Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL Note: Please read this product manual carefully before installing or using our products Model:S1 Users Manual Thank you for purchasing this fitness vibration machine. Please read the User Manual carefully to ensure safe and proper use of this machine. Please read and fully understand the Safety Precautions before use. Scan the OR code to get after-sales service - WARNINGTo reduce the risk of personal injury, read and understand all the instructions before using this product. Thank you for purchasing our product! If you have any questions about the product, need operational guidance, or encounter any quality issues, please feel free to contact us via the following Customer service email: email address. Our professional customer service team is here to assist you. [email protected] To help us process your inquiry more efficiently, please include your Order ID or Product Serial Number in your email. Customer Service & Support - For Household/Residential Use Only. -WARNINGRemove the control box when the product is not in use, and -WARNINGRisk of personal injuryKeep children under the age of 13 away from machine. store it in an area inaccessible to children. 01 02 1.Important Safety Instructions 05-06 CONTENTS 07 0 2.Grounding Instructions 5.Cleaning and Maintenance 6.Menu and Remote Control 7.Troubleshooting 8 8.Storage and Transportation 3.Introduction 4.Product Features 03 04 04 9.Bluetooth Connection 08 When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using (this appliance). 01 1.IMPORTANT SAFETY INSTRUCTIONS – To reduce the risk of electric shock and the injury from moving parts: 1) Always unplug this appliance from the electrical outlet immediately after using and before cleaning or servicing. DANGER SAVE THESE INSTRUCTIONS – To reduce the risk of burns, fire, electric shock, or injury to persons: 1) An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking off parts. 2) This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Keep children under the age of 13 away from this machine. 3) Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 4) Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a service center for examination and repair. 5) Do not carry this appliance by supply cord or use cord as a handle. 6) Keep the cord away from heated surfaces. 7) Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like. 8) Never drop or insert any object into any opening. 9) Do not use outdoors. Household use only. 10) Do not operate where aerosol (spray) products are being used or where oxygen is being administered. 11) To disconnect, turn all controls to the off position, then remove plug from outlet. 12) Do not operate under blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons. 13) Connect this appliance to a properly grounded outlet only. See Grounding Instructions. 14) Remove control box (or key, or safety pin, as applicable) when not in use, and store out of reach of children. WARNING 02 2.GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. b) For a grounded, cord-connected product rated less than 15 A and intended for use on a nominal 120-V supply circuit, the instructions in either (1) or (2): 1) This product is for use on a nominal 120-V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure 86.1. A temporary adapter that looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw. 2) This product is for use on a nominal 120-V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 86.1. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. 3.INTRODUCTION Model: Product Name: Vibration Platform Machine S1 Product Size: 63 Trademark: Kalietel *38.5*12CM Input: Net Weight/Gros s Weight: 7.9kg/9.0kg 120V~, 60Hz, 2A Maximum Weight Capacity: 350lbs Speed range: 1-2 0levels Amplitude: 0-15 mm O utline Dimension:66*43*14.5cm Manufacture Date: 06/15/2026 Exporting Country:China Importer: Adress: Room 506, 5th Floor, Block 3, Section 2, Fuhe Road, Huay…
Text truncated - open the document above for the full version.
Rev 1/26/2023 NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-08-28 FCC ID: 2BKEQ-S1 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Applicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Contact Person: Andy Wei Tel.: 18123653842 Email: [email protected] Sincerely, Signature:
Attestation Statements Date: 2026-08-28 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2BKEQ-S1) NINGBO LFLY HEALTH TECHNOLOGY CO., LTD., the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated agent for service of process, NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Contact Name: Andy Wei Address: No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Telephone No: 18123653842 Email: [email protected] FRN: 0031072531 Signature: Andy Wei Signa Agent Information: Company Name:HOPEK CORPORATION INC Address:16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN:0034562900 Contact Name:YangyangXu Telephone No:561-875-9826 Email:[email protected] ture: Yangyang Xu
NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 28, 2026 Subject; Request for Confidentiality FCC ID: 2BKEQ-S1 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Andy Wei Title: Manager
Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Date:2026-08-28 Product Model Number: S1, S2, S3, S4, S5, S6, S7 FCC ID:2BKEQ-S1 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Andy Wei Contact Listed on FCC Wesbite Title: Manager Email: [email protected] On behalf of: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD.
NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Declaration Letter of Model Difference Date: 2026-08-28 FCC ID: 2BKEQ-S1 Tested Model Number: S1 Adding Model Number(s): S2, S3, S4, S5, S6, S7 All Adding Model Number(s) is/are same electrically identical as Tested Model Number. Only the model number, housing shape and color are different. Yours Sincerely, Applicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, China Contact Person: Andy Wei Tel.: 18123653842 Email: [email protected] Sincerely, Signature:
Page 1 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Model: S1 Photo 1 Photo 2 Page 2 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 7 Photo 8 Page 5 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 9 Model: S2 Photo 10 Page 6 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 11 Model: S3 Photo 12 Page 7 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 13 Model: S4 Photo 14 Page 8 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 15 Model: S5 Photo 16 Page 9 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 17 Model: S6 Photo 18 Page 10 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 19 Model: S7 Photo 20 Page 11 of 11 Report No.: LGT26H008 Appendix - External Photographs of EUT Constructional Details Photo 21
Label
Page 1 of 3 Report No.: LGT26H008 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 3 Report No.: LGT26H008 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 ANT Page 3 of 3 Report No.: LGT26H008 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: Vibration Platform Machine Model Number: S1, S2, S3, S4, S5, S6, S7 FCC ID: 2BKEQ-S1 Issued For : NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, 315177 Zhejiang, P.R. China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H008HA01 Sample Received Date: Aug. 06, 2026 Date of Test: Aug. 06, 2026 ~ Aug. 19, 2026 Date of Issue: Aug. 19, 2026 Report No.: LGT26H008HA01 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, 315177 Zhejiang, P.R. China Manufacturer: Chengdu Mingyu Xinchuan E-commerce Co., Ltd. Address: Room 506, 5th Floor, Block 3, Section 2, Fuhe Road, Huayang Subdistrict, Tianfu New Area, Chengdu, Sichuan Province, 610213, CN Product Name: Vibration Platform Machine Trademark: N/A Model Number: S1, S2, S3, S4, S5, S6, S7 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1093 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Chris Chen Engineer Technical Director Report No.: LGT26H008HA01 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1093 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 TEST RESULT 8 Report No.: LGT26H008HA01 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Aug. 19, 2026 Initial Issue Report No.: LGT26H008HA01 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Vibration Platform Machine Test Model Number: S1 Series Number: S2, S3, S4, S5, S6, S7 Model Difference: Only the model number, housing shape and color are different. Frequency Bands: Bluetooth 2402-2480MHz Rating: Input: 120V~, 60Hz, 2A Hardware Version: N/A Software Version: N/A 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT26H008HA01 Page 6 of 8 2. FCC 47CFR §2.1093 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in KDB 447498 D01 General RF Exposure Guidance v06 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. Report No.: LGT26H008HA01 Page 7 of 8 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Report No.: LGT26H008HA01 Page 8 of 8 2.3 TEST RESULT Turn up Result Mode Turn up Power BT-GFSK 8±1dBm BT-π/4-DQPSK 8±1dBm BT-8DPSK 8.5±1dBm The MPE result of worst mode: RF Function Frequency (MHz) Max Turn up Power (dBm) Max Turn up Power (mW) Estimated SAR Limit Ratio Result BT 2441 9.50 8.91 2.785 3 0.928 Pass Note: The Maximum Power Density is less than the limit, complies with the exemption requirements. ※※※※※END OF THE REPORT※※※※※
Manufacturer: Chengdu Mingyu Xinchuan E-commerce Co., Ltd. Address: Room 506, 5th Floor, Block 3, Section 2, Fuhe Road, Huayang Subdistrict, Tianfu New Area, Chengdu, Sichuan Province, 610213, CN 1 AverageGain(dB)-4.5(AvgGainXY-plane) Antennamodule&Size AntennaGain GainTable [email protected] XZ-planeYZ-plane Efficiency Peak Avg Peak Avg XY-p Peak -2.9-3. lane Avg -4.5 7-6.9-2.9-6.126.03% 2 3 3Dradiationpatterndiagram XY-plane 4 XZ-plane YZ-plane 4
