
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CERAGEM PAUSE M4 USER MANUAL CERAGEM PAUSE M4 USER MANUAL CGM EMCG-2601 Copyright CERAGEM. All rights reserved. USER GUIDE CERAGEM PAUSE M4 USER MANUAL USER GUIDE 04 08 09 10 12 13 18 19 20 21 22 01 02 03 04 05 06 07 08 09 10 11 CERAGEM PAUSE M4 USER MANUAL • In order to use the product safely and correctly, be sure to read this user manual before first use. • Always keep this manual on hand and refer to it as necessary. Precautions for Safety Moving and Installation Name of Each Part and Components Name and Description of the Built-in Controller Massage Programs Using the Massage Chair Maintaining and Storing Troubleshooting FAQ Customer Service Product Specifications 0405CERAGEM PAUSE M4CERAGEM PAUSE M4CGM EMCG-2601 01. Precautions for Safety • If the product does not move or operates abnormally, immediately unplug the power plug from the wall outlet and ask the Customer Service Center to check or repair the product. → Failure to do so may cause fire or electric shock due to electric leakage or shorting. • If the product cover is torn or removed, your clothes or hair may get caught, resulting in a serious accident, so check that there is no abnormality visible on the exterior of the product. If the product is damaged in any way, contact the Customer Service Center. → Failure to do so may cause electric shock or injury. • Supervise your children in avoiding touch- ing the power plug. → Failure to do so may cause electric shock or injury. • Do not forcibly bend the power cord or allow it to be compressed and damaged by a heavy object. → Failure to do so may cause fire or electric shock. • When using a power strip, do not use a number of devices connected to the power strip at the same time. → There is a risk of fire due to abnormal Temperature of the power outlet. • When unplugging the power plug, hold the plug, not the cord, and unplug it from the outlet. → If the power cord snaps, there is a risk of fire or electric shock. • Do not touch the power plug with wet hands, and be sure to unplug the power plug from the outlet when cleaning or repairing the product. → Failure to do so may cause electric shock. • When using a power strip, be sure to use a grounded power outlet. → Using an ungrounded outlet may cause electric shock or injury. • In a case of power failure, immediately turn off the power switch and unplug the power plug from the outlet. → Failure to do so may cause electric shock or fire. • Check the connection of the grounding conductor. (Improper connection may cause damage or electric shock.) Grounding Instructions • This is a Class I device equipped with a grounding-type plug. Connect it only to a properly grounded outlet. (Connecting to an ungrounded outlet may result in electric shock.) • Do not remove or alter the grounding pin. (If proper grounding is not provided, leakage current protection may not operate.) • When using an extension cord or a power strip, use only products equipped with a grounding terminal. Anyone with reduced physical, sensory or mental capabilities, or who lacks the appropriate experience or training (including children) must use this product under the supervision of their guardian who bears responsibility for their safety. Children should be supervised to ensure that they do not play with the product. The following precautions for safety are to prevent unexpected risks or damage in advance through safe and correct use of the product. • Never modify, disassemble or repair the product; it must be done by a qualified service technician. → Doing so may cause fire or electric shock. • Use the product on a flat surface. → Failure to do so may cause a product failure or an accident. When Installing Power-related 0607CERAGEM PAUSE M4CERAGEM PAUSE M4CGM EMCG-2601 • Do not use or store the product in damp areas, such as a bathroom. → Doing so may cause electric shock, fire, product failure or the growth of mold. • Do not allow children to play or climb on top of the massage chair. → Failure to do so may cause product failure or injury. • Do not use the product while wearing a hard object, such as a hair accessory, etc., on your head. → Doing so may cause injury. • The duration of use should be no more than 30 minutes per day, and continuous use of the product on the same area should be no more than 5 minutes. → Use of the product for a long period of time may cause straining of your muscles or nerves. • When massaging your hips, do not use the product with any object in your pants' pockets. → Doing so may cause an accident or injury. • Check if the power cord is appropriately and safely positioned before use. → Failure to do so may cause an accident, injury or product failure. • Do not use the product near fires, such as a heater, etc., or while smoking a cigarette. Also, do not use the product on top of Temperature apparatus, such as an electric pad, etc. → Doing so may cause fire. • This product has a Temperature surface. Anyone who is insensitive to the application of heat must pay attention regarding the chance of low temperature burns. • During massage operation, do not unplug the power plug from the outlet or turn the power switch [OFF]. → Doing so may cause injury. • Do not use the product after drinking alcohol. → Doing so may result in an accident or injury. • Do not allow more than two persons to sit on the product or to use it at the same time. → Doing so may cause product failure or injury. • Do not use the product on bare skin. → Doing so may cause skin damage. • When cleaning or repairing the product, unplug the power plug from the outlet. → Failure to do so may cause electric shock or injury. • The surface of the product may be hot. Anyone with sensitive skin must set a lower temperature on the product. → Failure to do so may cause low temperature burns. When Using the Product As there is a risk of accidents related to unsafe use, the following persons should avoid using the massage chair. (1) The following patients must not use the product: • …
Text truncated - open the document above for the full version.
ShandongKangtaiIntelligentTechnologyCo.,Ltd. Address:No.98,EastChushanRoad,ZhaoyuanCity,Shandong,China265400 ChinaDate:2026-05-07 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BLGG-CGMEMCG-2601 FRN:0032731069 (“ShandongKangtaiIntelligentTechnologyCo.,Ltd.”)certifiesthat,asofthedateofthefiling oftheapplication,GOLDENVICTORYINTERNATIONALTRADINGCOLTDisour designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID.(“Shandong KangtaiIntelligentTechnologyCo.,Ltd.”)acceptstomaintainanagentfornolessthanone yearafterthegranteehasterminatedallmarketingandimportationortheconclusionofany Commission-relatedproceedinginvolvingtheequipment. GOLDENVICTORYINTERNATIONALTRADINGCOLTDaccepts,asofthedateofthefiling oftheapplication,theobligationofthedesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GOLDENVICTORYINTERNATIONALTRADINGCOLTD Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates FRN:0036377570 ContactPerson:LeonHowar Tel.:(337)255-0461 Email:[email protected] Sincerely, Signedonbehalfof(ShandongKangtai IntelligentTechnologyCo.,Ltd.) SignedonbehalfofGOLDENVICTORY INTERNATIONALTRADINGCOLTD Name:TongyuXuName:LeonHowar Title:CertificationManagerTitle:Manager Date:2026-05-07Date:2026-05-07
Rev1/26/2023 (ShandongKangtaiIntelligentTechnologyCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:5-7-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BLGG-CGMEMCG-2601 (“ShandongKangtaiIntelligentTechnologyCo.,Ltd.”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. (“ShandongKangtaiIntelligentTechnologyCo.,Ltd.”)certifiesthattheequipmentforwhich authorizationissoughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedby KasperskyLab,Inc.oranyofitssuccessorsandassignees,includingequipmentwithintegratedKaspersky Lab,Inc.(oranyofitssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24- 886andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):TongyuXu Rev1/26/2023 (ShandongKangtaiIntelligentTechnologyCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:5-7-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BLGG-CGMEMCG-2601 (“ShandongKangtaiIntelligentTechnologyCo.,Ltd.”)certifiesthat,asofthedateofthefilingofthe application,ShandongKangtaiIntelligentTechnologyCo.,Ltd.isnotidentifiedontheCoveredList(asa specificallynamedentityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. Sincerely, (Applicantsignature): (Applicantprintedname):TongyuXu
ShandongKangtaiIntelligentTechnologyCo.,Ltd. Date:May7,2026 ProductModelNumber:CGMEMCG-2601 FCCID : 2BLGG-CGMEMCG-2601 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:CertificationManager Email:[email protected] Telephone:+860535-8243990 Onbehalfof:ShandongKangtaiIntelligentTechnologyCo.,Ltd.
ShandongKangtaiIntelligentTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:May7,2026 Subject;RequestforConfidentiality FCCID:2BLGG-CGMEMCG-2601 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:TongyuXu Title:CertificationManager
FCCID:2BLGG-CGMEMCG-2601 EUTPHOTOSExternalPhotos FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 ※※※※※ENDOFREPORT※※※※※
Size:70mmX70mm 、
FCCID:2BLGG-CGMEMCG-2601 EUTPHOTOSInternalPhotos FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 FCCID:2BLGG-CGMEMCG-2601 ANT FCCID:2BLGG-CGMEMCG-2601 ※※※※※ENDOFREPORT※※※※※
FCCID:2BLGG-CGMEMCG-2601 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 , Unless specificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposureconditions,by measurementornumericalsimulation,isnotrequiredwhenthecorrespondingSARTest ExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≤50mm,the1-gand10-gSARtest exclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]·[√f (GHz) ]≤3.0for1-gSAR,and≤7.5for10-gextremitySAR,where f (GHz) istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison Here, ForBluetooth Mode Max Power (dBm) Tune-up power (dBm) Max Power (mW) Frequency(MHz) Min. Distance (mm) Calc. thresholds limit BT0.70±11.26248050.3973.0 BLE00±11.26248050.3973.0 ThedevicecouldnotsupporttransmissionwithBLE,BTsimultaneously, SoaSARtestisnotrequired.
AntennaSpecifications ITEMANTSPEC ModelNamePASSIVE2.4G CenterFrequency2400MHz2450MHz2500MHz Gain(dBi)-0.420-0.89 MAX.Gain0dBi AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength11.9mm AntennaTypePCBantenna ManufactureShandongKangtaiIntelligentTechnologyCo.,Ltd. Address No.98,EastChushanRoad,ZhaoyuanCity,Shandong, China265400 1.AntennaPhoto&Length(mm) 2.Passivetestdata Frequency(MHz)Effi(%)Gain(dBi) 240042.86-0.42 241042.25-1.32 242043.23-1.27 243045.04-0.59 244045.42-0.17 245044.260 246044.78-0.76 247044.49-1.44 248042.27-1.25 249041.88-1.36 250042.73-0.87 3.Directionaldiagram
ProjectNo.:ZHT-260116120W01-2 Page 1 of 51 FCCTESTREPORT FCCID:2BLGG-CGMEMCG-2601 ApplicantName...............:ShandongKangtaiIntelligentTechnologyCo.,Ltd. Address............................:No.98,EastChushanRoad,ZhaoyuanCity,Shandong,China265400 ManufacturerName.........:ShandongKangtaiIntelligentTechnologyCo.,Ltd. Address............................:No.98,EastChushanRoad,ZhaoyuanCity,Shandong,China265400 Product............................:MassageChair Model(s)...........................:CGMEMCG-2601 AdditionalModel(s)..........:/ Trademark........................:/ ModelDifference..............:/ Preparedby......................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Jan.16,2026 DateofTest(s)..................:Jan.16,2026toApr.23,2026 DateofIssue....................:Apr.23,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260116120W01-2 Page 2 of 51 TableofContentsPage 1.SUMMARYOFTESTRESULTS...............................................................................4 2.GENERALINFORMATION........................................................................................5 2.1GENERALDESCRIPTIONOFEUT.................................................................................5 2.2DESCRIPTIONOFTESTMODES....................................................................................6 2.3TESTSETUPCONFIGURATION......................................................................................7 2.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)........................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED...................................................8 3.1TESTFACILITY.................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS...................................................................8 3.3TESTINGSOFTWARE......................................................................................................9 3.4MEASUREMENTUNCERTAINTY..................................................................................10 4.EMCEMISSIONTEST.............................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT..................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits...................................................11 4.1.2TESTPROCEDURE................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................11 4.1.4TESTSETUP...........................................................................................................12 4.1.5EUTOPERATINGCONDITIONS...........................................................................12 4.1.6TESTRESULTS......................................................................................................13 4.2RADIATEDEMISSIONMEASUREMENT......................................................................14 4.2.1RADIATEDEMISSIONLIMITS...............................................................................15 4.2.2TESTPROCEDURE...............................................................................................15 4.2.3DEVIATIONFROMTESTSTANDARD..................................................................16 4.2.4TESTSETUP...........................................................................................................16 4.2.5EUTOPERATINGCONDITIONS...........................................................................17 5.RADIATEDBANDEMISSIONMEASUREMENT....................................................22 5.1TESTREQUIREMENT:..............................................................................................22 5.2TESTPROCEDURE..................................................................................................22 5.3DEVIATIONFROMTESTSTANDARD.....................................................................23 5.4TESTSETUP..............................................................................................................23 5.5EUTOPERATINGCONDITIONS..............................................................................23 5.6TESTRESULT...........................................................................................................24 6.POWERSPECTRALDENSITYTEST.....................................................................25 6.1APPLIEDPROCEDURES/LIMIT.............................................................................25 ProjectNo.:ZHT-260116120W01-2 Page 3 of 51 TableofContents Page 6.2TESTPROCEDURE..................................................................................................25 6.3DEVIATIONFROMSTANDARD...............................................................................25 6.4TESTSETUP..............................................................................................................25 6.5EUTOPERATIONCONDITIONS..............................................................................25 6.6TESTRESULTS.............................................................…
Text truncated - open the document above for the full version.
FCCID:2BLGG-CGMEMCG-2601 EUTTESTPHOTOS FCCID:2BLGG-CGMEMCG-2601 ※※※※※ENDOFREPORT※※※※※
110 16TH STREET SUITE 1400 DENVER, · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |