Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 23 PartDescription 1Main Power Switch Turns the Lion Summit display on or off by pressing and holding for several seconds 2LCD Screen Displays charge / discharge time at the interval of 0.1 hours. 10 bars = fully charged 3Input Charging Port Where the solar, auto, and wall charger are plugged in to charge the Lion Summit 4AC Output ON / OFF ButtonTurns the AC ports on or off 5AC Output OutletSupplies AC output from the outlet 6USB-A, USB-C and USB-PD OutputCharges USB Device 712V Output SocketSupplies DC power from the socket 8DC Output ON / OFF ButtonTurns the DC ports on or off 9Carry HandleUsed to carry the Lion Summit 1 9 2 3 4 5 6 7 8 45 67 Charging MethodCharging Time 50W Solar Panel Charging time depends on the directness and brightness of sunlight, usually 8-12 hours 100W Solar Panel Charging time depends on the directness and brightness of sunlight, usually 4-6 hours Wall Charger4-5 Hours 12V DC Socket4.5-7 Hours 8.5” 7.25” 13.5” 89 1Input Voltage Range100 ~ 240V 1Input Voltage Range13 ~ 22V 2 Max Input Current10A 3 Input Wattage 150W 1 Output Voltage5V 2 Output Current2.4A (Max) 3 Output Overcurrent Protection2.7A 4 Output Short Circuit Protection and Disconnection Load Recovery YES 1Output Voltage Range5V / 9V / 12V / 15V / 20V 2Output Current 3A / 3A / 3A / 3A / 3A 3Output Overcurrent Protection 3A 4 Output Short Circuit Protection and Disconnection Load Recovery YES 1 Max Output12V, 10A 2 DC Output Short Circuit ProtectionYes (Disconnect load recovery) 3 DC Output Overcurrent ProtectionYes (Disconnect load recovery) 1 Rated Output Voltage / Frequency120V AC 60Hz 2 Rated Output Power 530W Continuous 3Inverter Efficiency90% 4Output Wave Pure Sine Wave 1 Working Temperature32ºF - 104ºF 2 Storage TemperatureRoom Temperature (14ºF - 113ºF) 3 Cooling MethodActive (Powered Fans) 1Weight18 LBS 1BluetoothVisit - myapp.LionEnergy.com 1Lithium Iron PhosphateLiFePO4 1011 1213 ParteDescripción 1interruptor de alimentación principal Enciende o apaga la pantalla Lion Summit al mantener presionado durante varios segundos 2pantalla LCD Muestra el tiempo de carga / descarga en intervalos de 0,1 horas. 10 barras = carga completa 3Puerto de carga de entradas Dónde se enchufan el cargador solar, de automóvil y de pared para cargar el Lion Summit 4 Botón de encendido / apagado de salida de AC Enciende o apaga los puertos de AC 5Salida de salida de AC Suministra salida de AC desde el tomacorriente 6salidas USB-A, USB-C and USB-PDCarga dispositivo USB 7Zócalo de salida de 12V Suministra alimentación de DC desde el enchufe 8 Botón de encendido / apagado de salida de DC Enciende o apaga los puertos DC 9Asa de transporteSolía llevar la Lion Summit 1 9 2 3 4 5 6 7 8 1415 1617 Método de cargaTiempo de carga Paneles solares de 50W El tiempo de carga depende de la franqueza y el brillo de la luz solar, generalmente de 8 a 12 horas Paneles solares de 100W El tiempo de carga depende de la franqueza y el brillo de la luz solar, generalmente de 4 a 6 horas Cargador de pared4-5 horas Zócalo de 12V DC4.5-7 horas 8.5” 7.25” 13.5”
1819 1Rango de voltaje de entrada100 ~ 240V 1Rango de voltaje de entrada13 ~ 22V 2Corriente de entrada máxima10A 3Potencia de entrada150 máx 1Tensión de salida5V 2Corriente de salida2.4A (máx) 3 Protección contra sobrecorriente de salida 2.7A 4 Protección contra cortocircuitos de salida y Recuperación de carga de desconexión Sí 1Rango de voltaje de salida5V / 9V / 12V / 15V / 20V 2Corriente de salida3A / 3A / 3A / 3A / 3A 3 Protección contra sobrecorriente de salida 3A 4 Protección contra cortocircuitos de salida y Recuperación de carga de desconexión Sí 1Salida máxima12V, 10A 2 Protección contra cortocircuitos de salida de DC Sí (desconectar la recuperación de carga) 3 Protección contra sobrecorriente de salida de DC Sí (desconectar la recuperación de carga) 1 Tensión / frecuencia de salida nominal 120V AC 60Hz 2Potencia nominal de salida530W Continuo 3Eficiencia del inversor90% 4Onda de salidaOnda sinusoidal pura 1Temperatura de trabajo32ºF - 104ºF 2Temperatura de almacenamiento2 Temperatura ambiente (14ºF - 113ºF) 3Método de enfriamientoActivo (ventiladores alimentados) 1Peso18 libras 1Fosfato de hierro y litioLiFePO4 1BluetoothVisitar - myapp.LionEnergy.com 2021 2223 PartDescription 1interrupteur d’alimentation principal Allume ou éteint l’affichage de l’appareil en appuyant et en maintenant enfoncé pendant plusieurs secondes 2Écran ACL Affiche le temps de charge / décharge à un intervalle de 0,1 heure. 10 bars = omplètement chargé 3Port de charge à 3 entrées Où le chargeur solaire, automatique et mural est branché pour charger l’unité 4Bouton marche / arrêt de la sortie ACActive ou désactive les ports AC 5Sortie ACFournit la sortie AC de la prise 6sorties USB-A, USB-C et USB-PDCharge le périphérique USB 7Prise de sortie 12 V Fournit une alimentation DC à partir de la prise 8Bouton marche / arrêt de la sortie DCActive ou désactive les ports DC 9Poignée de transportUtilisé pour transporter l’unité 1 9 2 3 4 5 6 7 8 2425 2627 Méthode de chargeTemps de charge Panneau Solaire 50W Le temps de charge dépend de la directivité et de la luminosité de la lumière du soleil, généralement de 8 à 12 heures Panneau Solaire 100W Le temps de charge dépend de la directivité et de la luminosité de la lumière du soleil, généralement de 4 à 6 heures Chargeur mural4-5 heures Prise 12V DC4.5-7 heures 8.5” 7.25” 13.5” 2829 1Plage de tension d’entrée100 ~ 240V 1Plage de tension d’entrée13 ~ 22V 2Courant d’entrée maximum10A 3Puissance d’entrée150W 1Tension de sortie5V 2Courant de sortie2.4A (Max) 3 Protection contre les surintensités de sortie 2.7A 4 Protection contre les courts-circuits de sortie et Récupération de la charge de déconnexion YES 1Plage de tension de sortie5V / 9V / 12V / 15V / 20V 2Courant de sortie3A / 3A / 3A / 3A / 3A 3 Protection contre les surintensités de sortie 3A 4 Protection contre les courts-circuits de sortie et Récupération de la charge de déconnexion YES 1Production maximale12V, 10A 2 Protection contre les courts-circuits de sortie DC Oui (récupération de charge de déconnexion) 3 Protection contre les surintensités de sortie DC Oui (récupération de charge de déconnexion) 1 Tension de sortie nominale / fréquence 120V AC 60Hz 2Puissance de sortie nominale530W continu 3Efficacité de l’onduleur90% 4Onde de sortieOnde sinusoïdale pure 1Température de fonctionnement32ºF - 104ºF 2Température de stockageTempérature ambiante (14ºF - 113ºF) 3Méthode de refroidissementActif (ventilateurs alimentés) 1Lester18 LBS 1Phosphate de fer au lithiumLiFePO4 1BluetoothVisite - myapp.LionEnergy.com 3031 FCC Warning 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC RF Radiation Exposure Statement: 1.This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2.This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. 32
VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: Lion Summit Solar Generator FCC ID: 2BG93-GP5 Model(s): MPG-2.0 2.911(d)(5)(i) Equipment Type We, [VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED ] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: David Dai Date: 2024-07-17 Title and Company name: Manager NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: Lion Summit Solar Generator FCC ID: 2BG93-GP5 Model(s): MPG-2.0 2.911(d)(5)(ii) Applicant filing We, [VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: David Dai Date: 2024-07-17 Title and Company name: Manager NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(7)USA Agent v1.2 Section 2.911(d)(7) USA Agent for Service of Process Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: Lion Summit Solar Generator FCC ID: 2BG93-GP5 Model(s): MPG-2.0 2.911(d)(7) USA Designated Agent for Service of Process We, [VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED] (“the applicant”) designate [Lion Energy, LLC] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Lion Energy, LLC Address: 735 S Auto Mall Drive American Fork,UT 84003 U.S.A FRN: 0035551159 Contact Name: Tyler Hortin Telephone No: 8013686011 Email: [email protected] Applicant Company name: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China. FRN: 0035611185 FCC Grantee Code: 2BG93 Contact Name: David Dai Telephone No: 13928408576 Email: [email protected] Signature: Title: CEO Signature: Title: Manager Date: 2024-07-17 Date: 2024-07-17 VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED 2.911 (d)(7)USA Agent v1.2 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-t o-the-communications-supply-chain-through-the
VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2024-07-17 Subject; Request for Long Term Confidentiality FCC ID: 2BG93-GP5 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram BOM Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: David Dai Title: Manager
Letter of Authorization Company: VIRY TECHNOLOGY(Shenzhen) CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China Product Name: Lion Summit Solar Generator Model Number: MPG-2.0 FCC Identifier: 2BG93-GP5 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: David Dai Date: 2024-07-17 Title: Manager
Model: MPG-2.0 External Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0
Label&Location Lion Summit Solar Generator Model: MPG-2.0 FCC ID: 2BG93-GP5
Model: MPG-2.0 Internal Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0 Model: MPG-2.0
Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Exposure Report For Applicant Name: VIRY TECHNOLOGY(Shenzhen)CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’ an District, Shenzhen China. EUT Name: Lion Summit Solar Generator Brand Name: Model Number: MPG-2.0 Series Model Number: N/A Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF240517R00202 Test Standards: 47 CFR Part 2 Subpart J Section 2.1091 FCC ID: 2BG93-GP5 Test Conclusion: Pass Test Date: 2024-05-17 to 2024-05-31 Date of Issue: 2024-06-04 Prepared By: Chris Liu / Project Engineer Date: 2024-06-04 Approved By: Ryan.CJ / EMC Manager Date: 2024-06-04 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF240517R00202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2024-06-04 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF240517R00202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................ 4 1.1 Identification of Testing Laboratory ................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location ...................................................................................................... 4 1.3 Laboratory Condition ........................................................................................................................................................... 4 1.4 Announcement ....................................................................................................................................................................... 4 2. Product Information .............................................................................................................................................................................. 5 2.1 Application Information ....................................................................................................................................................... 5 2.2 Manufacturer Information .................................................................................................................................................... 5 2.3 Factory Information .............................................................................................................................................................. 5 2.4 General Description of Equipment under Test (EUT)................................................................................................... 5 3. Test R equirement ................................................................................................................................................................................. 6 3.1 Assessment Result ............................................................................................................................................................... 6 Test Report Number: BTF240517R00202 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 4 of 7 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China 1. Introduction 1.1 Identification of Testing Laboratory Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Phone Number: +86-0755-23146130 Fax Number: +86-0755-23146130 1.2 Identification of the Responsible Testing Location Test Location: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Description: All measurement facilities used to collect the measurement data are located at F101,201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China FCC Registration Number: 518915 Designation Number: CN1330 1.3 Laboratory Condition Ambient Temperature: 20°C to 25°C Ambient Relative Humidity: 45% to 55% Ambient Pressure: 100 kPa to 102 kPa 1.4 Announcement (1) The test report reference to the report template version v0. (2) The test report is invalid if not marked with the signatures of the persons responsible for preparing, reviewing and approving the test report. (3) The test report i…
Text truncated - open the document above for the full version.
FreqEffiEffiGainGainUHISDHISMaxMinDirectivityBeamwidthAttHAttV (MHz)(%)(dB)(dBi) (dBd)(%)(%)(dB)(dB)(dBi) (3dB)(dB)(dB) 240041.29 -3.84 -0.32 -2.47 22.036 19.25 -0.32 -14.253.5360 45.9945.9 241040.88 -3.89 -0.47 -2.62 22.012 18.866 -0.47 -14.193.4160 45.94 45.84 242037.44 -4.27 -0.86 -3.01 20.255 17.183 -0.86 -15.073.4160 45.87 45.64 243038.04-4.2-0.9 -3.05 20.615 17.421-0.9 -15.393.36045.8 45.53 244040.56 -3.92 -0.78 -2.93 22.05 18.506 -0.78 -14.993.149046.1 45.72 245043.82 -3.58-0.4 -2.55 23.909 19.913-0.4 -14.513.1990 46.28 45.79 246045.36 -3.43 -0.04 -2.19 24.999 20.36 -0.04 -13.93.490 46.29 45.83 247049.22 -3.080.51 -1.64 27.348 21.8690.51 -13.223.5990 46.28 45.84 248049.19 -3.080.66 -1.49 27.606 21.5840.66 -13.913.7490 46.51 45.92 2480.000MHz E1 2480.000MHz E2 皇 !)0 一豆豆。。 ' 7 0 9A' I ll I飞啃割K'.岳ν-1l I\ TJ7 0
Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 74 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China RF Test Report For Applicant Name: VIRY TECHNOLOGY(Shenzhen)CO.,LIMITED Address: B208, New generation IT park,139 Chuang Ye 2nd Road, Bao’an District, Shenzhen China. EUT Name: Lion Summit Solar Generator Brand Name: Model Number: MPG-2.0 Series Model Number: N/A Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF240517R00201 Test Standards: 47 CFR Part 15.247 Test Conclusion: Pass FCC ID: 2BG93-GP5 Test Date: 2024-05-17 to 2024-05-31 Date of Issue: 2024-06-04 Prepared By: Chris Liu / Project Engineer Date: 2024-06-04 Approved By: Ryan.CJ / EMC Manager Date: 2024-06-04 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF240517R00201 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 74 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2024-06-04 Original Note: O nce the revision has been made, then previous versions reports are invalid. Test Report Number: BTF240517R00201 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 74 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1 INTRODUCTION ..........................................................................................................................................5 1.1 Identification of Testing Laboratory ...............................................................................................5 1.2 Identification of the Responsible Testing Location ......................................................................5 1.3 Announcement .................................................................................................................................5 2 PRODUCT INFORMATION ..........................................................................................................................6 2.1 Application Information ...................................................................................................................6 2.2 Manufacturer Information ................................................................................................................6 2.3 Factory Information .........................................................................................................................6 2.4 General Description of Equipment under Test (EUT) ...................................................................6 2.5 Technical Information ......................................................................................................................6 3 SUMMARY OF TEST RESULT S .................................................................................................................7 3.1 Test Standards ..................................................................................................................................7 3.2 Uncertainty of Test ...........................................................................................................................7 3.3 Summary of Test Result ..................................................................................................................7 4 TEST CONFIGURATION .............................................................................................................................8 4.1 Test Equipment List .........................................................................................................................8 4.2 Test Auxiliary Equipment ............................................................................................................. 10 4.3 Test Modes ..................................................................................................................................... 10 5 EVALUATION RESULTS (E VA L U AT I O N ) ................................................................................................. 11 5.1 Antenna requirement ..................................................................................................................... 11 5.1.1 Conclusion: ........................................................................................................................... 11 6 RADIO SPECTRUM MATTER TEST RESULTS (RF) .............................................................................. 12 6.1 Conducted Emission at AC power line ....................................................................................... 12 6.1.1 E.U.T. Operation: ................................................................................................................. 12 6.1.2 Test Setup Diagram: ............................................................................................................ 12 6.1.3 Test Data: ............................................................................................................................ 13 6.2 Occupied Bandwidth ..................................…
Text truncated - open the document above for the full version.
Model: MPG-2.0 Conducted Emission at AC power line Band edge emissions (Radiated) Emissions in frequency bands (above 1GHz) Model: MPG-2.0 Emissions in frequency bands (below 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 700.00 µW |

PORTATABLE POWER GENERATOR
Equipment Class
DTS - Digital Transmission System