2BPSN-L2526Wireless Bridge

LYSORA TECHNOLOGY INC.

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jan 14, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless Bridge
Frequency Range
5180.00000000 - 5240.00000000
Company
LYSORA TECHNOLOGY INC.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

LYSORA TECHNOLOGY INC. Covered Equipment Certification Attestation Letter 2025-11-07 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID:2BPSN-L2526 LYSORA TECHNOLOGY INC. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. LYSORA TECHNOLOGY INC. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. LYSORA TECHNOLOGY INC. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Semon He Title: R & D Director Company Name: LYSORA TECHNOLOGY INC. Address: 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Phone: 213-281-0459 E-Mail: [email protected] Date: 2025-11-07 LYSORA TECHNOLOGY INC.

Attestation Statements

LYSORA TECHNOLOGY INC. U.S. Agent Designation for Service of Process - Certification Attestation Letter LYSORA TECHNOLOGY INC. 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 2025-11-07 Attestation Statement according to 2.911(d)(7) FCC ID: 2BPSN-L2526 TO WHOM IT MAY CONCERN: We, LYSORA TECHNOLOGY INC. designate ourselves to act as U.S. agent for service of process. LYSORA TECHNOLOGY INC. hereby acknowledges the obligation of the U.S. agent for service of process. Further LYSORA TECHNOLOGY INC. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Sincerely Applicant Signed/ Designated Agent Signed: Signature: Company name: LYSORA TECHNOLOGY INC. FRN: 0037080140 Address: 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Contact Person: Semon He Telephone No: 213-281-0459 Email: [email protected]

Cover Letter(s)

LYSORA TECHNOLOGY INC. 2025-11-07 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Damon Hu, Guangdong Dongdian Testing Service Co.,Ltd.( Unit 2, Building 1, No.17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808), to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Semon He Title: R & D Director Company Name: LYSORA TECHNOLOGY INC. Address: 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Phone: 213-281-0459 E-Mail: [email protected] Date: 2025-11-07 LYSORA TECHNOLOGY INC.

Cover Letter(s)

LYSORA TECHNOLOGY INC. 2025-11-07 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY – FCC FCC ID: 2BPSN-L2526 Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Semon He Title: R & D Director Company Name: LYSORA TECHNOLOGY INC. Address: 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Phone: 213-281-0459 LYSORA TECHNOLOGY INC. E-Mail: [email protected] Date: 2025-11-07

ID Label/Location Info

批准 (PDTL) 密级:C 示意图 技术要求 1. 材质为50番偏白哑银,覆哑膜, 尺寸35.7x14.6mm,背胶类型应耐高温,不起泡。 要求标签使用耐酒精和正己烷测试的碳带规格 2. 黑白印刷 3. 公差:+0.2mm,-0.2mm 4. N长度供货 5. 印刷不得有缺划,断划,毛刺等现象 6. 制品要经确认方可量产 标贴粘度需要满足耐高温最高100度/最低-40度的要求 7.背网格胶,背胶类型应耐高温,耐起泡。 要求使用耐酒精和正己烷测试的碳带规格胶水应保证贴上去不能起泡,老化后不能起翘,不能爬墙,且测试要求满足 《标签测试规范》LYSORA 针对外协厂如果测试不起泡可以继续使用平纹胶 。() 固定来料部分 红框处为在线打印内容 英文字体分别为Noto Sans Bold Noto Sans Medium 35.7 mm 14.6 mm 示意图 技术要求 1.字符工艺为。镭雕,镭雕的颜色应接近PANTONE Cool Gray 7C 2.丝印位置和尺寸依据墨稿。 3.印刷不得出现缺划、断划、毛刺等现象。 4.产品经确认后方可量产。

RF Exposure Info

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF No.: RT-4-E-006Page 1 of 7 RF EXPOSURE REPORT Applicant : LYSORA TECHNOLOGY INC. Address of Applicant : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Manufacturer : LYSORA TECHNOLOGY INC. Address of Manufacturer : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Equipment under Test : Wireless Bridge Model No. : L2526 FCC ID : 2BPSN-L2526 Test Standard(s) : KDB447498 D01 General RF Exposure Guidance v06 Report No. : DDT-RE25092317-2E05 Issue Date : 2026/01/08 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF No.: RT-4-E-006Page 2 of 7 Table of Contents 1.General Test Information..............................................................................................5 1.1.Description of EUT .......................................................................................................5 1.2.Accessories of EUT......................................................................................................5 1.3.Test laboratory .............................................................................................................5 2.RF Exposure evaluation for FCC .................................................................................6 2.1.Assessment procedure.................................................................................................6 2.2.Assess result ................................................................................................................7 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF:RT-4-E-006Page 3 of 7 $!CeMetaLims!digital$ Test Report Declare Applicant : LYSORA TECHNOLOGY INC. Address of Applicant : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Equipment under Test : Wireless Bridge Model No. : L2526 Manufacturer : LYSORA TECHNOLOGY INC. Address of Manufacturer : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Test Standard Used: KDB447498 D01 General RF Exposure Guidance v06 We Declare: The equipment described above is tested by Guangdong Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Guangdong Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Report No.:DDT-RE25092317-2E05 Date of Receipt:2025/10/16Date of Test:2025/10/16~2026/01/05 Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Guangdong Dongdian Testing Service Co., Ltd. Created: Tiger MoReviewed: Johnson HuangApproved: Ella Gong 2026/01/052026/01/082026/01/08 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF:RT-4-E-006Page 4 of 7 Revision History VersionRevision ContentIssue DateApproved V0Initial issue2026/01/08Ella Gong Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF:RT-4-E-006Page 5 of 7 1. General Test Information 1.1. Description of EUT EUT Name:Wireless Bridge Model Number:L2526 Difference of model number : / EUT Function Description:Please reference user manual of this device Power Supply:PoE Input 24V, 0.5A Note: The above EUT information is declared by manufacturer and for more detailed features description please refer to the manufacturer's specifications or User's Manual. 1.2. Accessories of EUT AccessoriesManufacturerModel numberDescription POE Switching Power Supply RISUNIC Technology (ShenZhen) Co., Ltd. RP023- 2400500ZG Input: AC 100-240V, 50/60Hz 0.5A Max. output: DC 24.0V/0.5A 12.0W +(4,5) pins, -(7,8) pins Power cable/// 1.3. Test laboratory Guangdong Dongdian Testing Service Co., Ltd. Add.: Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, R-20240, G-20118 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF:RT-4-E-006Page 6 of 7 2. RF Exposure evaluation for FCC 2.1. Assessment procedure Requirement: Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic FieldStrength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.346141.63(100)*30 1.34-30824/f2.19/f(180/f)*30 30-30027.50.0730.230 300-1500 F/150030 1500-100000 1.030 Note: f= frequency in MHz; *Plane-wave equivalent power density Calculation method From the peak EUT RF output power, the minimum mobile separation distance, d=0.2 m, as well as the gain of the used antenna, the RF power density can be obtained. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E05 TRF:RT-4-E-006Page 7 of 7 2.2. Assess result Mode Output power (dBm) Output power (mW) Tune up power (dBm) Tune up power (mW) Antenna Gain (dBi) Antenna Gain (linear) MPE Values (mW/cm 2 ) MPE Limit (…

Text truncated - open the document above for the full version.

Test Report

Model Number Antenna Model Number Operation frequency FreqMaxEffiFreqMaxEffiFreqEffiMax (MHz)(dB)(%)(MHz)(dB)(%)(MHz)(%)(dB) 5150.0018.2346.175150.0018.4246.99 5170.0018.3746.295170.0018.3746.67 5190.0018.4947.415190.0018.2646.75 5210.0018.6746.545210.0018.2245.52 5230.0018.6947.015230.0018.0845.74 5250.0018.847.395250.0018.0746.2 5270.0018.8146.255270.0018.0144.74 5290.0018.845.745290.0017.9844.72 5310.0018.8245.755310.0017.9144.57 5330.0018.8545.665330.0017.944.43 5350.0018.8144.985350.0017.8143.42 5370.0018.8345.215370.0017.7943.37 5390.0018.8444.825390.0017.7742.75 5410.0018.945.35410.0017.8443.31 5430.0018.9445.775430.0017.9144.16 5450.0019.0446.545450.0018.0545.34 5470.0019.1746.845470.0018.2146.27 5490.0019.2247.295490.0018.3447.4 5510.0019.1746.735510.0018.3647.3 5530.0019.246.515530.0018.4347.52 5550.0019.1845.645550.0018.4146.66 5570.0019.2345.855570.0018.4647.07 5590.0019.2644.895590.0018.4646.05 5610.0019.1844.395610.0018.4145.48 5630.0019.244.455630.0018.4145.5 5650.0019.244.035650.0018.3945.1 5670.0019.243.255670.0018.3744.23 5690.0019.2242.565690.0018.3743.55 5710.0019.2242.225710.0018.3743.39 5730.0019.1540.965730.0018.3142.67 5750.0019.1340.145750.0018.442.54 5770.0019.1239.45770.0018.4142.63 5790.0019.1238.385790.0018.4942.25 5810.0019.0937.625810.0018.5142.54 5830.0019.0937.225830.0018.5743.13 5850.0019.1437.175850.0018.6643.71 Address: R&F Center C1-1425, Taijiang District, Fuzhou City, Fujian Province Test Result 5G Antenna 15G Antenna 2 Test condition 22.2°C/ 43 % 5150-5850MHz Manufacturer:Fuzhou JieLei Electronic Technology Co.,Ltd. OTA Test Report Antenna typeDirectional AntennaC168-JL-82A/C168-JL-82B Fuzhou JieLei Electronic Technology Co.,Ltd. OTA Test Report General Information UETWireless BridgeRG-AirMetro460G √√√ √ √√√√√√√ Fuzhou JieLei Electronic Technology Co.,Ltd. OTA Test Report 5G Antenna 1 5G Antenna 2

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF: RT-4-E-005Page 1 of 370 RADIO TEST REPORT Applicant : LYSORA TECHNOLOGY INC. Address of Applicant : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Manufacturer : LYSORA TECHNOLOGY INC. Address of Manufacturer : 8 THE GREEN, STE A, DOVER, KENT COUNTY, DELAWARE 19901, USA Equipment under Test : Wireless Bridge Model No. : L2526 FCC ID : 2BPSN-L2526 IC : 34118-L2526 Test Standard(s) : 47 CFR Part 15 Subpart E, ANSI C63.10-2020, 789033 D02 General U-NII Test Procedures New Rules v02r01, 662911 D01 Multiple Transmitter Output v02r01 Report No. : DDT-RE25092317-2E02 Issue Date : 2026/01/08 Issue By : Guangdong Dongdian Testing Service Co., Ltd. Unit 2, Building 1, No. 17, Zongbu 2nd Road, Songshan Lake Park, Dongguan, Guangdong, China, 523808 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF: RT-4-E-005Page 2 of 370 Table of Contents 1.Summary of Test Results .............................................................................................7 2.General Test Information..............................................................................................8 2.1.Description of EUT .......................................................................................................8 2.2.Accessories of EUT......................................................................................................9 2.3.Block diagram of EUT configuration for test.................................................................9 2.4.Decision of final test mode ...........................................................................................9 2.5.Deviations of test standard.........................................................................................11 2.6.Test environment conditions ......................................................................................11 2.7.Test laboratory ...........................................................................................................12 2.8.Measurement uncertainty...........................................................................................12 3.Equipment Used During Conductive Test ..................................................................13 4.26dB Bandwidth .........................................................................................................14 4.1.Block diagram of test setup ........................................................................................14 4.2.Limits ..........................................................................................................................14 4.3.Test procedure ...........................................................................................................14 4.4.Test result...................................................................................................................15 4.5.Test graphs ................................................................................................................17 5.6dB Bandwidth ...........................................................................................................57 5.1.Block diagram of test setup ........................................................................................57 5.2.Limits ..........................................................................................................................57 5.3.Test procedure ...........................................................................................................57 5.4.Test result B4 .............................................................................................................58 5.5.Test graphs B4 ...........................................................................................................59 6.99% Bandwidth ..........................................................................................................69 6.1.Block diagram of test setup ........................................................................................69 6.2.Limits ..........................................................................................................................69 6.3.Test procedure ...........................................................................................................69 6.4.Test result...................................................................................................................70 6.5.Test graphs ................................................................................................................72 7.Duty Cycle ................................................................................................................112 7.1.Block diagram of test setup ......................................................................................112 7.2.Limit..........................................................................................................................112 7.3.Test procedure .........................................................................................................112 7.4.Test result.................................................................................................................113 7.5.Test graphs ..............................................................................................................116 8.Maximum Output Power...........................................................................................156 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF: RT-4-E-005Page 3 of 370 8.1.Block diagram of test setup ......................................................................................156 8.2.Limits ........................................................................................................................156 8.3.Test procedure ..............................................................................................…

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 315 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5310MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chamber File Path:d:\ts\2025 report date\Q25092317-2E\FCC Above 1G 5G\70 Memo:Sample Numble:S25092317-004;Power Setting:15.5 Suspected Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] AMP [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15350.00042.7332.505.14-29.7350.6468.2017.56PKHorizontal 25351.40048.1832.515.14-29.7356.1074.0017.90PKHorizontal Final Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15351.40038.6932.515.1446.6154.007.39AVHorizontal Note: 1. Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 316 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5310MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chamber File Path:d:\ts\2025 report date\Q25092317-2E\FCC Above 1G 5G\71 Memo:Sample Numble:S25092317-004;Power Setting:15.5 Suspected Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] AMP [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15350.00045.9132.505.14-29.7353.8268.2014.38PKVertical 25353.92050.9232.535.14-29.7358.8674.0015.14PKVertical Final Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15350.00039.4532.505.1447.3654.006.64AVVertical 25353.91838.3332.535.1446.2754.007.73AVVertical Note: 1. Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 317 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5510MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chamber File Path:d:\ts\2025 report date\Q25092317-2E\FCC Above 1G 5G\72 Memo:Sample Numble:S25092317-004;Power Setting:15.5 Suspected Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] AMP [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15435.74445.1232.835.18-29.7153.4274.0020.58PKHorizontal 25460.00042.5932.905.19-29.7150.9768.2017.23PKHorizontal Final Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15435.74438.7932.835.1847.0954.006.91AVHorizontal 25460.00038.5432.905.1946.9254.007.08AVHorizontal Note: 1. Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 318 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5510MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chamber File Path:d:\ts\2025 report date\Q25092317-2E\FCC Above 1G 5G\73 Memo:Sample Numble:S25092317-004;Power Setting:15.5 Suspected Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] AMP [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15446.66446.6232.815.18-29.7154.9074.0019.10PKVertical 25460.00043.7532.905.19-29.7152.1368.2016.07PKVertical Final Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15446.66438.5332.815.1846.8154.007.19AVVertical 25460.00038.9732.905.1947.3554.006.65AVVertical Note: 1. Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 319 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5670MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chamber File Path:d:\ts\2025 report date\Q25092317-2E\FCC Above 1G 5G\74 Memo:Sample Numble:S25092317-004;Power Setting:15.5 Suspected Data List NO . Freq. [MHz] Reading [dBμV/m] Antenna Factor [dB] Cable loss [dB] AMP [dB] Level [dBμV/m] Limit [dBμV/m] Margin [dB] DetectorPolarity 15725.00041.3733.455.32-29.6550.4968.2017.71PKHorizontal 25744.42344.2733.725.33-29.6553.6768.2014.53PKHorizontal Note: 1. Level = Reading + Cable loss + Antenna Factor + AMP 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 320 of 370 TR-4-E-009 Radiated Emission Test Result Test Date:2025-11-09Tested By:Li Xiongbin EUT:Wireless BridgeModel Number:L2526 Test Mode:MIMO TX 11N40 5670MHz ModePower Supply:PoE Input 24V, 0.5A Condition:Temp:23.8°C;Humi:54.6%Test Site:DDT 3# Chambe…

Text truncated - open the document above for the full version.

Test Report

Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 181 of 370 11N20MIMO_Ant2_5580 11N20MIMO_Ant1_5700 11N20MIMO_Ant2_5700 A Att30dB ** 3DB RBW1MHz SWT20ms * Offset22.1dB LVL Ref20dBm Center5.58GHzSpan40MHz4MHz/ * VBW3MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -11.69dBm 5.581200000GHz Date: 2.DEC.2025 00:16:19 A Att30dB ** 3DB RBW1MHz SWT20ms * Offset22.7dB LVL Ref20dBm Center5.58GHzSpan40MHz4MHz/ * VBW3MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -10.04dBm 5.581400000GHz Date: 2.DEC.2025 00:19:14 A Att30dB ** 3DB RBW1MHz SWT20ms * Offset22.7dB LVL Ref20dBm Center5.7GHzSpan40MHz4MHz/ * VBW3MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -8.75dBm 5.700960000GHz Date: 2.DEC.2025 00:26:14 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 182 of 370 11N20MIMO_Ant1_5745 11N20MIMO_Ant2_5745 11N20MIMO_Ant1_5785 A Att30dB ** 3DB RBW1MHz SWT20ms * Offset23.3dB LVL Ref20dBm Center5.7GHzSpan40MHz4MHz/ * VBW3MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -8.40dBm 5.701000000GHz Date: 2.DEC.2025 00:29:10 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset22.5dB LVL Ref20dBm Center5.745GHzSpan40MHz4MHz/ * VBW2MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -9.44dBm 5.746080000GHz Date: 2.DEC.2025 00:39:10 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset23.1dB LVL Ref20dBm Center5.745GHzSpan40MHz4MHz/ * VBW2MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -9.45dBm 5.743880000GHz Date: 2.DEC.2025 00:42:22 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 183 of 370 11N20MIMO_Ant2_5785 11N20MIMO_Ant1_5825 11N20MIMO_Ant2_5825 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset22.2dB LVL Ref20dBm Center5.785GHzSpan40MHz4MHz/ * VBW2MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -9.10dBm 5.785960000GHz Date: 2.DEC.2025 00:46:04 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset22.7dB LVL Ref20dBm Center5.785GHzSpan40MHz4MHz/ * VBW2MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -9.65dBm 5.786320000GHz Date: 2.DEC.2025 00:49:16 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset22.3dB LVL Ref20dBm Center5.825GHzSpan40MHz4MHz/ * VBW2MHz * *1RM VIEW -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 1 Marker1[T1] -7.51dBm 5.825600000GHz Date: 2.DEC.2025 00:52:58 Guangdong Dongdian Testing Service Co., Ltd. Report No.:DDT-RE25092317-2E02 TRF:RT-4-E-005Page 184 of 370 11N40MIMO_Ant1_5190 11N40MIMO_Ant2_5190 11N40MIMO_Ant1_5230 A Att30dB ** 3DB RBW500kHz SWT20ms * Offset22.9dB LVL Ref20dBm Cente…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Semon He(R & D Director)
[email protected]Fax: 213-281-0459

Technical Contact

LYSORA TECHNOLOGY INC.Semon He
[email protected]

8 THE GREEN, STE A, DOVER · KENT COUNTY, Delaware, 19901 · United States

Test Firm

Guangdong Dongdian Testing Service Co., Ltd.Mr. Jamy Yu
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz4.25 mW
215E5.26 GHz - 5.32 GHz3.42 mW
315E5.50 GHz - 5.70 GHz3.24 mW
415E5.75 GHz - 5.83 GHz8.61 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device has 20 MHz, 40 MHz, and 80 MHz bandwidth mode. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter, except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from LYSORA TECHNOLOGY INC.

2BPSN-L2533

Wireless Access Point

Jan 19, 2026

Equipment Class

DTS - Digital Transmission System
2BPSN-L2534

Wireless Access Point

Jan 12, 2026

Equipment Class

DTS - Digital Transmission System
2BPSN-L2529

Wireless Bridge

Jan 04, 2026

Equipment Class

DTS - Digital Transmission System
2BPSN-L2542

Wireless Access Point

Dec 02, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX
2BPSN-L2538

Wireless Access Point

Dec 01, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX