FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Ā© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. MOTIC CHINA GROUP Co., LTD./
  3. 2BPEF-MOTICSCOPE1

2BPEF-MOTICSCOPE1Biological Microscope

MOTIC CHINA GROUP Co., LTD.
Biological Microscope - FCC ID 2BPEF-MOTICSCOPE1 - MOTIC CHINA GROUP Co., LTD.
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jun 26, 2026
Application Purpose
Original Equipment
Equipment Note
Biological Microscope
Frequency Range
5180.00000000 - 5240.00000000
Company
MOTIC CHINA GROUP Co., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MoticScope 1 Biological Microscope Instruction Manual WWW.MOTIC.COM MOTIC CHINA GROUP CO., LTD. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Note Complete reading of this manual before opeartion is required. 1 Contents 1. Safety Instructions3 1.1 Safety Tips3 1.2 Safety Considerations3 1.3 Transportation, Unpacking, and Storage4 1.4 Operating Precautions4 1.5 Working Environment5 1.6 Quality Assurance5 2. Product Overview7 2.1 Intended Use7 2.2 Structural Composition7 3. Product Operation8 3.1 Check the Input Voltage8 3.2 Installation Method9 3.2.1 Eyepieces9 3.2.2 Observation Tube (Complete Digital Head)9 3.2.3 Objective Lenses9 3.3 Routine Microscopic Operat ion10 3.3.1 Power Switch10 3.3.2 Handling and Placement of the Microscope10 3.3.3 Brightness Adjustment10 3.3.4 Stage Adjustment11 3.3.5 Objective Lens Switching11 3.3.6 Focusing12 3.3.7 Condenser Adjustment13 3.3.8 Oil-Immersion Objective Lens13 3.3.9 Extended Interface Functions14 3.4 Digital Microscopy Operation15 3.4.1 Using the Software15 3.4.2 Reset16 3.4.3 Calibration16 4. Maintenance and Care17 2 4.1 Cleaning17 4.1.1 Optical Lens Surfaces17 4.1.2 Surfaces of Painted Parts and Plastic Parts18 4.2 Storage18 4.3 Lamp Replacement18 4.3.1 LED Lamp18 4.4 Maintenance Inspection19 Appendix 1 Troubleshooting Table20 Appendix 2 Technical Specifications Table23 Appendix 3 Product Configuration Table24 3 1. Safety Instructions 1.1 Safety Tips Before using this product, please read the instruction manual carefully to ensure safe operation and optimal performance, and follow all precautions and warnings provided in the manual. Please familiarize yourself with the meanings of the following safety symbols: SymbolDescription Caution: Hazard. Indicates that the instrument may cause personal injury or equipment damage. Caution: Hot Surface Hazard. Indicates that the surface of the instrument may present a risk of burns due to high temperature. Information and Tips. Indicates useful information and guidance. Recycling. Indicates that disposal of instrument waste must be carried out in strict compliance with applicable requirements. Caution: Electric Shock Hazard. Indicates the presence of potentially hazardous voltage/current in the instrument. 1.2 Safety Considerations  This product is designed, manufactured, and inspected in accordance with the safety standards GB/T 42125.1-2024 and YY 0648-2008.  This product complies with the emission and immunity requirements specified in IEC 61326, GB/T 18268.1, and GB/T 18268.26 series standards.  Before using this product, assess the electromagnetic environment. Do not use it near strong sources of electromagnetic radiation, such as unshielded radio-frequency sources, as this may interfere with the normal operation of the equipment.  This product is designed and tested as Class B equipment in accordance with GB 4824. In a domestic environment, the Product may cause radio interference and requires protection.  Please use only the power cord specified by the manufacturer; otherwise, the safety performance of this product may be compromised.  Connect the power cable properly, and ensure that the Product's grounding terminal is properly connected to the grounding terminal of the wall socket. Otherwise, the designed electrical safety performance of this product may be compromised.  Any electronic equipment connected to this product must comply with the requirements of EN/IEC 62368 and other applicable local safety rules and standards.  The characteristics of the biological microscope specified in the registered product standard are: Overvoltage Category II; Pollution Degree 2. 4 1.3 Transportation, Unpacking, and Storage  In accordance with standard commercial practice, this product is transported in corrugated cartons with foam packaging. Please reuse the original packaging for any transportation.  During transportation and storage, protective measures such as shielding from direct sunlight, keeping dry from rain, and preventing impact damage must be taken.  When unpacking, please check all accessories against the packing list to confirm that everything is complete.  For long-term storage or return to the factory, please use the original packaging to avoid voiding the warranty. 1.4 Operating Precautions This product is a precision instrument. Improper handling or operation may impair its performance or cause damage to the instrument. To ensure stable and reliable operation, place the instrument on a firm, secure table or on a workbench equipped with vibration isolation. When using this product, be sure to observe the following precautions at all times.  This product may only be operated by trained personnel. The operator shall understand the hazards associated with biological microscope examination and its various related application fields.  This product is not equipped with any special protective devices for corrosive, potentially infectious, toxic, radioactive, or other health-hazardous samples. When handling such tests, all legal requirements must be observed, especially those relating to accident prevention.  Do not use this product in locations where the disconnect device (switch and power outlet) is difficult to operate.  If it has been determined that the protective function has failed, stop using the product immediately and contact the Motic after-sales technical service department for repair.  Please ensure that this product is placed on a non-metallic work surface so as not to affect its functional performance. Before using immersion oil, be sure to read the following safety precautions carefully.  Immersion oil may irritate the skin. Avoid contact with skin, eyes, and clothing.  After skin contact, wash thoroughly with plenty of water and soap until the immersion oil has been completely removed from the skin.  After eye contact, immediately flush the eyes with plenty of water for at least 5 …

Text truncated - open the document above for the full version.

Test Report

Xiamen Jihe Communication Co., LTD 1 / 12 Specification for Approval Supplier Confirmed CHIEF DESIGN Jack Lee 2025.2.11 2025.2.11 Technical Support If you have any questions about the following Specifications or RF product Keep Call Phone: 18350272787 E - Mail: [email protected] Customer: Motic Part name: WIFI6 Camera-specific Antenna Part No. : ZH100169 Customer Part No. : Customer Approved By APPROVAL CHIEF DESIGN Xiamen Jihe Communication Co., LTD 2 / 12 Catalogue Update of the Records Rev Formulate Date Content 01 Lee 2024.4.15 new 02 Lee 2025.2.11 Add 2.4 data NO Content Page 1 Cover 1 2 Catalog 2 3 Product chart/Assembly 3 4 Characteristics/Match 4 5 OTA darkroom 5 6 efficiency and gain report 6 7 SWR and S parameter 6 8 Isolation 7 9 Directional and 3D diagram 8-11 10 Drawing 12 Xiamen Jihe Communication Co., LTD 3 / 12 Customer product Xiamen Jihe Communication Co., LTD 4 / 12 Antenna performance Antenna match product type FPC antenna DESCRIPTION VALUE Frequency Range 2400~2500&5000~6000 MHz V.S.W.R Air Impedance 50Ī© Gain ANT1:-2.7dBi & 2.0 dBi ANT2:-2.2dBi & 4.6 dBi Radiation Omni-directional Radiating element 1/4 Wave Helical Polarization Linear Vertical Admitted power 2W Connector Ipex Operating temp -40°C~+85°C 0 Ī© Xiamen Jihe Communication Co., LTD 5 / 12 OTA darkroom picture +X -Z -Y -X +Y +Z Xiamen Jihe Communication Co., LTD 6 / 12 efficiency and gain report SWR and S parameter Right Left ANTENNA FREQUENCY EFFICIENCY GAIN FREQUENCY EFFICIENCY GAIN Right 2400 12.5% -3.9 5170 62.7% 2.0 2450 13.1% -3.6 5500 51.6% 1.5 2500 15.1% -2.7 5850 54.7% 1.9 Left 2400 11.2% -3.9 5170 59.2% 2.4 2450 14.9% -3.2 5500 67.2% 4.6 2500 15.2% -2.2 5850 66.4% 3.1 Xiamen Jihe Communication Co., LTD 7 / 12 Isolation Xiamen Jihe Communication Co., LTD 8 / 12 Directional and 3D diagram 3D right 3D left Xiamen Jihe Communication Co., LTD 9 / 12 2D right Xiamen Jihe Communication Co., LTD 10 / 12 2D left Xiamen Jihe Communication Co., LTD 11 / 12 Xiamen Jihe Communication Co., LTD 12 / 12 Drawing

Test Setup Photos

Page 1 of 2 Report No.: psi2602048-C01-R07 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2BPEF-MOTICSCOPE1 Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (ļ¼ž1G) Page 2 of 2 Report No.: psi2602048-C01-R07 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Conducted emission Test ------End------

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 23 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BPEF-MOTICSCOPE1 On Behalf of Motic China Group Co., Ltd. Biological Microscope Model No.: MoticScope 1 Prepared for : Motic China Group Co., Ltd. Address : No.810 Fangshan Nan Road, XiangAn, Xiamen 361100, P.R. China Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2602048-C01-R09 Date of Receipt : March 4, 2026 Date of Test : March 5, 2026– April 21, 2026 Date of Report : April 22, 2026 Version Number : V0 Page 2 of 23 Report No.: psi2602048-C01-R09 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. GENERAL INFORMATION ------------------------------------------------------------------------------------------------- 5 1.1.Description of Device (EUT) ------------------------------------------------------------------------------------------- 5 1.2.Accessories of Device (EUT) ------------------------------------------------------------------------------------------ 6 1.3.Tested Supporting System Details ----------------------------------------------------------------------------------- 6 1.4.Block Diagram of connection between EUT and simulators --------------------------------------------------- 6 2. TEST EQUIPMENT LIST ---------------------------------------------------------------------------------------------------- 7 3. SUMMARY OF MEASUREMENT ----------------------------------------------------------------------------------------- 8 3.1. Summary of test result ---------------------------------------------------------------------------------------------- 8 3.2. Equipment Type ------------------------------------------------------------------------------------------------------ 8 3.3. Channel list ------------------------------------------------------------------------------------------------------------ 9 3.4. Test Conditions and channel ------------------------------------------------------------------------------------ 10 3.5. Measurement Uncertainty (95% confidence levels, k=2) ------------------------------------------------- 10 3.6. Test Facility ---------------------------------------------------------------------------------------------------------- 10 4. DFS PARAMETERS --------------------------------------------------------------------------------------------------------- 11 4.1. DFS Parameters ---------------------------------------------------------------------------------------------------- 11 4.2. Calibration Setup and DFS Test Results --------------------------------------------------------------------- 17 4.2.1. Calibration of Radar Waveform --------------------------------------------------------------------------------- 17 4.2.1.1. Radar Waveform Calibration Procedure ------------------------------------------------------------- 17 4.2.1.2. Conducted Calibration Setup -------------------------------------------------------------------------- 17 4.2.1.3. Calibration Deviation ------------------------------------------------------------------------------------- 17 4.2.1.4. Radar Waveform Calibration Result ------------------------------------------------------------------ 18 4.3. In-Service Monitoring: Channel Move Time, Channel Closing Transmission Time and Non-Occupancy Period ---------------------------------------------------------------------------------------------------- 19 4.3.1. Limit of In-Service Monitoring ----------------------------------------------------------------------------------- 19 4.3.2. Test Procedures ---------------------------------------------------------------------------------------------------- 19 4.3.3. Test Setup --------------------------------------------------------------------------------------------------------------- 20 4.3.4. Test Deviation ----------------------------------------------------------------------------------------------------------- 20 4.3.5. Result of Channel Move Time, Channel Closing Transmission Time and Non-Occupancy Period for Client Beacon Test 20 4.3.6. Channel Move Time, Channel Closing Transmission Time and Non-Occupancy Period for Client Beacon Test Plots ------------------------------------------------------------------------------------------------------------ 21 4.3.7. Data Traffic and Noise Floor Plots ------------------------------------------------------------------------------ 22 5. Photos Of Test Setup ----------------------------------------------------------------------------------------------------- 23 6. Photos Of EUT -------------------------------------------------------------------------------------------------------------- 23 Page 3 of 23 Report No.: psi2602048-C01-R09 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TEST REPORT DECLARATION Applicant : Motic China Group Co., Ltd. Address : No.810 Fangshan Nan Road, XiangAn, Xiamen 361100, P.R. China Manufacturer : Motic China Group Co., Ltd. Address : No.810 Fangshan Nan Road, XiangAn, Xiamen 361100, P.R. China EUT Description : Biological Microscope (A) Model No. : MoticScope 1 (B) Trademark : Motic Measurement Standard Used: FCC Part 15 Subpart E, FCC KDB 905462 D02, FCC KDB 905462 D03 ANSI C63.10-2020+COR.1-2023 Test Result: PASS The device described above is tested by Shenzhen PSI Testing C…

Text truncated - open the document above for the full version.

Test Report

Page 249 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11n(HT40)_Power_Spectral_Density_5755 NVNT_MIMO_TX_802_11n(HT40)_Power_Spectral_Density_5795 Page 250 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11ac(VHT40)_Power_Spectral_Density_5755 NVNT_MIMO_TX_802_11ac(VHT40)_Power_Spectral_Density_5795 Page 251 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11ac(VHT80)_Power_Spectral_Density_5775 Page 252 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China 4.6 Band Edge Test Requirement: FCC Part15 E Section 15.407 and 15.205, RSS-Gen §8.9 Test Method: ANSI C63.10-2020+COR.1-2023 Test site: Measurement Distance: 3m (Semi-Anechoic Chamber) Receiver setup: Frequency Detector RBW VBW Remark 30MHz-1GHz Quasi-peak 100KHz 300KHz Quasi-peak Value Above 1GHz Peak 1MHz 3MHz Peak Value AV 1MHz 3MHz Average Value Limit: Frequency Limit (dBuV/m @3m) Remark 30MHz-88MHz 40.0 Quasi-peak Value 88MHz-216MHz 43.5 Quasi-peak Value 216MHz-960MHz 46.0 Quasi-peak Value 960MHz-1GHz 54.0 Quasi-peak Value Above 1GHz 54.0 Average Value 68.2 Peak Value Undesirable emission limits: (1) For transmitters operating in the 5.15-5.25 GHz band: all emissions outside of the 5.15-5.35 GHz band shall not exceed an EIRP of -27 dBm/MHz. (2) For transmitters operating in the 5.25-5.35 GHz band: all emissions outside of the 5.15-5.35 GHz band shall not exceed an EIRP of -27 dBm/MHz. Devices operating in the 5.25-5.35 GHz band that generate emissions in the 5.15-5.25 GHz band must meet all applicable technical requirements for operation in the 5.15-5.25 GHz band (including indoor use) or alternatively meet an out-of-band emission EIRP limit of -27 dBm/MHz in the 5.15-5.25 GHz band. (3) For transmitters operating in the 5.47-5.725 GHz band: all emissions outside of the 5.47-5.725 GHz band shall not exceed an EIRP of āˆ’27 dBm/MHz. (4) For transmitters operating in the 5.725-5.85 GHz band: All emissions shall be limited to a level of -27 dBm/MHz at 75 MHz or more above or below the band edge increasing linearly to 10 dBm/MHz at 25 MHz above or below the band edge, and from 25 MHz above or below the band edge increasing linearly to a level of 15.6 dBm/MHz at 5 MHz above or below the band edge, and from 5 MHz above or below the band edge increasing linearly to a level of 27 dBm/MHz at the band edge. Test Procedure: a. The EUT was placed on the top of a rotating table 1.5 m above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotable table was turned from 0 degrees to 360 degrees to find the maximum reading. e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values Page 253 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi- peak or average method as specified and then reported in a data sheet. Test setup: Above 1GHz Test Instruments: Refer to section 3.0 for details Test mode: Refer to section 2.2 for details Test results: Pass Remark: According to KDB 789033 D02 v02r01 section G) 1) (d), for For measurements above 1000 MHz @ 3m distance, the limit of field strength is computed as follows: E[dBuV/m] = EIRP[dBm] + 95.2, For example, if EIRP = -27dBm E[dBuV/m] = -27 + 95.2 = 68.2dBuV/m. Except for mode a, other modes test the MIMO status. The test result of SISO mode reflects the worst data between antenna 1 and antenna 2. Page 254 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Measurement Data: Band1 Mode: 802.11a Frequency: 5180MHz Antenna Pol. Frequency (MHz) Reading Level (dBuV) Factor (dB/m) Measure Level (dBuV/m) Limit (dBuV/m) Over limit(dB) Detector H 5150.00 54.30 -13.16 41.14 68.20 -27.06 PK V 5150.00 55.37 -13.16 42.21 68.20 -25.99 PK Mode: 802.11a Frequency: 5180MHz Antenna Pol. Frequency (MHz) Reading Level (dBuV) Factor (d…

Text truncated - open the document above for the full version.

Test Report

Page 194 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Power_Spectral_Density_NVNT_ANT2_802_11n(HT40)_5310 Power_Spectral_Density_NVNT_ANT1_802_11ac(VHT40)_5270 Page 195 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Power_Spectral_Density_NVNT_ANT2_802_11ac(VHT40)_5270 Power_Spectral_Density_NVNT_ANT1_802_11ac(VHT40)_5310 Page 196 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Power_Spectral_Density_NVNT_ANT2_802_11ac(VHT40)_5310 Power_Spectral_Density_NVNT_ANT1_802_11ac(VHT80)_5290 Page 197 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Power_Spectral_Density_NVNT_ANT2_802_11ac(VHT80)_5290 Page 198 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Condition Antenna Mode Frequency (MHz) MIMO PSD(dBm/MHz) Limit(dBm/MHz) Result NVNT MIMO_TX 802.11n(HT20) 5260.00 1.40 11 Pass NVNT MIMO_TX 802.11n(HT20) 5300.00 2.34 11 Pass NVNT MIMO_TX 802.11n(HT20) 5320.00 1.01 11 Pass NVNT MIMO_TX 802.11ac(VHT20) 5260.00 1.39 11 Pass NVNT MIMO_TX 802.11ac(VHT20) 5300.00 1.67 11 Pass NVNT MIMO_TX 802.11ac(VHT20) 5320.00 0.65 11 Pass NVNT MIMO_TX 802.11n(HT40) 5270.00 -3.65 11 Pass NVNT MIMO_TX 802.11n(HT40) 5310.00 -3.48 11 Pass NVNT MIMO_TX 802.11ac(VHT40) 5270.00 -5.64 11 Pass NVNT MIMO_TX 802.11ac(VHT40) 5310.00 -6.74 11 Pass NVNT MIMO_TX 802.11ac(VHT80) 5290.00 -14.35 11 Pass NVNT_MIMO_TX_802_11n(HT20)_Power_Spectral_Density_5260 NVNT_MIMO_TX_802_11n(HT20)_Power_Spectral_Density_5300 Page 199 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11n(HT20)_Power_Spectral_Density_5320 NVNT_MIMO_TX_802_11ac(VHT20)_Power_Spectral_Density_5260 Page 200 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11ac(VHT20)_Power_Spectral_Density_5300 NVNT_MIMO_TX_802_11ac(VHT20)_Power_Spectral_Density_5320 Page 201 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11n(HT40)_Power_Spectral_Density_5270 NVNT_MIMO_TX_802_11n(HT40)_Power_Spectral_Density_5310 Page 202 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11ac(VHT40)_Power_Spectral_Density_5270 NVNT_MIMO_TX_802_11ac(VHT40)_Power_Spectral_Density_5310 Page 203 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China NVNT_MIMO_TX_802_11ac(VHT80)_Power_Spectral_Density_5290 Page 204 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Band 3 (5500-5570 MHz) SISO: Condition Antenna Modulation Frequency (MHz) PSD(dBm/MHz) Duty factor(dB) Total PSD(dBm/MHz) limit(dBm) Result NVNT ANT1 802.11a 5500.00 -0.05 0.18 0.13 11 Pass NVNT ANT2 802.11a 5500.00 -0.53 0.18 -0.35 11 Pass NVNT ANT1 802.11a 5600.00 0.65 0.18 0.83 11 Pass NVNT ANT2 802.11a 5600.00 -0.64 0.18 -0.46 11 Pass NVNT ANT1 802.11a 5700.00 0.36 0.18 0.54 11 Pass NVNT ANT2 802.11a 5700.00 0.48 0.18 0.66 11 Pass NVNT ANT1 802.11n(HT20) 5500.00 -1.39 0.37 -1.02 11 Pass NVNT ANT2 802.11n(HT20) 5500.00 -2.40 0.38 -2.02 11 Pass NVNT ANT1 802.11n(HT20) 5600.00 -0.84 0.37 -0.47 11 Pass NVNT ANT2 802.11n(HT20) 5600.00 -1.96 0.38 -1.58 11 Pass NVNT ANT1 802.11n(HT20) 5700.00 -3.40 0.25 -3.15 11 Pass NVNT ANT2 802.11n(HT20) 5700.00 -2.10 0.37 -1.73 11 Pass NVNT ANT1 802.11ac(VHT20) 5500.00 -2.01 0.51 -1.50 11 Pass NVNT ANT2 802.11ac(VHT20) 5500.00 -4.36 0.51 -3.85 11 Pass NVNT ANT1 802.11ac(VHT20) 5600.00 -2.11 0.51 -1.60 11 Pass NVNT ANT2 802.11ac(VHT20) 5600.00 -4.46 0.51 -3.95 11 Pass NVNT ANT1 802.11ac(VHT20) 5700.00 -4.38 0.35 -4.03 11 Pass NVNT ANT2 802.11ac(VHT20) 5700.00 -5.59 0.51 -5.08 11 Pass NVNT ANT1 802.11n(HT40) 5510.00 -5.75 0.46 -5.29 11 Pass …

Text truncated - open the document above for the full version.

Test Report

Page 135 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT1_802_11ac(VHT20)_5745 99%_OCB_NVNT_ANT2_802_11ac(VHT20)_5745 Page 136 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT2_802_11ac(VHT20)_5745 99%_OCB_NVNT_ANT1_802_11ac(VHT20)_5785 Page 137 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT1_802_11ac(VHT20)_5785 99%_OCB_NVNT_ANT2_802_11ac(VHT20)_5785 Page 138 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT2_802_11ac(VHT20)_5785 99%_OCB_NVNT_ANT1_802_11ac(VHT20)_5825 Page 139 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT1_802_11ac(VHT20)_5825 99%_OCB_NVNT_ANT2_802_11ac(VHT20)_5825 Page 140 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT2_802_11ac(VHT20)_5825 99%_OCB_NVNT_ANT1_802_11n(HT40)_5755 Page 141 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT1_802_11n(HT40)_5755 99%_OCB_NVNT_ANT2_802_11n(HT40)_5755 Page 142 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT2_802_11n(HT40)_5755 99%_OCB_NVNT_ANT1_802_11n(HT40)_5795 Page 143 of 295 Report No.: psi2602048-C01-R08 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China -26BW_NVNT_ANT1_802_11n(HT4…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Liyang Chen
[email protected]Fax: 13538214502

Technical Contact

Motic Instruments USA, Inc.Mrs Christina Tsoi
[email protected]

1500 Northlake Pass Suite 197 Ā· Universal City, 78148 Ā· United States

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz93.11 mW
215E5.26 GHz - 5.32 GHz73.79 mW
315E5.50 GHz - 5.70 GHz62.95 mW
415E5.75 GHz - 5.83 GHz71.45 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The device supports 20MHz, 40MHz and 80MHz bandwidths. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.