FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Tenxinbona Technology Co., Ltd./
  3. 2BGPH-GEARGT3

2BGPH-GEARGT3KUMI Smart Watch

Shenzhen Tenxinbona Technology Co., Ltd.
KUMI Smart Watch - FCC ID 2BGPH-GEARGT3 - Shenzhen Tenxinbona Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 24, 2024
Application Purpose
Original Equipment
Date of Application
Jun 23, 2024
Equipment Note
KUMI Smart Watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Tenxinbona Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Attestation Statements (June 18, 2024) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2BGPH-GEARGT3 ) (Shenzhen Tenxinbona Technology Co., Ltd.), the undersigned, hereby authorize (NEWENERGYER LIMITED) to act as our designated U.S. agent for service of process, (Shenzhen Tenxinbona Technology Co., Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (NEWENERGYER LIMITED) accepts the responsibility to act as designated U.S. agent for service of process, provides an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Information: Company name: Shenzhen Tenxinbona Technology Co., Ltd. Contact Name: WANG PING Address: Room 405, Block A, United Financial Holdings Building, No.1 Shihua Road,Futian District, Shenzhen,China Telephone No: 13538214502 Email: [email protected] FRN: 0035487461 Signature [WANG PING] U.S. Agent Information: Company Name: NEWENERGYER LIMITED Address: 1818 S Patton Ct, Denver, CO, 80219 Contact Name: CHUN LIU Telephone No: 213 289 5042 Email: [email protected] FRN: 0034665885 Signature [CHUN LIU]

Attestation Statements

(Shenzhen Tenxinbona Technology Co., Ltd.) (June 18, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BGPH-GEARGT3) [Shenzhen Tenxinbona Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name) WANG PING (Shenzhen Tenxinbona Technology Co., Ltd.) (June 18, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BGPH-GEARGT3) [Shenzhen Tenxinbona Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) WANG PING

Cover Letter(s)

Shenzhen Tenxinbona Technology Co., Ltd. (June 18, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (KUMI Smart Watch / KUMI WATCH Gear GT3 / FCC ID: 2BGPH-GEARGT3) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Signature: Name: WANG PING Title: Certified Engineer

Cover Letter(s)

Shenzhen Tenxinbona Technology Co., Ltd. (June 18, 2024) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen CTB Testing Technology Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: WANG PING Title: Certified Engineer

External Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 4 Model: KUMI WATCH Gear GT3 External Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 4 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location: FCC ID: 2BGPH-GEARGT3 Model No.: KUMI WATCH Gear GT3

RF Exposure Info

Shenzhen CTB Testing Co., Ltd. FCC ID:2BGPH-GEARGT3 Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where: • f(GHZ) is the RF channel transmit frequency in GHz • Power and distance are rounded to the nearest mW and mm before calculation • The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. EDR: Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 3.706 2.35 3±1 4.00 2.51 <5 0.77860 3.00 YES 2.441 3.48 2.23 3±1 4.00 2.51 <5 0.78490 3.00 YES 2.480 3.375 2.18 3±1 4.00 2.51 <5 0.79114 3.00 YES 2.402 4.416 2.76 4±1 5.00 3.16 <5 0.98020 3.00 YES 2.441 4.189 2.62 4±1 5.00 3.16 <5 0.98813 3.00 YES 2.480 4.113 2.58 4±1 5.00 3.16 <5 0.99599 3.00 YES 2.402 4.661 2.92 4±1 5.00 3.16 <5 0.98020 3.00 YES 2.441 4.481 2.81 4±1 5.00 3.16 <5 0.98813 3.00 YES 2.480 4.313 2.70 4±1 5.00 3.16 <5 0.99599 3.00 YES GFSK π /4DQPSK 8DQPSK BLE:1M Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 3.465 2.223±14.002.51<50.778603.00YES 2.44 3.26 2.123±14.002.51<50.784743.00YES 2.480 3.162 2.073±14.002.51<50.791143.00YES GFSK BLE:2M Modulation Channel Freq. (GHz) Conduct ed power (dBm) Conducte d power (mW) Tune-up power (dBm) Max tune-up power (dBm) Max tune-up power (mW) Distance (mm) Result calculatio n SAR Exclusion threshold SAR test exclusion 2.402 3.536 2.263±14.002.51<50.778603.00YES 2.44 3.438 2.213±14.002.51<50.784743.00YES 2.480 3.302 2.143±14.002.51<50.791143.00YES GFSK Conclusion: For the max result : 0.99599≤ FCC Limit 3.0 for 1g SAR.

Test Report

ShenzhenfirstlinecableCo.,LTD Add:21Building,Wanfeng98IndustrialCity,ShajingStreet,Baoan District,Shenzhen AntennaSpecificationforApproval CustomerName : ShenzhenMoYoungtechnologyco.,LTD ProductName : 2.4Gantennalength25mmred Antennatype:monopole PartNO.:C10-35-2.5 WriteBy:ZhuangJiebin IssuedDate:2021-10-08 client: R&DDept BusinessDept ApprovedBy ISDN R&DDept EngineerDept Approval ZhuangCaihong ZhuangJiebinZhuangJiebin ProductSpecification A.ElectricalCharacteristics Frequency 2400MHz ~2500MHz VSWR<3.0 Efficiency >30% Impedance 50 Ohm Polarization Line Gain -5.48DBi B.Material & MechanicalCharacteristics Material of Radiator Cu Cable Type 1.0 19P Red Connector Type : NO Dimension C.Environmental Operation Temperature - 30 °C ~ + 80 ° CStorage Temperature - 30 ° C~+ 85 ° C Test Equipment& Conditions 1.NetworkAnalyzers: Agilent87 53D 5071C 2. CommunicationsTestSet: AgilentE55 25C 3. 3D ChamberTestSystem RadiationPattern:

Test Report

TEST REPORT Compiled by: Reviewed by: Approved by: Zhou Kui Arron Liu Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. “*” indicates the testing items were fulfilled by subcontracted lab. “#” indicates the items are not in CNAS accreditation scope. Product Name: KUMI Smart Watch FCC ID: 2BGPH-GEARGT3 Trademark: KUMI Model Number: KUMI WATCH Gear GT3 Prepared For: Shenzhen Tenxinbona Technology Co., Ltd. Address: Room 405, Block A, United Financial Holdings Building, No.1 Shihua Road, Futian District, Shenzhen,China Manufacturer: Shenzhen Tenxinbona Technology Co., Ltd. Address: Room 405, Block A, United Financial Holdings Building, No.1 Shihua Road, Futian District, Shenzhen,China Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: May. 23, 2024 Sample tested Date: May. 23, 2024 to Jun. 7, 2024 Issue Date: Jun. 7, 2024 Report No.: CTB240607021RFX Test Standards FCC CFR Title 47 Part 15 Subpart C Section 15.247 ANSI C63.10:2013 Test Results PASS Remark: This is Bluetooth radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.:CTB240607021RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 56 TABLE OF CONTENT Test Report Declaration Page 1. VERSION .......................................................................... 4 2. TEST SUMMARY ................................................................... 5 3. MEASUREMENT UNCERTAINTY ..................................................... 6 4. PRODUCT INFORMATION AND TEST SETUP ......................................... 7 4.1 Product Information ................................................................... 7 4.2 Test Setup Configuration ............................................................... 7 4.3 Support Equipment.................................................................... 7 4.4 Channel List ......................................................................... 8 4.5 Test Mode ........................................................................... 8 4.6 Test Environment ..................................................................... 8 5. TEST FACILITY AND TEST INSTRUMENT USED ....................................... 9 5.1 Test Facility .......................................................................... 9 5.2 Test Instrument Used .................................................................. 9 6. AC POWER LINE CONDUCTED EMISSION ............................................ 11 6.1 Block Diagram Of Test Setup .......................................................... 11 6.2 Limit ............................................................................... 11 6.3 Test procedure ...................................................................... 11 6.4 Test Result ......................................................................... 13 7. RADIATED SPURIOUS EMISSION ................................................... 15 7.1 Block Diagram Of Test Setup .......................................................... 15 7.2 Limit ............................................................................... 15 7.3 Test procedure ...................................................................... 16 7.4 Test Result ......................................................................... 17 8. BAND EDGE AND RF COUNDUCTED SPURIOUS EMISSIONS .......................... 26 8.1 Block Diagram Of Test Setup .......................................................... 26 8.2 Limit ............................................................................... 26 8.3 Test procedure ...................................................................... 26 8.4 Test Result ......................................................................... 27 9. COUDUCTED PEAK OUTPUT POWER ............................................... 34 9.1 Block Diagram Of Test Setup .......................................................... 34 9.2 Limit ............................................................................... 34 9.3 Test procedure ...................................................................... 34 9.4 Test Result ......................................................................... 35 10. 20DB OCCUPIED BANDWIDTH ..................................................... 39 10.1 Block Diagram Of Test Setup ......................................................... 39 10.2 Limit .............................................................................. 39 10.3 Test procedure ..................................................................... 39 10.4 Test Result ........................................................................ 39 11. CARRIERFREQUENCIES SEPARATION ............................................. 43 11.1 Block Diagram Of Test Setup ......................................................... 43 11.2 Limit .............................................................................. 43 11.3 Test procedure ..................................................................... 43 11.4 Test Result ........................................................................ 43 12. HOPPING CHANNEL NUMBER ..................................................... 47 12.1 Block Diagram Of Test Setup ......................................................... 47 12.2 Limit .............................................................................. 47 12.3 Te…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: KUMI WATCH Gear GT3 Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions

Contact Information

Applicant

WANG PING
[email protected]13538214502Fax: 13538214502

Test Firm

Shenzhen CTB Testing Technology Co., Ltd.Rita Xiao
[email protected]86-13538218145

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.92 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Shenzhen Tenxinbona Technology Co., Ltd.

HONOR CHOICE KUMI AI Note - FCC ID 2BGPH-ELCME01 - Shenzhen Tenxinbona Technology Co., Ltd.
2BGPH-ELCME01

HONOR CHOICE KUMI AI Note

Apr 30, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
KUMI AI Note - FCC ID 2BGPH-NOTE02 - Shenzhen Tenxinbona Technology Co., Ltd.
2BGPH-NOTE02

KUMI AI Note

Feb 09, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
KUMI Smart Watch - FCC ID 2BGPH-KUMIU5PRO - Shenzhen Tenxinbona Technology Co., Ltd.
2BGPH-KUMIU5PRO

KUMI Smart Watch

Sep 17, 2024

Equipment Class

DTS - Digital Transmission System