FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wuyi Jinheng Household goods Co., Ltd/
  3. 2BFX6-QB22

2BFX6-QB22MUSIC BOXING TARGET

Wuyi Jinheng Household goods Co., Ltd
MUSIC BOXING TARGET - FCC ID 2BFX6-QB22 - Wuyi Jinheng Household goods Co., Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 14, 2026
Application Purpose
Original Equipment
Equipment Note
MUSIC BOXING TARGET
Frequency Range
2402.00000000 - 2480.00000000
Company
Wuyi Jinheng Household goods Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

QB22

Attestation Statements

Wuyi Jinheng Household goods Co., Ltd No.9 , Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/08/12 U.S. Agent Designation Wuyi Jinheng Household goods Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BFX6-QB22): Name and company of U.S. agent:DAME INC Physical U.S. address of agent:19 Preston St, Unit 1, Goffstown NH 03045 NH, NH 3045 United States FRN of U.S. agent:0036816189 Email address of U.S. agent:[email protected] DAME INCacknowledges their obligation to accept service of process on behalf of Wuyi Jinheng Household goods Co., Ltd Wuyi Jinheng Household goods Co., Ltd with the FRN [ 0035301472]accepts itsobligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative orjudicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Chirs Liu Manager WuyiJinhengHouseholdgoodsCo.,Ltd Signature LiangshuZhang Manager DAMEINC

External Photos

FCC ID:2BFX6-QB22 External Photos of the EUT FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22

ID Label/Location Info

Label and Location Size: L: 3.0cm*W: 2.0cm Label and Location FCC ID : 2BFX6-QB22

Internal Photos

FCC ID:2BFX6-QB22 Internal Photos of the EUT FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 FCC ID:2BFX6-QB22 Antenna FCC ID:2BFX6-QB22

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID............................................. : CTA26072100102 2BFX6-QB22 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 27, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Wuyi Jinheng Household goods Co., Ltd Address............................................ : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : MUSIC BOXING TARGET Trade Mark ....................................... : N/A Manufacturer .................................... : Wuyi Jinheng Household goods Co., Ltd Model/Type reference ...................... : QB22 Listed Models ................................... : QB20, QB21, QB23, QB24, QB25, QB26, QB27, QB28, QB29 Rating ............................................... : Input: DC 5V Battery: 3.7V 1200mAh 4.44Wh Result ............................................... : PASS Report No.: CTA26072100102 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : MUSIC BOXING TARGET Model /Type : QB22 Listed Models : QB20, QB21, QB23, QB24, QB25, QB26, QB27, QB28, QB29 Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these models. So the tests were performed on model QB22 and the test results for the main test model can cover the listed models. Applicant : Wuyi Jinheng Household goods Co., Ltd Address : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Manufacturer : Wuyi Jinheng Household goods Co., Ltd Address : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26072100102 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufacturing tolerance .......................................................................................... 8 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion ...................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA26072100101 2BFX6-QB22 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jul. 27, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Wuyi Jinheng Household goods Co., Ltd Address ............................................ : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : MUSIC BOXING TARGET Trade Mark ....................................... : N/A Manufacturer .................................... : Wuyi Jinheng Household goods Co., Ltd Model/Type reference ...................... : QB22 Listed Models ................................... : QB20, QB21, QB23, QB24, QB25, QB26, QB27, QB28, QB29 Modulation ....................................... : GFSK, Π/4DQPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : Input: DC 5V Battery: 3.7V 1200mAh 4.44Wh Result ............................................... : PASS Report No.: CTA26072100101 Page 2 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : MUSIC BOXING TARGET Model /Type : QB22 Listed Models : QB20, QB21, QB23, QB24, QB25, QB26, QB27, QB28, QB29 Model difference : The PCB board, circuit, structure and internal of these models are the same, only model number and colour are different for these models. So the tests were performed on model QB22 and the test results for the main test model can cover the listed models. Applicant : Wuyi Jinheng Household goods Co., Ltd Address : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Manufacturer : Wuyi Jinheng Household goods Co., Ltd Address : No.9, Weijiu East Road, Tongqin Industrial Zone, Wuyi County Jinhua, 570100 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26072100101 Page 3 of 45 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description ........................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Facility.......…

Text truncated - open the document above for the full version.

Test Report

1 FCC Appendix RF Test Data for BT FCC ID : 2BFX6-QB22 Company : Wuyi Jinheng Household goods Co., Ltd EUT : MUSIC BOXING TARGET Model Number : QB22 Report No. : CTA26072100101 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.930 2401.541 2402.471 --- --- 2441 0.957 2440.544 2441.501 --- --- 2480 0.960 2479.544 2480.504 --- --- 2DH5 Ant1 2402 1.332 2401.340 2402.672 --- --- 2441 1.287 2440.376 2441.663 --- --- 2480 1.329 2479.343 2480.672 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 6 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.87527 2401.5767 2402.4519 --- --- 2441 0.86619 2440.5786 2441.4448 --- --- 2480 0.86373 2479.5797 2480.4435 --- --- 2DH5 Ant1 2402 1.1858 2401.4181 2402.6039 --- --- 2441 1.1907 2440.4149 2441.6056 --- --- 2480 1.1913 2479.4172 2480.6085 --- --- 7 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 8 2DH5_Ant1_2402 2DH5_Ant1_2441 9 2DH5_Ant1_2480 10 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 0.32 ≤20.97 PASS 2441 0.22 ≤20.97 PASS 2480 -0.05 ≤20.97 PASS 2DH5 Ant1 2402 3.02 ≤20.97 PASS 2441 2.79 ≤20.97 PASS 2480 2.58 ≤20.97 PASS 11 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 0.974 ≥0.960 PASS 2DH5 Ant1 Hop 1.026 ≥0.888 PASS 12 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 13 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.405 316 0.128 ≤0.4 PASS DH3 Ant1 Hop 1.662 163 0.271 ≤0.4 PASS DH5 Ant1 Hop 2.910 116 0.338 ≤0.4 PASS 2DH1 Ant1 Hop 0.415 319 0.132 ≤0.4 PASS 2DH3 Ant1 Hop 1.667 153 0.255 ≤0.4 PASS 2DH5 Ant1 Hop 2.915 106 0.309 ≤0.4 PASS 14 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 15 DH5_Ant1_Hop 16 2DH1_Ant1_Hop 2DH3_Ant1_Hop 17 2DH5_Ant1_Hop 18 19 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 20 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 21 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 0.25 -56.76 ≤-19.75 PASS High 2480 -0.75 -54.58 ≤-20.75 PASS Low Hop_2402 -0.28 -56.74 ≤-20.28 PASS High Hop_2480 -0.06 -53.69 ≤-20.06 PASS 2DH5 Ant1 Low 2402 0.21 -48.91 ≤-19.79 PASS High 2480 -0.17 -57.51 ≤-20.17 PASS Low Hop_2402 -0.76 -52.29 ≤-20.76 PASS High Hop_2480 -1.51 -56.89 ≤-21.51 PASS 22 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 23 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 24 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 25 26 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -0.49 -0.49 --- PASS 30~1000 -0.49 -68.43 ≤-20.49 PASS 1000~26500 -0.49 -40.67 ≤-20.49 PASS 2441 Reference -0.92 -0.92 --- PASS 30~1000 -0.92 -69.1 ≤-20.92 PASS 1000~26500 -0.92 -43.2 ≤-20.92 PASS 2480 Reference -0.41 -0.41 --- PASS 30~1000 -0.41 -69.07 ≤-20.41 PASS 1000~26500 -0.41 -40.19 ≤-20.41 PASS 2DH5 Ant1 2402 Reference -1.42 -1.42 --- PASS 30~1000 -1.42 -48.03 ≤-21.42 PASS 1000~26500 -1.42 -42.11 ≤-21.42 PASS 2441 Reference -1.33 -1.33 --- PASS 30~1000 -1.33 -42.3 ≤-21.33 PASS 1000~26500 -1.33 -41.97 ≤-21.33 PASS 2480 Reference -0.70 -0.70 --- PASS 30~1000 -0.70 -68.64 ≤-20.7 PASS 1000~26500 -0.70 -44.5 ≤-20.7 PASS 27 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 28 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 29 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 30 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 31 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference 32 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 33 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 34 35 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.92 3.75 77.87 1.09 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- ---

Test Report

36 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 37 2DH5_Ant1_2402 2DH5_Ant1_2441 38 2DH5_Ant1_2480 39 Appendix J: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m ] Limit [dBuV/m] Verdict DH5 Ant1 Low 2402 AV 2310.000 -59.8 2.00 1.10 38.50 ≤54 PASS AV 2379.485 -58.87 2.00 1.10 39.43 ≤54 PASS AV 2390.000 -59.3 2.00 1.10 39.00 ≤54 PASS Peak 2310.000 -50.71 2.00 0.00 46.49 ≤74 PASS Peak 2385.890 -48.01 2.00 0.00 49.19 ≤74 PASS Peak 2390.000 -49.58 2.00 0.00 47.62 ≤74 PASS High 2480 AV 2483.500 -58.2 2.00 1.10 40.10 ≤54 PASS AV 2484.160 -57.92 2.00 1.10 40.38 ≤54 PASS AV 2500.000 -59.54 2.00 1.10 38.76 ≤54 PASS Peak 2483.500 -50.04 2.00 0.00 47.16 ≤74 PASS Peak 2498.720 -48.03 2.00 0.00 49.17 ≤74 PASS Peak 2500.000 -52.17 2.00 0.00 45.03 ≤74 PASS 2DH5 Ant1 Low 2402 AV 2310.000 -60.73 2.00 1.09 37.56 ≤54 PASS AV 2378.960 -58.35 2.00 1.09 39.94 ≤54 PASS AV 2390.000 -59.51 2.00 1.09 38.78 ≤54 PASS Peak 2310.000 -52.4 2.00 0.00 44.80 ≤74 PASS Peak 2384.525 -48.72 2.00 0.00 48.48 ≤74 PASS Peak 2390.000 -52.19 2.00 0.00 45.01 ≤74 PASS High 2480 AV 2483.500 -57.67 2.00 1.10 40.63 ≤54 PASS AV 2483.520 -57.67 2.00 1.10 40.63 ≤54 PASS AV 2500.000 -59.07 2.00 1.10 39.23 ≤54 PASS Peak 2483.500 -49.18 2.00 0.00 48.02 ≤74 PASS Peak 2483.840 -47.28 2.00 0.00 49.92 ≤74 PASS Peak 2500.000 -49.97 2.00 0.00 47.23 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 40 Test Graphs DH5_Ant1_Low_2402_AV DH5_Ant1_Low_2402_Peak DH5_Ant1_High_2480_AV 41 DH5_Ant1_High_2480_Peak 2DH5_Ant1_Low_2402_AV 42 2DH5_Ant1_Low_2402_Peak 2DH5_Ant1_High_2480_AV 2DH5_Ant1_High_2480_Peak 43

Test Report

Inverted F Antenna Specification Summary ANT SPECITEM 2.4G ANTModel Name VerticalHorizontal 2500MHz2400MHz2500MHz2400MHz Center Frequency -1.86-2.46-5.25-0.58-0.76-1.26 -0.58dBiMAX. Gain Horizontal and VerticalPolarization Azimuth Beam Pattern Omni-directional 50 OhmImpedance 38.20mmAntenna Length Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Address No. 333 Kexing Road, Xiangzhou District, Zhuhai City 2450MHz2450MHz Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dBi) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Setup Photos

FCC ID:2BFX6-QB22 Test Setup Photos of the EUT FCC ID:2BFX6-QB22

Contact Information

Applicant

Chirs Liu
[email protected]Fax: +86-15397968808

Technical Contact

DAME INCLiangshu Zhang
[email protected]

19 Preston St, Unit 1, Goffstown NH 03045 · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.

Other Applications from Wuyi Jinheng Household goods Co., Ltd

2BFX6-SZJ-03

WEIGHT LOSS VIBRATION FAT THROWING MACHINE

Apr 15, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2BFX6-SZJ-05

Grease cutting machine

Dec 10, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Game boxing disc - FCC ID 2BFX6-QB09 - Wuyi Jinheng Household goods Co., Ltd
2BFX6-QB09

Game boxing disc

Aug 14, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Game boxing disc - FCC ID 2BFX6-QB04 - Wuyi Jinheng Household goods Co., Ltd
2BFX6-QB04

Game boxing disc

Jul 23, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter