FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED/
  3. 2BG93-G3P

2BG93-G3PPORTATABLE POWER GENERATOR

VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED
PORTATABLE POWER GENERATOR - FCC ID 2BG93-G3P - VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 21, 2024
Application Purpose
Original Equipment
Date of Application
Jul 21, 2024
Equipment Note
PORTATABLE POWER GENERATOR
Frequency Range
2402.00000000 - 2480.00000000
Company
VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 23 Rev1.0 Part 1Safari Main Power Button 2Screen ON / OFF Button 3USB Output ON / OFF Button 412V “Cigarette Lighter” ON / OFF Button 512V “Cigarette Lighter” Output 6LCD Display 7AC Output ON / OFF Button 8(4X) AC Output Socket 9(2X) USB Outputs, 5V @ 3A 10(2X) USB 3.0, QC, and PD Outputs 11Safari-XP Connection (Expansion Battery, Sold Separately) 12Built-in Power Cord for AC Charging 13Solar Panel Charge Connection 14120Vac 30A Plug (NEMA # TT-30R) 45 Rev1.0 67 Rev1.0 89 Rev1.0 AC Output Parameters Rated Power / Surge 3,000W / 6,000W Efficiency> 88% Output wavePure sine wave Battery Parameters Battery typeLithium Iron Phosphate (LiFePO4) Maximum capacity1,612Wh Safari XP Capacity (Sold Separately) 2,688Wh Battery Charge Times Safari AC / Solar~2.3 hours / ~2.7 hours Safari + XP AC / Solar~6 hours / ~7.1 hours Solar Charge Parameters Maximum charge power600W max Solar panel charge range 24 - 60VDC, solar panel must be >36VMP <60VOC Maximum charge current25A Solar charger typeMPPT AC Charge Input Parameters Maximum charge power800W Charge voltage range102 - 130VAC Charge frequency range45 - 65Hz AC Output Ports 120VAC 20ANEMA #5-20R 120VAC 30A NEMA #TT-30R DC output Parameters DC output voltage12VDC regulated 12V or socket15A regulated USB-A (2) 5V, 3A / 9V, 2A / 12V, 1.5A (each) USB-C (2)60W, PD 60W / QC 3.0 (each) Life Cycles Safari 3,500+ Safari-XP (sold separately)3,500+ 1011 Rev1.0 Parte 1Botón principal de encendido del Safari 2Botón de encendido/apagado de la pantalla 3Botón de encendido/apagado de la salida USB 4Botón de encendido/apagado del encendedor de 12V 5Salida del encendedor de 12V 6Pantalla LCD 7Botón de encendido/apagado de la salida de AC 8(4X) Toma de salida de AC 9(2X) Salidas USB, 5V a 3A 10(2X) Salidas USB 3.0, QC y PD 11Conexión Safari-XP (Batería de expansión, se vende por separado) 12Cable de alimentación incorporado para cargar AC 13Conexión de carga de panel solar 14Enchufe de 120 V CA 30 A (NEMA # TT-30R) 1213 Rev1.0 1415 Rev1.0

Users Manual

1617 Rev1.0 Parámetros de salida de AC Potencia nominal / Sobretensión 3,000W / 6,000W Efficiencia> 88% Onda de salidaOnda sinusoidal pura Parámetros de la batería Battery typeLithium Iron Phosphate (LiFePO4) Capacidad máxima1,612Wh Capacidad del Safari XP (se vende por separado) 2,688Wh Tiempos de carga de la batería Safari AC / Solar~2.3 hours / ~2.7 hours Safari + XP AC / Solar~6 hours / ~7.1 hours Parámetros de carga solar Potencia máxima de carga600W max Rango de carga de paneles solares 24 - 60VDC, solar panel must be >36VMP <60VOC Corriente de carga máxima25A Tipo de cargador solarMPPT Parámetros de entrada de carga de AC Potencia máxima de carga800W Rango de voltaje de carga102 - 130VAC Rango de frecuencia de carga 45 - 65Hz Puertos de salida de AC 120VAC 20ANEMA #5-20R 120VAC 30A NEMA #TT-30R Parámetros de salida de DC Voltaje de salida de DC12VDC regulated 12V o enchufe15A regulated USB-A (2) 5V, 3A / 9V, 2A / 12V, 1.5A (each) USB-C (2)60W, PD 60W / QC 3.0 (each) Ciclos de vida Safari 3,500+ Safari-XP (se vende por separado) 3,500+ 1819 Rev1.0 2021 Rev1.0 Part 1Bouton principal d'alimentation Safari 2Bouton d'allumage / extinction de l'écran 3Bouton de mise en marche / arrêt de la sortie USB 4Bouton de mise en marche / arrêt 12V 'Allume-cigare' 5Sortie 12V 'Allume-cigare' 6Affichage LCD 7Bouton de mise en marche / arrêt de la sortie AC 8(4X) Prises de sortie AC 9(2X) Sorties USB, 5V @ 3A 10(2X) Sorties USB 3.0, QC et PD 11Connexion Safari-XP (batterie d'extension, vendue séparément) 12Cordon d'alimentation intégré pour la charge AC 13Connexion de charge du panneau solaire 14Prise 120 V CA 30 A (NEMA # TT-30R) 2223 Rev1.0 2425 Rev1.0 Paramètres de Sortie AC Puissance nominale / Surtension 3,000W / 6,000W Efficacité> 88% Onde de sortieOnde sinusoïdale pure Paramètres de la batterie Type de batterieLithium Iron Phosphate (LiFePO4) Capacité maximale1,612Wh Capacité Safari XP (Vendu Séparément) 2,688Wh Temps de Charge de la Batterie Solaire / AC du Safari~2.3 hours / ~2.7 hours Solaire / AC du Safari + XP~6 hours / ~7.1 hours Paramètres de charge solaire Puissance de charge maximale 600W max Plage de charge des pan- neaux solaires 24 - 60VDC, solar panel must be >36VMP <60VOC Courant de charge maximal25A Type de chargeur solaireMPPT Paramètres d’entrée de charge AC Puissance de charge maximale 800W Plage de tension de charge102 - 130VAC Plage de fréquence de charge 45 - 65Hz Paramètres de sortie DC Tension de sortie DC12VDC regulated Prise 12V ou douille15A regulated USB-A (2) 5V, 3A / 9V, 2A / 12V, 1.5A (each) USB-C (2)60W, PD 60W / QC 3.0 (each) Cycle de vie Safari 3,500+ Safari-XP (Vendu séparément) 3,500+ Ports de sortie AC 120VAC 20ANEMA #5-20R 120VAC 30A NEMA #TT-30R 2627 Rev1.0 FCC Warning 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC RF Radiation Exposure Statement: 1.This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2.This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. 28 Rev1.0

Attestation Statements

VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: PORTATABLE POWER GENERATOR FCC ID: 2BG93-G3P Model(s): SAFARI 2.911(d)(5)(i) Equipment Type We, [VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED ] (“the applicant”) certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: David Dai Date: 2024-07-17 Title and Company name: Manager NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: PORTATABLE POWER GENERATOR FCC ID: 2BG93-G3P Model(s): SAFARI 2.911(d)(7) USA Designated Agent for Service of Process We, [VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED] (“the applicant”) designate [Lion Energy, LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Lion Energy, LLC Address: 735 S Auto Mall Drive American Fork,UT 84003 U.S.A FRN: 0035551159 Contact Name: Tyler Hortin Telephone No: 8013686011 Email: [email protected] Applicant Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China. FRN: 0035611185 FCC Grantee Code: 2BG93 Contact Name: David Dai Telephone No: 13928408576 Email: [email protected] Signature: Title: CEO Signature: Title: Manager Date: 2024-07-17 Date: 2024-07-17 VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(7)USA Agent v1.2 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-t o-the-communications-supply-chain-through-the

Cover Letter(s)

VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-07-17 Subject; Request for Long Term Confidentiality FCC ID: 2BG93-G3P To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram BOM Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: David Dai Title: Manager

Cover Letter(s)

Letter of Authorization Company: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: PORTATABLE POWER GENERATOR Model Number: SAFARI FCC Identifier: 2BG93-G3P We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: David Dai Date: 2024-07-17 Title: Manager

External Photos

Model: SAFARI External Model: SAFARI Model: SAFARI

ID Label/Location Info

Label&Location PORTATABLE POWER GENERATOR Model: SAFARI FCC ID: 2BG93-G3P

Internal Photos

Model: SAFARI Internal Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI Model: SAFARI

RF Exposure Info

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Exposure Report For Applicant Name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’ an District, Shenzhen China. EUT Name: PORTATABLE POWER GENERATOR Brand Name: Model Number: SAFARI Series Model Number: N/A Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF240517R00302 Test Standards: 47 CFR Part 2 Subpart J Section 2.1091 FCC ID: 2BG93-G3P Test Conclusion: Pass Test Date: 2024-05-17 to 2024-05-31 Date of Issue: 2024-06-04 Prepared By: Chris Liu / Project Engineer Date: 2024-06-04 Approved By: Ryan.CJ / EMC Manager Date: 2024-06-04 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF240517R00302 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2024-06-04 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF240517R00302 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 3. Test Requirement ................................................................................................................................................................................. 6 3.1 Assessment Result ............................................................................................................................................................... 6 Test Report Number: BTF240517R00302 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 4 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China 1. Introduction 1.1 Identification of Testing Laboratory Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Phone Number: +86-0755-23146130 Fax Number: +86-0755-23146130 1.2 Identification of the Responsible Testing Location Test Location: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Description: All measurement facilities used to collect the measurement data are located at F101,201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China FCC Registration Number: 518915 Designation Number: CN1330 1.3 Laboratory Condition Ambient Temperature: 20°C to 25°C Ambient Relative Humidity: 45% to 55% Ambient Pressure: 100 kPa to 102 kPa 1.4 Announcement (1) The test report reference to the report template version v0. (2) The test report is invalid if not marked with the signatures of the persons responsible for preparing, reviewing and approving the test report. (3) The test report is …

Text truncated - open the document above for the full version.

Test Report

FreqEffiEffiGainGainUHISDHISMaxMinDirectivityBeamwidthAttHAttV (MHz)(%)(dB)(dBi) (dBd)(%)(%)(dB)(dB)(dBi) (3dB)(dB)(dB) 240041.29 -3.84 -0.32 -2.47 22.036 19.25 -0.32 -14.253.5360 45.9945.9 241040.88 -3.89 -0.47 -2.62 22.012 18.866 -0.47 -14.193.4160 45.94 45.84 242037.44 -4.27 -0.86 -3.01 20.255 17.183 -0.86 -15.073.4160 45.87 45.64 243038.04-4.2-0.9 -3.05 20.615 17.421-0.9 -15.393.36045.8 45.53 244040.56 -3.92 -0.78 -2.93 22.05 18.506 -0.78 -14.993.149046.1 45.72 245043.82 -3.58-0.4 -2.55 23.909 19.913-0.4 -14.513.1990 46.28 45.79 246045.36 -3.43 -0.04 -2.19 24.999 20.36 -0.04 -13.93.490 46.29 45.83 247049.22 -3.080.51 -1.64 27.348 21.8690.51 -13.223.5990 46.28 45.84 248049.19 -3.080.66 -1.49 27.606 21.5840.66 -13.913.7490 46.51 45.92 2480.000MHz E1 2480.000MHz E2 皇 !)0 一豆豆。。 ' 7 0 9A' I ll I飞啃割K'.岳ν-1l I\ TJ7 0

Test Report

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Test Report For Applicant Name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China. EUT Name: PORTATABLE POWER GENERATOR Brand Name: Model Number: SAFARI Series Model Number: N/A Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF240517R00301 Test Standards: 47 CFR Part 15.247 Test Conclusion: Pass FCC ID: 2BG93-G3P Test Date: 2024-05-17 to 2024-05-31 Date of Issue: 2024-06-04 Prepared By: Chris Liu / Project Engineer Date: 2024-06-04 Approved By: Ryan.CJ / EMC Manager Date: 2024-06-04 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF240517R00301 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2024-06-04 Original Note: O nce the revision has been made, then previous versions reports are invalid. Test Report Number: BTF240517R00301 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 78 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1 INTRODUCTION ..........................................................................................................................................5 1.1 Identification of Testing Laboratory ...............................................................................................5 1.2 Identification of the Responsible Testing Location ......................................................................5 1.3 Announcement .................................................................................................................................5 2 PRODUCT INFORMATION ..........................................................................................................................6 2.1 Application Information ...................................................................................................................6 2.2 Manufacturer Information ................................................................................................................6 2.3 Factory Information .........................................................................................................................6 2.4 General Description of Equipment under Test (EUT) ...................................................................6 2.5 Technical Information ......................................................................................................................6 3 SUMMARY OF TEST RESULT S .................................................................................................................7 3.1 Test Standards ..................................................................................................................................7 3.2 Uncertainty of Test ...........................................................................................................................7 3.3 Summary of Test Result ..................................................................................................................7 4 TEST CONFIGURATION .............................................................................................................................8 4.1 Test Equipment List .........................................................................................................................8 4.2 Test Auxiliary Equipment ............................................................................................................. 10 4.3 Test Modes ..................................................................................................................................... 10 5 EVALUATION RESULTS (E VA L U AT I O N ) ................................................................................................. 11 5.1 Antenna requirement ..................................................................................................................... 11 5.1.1 Conclusion: ........................................................................................................................... 11 6 RADIO SPECTRUM MATTER TEST RESULTS (RF) .............................................................................. 12 6.1 Conducted Emission at AC power line ....................................................................................... 12 6.1.1 E.U.T. Operation: ................................................................................................................. 12 6.1.2 Test Setup Diagram: ............................................................................................................ 12 6.1.3 Test Data: ............................................................................................................................ 13 6.2 Occupied Bandwidth ...................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Model: SAFARI Conducted Emission at AC power line Band edge emissions (Radiated) Emissions in frequency bands (above 1GHz) Model: SAFARI Emissions in frequency bands (below 1GHz)

Contact Information

Applicant

David Dai(Manager)
[email protected]13928408576Fax: /

Technical Contact

VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED
[email protected]

China

Test Firm

BTF Testing Lab (Shenzhen) Co., Ltd.Ryan CJ
[email protected]8675523146130

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED

Lion Summit Solar Generator - FCC ID 2BG93-GP5 - VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED
2BG93-GP5

Lion Summit Solar Generator

Jul 21, 2024

Equipment Class

DTS - Digital Transmission System