2BFPX-9026Wcar player

SHENZHEN GOBETTER TECHNOLOGY CO.,LTD

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 05, 2026
Application Purpose
Original Equipment
Equipment Note
car player
Frequency Range
2412.00000000 - 2462.00000000
Company
SHENZHEN GOBETTER TECHNOLOGY CO.,LTD
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev1/26/2023 SHENZHENGOBETTERTECHNOLOGYCO.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-7-30 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BFPX-9026W (“SHENZHENGOBETTERTECHNOLOGYCO.,LTD”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. (“SHENZHENGOBETTERTECHNOLOGYCO.,LTD”)certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature)LongLi (Applicantprintedname) Rev1/26/2023 SHENZHENGOBETTERTECHNOLOGYCO.,LTD FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-7-30 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BFPX-9026W (“SHENZHENGOBETTERTECHNOLOGYCO.,LTD”)certifiesthat,asofthedateofthefilingofthe application,SHENZHENGOBETTERTECHNOLOGYCO.,LTDisnotidentifiedontheCoveredList(asa specificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature) (Applicantprintedname)LongLi

Attestation Statements

SHENZHENGOBETTERTECHNOLOGYCO.,LTD 2.911(d)(7)USAAgentv1.4 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:SHENZHENGOBETTERTECHNOLOGYCO.,LTD Address:3F,BuildingB,HengchaoIndustrialZone,ZhoushiRoad,Shiyan Town,Bao'anDistrict,ShenzhenCity,China ProductName:carplayer FCCID:2BFPX-9026W Model(s):9026W,6001W,6002W,6003W,6005W,6006W,6007W,6008W,6009W, 6010W,6011W,6012W,6013W,6015W,6002A,6007A,6008A,6011A,6002C, 6007C,6008C,6011C,7320W,7321W,7322W,7323W,7325W,7326W,7327W, 7328W,7329W,7315C,7316C,7061W,7062W,7063W,7065W,7066W,7067W, 7068W,7069W,7070W,7071W,7073W,7077W,7079W,7055D,6390W,6391W, 6392W,6393W,6395W,6396W,6397W,6398W,6399W,6380C,6381C,6390C, 6391C,6390A,6391A,6392A,6393A,6395A,7260D,6511D,9021W,9022W, 9023W,9025W,9027W,9028W,9029W,9011W,9012W,9013W,9015W,9011A, 9012A,9013A,9001W,9002W,9003W,9005W,9006W,9007W,9008W,9009W, 9001A,9002A,9003A,9005A,9006A,9007A,9008A,9009A,9001C,9002C,9001D, 9310D,1081W,1082W,1083W,1085W,1086W,1087W,1088W,1089W,1086A, 1087A,1088A,1089A,1088C,1089C,1380W,1381W,1382W,1383W,1385W, 1386W,1387W,1388W,1389W,1390W,1380C,1381C,1381A,1383A,1385A, 1381D,1501W,1502W,1503W,1505W,1506W,1507W,1508W,1509W,1501A, 1502A,1503A,1508A,1508C,1580W,1581W,1582W,1583W,1585W,1586W, 1587W,1588W,1589W,1590W,1580C,1581C,1581A,1583A,1585A,9326W, 9310D 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[ShenzhenGoBetterTechnologyCo.,Ltd](“theapplicant”)designate[CELLT INC.]NOTE1forthepurposeofacceptingserviceofprocessonbehalfofthe applicant. Applicantconsent:WeAcknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminated allmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. Agentobligation:WeAcknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. SHENZHENGOBETTERTECHNOLOGYCO.,LTD 2.911(d)(7)USAAgentv1.4 addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicial proceedinginvolvingtheequipment,whicheverislater. USAAgent Companyname:CELLTINC. Address:140121STST#12958 SACRAMENTO,CA95811,USA FRN:0036412567 ContactName:ThompsonLim TelephoneNo:001-424-3474188 Email:[email protected] Applicant Companyname:SHENZHEN GOBETTERTECHNOLOGYCO.,LTD Address:3F,BuildingB,Hengchao IndustrialZone,ZhoushiRoad,Shiyan Town,Bao'anDistrict,ShenzhenCity, China FRN:0035246776 FCCGranteeCode:2BFPX ContactName:LongLi TelephoneNo:+8613923874975 Email:[email protected] Signature: Title:Manager Signature: Title:Manager Date:2026-8-4Date:2026-8-4 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

SHENZHENGOBETTERTECHNOLOGYCO.,LTD Date : 2026-8-4 Product/ModelNumber:carplayer/9026W,6001W,6002W,6003W, 6005W,6006W,6007W,6008W,6009W,6010W,6011W,6012W,6013W, 6015W,6002A,6007A,6008A,6011A,6002C,6007C,6008C,6011C, 7320W,7321W,7322W,7323W,7325W,7326W,7327W,7328W,7329W, 7315C,7316C,7061W,7062W,7063W,7065W,7066W,7067W,7068W, 7069W,7070W,7071W,7073W,7077W,7079W,7055D,6390W,6391W, 6392W,6393W,6395W,6396W,6397W,6398W,6399W,6380C,6381C, 6390C,6391C,6390A,6391A,6392A,6393A,6395A,7260D,6511D, 9021W,9022W,9023W,9025W,9027W,9028W,9029W,9011W,9012W, 9013W,9015W,9011A,9012A,9013A,9001W,9002W,9003W,9005W, 9006W,9007W,9008W,9009W,9001A,9002A,9003A,9005A,9006A, 9007A,9008A,9009A,9001C,9002C,9001D,9310D,1081W,1082W, 1083W,1085W,1086W,1087W,1088W,1089W,1086A,1087A,1088A, 1089A,1088C,1089C,1380W,1381W,1382W,1383W,1385W,1386W, 1387W,1388W,1389W,1390W,1380C,1381C,1381A,1383A,1385A, 1381D,1501W,1502W,1503W,1505W,1506W,1507W,1508W,1509W, 1501A,1502A,1503A,1508A,1508C,1580W,1581W,1582W,1583W, 1585W,1586W,1587W,1588W,1589W,1590W,1580C,1581C,1581A, 1583A,1585A,9326W,9310D FCCID:2BFPX-9026W Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: ď‚·Testing ď‚·Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By:LongLi ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+8613923874975 Onbehalfof:ShenzhenGoBetterTechnologyCo.,Ltd

Cover Letter(s)

SHENZHENGOBETTERTECHNOLOGYCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:July30,2026 Subject;RequestforConfidentiality FCCID:2BFPX-9026W ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:LongLi Title:Manager

Cover Letter(s)

SHENZHENGOBETTERTECHNOLOGYCO.,LTD ProductSimilarityDeclaration Productname:carplayer Modelname:9026W,6001W,6002W,6003W,6005W,6006W,6007W, 6008W,6009W,6010W,6011W,6012W,6013W,6015W,6002A,6007A, 6008A,6011A,6002C,6007C,6008C,6011C,7320W,7321W,7322W, 7323W,7325W,7326W,7327W,7328W,7329W,7315C,7316C,7061W, 7062W,7063W,7065W,7066W,7067W,7068W,7069W,7070W,7071W, 7073W,7077W,7079W,7055D,6390W,6391W,6392W,6393W,6395W, 6396W,6397W,6398W,6399W,6380C,6381C,6390C,6391C,6390A, 6391A,6392A,6393A,6395A,7260D,6511D,9021W,9022W,9023W, 9025W,9027W,9028W,9029W,9011W,9012W,9013W,9015W,9011A, 9012A,9013A,9001W,9002W,9003W,9005W,9006W,9007W,9008W, 9009W,9001A,9002A,9003A,9005A,9006A,9007A,9008A,9009A, 9001C,9002C,9001D,9310D,1081W,1082W,1083W,1085W,1086W, 1087W,1088W,1089W,1086A,1087A,1088A,1089A,1088C,1089C, 1380W,1381W,1382W,1383W,1385W,1386W,1387W,1388W,1389W, 1390W,1380C,1381C,1381A,1383A,1385A,1381D,1501W,1502W, 1503W,1505W,1506W,1507W,1508W,1509W,1501A,1502A,1503A, 1508A,1508C,1580W,1581W,1582W,1583W,1585W,1586W,1587W, 1588W,1589W,1590W,1580C,1581C,1581A,1583A,1585A,9326W, 9310D Trademark:N/A FCCID:2BFPX-9026W We(SHENZHENGOBETTERTECHNOLOGYCO.,LTD)hereby statethatallthemodelsareelectricalidenticalincludingthesame softwareparameterandhardwaredesign(i.e.,circuitdesign,PCB Layout,RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureanddesign (includingproductenclosure,materials,etc.,),theonlydifference arethemodelname,appearanceshapeandappearancecolor. Signature: Name:LongLi Title:Manager Place,date:Shenzhen,2026.8.4

ID Label/Location Info

FCC ID: 2BFPX-9026W Size:35mm*15mm

RF Exposure Info

FCCID:2BFPX-9026W RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091,Unlessspecifically requiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-gextremity SARevaluationforgeneralpopulationexposureconditions,bymeasurementornumericalsimulation,isnot requiredwhenthecorrespondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactofhumanexposure toradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequencyrange (MHz) Electricfield strength (V/m) Magneticfieldstrength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthetotalpowerinputto theantenna,throughthecalculation,wewillknowthedistancerwheretheMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middleandhighest channelindividually. TestResultofRFExposureEvaluation SoaSARtestisnotrequired Operating Mode Frequency Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power Densityat R=20cm Power Density Limit Result (MHz)(dBm)(dBm)(dBm)(dBi)(mW/cm 2 )(mW/cm 2 ) BT2402-2480-1.35 -1±1 0-2.90.000101.0PASS WiFi2.4G2412-246211.08 11±1 12-2.90.0016171.0PASS

Test Report

1 Product specification Quick Reference Antenna model information Antenna Type PCB Frequency 2.44GHz Ant Port Input Pwr dBm. .() 0 Typ BT class 2 output power(. ) Tot Rad Pwr dBm...() -5 8 Input pwr . ( -loss pwr ) Peak EIRP dBm () -2 9. Directivity dBi() 1 ( ) all direction antenna E fficiency dB( ) -5 8. ( . %)26 03 Gain dBi() -2 9 Peak Gain XY . ( -plane) Maximum Power(dBm) -2 9. (XY -plane) Minimum Power dBm() -7 9. (XY -plane) Average Power dBm() -4 5. (XY -plane) Max/ ( )Min Ratio dB 5(XY -plane) Max/ R( )Avg atio dB 1 6 XY. (-plane) Min Avg atio dB/ R( ) -3 4 XY. (-plane) Average Gain dB ( ) -4 5 Avg Ga. ( in XY-plane) Antenna module & Size Antenna Gain Gain Table Unit in dB2 44 @ . GH z XY -plane X Z-plane Y Z-plane E fficiency Peak Avg Peak Avg Peak Avg -2.9-4.5 -3 7.-6 9.-2 9.-6 1.26.03% Manufacturer: SHENZHEN GOBETTER TECHNOLOGY CO.,LTD Address: 3F,Building B, Hengchao Industrial Zone, Zhoushi Road,Shiyan Town,Bao'an District, Shenzhen City, China Antenna model: 9026W 2 3 3D radiation pattern diagram X Y-plane 4 X Z-plane YZ-plane

Test Report

ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26023925E1-2 SZNTT-TR830-0Tel:0755-27889935Web:http://www.ntt-testing.comPage1of30 TESTREPORT Applicant:SHENZHENGOBETTERTECHNOLOGYCO.,LTD Address: 3F,BuildingB,HengchaoIndustrialZone,ZhoushiRoad,Shiyan Town,Bao'anDistrict,ShenzhenCity,China Manufacturer:SHENZHENGOBETTERTECHNOLOGYCO.,LTD Address: 3F,BuildingB,HengchaoIndustrialZone,ZhoushiRoad,Shiyan Town,Bao'anDistrict,ShenzhenCity,China ProductName:carplayer ModelNumber:9026W SeriesModel :Pleaserefertopage5fordetail. Trademark:N/A FCCID:2BFPX-9026W TestDate:Jun.09,2026toJun.18,2026 DateofReport:Jun.22,2026 TestResult: ThisdevicedescribedabovehasbeentestedbyNTT,andthetest resultsshowthattheequipmentundertest(EUT)isincompliance withtheStandardrequirements.Anditisapplicableonlytothetested sampleidentifiedinthereport. TestProcedureUsed: Standards:FCCCFRTitle47Part15SubpartCSection15.247 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+Erratato C63.10a-2024 Preparedby(TestEngineer): CindyQin Reviewer(Supervisor): KenWu Approved(Manager): AbelYu ShenzhenNTTTestingTechnologyCo.,Ltd.ReportNo.:SZNTT26023925E1-2 SZNTT-TR830-0Tel:0755-27889935Web:http://www.ntt-testing.comPage2of30 TABLEOFCONTENT 1.GeneralInformation......................................................................................5 1.1.DescriptionofDevice(EUT).......................................................................................................................5 1.2.ChannelList..................................................................................................................................................5 1.3.Testconfiguration.........................................................................................................................................6 1.4.Summaryoftestresult................................................................................................................................6 1.5.SpecialAccessoriesandAuxiliaryEquipment........................................................................................6 1.6.Testmode......................................................................................................................................................7 1.7.BlockDiagram...............................................................................................................................................8 1.8.TestConditions.............................................................................................................................................8 1.9.MeasurementUncertainty(95%confidencelevels,k=2)......................................................................8 1.10.TestFacility..................................................................................................................................................9 1.11.TestEquipment...........................................................................................................................................9 2.Conductedemissionatthemainsterminalstest....................................11 2.1.Limit..............................................................................................................................................................11 2.2.TestSetup....................................................................................................................................................11 2.3.TestProcedure............................................................................................................................................11 2.4.TestResult...................................................................................................................................................11 3.RadiatedSpuriousEmissions...................................................................12 3.1.Limit..............................................................................................................................................................12 3.2.TestSetup....................................................................................................................................................13 3.3.TestProcedure............................................................................................................................................15 3.4.TestResult...................................................................................................................................................16 4.Dutycycle.....................................................................................................23 4.1.Limit..............................................................................................................................................................23 4.2.TestSetup....................................................................................................................................................23 4.3.TestProcedure............................................................................................................................................23 4.4.TestResult...................................................................................................................................................23 5.ConductedSpuriousEmissions................................................................24 5.1.Limit..............................................................................................................................................................24 5.2.TestSetup....................................................................................................................................................24 5.3.TestProcedure............................................................................................................................................24 5.4.TestResult......................................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page1of52 RF Test Data Duty Cycle........................................................................................................................................................................2 Maximum Average Conducted Output Power..................................................................................................................9 -6dB Bandwidth..............................................................................................................................................................10 Occupied Channel Bandwidth........................................................................................................................................17 Maximum Power Spectral Density Level....................................................................................................................... 24 Band Edge......................................................................................................................................................................31 Conducted RF Spurious Emission.................................................................................................................................40 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page2of52 Duty Cycle ConditionModeFrequency(MHz)AntennaDutyCycle(%)CorrectionFactor(dB)1/T(kHz) NVNTb2412Ant189.760.471.36 NVNTb2437Ant188.920.511.36 NVNTb2462Ant188.670.521.36 NVNTg2412Ant156.422.498.58 NVNTg2437Ant156.552.488.58 NVNTg2462Ant156.552.488.58 NVNTn202412Ant156.342.498.66 NVNTn202437Ant156.342.498.66 NVNTn202462Ant156.342.498.66 NVNTn402422Ant146.063.3713.16 NVNTn402437Ant146.063.3713.16 NVNTn402452Ant146.063.3713.16 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page3of52 Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page4of52 Duty Cycle NVNT b 2462MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page5of52 Duty Cycle NVNT g 2437MHz Ant1 Duty Cycle NVNT g 2462MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page6of52 Duty Cycle NVNT n20 2412MHz Ant1 Duty Cycle NVNT n20 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page7of52 Duty Cycle NVNT n20 2462MHz Ant1 Duty Cycle NVNT n40 2422MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page8of52 Duty Cycle NVNT n40 2437MHz Ant1 Duty Cycle NVNT n40 2452MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page9of52 Maximum Average Conducted Output Power Conditi on Mod e Frequen cy(MHz) Anten na Conduct edPower (dBm) Duty Fact or (dB) Total Conduct edPower (dBm) Total Conduct edPower (W) Limit Conducted(dB m) Verdi ct NVNT b2412Ant110.26 0.47 10.73 0.0118330Pass NVNT b2437Ant18.840.519.350.0086130Pass NVNT b2462Ant110.56 0.52 11.08 0.0128230Pass NVNT g2412Ant17.862.49 10.35 0.0108430Pass NVNT g2437Ant16.382.488.860.0076930Pass NVNT g2462Ant18.222.4810.70.0117530Pass NVNT n20 2412Ant18.022.49 10.51 0.0112530Pass NVNT n20 2437Ant16.562.499.050.0080430Pass NVNT n20 2462Ant18.432.49 10.92 0.0123630Pass NVNT n40 2422Ant16.013.379.380.0086730Pass NVNT n40 2437Ant15.983.379.350.0086130Pass NVNT n40 2452Ant16.953.37 10.32 0.0107630Pass Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page10of52 -6dB Bandwidth ConditionModeFrequency (MHz) Antenna-6dBBandwidth (MHz) Limit-6dBBandwidth (MHz) Verdict NVNTb2412Ant19.1040.5Pass NVNTb2437Ant19.0960.5Pass NVNTb2462Ant19.110.5Pass NVNTg2412Ant116.340.5Pass NVNTg2437Ant116.30.5Pass NVNTg2462Ant116.380.5Pass NVNT n202412Ant117.350.5Pass NVNT n202437Ant117.170.5Pass NVNT n202462Ant117.390.5Pass NVNT n402422Ant135.860.5Pass NVNT n402437Ant135.070.5Pass NVNT n402452Ant135.670.5Pass Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page11of52 -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page12of52 -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page13of52 -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page14of52 -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page15of52 -6dB Bandwidth NVNT n20 2462MHz Ant1 -6dB Bandwidth NVNT n40 2422MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page16of52 -6dB Bandwidth NVNT n40 2437MHz Ant1 -6dB Bandwidth NVNT n40 2452MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page17of52 Occupied Channel Bandwidth ConditionModeFrequency(MHz)Antenna99%OBW(MHz) NVNTb2412Ant111.804 NVNTb2437Ant111.758 NVNTb2462Ant111.832 NVNTg2412Ant116.568 NVNTg2437Ant116.531 NVNTg2462Ant116.607 NVNTn202412Ant117.576 NVNTn202437Ant117.58 NVNTn202462Ant117.635 NVNTn402422Ant136.154 NVNTn402437Ant136.092 NVNTn402452Ant136.179 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page18of52 OBW NVNT b 2412MHz Ant1 OBW NVNT b 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page19of52 OBW NVNT b 2462MHz Ant1 OBW NVNT g 2412MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page20of52 OBW NVNT g 2437MHz Ant1 OBW NVNT g 2462MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page21of52 OBW NVNT n20 2412MHz Ant1 OBW NVNT n20 2437MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page22of52 OBW NVNT n20 2462MHz Ant1 OBW NVNT n40 2422MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page23of52 OBW NVNT n40 2437MHz Ant1 OBW NVNT n40 2452MHz Ant1 Report No.:SZNTT26023925E1-2 SZNTT-TR728-0Page24of52 Maximum Power Spectral Density Level ConditionModeFrequency (MHz) AntennaConducted PSD (dBm/30kHz) Duty Factor (dB) TotalPSD (dBm/30kHz) Limit (dBm/3kHz) Verdict NVNTb2412Ant1-11.850.47-11.388Pass NVNTb2437Ant1-12.920.51-12.418Pass NVNTb2462Ant1-11.380.52-10.868Pass NVNTg2412Ant1-14.232.49-11.748Pass NVNTg2437Ant1-15.742.48-13.268Pass NVNTg2462Ant1-14.82.48-12.328Pass NVNT n202412Ant1-14.662.49-12.178Pass NVNT n202437Ant1-15.762.49-13.278Pass NVNT n202462Ant1-14.332.49-11.848Pass NVNT n402422Ant1-18.83.37-15.438Pass NVNT n…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Long Li(Manager)
[email protected]Fax: N/A

Technical Contact

CELLT INC.Thompson Lim
[email protected]

1401 21ST ST# 12958 · United States

Test Firm

Shenzhen NTT Testing Technology Co., Ltd.Henry Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz12.82 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from SHENZHEN GOBETTER TECHNOLOGY CO.,LTD

car player - FCC ID 2BFPX-5003W - SHENZHEN GOBETTER TECHNOLOGY CO.,LTD
2BFPX-5003W

car player

Feb 05, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter