FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SIPAV S.r.l./
  3. 2BPBF-02CES10

2BPBF-02CES10Sensor

SIPAV S.r.l.
Sensor - FCC ID 2BPBF-02CES10 - SIPAV S.r.l.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Feb 05, 2026
Application Purpose
Original Equipment
Equipment Note
Sensor
Frequency Range
315.00000000 - 315.00000000
Company
SIPAV S.r.l.
Country
Italy

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

① ② ③④⑤ Screw 1 Sensor 2 Valve Stem 3 Nut 4 Valve Cap 5 Step 1Step 2 4.0Nm 35 in-lbs Step 3 1. Remove the valve nut. 2. Pass the valve through the rim hole, and mount the nut, use a torque wrench with 4 Nm. Make sure the valve is seated correctly. 3. Mount the tire, please make sure that the sensor is not damaged during mounting. 4. Remove the valve cap and inflate the tire to the correct tire pressure according to the vehicle specification. Screw the valve cap back on. Please note the vehicle manufacturer-specific learning method, which you can find in the vehicle manual or in our eaSy Sensor programming device. Installation 1. Entfernen Sie die Überwurfmutter. 2. Führen Sie das Ventil durch das Ventilloch, und montieren Sie die Überwurfmutter, nutzen Sie einem Drehmo- mentschlüssel mit 4 Nm. Achten Sie auf den korrekten Sitz des Ventils. 3. Montieren Sie den Reifen, bitte stellen Sie sicher das der Sensor bei der Montage nicht durch die Reifenflanke beschädigt wird (Kontaktlose Montage). 4. Entfernen Sie die Ventilkappe und befüllen Sie das Rad entsprechend der Fahrzeugangaben mit dem korrekten Reifendruck. Schrauben Sie die Ventilkappe wieder auf. Bitte beachten Sie die Fahrzeughersteller spezifische Anlernmetode, diese finden Sie im Fahrzeughandbuch oder in unserem eaSy Sensor Programmiergerät. Installationsanleitungen 1. Retirez l'écrou de serrage. 2. Passez la valve à travers le trou de la jante et montez l'écrou, utilisez une clé dynamométrique de. 4.0Nm.Assurez-vous que la soupape est bien en place. 3. Montez le pneu, assurez-vous que le capteur n'est pas endommagé par la paroi du pneu lors du montage. 4. Retirez le capuchon de valve et gonflez la roue à la bonne pression de pneu selon les spécifications du véhicule. Revissez le capuchon de la valve. Let op de voertuig specifieke in leermethode, die kunt u vinden in de voertuighandleiding of in eaSy Sensor programmeerapparaat. Instructions d'installation 1. Rimuovere il dado della valvola. 2. Far passare la valvola attraverso il foro del cerchio e montare il dado, utilizzando uno strumento dinamometrico con una coppia di serraggio di 4 Nm. Assicurarsi che la valvola sia posizionata correttamente. 3. Montare lo pneumatico, assicurandosi che il sensore non venga danneggiato durante il montaggio. 4. Rimuovere il cappuccio della valvola e gonfiare lo pneumati- co alla pressione corretta secondo le specifiche del veicolo. Riavvitare il cappuccio della valvola. Si prega di verificare il metodo di apprendimento specifico del veicolo, disponibile nel manuale del veicolo o nel nostro dispositivo di diagnosi e riprogrammazione eaSy Sensor. Installazione Installation instructions Sensor with clamp-in valves Caution please: 1. Only original eaSy Sensor valves may be used to mount the sensors. 2. TPMS sensors and valves are safety relevant, so always pay attention to correct use and installation. Installation should only be carried out by qualified specialists or trained persons. Please pay attention to the installation instructions. 3. Depending on the vehicle manufacturer or vehicle model, a programming device or diagnostic tool may need to program the new sensor to the car. Attention, s'il vous plaît: 1. Seules les vannes eaSy Sensor d'origine peuvent être utilisées pour monter les capteurs. 2. Les capteurs et vannes TPMS sont importants pour la sécurité, faites donc toujours attention à une utilisation et une installation correctes. L'installation ne doit être effectuée que par des spécialistes qualifiés ou des personnes formées. Veuillez prêter attention aux instructions d'installation. 3. Selon le constructeur du véhicule ou le modèle du véhicule, un appareil de programmation ou un outil de diagnostic peut avoir besoin de programmer le nouveau capteur sur la voiture. Nota bene: 1. Per il montaggio dei sensori eaSy Sensor si devono utilizzare esclusivamente le valvole originali. 2. I sensori e le valvole TPMS sono rilevanti per la sicurezza, pertanto assicurarsi sempre che vengano utilizzati e installati correttamente. L'installazione può essere eseguita solo da professionisti qualificati o da persone appositamente formate. Si prega di osservare le corrette istruzioni di installazione. 3. A seconda del produttore o del modello del veicolo, potrebbe essere necessario uno strumento di diagnosi e riprogrammazione per programmare il nuovo sensore dell'auto. Achtung: 1. Es dürfen, nur Originale eaSy Sensor Ventile zur Montage der Sensoren verwendet werden. 2. RDKS-Sensoren und Ventile sind Sicherheitsrelevant, achte Sie daher immer auf die korrekte Verwendung und Montage. Die Montage sollte ausschließlich von ausgebildeten Fachkräften oder geschulten Personen durchgeführt werden. Achten Sie bitte auf die Installationshinweise. 3. Je nach Fahrzeughersteller oder Fahrzeug Model ist zum Anlernen ein Programmiergerät erforderlich. (Fahrzeugabhängig) FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifica…

Text truncated - open the document above for the full version.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BPBF-02CES10 02CES10S, 02CES10C, 02CES10B We, Applicant Company Name: SIPAV S.r.l. Address: Via Alfred Bernhard Nobel, 21 Reggio Emilia 42124, Italy Phone: +39-0522-532730 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-02-04 Signature Date Name / Title: Pietro Millenotti / Product Manager Company: SIPAV S.r.l. Address: Via Alfred Bernhard Nobel, 21 Reggio Emilia 42124, Italy Phone: +39-0522-532730 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2BPBF-02CES10 02CES10S, 02CES10C, 02CES10B Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Contact Name: Martion Lee Address: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Phone: +86-755-82591330 Email: [email protected] Signature: Date: 2025-10-22

Cover Letter(s)

SIPAV S.r.l. Via Alfred Bernhard Nobel, 21 Reggio Emilia 42124, Italy Date: February 4, 2026 FCC ID: 2BPBF-02CES10 Model Number: 02CES10S, 02CES10C, 02CES10B To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, SIPAV S.r.l. hereby declare that our product (Sensor) Model Number: 02CES10S, 02CES10C, 02CES10B board, Schematic, Hardware version, Software version, structure and internal photos are same, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Pietro Millenotti / Product Manager Company: SIPAV S.r.l. Address: Via Alfred Bernhard Nobel, 21 Reggio Emilia 42124, Italy Phone: +39-0522-532730 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BPBF-02CES10 02CES10S, 02CES10C, 02CES10B For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-02-04 Signature Date Name / Title: Pietro Millenotti / Product Manager Company: SIPAV S.r.l. Address: Via Alfred Bernhard Nobel, 21 Reggio Emilia 42124, Italy Phone: +39-0522-532730 Fax: N/A E-Mail: [email protected]

External Photos

Page 1 of 3 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 5 Fig. 6

ID Label/Location Info

Page1of1FCCID:2BPBF-02CES10 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com LABELANDLOCATION (Size:L3.0cmxW2.0cm) Sensor Model:02CES10S FCCID:2BPBF-02CES10 LabelLocation

Internal Photos

Page 1 of 5 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 5 Fig. 6 Antenna Page 4 of 5 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2BPBF-02CES10 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 9 Fig. 10

RF Exposure Info

Page1of10FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation For SIPAVS.r.l. Sensor TestModel:02CES10S AdditionalModelNo.:02CES10C,02CES10B Preparedfor:SIPAVS.r.l. Address:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August22,2025 Numberoftestedsamples:2 SampleNo.:C250822005-1,C250822005-2 Serialnumber:Prototype DateofTest:August22,2025~August26,2025 DateofReport:August27,2025 Page2of10FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation ReportReferenceNo......................:LCSC05075029EC DateofIssue.......................................:August27,2025 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure.............:FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:SIPAVS.r.l. Address................................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy TestSpecification Standard..............................................:FCCKDBpublication447498D01GeneralRFExposureGuidance v06 FCCCFR47part11.1310 FCCCFR47part22.1091 TestReportFormNo.......................:TRF-4-E-215A/0 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription......................:Sensor TradeMark..........................................:N/A TestModel...........................................: 02CES10S Ratings.................................................: DC3.0VByCR2050BBattery Result...................................................: PASS Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorJustinZhu/Techniqueprincipal GavinLiang/Manager Page3of10FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation EUT.........................................:Sensor TestModel...........................:02CES10S Applicant...............................:SIPAVS.r.l. Address..................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Manufacturer.......................:SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Factory.......................:SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC05075029EC August27,2025 Dateofissue Page4of10FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August27,2025InitialIssue--- Page5of10FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EC GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS DescriptionPage 1.ProductInformation........................................................................................................................................6 2.EvaluationMethod...........................................................................................................................................7 3.Limit.....................................................................................................................................................................7 4.MPECalculationMethod................................................................................................................................8 5.AntennaInformation........................................................................................................................................8 6.ConductedPower.............................................................................................................................................9 7.MeasurementResults.....................................................................................................................................9 8.Conclusion…

Text truncated - open the document above for the full version.

Test Report

Page1of28FCCID:X2BPBF-02CES10ReportNo.:LCSC05075029EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For SIPAVS.r.l. Sensor TestModel:02CES10S AdditionalModelNo.:02CES10C,02CES10B Preparedfor:SIPAVS.r.l. Address:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August22,2025 Numberoftestedsamples:2 SampleNo. :C250822005-1,C250822005-2 Serialnumber:Prototype DateofTest:August22,2025~August26,2025 DateofReport:August27,2025 Page2of28FCCID:X2BPBF-02CES10ReportNo.:LCSC05075029EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15C(15.231 (e)) ReportReferenceNo. .................. :LCSC05075029EB DateofIssue .................................... :August27,2025 TestingLaboratoryName...........:GuangzhouLCSComplianceTestingLaboratoryLtd. Address.............................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure......... :FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName..........................:SIPAVS.r.l. Address.............................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy TestSpecification Standard...........................................: FCCPart15.231(e),ANSIC63.10-20 20 TestReportFormNo...................:LCSEMC-1.0 TRFOriginator.................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF ...................................... :Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsource ofthematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwill notassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterial duetoitsplacementandcontext. TestItemDescription..................:Sensor TradeMark.......................................:N/A TestModel.......................................:02CES10S Ratings..............................................:DC3.0VByCR2050BBattery Result...............................................:PASS Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorJustinZhu/TechniqueprincipalGavinLiang/Manager Page3of28FCCID:X2BPBF-02CES10ReportNo.:LCSC05075029EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT EUT.........................................:Sensor TestModel...........................:02CES10S Applicant...............................:SIPAVS.r.l. Address..................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Manufacturer.......................:SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Factory.......................: SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC05075029EB August27,2025 Dateofissue Page4of28FCCID:X2BPBF-02CES10ReportNo.:LCSC05075029EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August27,2025InitialIssue-- Page5of28FCCID:X2BPBF-02CES10ReportNo.:LCSC05075029EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS 1.GENERALINFORMATION....................................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)........................................................................................................................................6 1.2.OBJECTIVE...........................................................................................................................................................................7 1.3.ENVIRONMENTALCONDITIONS...........................................................................................................................................7 1.4.SUPPORTEQUIPMENTLIST................................................................................................................................................7 1.5.EXTERNALI/OPORT...........................................................................................................................................................7 1.6.EUTOPERATION.................................................................................................................................................................8 1.7.ANTENNASYSTEM..........…

Text truncated - open the document above for the full version.

Test Report

Page1of28FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For SIPAVS.r.l. Sensor TestModel:02CES10S AdditionalModelNo.:02CES10C,02CES10B Preparedfor:SIPAVS.r.l. Address:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August22,2025 Numberoftestedsamples:2 SampleNo.:C250822005-1,C250822005-2 Serialnumber:Prototype DateofTest:August22,2025~August26,2025 DateofReport:August27,2025 Page2of28FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15C(15.231 (e)) ReportReferenceNo. .................. :LCSC05075029EA DateofIssue .................................... :August27,2025 TestingLaboratoryName...........:GuangzhouLCSComplianceTestingLaboratoryLtd. Address.............................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure......... :FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName..........................:SIPAVS.r.l. Address.............................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy TestSpecification Standard...........................................: FCCPart15.231(e),ANSIC63.10-20 20 TestReportFormNo...................:LCSEMC-1.0 TRFOriginator.................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF ...................................... :Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsource ofthematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwill notassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterial duetoitsplacementandcontext. TestItemDescription..................:Sensor TradeMark.......................................:N/A TestModel.......................................:02CES10S Ratings..............................................:DC3.0VByCR2050BBattery Result................................................:PASS Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorJustinZhu/TechniqueprincipalGavinLiang/Manager Page3of28FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT EUT.........................................:Sensor TestModel...........................:02CES10S Applicant...............................:SIPAVS.r.l. Address..................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Manufacturer.......................:SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ Factory.......................: SIPAVS.r.l. Address...................................:ViaAlfredBernhardNobel,21ReggioEmilia,42124Italy Telephone...............................:/ Fax..........................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC05075029EA August27,2025 Dateofissue Page4of28FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August27,2025InitialIssue-- Page5of28FCCID:2BPBF-02CES10ReportNo.:LCSC05075029EA GuangzhouLCSComplianceTestingLab…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Pietro Millenotti
[email protected]Fax: +39 0522532730

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place Fullerton, · California, 92835 · United States

Test Firm

Guangzhou LCS Compliance Testing Laboratory LtdAndy Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)315 MHz - 315 MHz-
215.231(e)433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing.