ReportNo.:BLA-EMC-202407-A3702 Page 3 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] ReviseRecord VersionNo.DateDescription 012024.07.26Original ReportNo.:BLA-EMC-202407-A3702 Page 4 of 68 BlueAsiaofTechnicalServices(Shenzhen)Co.,Ltd. Tel:+86-755-23059481 Email:[email protected] 1Generalinformation 1.1Generalinformation ApplicantOMAFITNESSEQUIPMENTCO.,LTD. Address No.93,Tai'anRoadSouth,Yang'eVillageCommittee,Lunjiao Sub-districtOffice,ShundeDistrict,FoshanCity ManufacturerOM…

Text truncated - open the document above for the full version.

Test Setup Photos

Product Name :Treadmill ConductedemissionsatACpowerline(150kHz-30MHz) RadiatedEmissions(30MHz-1GHz) RadiatedEmissions(above1GHz)

Contact Information

Applicant

Zhi Jian Guo
[email protected]13794041053Fax: 86-757-26631617

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz379.40 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from OMA FITNESS EQUIPMENT CO., LTD

Electric treadmill - FCC ID 2BDTT-3305EA-3308EA - OMA FITNESS EQUIPMENT CO., LTD
2BDTT-3305EA-3308EA

Electric treadmill

Aug 20, 2024

Equipment Class

DTS - Digital Transmission System
Treadmill - FCC ID 2BDTT-OMA-7315CA - OMA FITNESS EQUIPMENT CO., LTD
2BDTT-OMA-7315CA

Treadmill

Aug 13, 2024

Equipment Class

DTS - Digital Transmission System
Electric treadmill - FCC ID 2BDTT-OMA-7415EA - OMA FITNESS EQUIPMENT CO., LTD
2BDTT-OMA-7415EA

Electric treadmill

Jul 18, 2024

Equipment Class

DTS - Digital Transmission System