The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 80 RF TEST REPORT Product Name: Vibration Platform Machine Model Number: S1, S2, S3, S4, S5, S6, S7 FCC ID: 2BKEQ-S1 Issued For : NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, 315177 Zhejiang, P.R. China Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT26H008RF01 Sample Received Date: Aug. 06, 2026 Date of Test: Aug. 06, 2026 ~ Aug. 19, 2026 Date of Issue: Aug. 19, 2026 Report No.: LGT26H008RF01 Page 2 of 80 TEST REPORT CERTIFICATION Applicant: NINGBO LFLY HEALTH TECHNOLOGY CO., LTD. Address: No.5, Industrial Avenue, Industrial Zone, Sanxing Village, Gulin Town, Haishu District, Ningbo, 315177 Zhejiang, P.R. China Manufacturer: Chengdu Mingyu Xinchuan E-commerce Co., Ltd. Address: Room 506, 5th Floor, Block 3, Section 2, Fuhe Road, Huayang Subdistrict, Tianfu New Area, Chengdu, Sichuan Province, 610213, CN Product Name: Vibration Platform Machine Trademark: N/A Model Number: S1, S2, S3, S4, S5, S6, S7 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.247, Subpart C ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT26H008RF01 Page 3 of 80 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST LABORATORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 FREQUENCY HOPPING SYSTEM REQUIREMENTS 10 2.4 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 12 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 12 2.6 EQUIPMENTS LIST 13 3. EMC EMISSION TEST 15 3.1 CONDUCTED EMISSION MEASUREMENT 15 3.2 RADIATED EMISSION MEASUREMENT 19 4. CONDUCTED SPURIOUS & BAND EDGE EMISSION 30 4.1 LIMIT 30 4.2 TEST PROCEDURE 30 4.3 TEST SETUP 30 4.4 EUT OPERATION CONDITIONS 31 4.5 TEST RESULTS 31 5. NUMBER OF HOPPING CHANNEL 32 5.1 LIMIT 32 5.2 TEST PROCEDURE 32 5.3 TEST SETUP 32 5.4 EUT OPERATION CONDITIONS 32 5.5 TEST RESULTS 32 6. AVERAGE TIME OF OCCUPANCY 33 6.1 LIMIT 33 6.2 TEST PROCEDURE 33 6.3 TEST SETUP 33 6.4 EUT OPERATION CONDITIONS 33 6.5 TEST RESULTS 33 7. HOPPING CHANNEL SEPARATION MEASUREMEN 34 7.1 LIMIT 34 7.2 TEST PROCEDURE 34 Report No.: LGT26H008RF01 Page 4 of 80 7.3 TEST SETUP 34 7.4 EUT OPERATION CONDITIONS 34 7.5 TEST RESULTS 34 8. BANDWIDTH TEST 35 8.1 LIMIT 35 8.2 TEST PROCEDURE 35 8.3 TEST SETUP 35 8.4 EUT OPERATION CONDITIONS 35 8.5 TEST RESULTS 35 9. OUTPUT POWER TEST 36 9.1 LIMIT 36 9.2 TEST PROCEDURE 36 9.3 TEST SETUP 36 9.4 EUT OPERATION CONDITIONS 36 9.5 TEST RESULTS 36 10. ANTENNA REQUIREMENT 37 10.1 STANDARD REQUIREMENT 37 10.2 EUT ANTENNA 37 APPENDIX I - TEST RESULTS 38 DUTY CYCLE 38 MAXIMUM PEAK CONDUCTED OUTPUT POWER 42 -20DB BANDWIDTH 46 OCCUPIED CHANNEL BANDWIDTH 50 CARRIER FREQUENCIES SEPARATION 54 BAND EDGE 58 BAND EDGE(HOPPING) 63 CONDUCTED RF SPURIOUS EMISSION 68 NUMBER OF HOPPING CHANNEL 75 DWELL TIME 77 APPENDIX II - MEASUREMENT PHOTOS 80 Report No.: LGT26H008RF01 Page 5 of 80 Revision History Rev. Issue Date Revisions 00 Aug. 19, 2026 Initial Issue Report No.: LGT26H008RF01 Page 6 of 80 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247(a)(1) Hopping Channel Separation PASS -- 15.247(a)(1)&(b)(1) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247(d) Conducted Spurious & Band Edge Emission PASS -- 15.247(a)(1)(iii) Number of Hopping Frequency PASS -- 15.247(a)(1)(iii) Dwell Time PASS -- 15.247(a)(1) Bandwidth PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024. Report No.: LGT26H008RF01 Page 7 of 80 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB 9 All Emissions, Radiated (18GHz-40GHz) ±4.31dB 10 Temperature ±0.5°C 11 Humidity ±2% 12 Duty Cycle ±2.3% Note: The measurement uncertainty is not included in the test result. Report No.: LGT26H008RF01 Page 8 of 80 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Vibration Platform Machine Test Model Number: S1 Series Number: S2, S3, S4, S5, S6, S7 Model Diff…
Text truncated - open the document above for the full version.
Report No.: LGT26H008RF01 Page 57 of 80 CFS NVNT 3-DH5 2402MHz CFS NVNT 3-DH5 2441MHz CFS NVNT 3-DH5 2480MHz Report No.: LGT26H008RF01 Page 58 of 80 Band Edge Condition Mode Frequency (MHz) Hopping Mode Max Value (dBc) Limit (dBc) Verdict NVNT 1-DH5 2402 No-Hopping -57.93 -20 Pass NVNT 1-DH5 2480 No-Hopping -62.9 -20 Pass NVNT 2-DH5 2402 No-Hopping -57.6 -20 Pass NVNT 2-DH5 2480 No-Hopping -63.97 -20 Pass NVNT 3-DH5 2402 No-Hopping -58.83 -20 Pass NVNT 3-DH5 2480 No-Hopping -64.56 -20 Pass Report No.: LGT26H008RF01 Page 59 of 80 Test Graphs Band Edge NVNT 1-DH5 2402MHz No-Hopping Ref Band Edge NVNT 1-DH5 2402MHz No-Hopping Emission Band Edge NVNT 1-DH5 2480MHz No-Hopping Ref Report No.: LGT26H008RF01 Page 60 of 80 Band Edge NVNT 1-DH5 2480MHz No-Hopping Emission Band Edge NVNT 2-DH5 2402MHz No-Hopping Ref Band Edge NVNT 2-DH5 2402MHz No-Hopping Emission Report No.: LGT26H008RF01 Page 61 of 80 Band Edge NVNT 2-DH5 2480MHz No-Hopping Ref Band Edge NVNT 2-DH5 2480MHz No-Hopping Emission Band Edge NVNT 3-DH5 2402MHz No-Hopping Ref Report No.: LGT26H008RF01 Page 62 of 80 Band Edge NVNT 3-DH5 2402MHz No-Hopping Emission Band Edge NVNT 3-DH5 2480MHz No-Hopping Ref Band Edge NVNT 3-DH5 2480MHz No-Hopping Emission Report No.: LGT26H008RF01 Page 63 of 80 Band Edge(Hopping) Condition Mode Frequency (MHz) Hopping Mode Max Value (dBc) Limit (dBc) Verdict NVNT 1-DH5 2402 Hopping -60.97 -20 Pass NVNT 1-DH5 2480 Hopping -62.78 -20 Pass NVNT 2-DH5 2402 Hopping -63.33 -20 Pass NVNT 2-DH5 2480 Hopping -61.27 -20 Pass NVNT 3-DH5 2402 Hopping -63.79 -20 Pass NVNT 3-DH5 2480 Hopping -60.01 -20 Pass Report No.: LGT26H008RF01 Page 64 of 80 Test Graphs Band Edge(Hopping) NVNT 1-DH5 2402MHz Hopping Ref Band Edge(Hopping) NVNT 1-DH5 2402MHz Hopping Emission Band Edge(Hopping) NVNT 1-DH5 2480MHz Hopping Ref Report No.: LGT26H008RF01 Page 65 of 80 Band Edge(Hopping) NVNT 1-DH5 2480MHz Hopping Emission Band Edge(Hopping) NVNT 2-DH5 2402MHz Hopping Ref Band Edge(Hopping) NVNT 2-DH5 2402MHz Hopping Emission Report No.: LGT26H008RF01 Page 66 of 80 Band Edge(Hopping) NVNT 2-DH5 2480MHz Hopping Ref Band Edge(Hopping) NVNT 2-DH5 2480MHz Hopping Emission Band Edge(Hopping) NVNT 3-DH5 2402MHz Hopping Ref Report No.: LGT26H008RF01 Page 67 of 80 Band Edge(Hopping) NVNT 3-DH5 2402MHz Hopping Emission Band Edge(Hopping) NVNT 3-DH5 2480MHz Hopping Ref Band Edge(Hopping) NVNT 3-DH5 2480MHz Hopping Emission Report No.: LGT26H008RF01 Page 68 of 80 Conducted RF Spurious Emission Condition Mode Frequency (MHz) Max Value (dBc) Limit (dBc) Verdict NVNT 1-DH5 2402 -63.3 -20 Pass NVNT 1-DH5 2441 -64.63 -20 Pass NVNT 1-DH5 2480 -65.36 -20 Pass NVNT 2-DH5 2402 -64.2 -20 Pass NVNT 2-DH5 2441 -62.42 -20 Pass NVNT 2-DH5 2480 -65.59 -20 Pass NVNT 3-DH5 2402 -64.22 -20 Pass NVNT 3-DH5 2441 -65.59 -20 Pass NVNT 3-DH5 2480 -65.22 -20 Pass Report No.: LGT26H008RF01 Page 69 of 80 Test Graphs Tx. Spurious NVNT 1-DH5 2402MHz Ref Tx. Spurious NVNT 1-DH5 2402MHz Emission Tx. Spurious NVNT 1-DH5 2441MHz Ref Report No.: LGT26H008RF01 Page 70 of 80 Tx. Spurious NVNT 1-DH5 2441MHz Emission Tx. Spurious NVNT 1-DH5 2480MHz Ref Tx. Spurious NVNT 1-DH5 2480MHz Emission Report No.: LGT26H008RF01 Page 71 of 80 Tx. Spurious NVNT 2-DH5 2402MHz Ref Tx. Spurious NVNT 2-DH5 2402MHz Emission Tx. Spurious NVNT 2-DH5 2441MHz Ref Report No.: LGT26H008RF01 Page 72 of 80 Tx. Spurious NVNT 2-DH5 2441MHz Emission Tx. Spurious NVNT 2-DH5 2480MHz Ref Tx. Spurious NVNT 2-DH5 2480MHz Emission Report No.: LGT26H008RF01 Page 73 of 80 Tx. Spurious NVNT 3-DH5 2402MHz Ref Tx. Spurious NVNT 3-DH5 2402MHz Emission Tx. Spurious NVNT 3-DH5 2441MHz Ref Report No.: LGT26H008RF01 Page 74 of 80 Tx. Spurious NVNT 3-DH5 2441MHz Emission Tx. Spurious NVNT 3-DH5 2480MHz Ref Tx. Spurious NVNT 3-DH5 2480MHz Emission Report No.: LGT26H008RF01 Page 75 of 80 Number of Hopping Channel Condition Mode Hopping Number Limit Verdict NVNT 1-DH5 79 15 Pass NVNT 2-DH5 79 15 Pass NVNT 3-DH5 79 15 Pass Report No.: LGT26H008RF01 Page 76 of 80 Test Graphs Hopping No. NVNT 1-DH5 2441MHz Hopping No. NVNT 2-DH5 2441MHz Hopping No. NVNT 3-DH5 2441MHz Report No.: LGT26H008RF01 Page 77 of 80 Dwell Time Condition Mode Frequency (MHz) Pulse Time (ms) Total Dwell Time (ms) Burst Count Period Time (ms) Limit (ms) Verdict NVNT 1-DH5 2441 2.887 320.457 111 31600 400 Pass NVNT 2-DH5 2441 2.891 312.228 108 31600 400 Pass NVNT 3-DH5 2441 2.894 318.34 11…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 8.50 mW |

Exercise Bike
Equipment Class
DTS - Digital Transmission System
Treadmill
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter