FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. KeyLife International Technology Limited/
  3. 2BHGF-0235CCVE

2BHGF-0235CCVEWi-Fi Dual-lens PT Camera

KeyLife International Technology Limited
Wi-Fi Dual-lens PT Camera - FCC ID 2BHGF-0235CCVE - KeyLife International Technology Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 20, 2026
Application Purpose
Original Equipment
Equipment Note
Wi-Fi Dual-lens PT Camera
Frequency Range
2402.00000000 - 2480.00000000
Company
KeyLife International Technology Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Wi-Fi Dual-lens PT Camera P360A-M33F34D Quick Guide Scan for video, user guide, support... x 1x 1 (*Pin type may vary by region) x 1 x 1x 1x 1x 1 Status Description Flashing green Network configuration status Steady green Connected to the network Steady red Device is starting up Flashing red Network Abnormality Reset SD US: +1 833 700 5555 https://youkey.com/pages/contact UK: +44 808 175 3257 Add Device Register code Add Successfully 1 EN Disclaimer and Safety Warnings Copyright Statement No part of this manual may be copied, reproduced, translated or distributed in any form or by any means without prior consent in writing from our company (referred to as us hereafter). The product described in this manual may contain proprietary software owned by our company and its possible licensors. Unless permitted, no one is allowed to copy, distribute, modify, abstract, decompile, disassemble, decrypt, reverse engineer, rent, transfer, or sublicense the software in any form or by any means. EU Authorised Representative UNV Technology EUROPE B.V. Treubstraa 1, 2288 EG, Rijswijk, Netherlands. About This Manual  This manual is intended for multiple product models, and the photos, illustrations, descriptions, etc, in this manual may be different from the actual appearances, functions, features, etc, of the product .  This manual is intended for multiple software versions, and the illustrations and descriptions in this manual may be different from the actual GUI and functions of the software.  Despite our best efforts, technical or typographical errors may exist in this manual. Our company cannot be held responsible for any such errors and reser ves the right to change the manual without prior notice.  Users are fully responsible for the damages and losses that arise due to improper operation.  Our company reser ves the right to change any information in this manual without any prior notice or indication. Due to such reasons as product version upgrade or regulatory requirement of relevant regions, this manual will be periodically updated. Safety Warnings The device must be installed, serviced and maintained by a trained professional with necessary safety knowledge and skills. Before you start using the device, please read through this guide carefully and make sure all applicable requirements are met to avoid danger and loss of property. Storage, Transportation, and Use  Store or use the device in a proper environment that meets environmental requirements, including and not limited to, temperature, humidity, dust , corrosive gases, electromagnetic radiation, etc.  Make sure the device is securely installed or placed on a flat surface to prevent falling.  Unless otherwise specified, do not stack devices.  Ensure good ventilation in the operating environment. Do not cover the vents on the device. Allow adequate space for ventilation.  Protect the device from liquid of any kind.  Make sure the power supply provides a stable voltage that meets the power requirements of the device. Make sure the power supply's output power exceeds the total maximum power of all the connected devices.  Verify that the device is properly installed before connecting it to power.  Do not remove the seal from the device body without consulting our company first. Do not attempt to service the product yourself. Contact a trained professional for maintenance.  Always disconnect the device from power before attempting to move the device.  Take proper waterproof measures in accordance with requirements. Power Requirements  Install and use the device in strict accordance with your local electrical safety regulations.  Use a UL certified power supply that meets LPS requirements if an adapter is used.  Use the recommended cordset (power cord) in accordance with the specified ratings.  Only use the power adapter supplied with your device.  Use a mains socket outlet with a protective earthing (grounding) connection.  Ground your device properly if the device is intended to be grounded. Battery Use Caution  When battery is used, avoid:  Extremely high or low temperature and air pressure during use, storage and transportation;  Battery replacement.  Use the battery properly. Improper use of the battery such as the following may cause risks of fire, explosion or leakage of flammable liquid or gas.  Replace battery with an incorrect type;  Dispose of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery;  Dispose of the used battery according to your local regulations or the batter y manufacturer's instructions. 2 Avertissement de l’utilisation de la batterie  Lorsque utiliser la batterie, évitez:  Température et pression d'air extrêmement élevées ou basses pendant l'utilisation, le stockage et le transport.  Remplacement de la batterie.  Utilisez la batterie correctement. Mauvaise utilisation de la batterie comme celles mentionnées ici, peut entraîner des risques d’incendie, d’explosion ou de fuite liquide de gaz inflammables.  Remplacer la batterie par un type incorrect;  Disposer d’une batterie dans le feu ou un four chaud, écraser mécaniquement ou couper la batterie;  Disposer la batterie utilisée conformément à vos règlements locaux ou aux instructions du fabricant de la batterie. Regulatory Compliance FCC Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Visit https://youkey.com/pages/product-installation-declaration for SDoC Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. N OTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rule…

Text truncated - open the document above for the full version.

Attestation Statements

KeyLife International Technology Limited U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: United Consulting Technology Services Co., Ltd. FRN: 0033495714 Contact Name: David Wu Street Address: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY City/Province/Zip: CA 91748 Telephone No: (626) 217-4022 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicantnoted below. U.S. Agent Signature: Date: 2026-07-31 Signed by (Printed Name/Title): David Wu/ CEO The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion ofany Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: KeyLife International Technology Limited Grantee Code: 2BHGF FRN:0035661016 FCC ID: 2BHGF-0235CCVE Contact Name: Zhao Hu Street Address: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG City/Province/Zip: Hong Kong, China Telephone No: 18167175029 Email: [email protected] Applicant Signature: Date: 2026-07-31 Signed by (Printed Name/Title): Zhao Hu, Certified Engineer

Attestation Statements

FCC COVERED LIST DECLARATION LETTER Page 1 of 1 Revision 1.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name KeyLife International Technology Limited Address Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, Hong Kong FRN 0035661016 Grantee Code 2BHGF FCC ID: 2BHGF-0235CCVE Authorized Contact Name Hu Zhao Contact Phone 18167175029 Contact Email [email protected] KeyLife International Technology Limited (“the applicant”) certifies: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant [is not] identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. - the software to be loaded prior to marketing of the equipment identified above is not “covered” software manufactured by any entity including predecessors, successors, parents, subsidiaries, affiliates or any entity which has rebranded or relabeled the software produced by the entity(ies) identified on the “Covered List”. - the device is not capable of storing or running software listed on the covered list and therefore is inherently compliant. NOTE: Justification/evidence explaining how compliance is met must accompany this letter Link to the Covered List: Covered List Applicant Signature: Date: 2026-07-31 Print Name: Zhaohu Title: Certification Engineer *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.4 April 25, 2025 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name KeyLife International Technology Limited Address Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, Hong Kong FRN 0035661016 Grantee Code 2BHGF FCC ID: 2BHGF-0235CCVE Authorized Contact Name Hu Zhao Contact Phone 18167175029 Contact Email [email protected] I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc. terms and conditions as specified in the TCB Application Form 731 (QSF27-14-01). Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Applicant Signature: Date:2026/07/31 Print Name: Zhaohu Title: Certification Engineer *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Cover Letter(s)

KeyLife International Technology Limited Current Date 2026-0 7-31 To : SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. No. 588 West Jindu Road, Songjiang District, Shanghai, China. 201612 Dear Sir/Madam, Subject: Declaration Letter about Identity of Products *WE KeyLife International Technology Limited, HEREBY DECLARED THAT Product Description: Wi-Fi Dual-lens PT Camera Model No.: P360A-M33F34D, P360A-M55F34D, P360A XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX,P360A-XXXXXXXX-XXXXXXXX-XXXXXXXX-XXXXXXXX, (where X may be '0-9' 'A-Z' 'a-z' '-' or blank; '-' is option) Manufacturer’s Name: KeyLife International Technology Limited Manufacturer’s Address: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG * The P360A-M33F34D and P360A-M55F34D Pro differ in the sensor board lens. All other models differ only in software, which will not be affected, and RF characteristics will not be affected either. original product as follows: Note: The definition of identical should be “electrically identical”. A device will be considered to be electrically identical if no changes are made to the devices’ schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical with the model which has been tested by SGS. Model No.: P360A-M33F34D Manufacturer’s Name: KeyLife International Technology Limited Manufacturer’s Address: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Sincerely, Signature: Printed Name : Zhao Hu Position/Title : Certified Engineer Contact Number: 18167175029

Cover Letter(s)

KeyLife International Technology Limited Date: 2026.07.31 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2BHGF-0235CCVE To whom it may concern: We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with KeyLife International Technology Limited . This authorization is valid until further written notice from the applicant. Name (Printed): ZhaoHu Title: Certification Engineer Signature: On behalf of Company: KeyLife International Technology Limited Telephone: 18167175029

Cover Letter(s)

KeyLife International Technology Limited 2026-07-31 To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: KeyLife International Technology Limited Address: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Regarding: Confidentiality Request regarding application for FCC ID: 2BHGF-0235CCVE LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Description BOM The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature: Printed Name: Zhao Hu Title: Certified Engineer Company Name: KeyLife International Technology Limited

External Photos

Compliance Certification Services (Kunshan) Inc. Page: 1 of 7 External Photos for KSCR2606001401AT Compliance Certification Services (Kunshan) Inc. Page: 2 of 7 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Page: 3 of 7 Compliance Certification Services (Kunshan) Inc. Page: 4 of 7 Compliance Certification Services (Kunshan) Inc. Page: 5 of 7 Compliance Certification Services (Kunshan) Inc. Page: 6 of 7 Compliance Certification Services (Kunshan) Inc. Page: 7 of 7 - End of the Appendix -

ID Label/Location Info

Page 1 of 2 Page 2 of 2

Internal Photos

Compliance Certification Services (Kunshan) Inc. Page: 1 of 5 Internal Photos for KSCR2606001401AT Compliance Certification Services (Kunshan) Inc. Page: 2 of 5 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Page: 3 of 5 Compliance Certification Services (Kunshan) Inc. Page: 4 of 5 Compliance Certification Services (Kunshan) Inc. Page: 5 of 5 - End of the Appendix -

RF Exposure Info

Report No.: KSCR260600140103 Page: 1 of 11 TRF No. CONN_001 A_Jun 1st ,2026 1 Cover Page RF Exposure Evaluation Report Application No.: KSCR2606001401AT FCC ID: 2BHGF-0235CCVE Applicant: KeyLife International Technology Limited Address of Applicant: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Manufacturer: KeyLife International Technology Limited Address of Manufacturer: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Equipment Under Test (EUT): EUT Name: Wi-Fi Dual-lens PT Camera Model No.: P360A-M33F34D, P360A-M55F34D, P360A XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX,P360A-XXXXXXXX-XXXXXXXX- XXXXXXXX-XXXXXXXX, (where X may be '0-9' 'A-Z' 'a-z' '-' or blank; '- ' is option)   There are series models mentioned in this report, and they are identical in electrical and electronic characters. Only the model P360A- M33F34D was tested since their differences as below: the P360A- M33F34D and P360A-M55F34D Pro differ in the sensor board lens. All other models differ only in software. Standard(s) : FCC Rules 47 CFR §2.1091 KDB447498 D04 Interim General RF Exposure Guidance v01 Date of Receipt: 2026-06-11 Date of Test: 2026-06-16 to 2026-07-03 Date of Issue: 2026-07-03 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Report No.: KSCR260600140103 Page: 2 of 11 TRF No. CONN_001 A_Jun 1st ,2026 Revision Record Version Description Date Remark 00 Original 2026-07-03 / Authorized for issue by: Prepared By Maker_Qi/Project Engineer Approved By Terry Hou /Reviewer Report No.: KSCR260600140103 Page: 3 of 11 TRF No. CONN_001 A_Jun 1st ,2026 2 Contents Page 1 Cover Page .................................................................................................................................. 1 2 Contents ...................................................................................................................................... 3 3 General Information..................................................................................................................... 4 3.1 General Description of E.U.T. ................................................................................................ 4 3.2 Details of E.U.T. .................................................................................................................... 4 3.3 Test Location ....................................................................................................................... 5 3.4 Test Facility ......................................................................................................................... 5 4 RF Exposure Test Exemptions ................................................................................................... 6 4.1 FCC RF Exposure Test Exemptions for single RF sources .................................................... 6 5 Measurement and Calculation .................................................................................................. 10 5.1 Maximum transmit power .................................................................................................... 10 5.2 RF Exposure Calculation ..................................................................................................... 11 Report No.: KSCR260600140103 Page: 4 of 11 TRF No. CONN_001 A_Jun 1st ,2026 3 General Information 3.1 General Description of E.U.T. Power supply: AC/DC Adapter1: Model: DCT24W120150US-A3 Input: 100~240V~,50-60Hz,0.7A max Output: 12V/1.5A AC/DC Adapter2: Model: ADS-26FSG-12 12018EPCU Input: 100~240V~,50-60Hz,0.7A max Output: 12V/1.5A 3.2 Details of E.U.T. BLE Operation Frequency: 2402MHz to 2480MHz Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: Dipole Antenna Antenna Gain: 5.22dBi (Provided by the manufacturer) 2.4GHz WiFi Operation Frequency: 802.11b/g/n(HT20)/ax(HE20):2412MHz to 2462MHz;802.11n(HT40)/ax(HE40):2422MHz to 2452MHz Modulation Type: 802.11b: DSSS (CCK, DQPSK, DBPSK), 802.11g/n: OFDM (64-QAM, 16-QAM, QPSK, BPSK), 802.11ax: OFDMA (BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM) Number of Channels: 802.11b/g/n(HT20)/ax(HE20):11;802.11n(HT40)/ax(HE40):7 Channel Spacing: 5MHz Antenna Type: Dipole Antenna Antenna Gain: 5.22dBi (Provided by the manufacturer) Report No.: KSCR260600140103 Page: 5 of 11 TRF No. CONN_001 A_Jun 1st ,2026 3.3 Test Location All tests were performed at: Compliance Certification Services (Kunshan) Inc. No.10 Weiye Rd, Innovation park, Eco&Tec, Development Zone, Kunshan City, Jiangsu, China. Tel: +86 512 5735 5888 Fax: +86 512 5737 0818 No tests were sub-contracted. Note: 1. SGS is not responsible for wrong test results due to incorrect information (e.g., max. internal working frequency, antenna gain, cable loss, etc) is provided by the applicant. (If applicable). 2. SGS is not responsible for the authenticity, integrity and the validity of the conclusion based on results of the data provided by applicant. (If applicable). 3. Sample source: sent by customer. 3.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 2541.01) Compliance Certification Services (Kunshan) Inc. is accredited by the American Association for Laboratory Accreditation (A2LA). • FCC (Designation Number: CN1172) Compliance Certification Services (Kunshan) Inc. has been recognized as an accredited testing laboratory. • ISED (CAB Identifier: CN0072) Compliance Certification Services (Kunshan) Inc. has been recognized by Innovation, Science and Economic Development Canada (ISED) as an accredited testing laboratory. Company Number: 2324E • VCCI (Member No: 1938) The 3m and 10m Semi-anechoic chamber and Shielded Room of Compliance Certification Services (Kunshan) Inc. has been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: R-20134, R-11600, C-11707, T-11499, G-10216 respectively. Report No.: KSCR260600140103 …

Text truncated - open the document above for the full version.

Test Report

DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 1 /8 承认书 APPROVALSHEET 客户名称 CUSTOMERNAME: 产品名称2.4GW12杆套 PRODUCTNAME: W17下固白色天L=250mm+端子 客户料号 CUSTOMERP/N: 优比电子料号 YoubiP/N:UB02C250W3D5249AREV:D MANUFACTURER SIGNATURE CUSTOMER SIGNATURE CHECKEDBY: Lina APPROVEDBY:Wenqiang.xiong DATE:2025-06-11 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 2 /8 ModificationHistory VersionContentRevisionIssuedbyDate AOriginalversionBin.Wan2024-03-12 BPlastictoningBin.Wan2024-05-15 C Changethecolorofthesilicone ring Bin.Wan2024-08-14 DChangethesizeofthesiliconeringlina2025-06-11 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 3 /8 Content ltemDescription 1.--------------------------------------------------------------------ElectricalSpecification 2.---------------------------------------------------------------TestItemsandEquipment 3.---------------------------------------------------------------------------------SParameter 4.------------------------------------------------------------------------EfficiencyandGain 5.---------------------------------------------------------------------------RadiationPattern 6.-----------------------------------------------------------------MechanicalSpecification DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 4 /8 1.ElectricalSpecification: 2.TestItemsandEquipment CharacteristicsSpecificationsUnit OutlineDimensions19.11x130.8,L250mm Frequency 2400-2500 MHz Impedance50Ω VSWR≤ 1.92 PolarizationLinearPolarization Gain3REF dBi Efficiency>40 % ConnectorTypeMHF-1-Plug Operatingtemperature-20°C~+70°C StorageTemp-20°C~+70°C TestitemsTestequipment SParameter 1.ReturnLoss 2.VSWR Networkanalyzer (AgilentE5071B) Thewholemachineof Passiveparameters 1.Frequency 2.Gain 3.RadiationPattern 1.3Dmicrowavedarkroom (5m*5m*5m) 2.Networkanalyzer (AgilentE5071B) Thewholemachineof Activeparameters 1.TRP 2.TIS 1.3Dmicrowavedarkroom (5m*5m*5m) 2.Comprehensivetestinstrument (CMW500) DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 5 /8 3.SParameter *VoltageStandingWaveRatio(VSWR) ReturnLoss(RL) RL=20*log10[(VSWR+1)/(VSWR-1) 4.EfficiencyandGain Frequency (MHz) 240024502500 Efficiency (%) 49.7754.3355.08 Gain (dBi) 4.835.065.22 Frequency(MHz)VSWR 24001.18 24501.28 25001.19 DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 6 /8 5.RadiationPattern 5-1Antenna3DRadiationPattern 2400MHz 2450MHz 2500MHz DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 7 /8 5-2Antenna2DRadiationPattern Phi02D Phi902D Theta902D Vertical Plane Horizontal Plane DongguanYoubiElectronicsCo.,LTDHangzhouYoubigeElectronicsCo.,LTDShenzhenYoubiElectronicsCo.,LTD Room101,Building2,No.9,Room106,Building3,LetongSciencePark,Room106,BuildingA,XinzhengIndustrialPark, XinfaRoad,LinVillage,TangxiaTownNo.500QiuyiRoad,BinjiangDistrict57LiuxianRoad,Bao'anDistrict,Shenzhen Tel:+86-769-81777126Website:www.ubuant.com 8 /8 6.MechanicalSpecification:

Test Report

Report No.: KSCR260600140102 Page: 1 of 167 TRF No. CONN_001 A_Jun 1st ,2026 TEST REPORT Application No.: KSCR2606001401AT FCC ID: 2BHGF-0235CCVE Applicant: KeyLife International Technology Limited Address of Applicant: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Manufacturer: KeyLife International Technology Limited Address of Manufacturer: Workshop 7, 6th Floor Core 45, No. 43 Tsun Yip Street, Kowloon, HONG KONG Equipment Under Test (EUT): EUT Name: Wi-Fi Dual-lens PT Camera Model No.: P360A-M33F34D, P360A-M55F34D, P360A XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX,P360A-XXXXXXXX-XXXXXXXX-XXXXXXXX- XXXXXXXX, (where X may be '0-9' 'A-Z' 'a-z' '-' or blank; '-' is option)   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2026-06-11 Date of Test: 2026-06-16 to 2026-07-03 Date of Issue: 2026-07-03 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Report No.: KSCR260600140102 Page: 2 of 167 TRF No. CONN_001 A_Jun 1st ,2026 Revision Record Version Description Date Remark 00 Original 2026-07-03 / Authorized for issue by: Prepared By Maker_Qi/Project Engineer Approved By Terry Hou /Reviewer Report No.: KSCR260600140102 Page: 3 of 167 TRF No. CONN_001 A_Jun 1st ,2026 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Test Lab* Antenna Requirement 47 CFR Part 15, …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hu Zhao
[email protected]Fax: 18167175029

Technical Contact

United Consulting Technology Services Co., Ltd.David Wu
[email protected]

17800 CASTLETON ST STE 665 · INDUSTRY, 91748 · United States

Test Firm

Compliance Certification Services (Kunshan) Inc.Jessica Chen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.00 mW
215C2.41 GHz - 2.46 GHz186.00 mW
315C2.42 GHz - 2.45 GHz195.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz BW mode in 2.4G WLAN transmitter.

Other Applications from KeyLife International Technology Limited

Indoor Wi-Fi Dual-lens PT Camera - FCC ID 2BHGF-0235CCUY - KeyLife International Technology Limited
2BHGF-0235CCUY

Indoor Wi-Fi Dual-lens PT Camera

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
Indoor Camera - FCC ID 2BHGF-0235CC1B - KeyLife International Technology Limited
2BHGF-0235CC1B

Indoor Camera

Feb 11, 2026

Equipment Class

DTS - Digital Transmission System
Indoor Camera - FCC ID 2BHGF-0235CC1A - KeyLife International Technology Limited
2BHGF-0235CC1A

Indoor Camera

Feb 11, 2026

Equipment Class

DTS - Digital Transmission System