2BR82-TRI020NBIoT Module

Triciti Coverage LLC

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Nov 24, 2025
Application Purpose
Original Equipment
Equipment Note
NBIoT Module
Frequency Range
663.00000000 - 698.00000000
Company
Triciti Coverage LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

BOM list

Cover Letter(s)

Modular Approval Request FCC (Per 15.212) FCC ID: 2BR82-TRI020 Items to be covered Answer From Applicant 1. The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements. Yes 2. The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with part 15 requirements under conditions of excessive data rates or over-modulation. Yes 3. The modular transmitter must have its own power supply regulation. Yes 4. The modular transmitter must comply with the antenna and transmission system requirements of §§ 15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The “professional installation” provision of § 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. Yes 5. The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing for compliance with part 15 requirements. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in § 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see § 15.27(a)). The length of these lines shall be the length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified and commercially available (see § 15.31(i)). Yes 6. The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. (A) If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment Yes authorization. (B) If the modular transmitter uses an electronic display of the FCC identification number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC certified transmitter module(s).” Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be included in the application for equipment authorization. 7. The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Yes 8. Radio frequency devices operating under the provisions of this part are subject to the radio frequency radiation exposure requirements specified in §§ 1.1307(b), 1.1310, 2.1091, and 2.1093 of this chapter, as appropriate. Applications for equipment authorization of modular transmitters under this section must contain a statement confirming compliance with these requirements. The modular transmitter must comply with any applicable RF exposure requirements in its final configuration. Technical information showing the basis for this statement must be submitted to the Commission upon request. Yes Note: If compliance with one or more of the numbered requirements, listed above, cannot be demonstrated, it may be possible to obtain a “Limited Modular Approval” (LMA) Name: Mike McMullen Title: CEO Company Name: Triciti Coverage LLC Date: 9/17/2025

ID Label/Location Info

18.3×22mm TRI-020 The label is located on the metal shielding cover of the module, The use of laser engraving technology makes it difficult for users to easily modify.

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For NB-IoT Module MODEL NUMBER: TRI-020 REPORT NUMBER: 4791928843-RF-2 ISSUE DATE Sep. 21, 2025: FCC ID: 2BR82-TRI020 Prepared for Triciti Coverage LLC 1350 Broadway, Ste 1400, New York, NY 10018 Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4791928843-RF-2 Page 2 of 7 Page 2 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 Sep. 21, 2025 Initial Issue \ REPORT NO.: 4791928843-RF-2 Page 3 of 7 Page 3 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ......................................................................................................... 4 2. TEST METHODOLOGY ............................................................................................................................. 5 3. FACILITIES AND ACCREDITATION ......................................................................................................... 5 4. REQUIREMENT ......................................................................................................................................... 6 REPORT NO.: 4791928843-RF-2 Page 4 of 7 Page 4 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Triciti Coverage LLC Address: 1350 Broadway, Ste 1400, New York, NY 10018 Manufacturer Information Company Name: Triciti Coverage LLC Address: 1350 Broadway, Ste 1400, New York, NY 10018 EUT Information EUT Name: NB-IoT Module Model: TRI-020 Series Model: \ Model Difference: \ Brand: Triciti Sample Received Date: Sep. 1, 2025 Sample Status: Normal Sample ID: 8851796 APPLICABLE STANDARDS STANDARD TEST RESULTS 47 CFR § 2.1091 PASS KDB 447498 D01 PASS Prepared By: Checked By: James Qin Kebo Zhang Project Engineer Operations Leader Approved By: Stephen Guo Operations Manager REPORT NO.: 4791928843-RF-2 Page 5 of 7 Page 5 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR Part 2 Subpart J, section 2.1091 and KDB447498 D01 v06. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Delcaration of Conformity (DoC) and Certification rules ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. REPORT NO.: 4791928843-RF-2 Page 6 of 7 Page 6 of 7 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIMIT AND CALCULATION METHOD Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. Limits for General Population/Uncontrolled Exposure RF EXPOSURE LIMIT Frequency Range (MHz) E-field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Time |E| 2 , |H| 2 or S (Minutes) 0.3 -- 1.34 614 1.63 (100)* 30 1.34 -- 30 824/f 2.19/f (180/f 2 )* 30 30 -- 300 27.5 0.073 0.2 30 300 -- 1500 -- -- f/1500 30 1500 -- 100,000 -- -- 1.0 30 CALCULATION METHOD…

Text truncated - open the document above for the full version.

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 2 CFR 47 FCC PART 22 H CFR 47 FCC PART 24 E CFR 47 FCC PART 27 CFR 47 FCC PART 90S RSS-130, RSS-132, RSS-133, RSS-139 TEST REPORT For NB-IoT Module MODEL NUMBER: TRI-020 REPORT NUMBER: 4791928843-RF-1 ISSUE DATE: Sep. 21, 2025 FCC ID: 2BR82-TRI020 IC ID: 34598-TRI020 Prepared for Triciti Coverage LLC 1350 Broadway, Ste 1400, New York, NY 10018 Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4791928843-RF-1 Page 2 of 44 Page 2 of 44 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0114 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 Sep. 21, 2025 Initial Issue \ Note: 1.This test report is only published to and used by the applicant, and it is not for evidence purpose in China. 2. The measurement result for the sample received is <Pass> according to < CFR 47 FCC PART 22 H >< CFR 47 FCC PART 24 E>< CFR 47 FCC PART 27 >< CFR 47 FCC PART 90S > < RSS-130, RSS-132, RSS-133, RSS-139 >when < Simple Acceptance > decision rule is applied. REPORT NO.: 4791928843-RF-1 Page 3 of 44 Page 3 of 44 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0114 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ......................................................................................................... 5 2. TEST METHODOLOGY ............................................................................................................................. 6 3. FACILITIES AND ACCREDITATION ......................................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ........................................................................................................ 7 4.1. MEASURING INSTRUMENT CALIBRATION ...................................................................................... 7 4.2. MEASUREMENT UNCERTAINTY ...................................................................................................... 7 5. EQUIPMENT UNDER TEST ...................................................................................................................... 8 5.1. DESCRIPTION OF EUT ...................................................................................................................... 8 5.2. TEST CONFIGURATION .................................................................................................................... 8 5.3. MAXIMUM AVERAGE OUTPUT POWER ........................................................................................... 9 5.3.1. NB-IOT Band 2 ............................................................................................................................. 9 5.3.1. NB-IOT Band 4 ............................................................................................................................. 9 5.3.1. NB-IOT Band 5 ............................................................................................................................. 9 5.3.1. NB-IOT Band 12 ......................................................................................................................... 10 5.3.1. NB-IOT Band 13 ......................................................................................................................... 10 5.3.1. NB-IOT Band 26 ......................................................................................................................... 10 5.3.1. NB-IOT Band 66 ......................................................................................................................... 11 5.3.1. NB-IOT Band 71 ......................................................................................................................... 11 5.4. WORST-CASE CONFIGURATION AND MODE ............................................................................... 12 5.5. DESCRIPTION OF AVAILABLE ANTENNAS .................................................................................... 13 5.6. DESCRIPTION OF TEST SETUP ..................................................................................................... 14 6. MEASURING INSTRUMENT AND SOFTWARE USED ........................................................................... 15 7. ANTENNA TERMINAL TEST RESULTS ................................................................................................. 16 7.1. EFFECTIVE (ISOTROPIC) RADIATED POWER OF TRANSMITTER ............................................... 16 7.2. PEAK TO AVERAGE RADIO ............................................................................................................ 18 7.3. OCCUPIED BANDWIDTH ................................................................................................................. 19 7.4. BAND EDGE EMISSIONS................................................................................................................. 20 7.5. SPURIOUS EMISSION AT ANTENNA TERMINAL ........................................................................... 22 7.6. FREQUENCY STABILITY ..................................................…

Text truncated - open the document above for the full version.

Test Report

Appendix A: Effective (Isotropic) Radiated Power Output Data for NB1 Test Result Band OpMode SCS BW Modulation Channel Tones Conducted POWER(dBm) ERP/EIRP(dBm) Verdict Band2 Stand-Alone 3.75kHz 0.18 QPSK 18602 1@0 25.59 25.59 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 18602 1@47 25.50 25.5 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 1@0 23.71 23.71 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 1@11 23.71 23.71 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 3@3 25.08 25.08 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18602 1@0 25.59 25.59 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18602 1@47 25.57 25.57 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18602 1@0 23.68 23.68 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18602 1@11 23.70 23.7 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 18900 1@0 26.15 26.15 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 18900 1@47 26.14 26.14 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18900 1@0 24.48 24.48 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18900 1@11 24.48 24.48 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18900 3@3 25.48 25.48 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18900 1@0 26.12 26.12 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18900 1@47 26.13 26.13 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18900 1@0 24.43 24.43 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18900 1@11 24.45 24.45 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 19198 1@0 25.85 25.85 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 19198 1@47 25.85 25.85 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 1@0 23.87 23.87 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 1@11 23.83 23.83 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 3@3 25.13 25.13 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 19198 1@0 25.83 25.83 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 19198 1@47 25.83 25.83 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 19198 1@0 23.84 23.84 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 19198 1@11 23.84 23.84 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 19952 1@0 25.39 25.39 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 19952 1@47 25.37 25.37 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 1@0 23.77 23.77 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 1@11 23.80 23.8 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 3@3 25.12 25.12 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 19952 1@0 25.37 25.37 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 19952 1@47 25.37 25.37 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 19952 1@0 23.79 23.79 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 19952 1@11 23.83 23.83 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20175 1@0 25.68 25.68 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20175 1@47 25.67 25.67 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20175 1@0 23.11 23.11 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20175 1@11 23.10 23.1 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20175 3@3 25.38 25.38 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20175 1@0 25.65 25.65 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20175 1@47 25.67 25.67 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20175 1@0 23.10 23.1 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20175 1@11 23.13 23.13 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20398 1@0 25.68 25.68 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20398 1@47 25.68 25.68 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 1@0 23.93 23.93 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 1@11 22.88 22.88 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 3@3 25.31 25.31 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20398 1@0 25.65 25.65 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20398 1@47 25.65 25.65 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20398 1@0 23.88 23.88 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20398 1@11 23.94 23.94 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20402 1@0 23.98 23.98 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20402 1@47 23.97 23.97 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 1@0 23.82 23.82 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 1@11 23.83 23.83 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 3@3 23.59 23.59 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20402 1@0 24.01 24.01 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20402 1@47 24.00 24 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20402 1@0 23.80 23.8 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20402 1@11 23.76 23.76 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20525 1@0 23.67 23.67 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20525 1@47 23.66 23.66 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20525 1@0 23.57 23.57 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20525 1@11 23.71 23.71 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20525 3@3 23.09 23.09 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20525 1@0 23.69 23.69 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20525 1@47 23.73 23.73 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20525 1@0 23.55 23.55 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20525 1@11 23.53 23.53 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20648 1@0 23.65 23.65 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20648 1@47 23.67 23.67 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20648 1@0 23.56 23.56 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20648 1@11 23.56 23.56 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20648 3@3 22.88 22.88 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20648 1@0 23.70 23.7 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK 20648 1@47 23.70 23.7 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20648 1@0 23.52 23.52 PASS Band5 Stand-Alone 15kHz 0.18 BPSK 20648 1@11 23.54 23.54 PASS Band12 Stand-Alone 3.75kHz 0.18 QPSK 23012 1@0 23.66 23.66 PASS Band12 Stand-Alone 3.75kHz 0.18 QPSK 23012 1@47 23.67 23.67 PASS Band12 Stand-Alone 15kHz 0.18 QPSK 23012 1@0 23.77 23.77 PASS Band12 Stand-Alone 15kHz 0.18 QPSK 23012 1@11 23.78 23.78 PASS Band12 Stand-Alone 15kHz 0.18 QPSK 23012 3@3 23.26 23.26 PASS Band12 Stand-Alone 3.75kHz 0.18 BPSK 23012 1@0 23.68 23.68 PASS Band12 Stand-Alone 3.75kHz 0.18 BPSK 23012 1@47 23.64 23.64 PASS Band12 Stand-Alone 15kHz 0.18 BPSK 23012 1@0 23.76 23.76 PASS Band12 Stand-Alone 15kHz 0.18 BPSK 23012 1@11 23.75 23.75 PASS Band12 Stand-Alone 3.75kHz 0.18 QPSK 23095 1@0 23.77 23.77 PASS Band12 Stand-Alone 3.75kHz 0.18 QPSK 23095 1@47 23.77 23.77 PASS Band12 Stand-Alone 15kHz 0.18 QPSK 23095 1@0 23.89 23.89 PASS Band12 Stand-Alone 15kHz 0.18 QPS…

Text truncated - open the document above for the full version.

Test Report

[email protected] Band12-0.18-QPSK-23178-1@0-15kHz-PASS [email protected] Band12-0.18-BPSK-23178-1@0-15kHz-PASS Band12-0.18-BPSK-23012-12@0-15kHz-PASS Band12-0.18-BPSK-23095-12@0-15kHz-PASS Band12-0.18-BPSK-23178-12@0-15kHz-PASS [email protected] Band26-0.18-QPSK-26692-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-26692-1@0-15kHz-PASS [email protected] Band26-0.18-QPSK-26740-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-26740-1@0-15kHz-PASS [email protected] Band26-0.18-QPSK-26788-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-26788-1@0-15kHz-PASS Band26-0.18-BPSK-26692-12@0-15kHz-PASS Band26-0.18-BPSK-26740-12@0-15kHz-PASS Band26-0.18-BPSK-26788-12@0-15kHz-PASS [email protected] Band26-0.18-QPSK-26792-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-26792-1@0-15kHz-PASS [email protected] Band26-0.18-QPSK-26915-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-26915-1@0-15kHz-PASS [email protected] Band26-0.18-QPSK-27038-1@0-15kHz-PASS [email protected] Band26-0.18-BPSK-27038-1@0-15kHz-PASS Band26-0.18-BPSK-26792-12@0-15kHz-PASS Band26-0.18-BPSK-26915-12@0-15kHz-PASS Band26-0.18-BPSK-27038-12@0-15kHz-PASS [email protected] PASS Band66-0.18-QPSK-131974-1@0-15kHz-PASS [email protected] Band66-0.18-BPSK-131974-1@0-15kHz-PASS [email protected] PASS Band66-0.18-QPSK-132322-1@0-15kHz-PASS [email protected] Band66-0.18-BPSK-132322-1@0-15kHz-PASS [email protected] PASS Band66-0.18-QPSK-132670-1@0-15kHz-PASS [email protected] Band66-0.18-BPSK-132670-1@0-15kHz-PASS Band66-0.18-BPSK-131974-12@0-15kHz-PASS Band66-0.18-BPSK-132322-12@0-15kHz-PASS Band66-0.18-BPSK-132670-12@0-15kHz-PASS [email protected] PASS Band71-0.18-QPSK-133124-1@0-15kHz-PASS [email protected] Band71-0.18-BPSK-133124-1@0-15kHz-PASS [email protected] PASS Band71-0.18-QPSK-133297-1@0-15kHz-PASS [email protected] Band71-0.18-BPSK-133297-1@0-15kHz-PASS [email protected] PASS Band71-0.18-QPSK-133470-1@0-15kHz-PASS [email protected] Band71-0.18-BPSK-133470-1@0-15kHz-PASS Band71-0.18-BPSK-133124-12@0-15kHz-PASS Band71-0.18-BPSK-133297-12@0-15kHz-PASS Band71-0.18-BPSK-133470-12@0-15kHz-PASS Band71-0.18-BPSK-133470-12@0-15kHz-PASS [email protected] Band13-0.18-QPSK-23181-1@0-15kHz-PASS Band13-0.18-QPSK-23181-12@0-15kHz-PASS [email protected] Band13-0.18-BPSK-23181-1@0-15kHz-PASS [email protected] Band13-0.18-QPSK-23230-1@0-15kHz-PASS Band13-0.18-QPSK-23230-12@0-15kHz-PASS [email protected] Band13-0.18-BPSK-23230-1@0-15kHz-PASS [email protected] Band13-0.18-QPSK-23279-1@0-15kHz-PASS Band13-0.18-QPSK-23279-12@0-15kHz-PASS [email protected] Band13-0.18-BPSK-23279-1@0-15kHz-PASS Appendix D: Band Edge for NB1 Test Result Band OpMode SCS BW Modulati on Channel Tones Result (dBm) Verdict Band2 Stand-Alone 3.75kHz 0.18 QPSK 18602 1@0 -38.34 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 18602 1@47 -52.47 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 1@0 -36.02 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 1@11 -48.97 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 18602 12@0 -37.80 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18602 1@0 -37.24 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 18602 1@47 -50.54 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18602 1@0 -31.49 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18602 1@11 -45.26 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 18602 12@0 -38.04 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 19198 1@0 -51.17 PASS Band2 Stand-Alone 3.75kHz 0.18 QPSK 19198 1@47 -37.91 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 1@0 -48.94 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 1@11 -36.17 PASS Band2 Stand-Alone 15kHz 0.18 QPSK 19198 12@0 -40.45 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 19198 1@0 -49.90 PASS Band2 Stand-Alone 3.75kHz 0.18 BPSK 19198 1@47 -36.30 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 19198 1@0 -46.93 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 19198 1@11 -30.85 PASS Band2 Stand-Alone 15kHz 0.18 BPSK 19198 12@0 -40.27 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 19952 1@0 -39.42 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 19952 1@47 -53.30 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 1@0 -37.05 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 1@11 -51.19 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 19952 12@0 -36.43 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 19952 1@0 -38.14 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 19952 1@47 -52.35 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 19952 1@0 -32.55 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 19952 1@11 -48.61 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 19952 12@0 -36.64 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20398 1@0 -44.00 PASS Band4 Stand-Alone 3.75kHz 0.18 QPSK 20398 1@47 -31.61 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 1@0 -49.04 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 1@11 -36.42 PASS Band4 Stand-Alone 15kHz 0.18 QPSK 20398 12@0 -35.25 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20398 1@0 -43.09 PASS Band4 Stand-Alone 3.75kHz 0.18 BPSK 20398 1@47 -31.35 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20398 1@0 -46.66 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20398 1@11 -31.42 PASS Band4 Stand-Alone 15kHz 0.18 BPSK 20398 12@0 -35.60 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20402 1@0 -41.08 PASS Band5 Stand-Alone 3.75kHz 0.18 QPSK 20402 1@47 -54.85 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 1@0 -38.49 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 1@11 -51.63 PASS Band5 Stand-Alone 15kHz 0.18 QPSK 20402 12@0 -40.04 PASS Band5 Stand-Alone 3.75kHz 0.18 BPSK…

Text truncated - open the document above for the full version.

Test Report

Band5-0.18-QPSK-20648-1@0-15kHz-PASS Band5-0.18-QPSK-20648-1@11-15kHz-PASS Band5-0.18-QPSK-20648-12@0-15kHz-PASS [email protected] [email protected] Band5-0.18-BPSK-20648-1@0-15kHz-PASS Band5-0.18-BPSK-20648-1@11-15kHz-PASS Band5-0.18-BPSK-20648-12@0-15kHz-PASS [email protected] [email protected] PASS Band12-0.18-QPSK-23012-1@0-15kHz-PASS Band12-0.18-QPSK-23012-1@11-15kHz-PASS Band12-0.18-QPSK-23012-12@0-15kHz-PASS [email protected] [email protected] Band12-0.18-BPSK-23012-1@0-15kHz-PASS Band12-0.18-BPSK-23012-1@11-15kHz-PASS Band12-0.18-BPSK-23012-12@0-15kHz-PASS [email protected] [email protected] PASS Band12-0.18-QPSK-23178-1@0-15kHz-PASS Band12-0.18-QPSK-23178-1@11-15kHz-PASS Band12-0.18-QPSK-23178-12@0-15kHz-PASS Band12-0.18-BPSK-23178-1@0-…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Mike McMullen(CEO)
[email protected]Fax: 949-697-3470

Test Firm

UL Verification Services (Guangzhou) Co., Ltd.Stephen Guo
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz412.00 mW185KG7D2.5ppm
224E1.85 GHz - 1.91 GHz409.00 mW115KF1D2.5ppm
3271.71 GHz - 1.75 GHz370.00 mW189KG7D2.5ppm
4271.71 GHz - 1.75 GHz369.00 mW113KF1D2.5ppm
522H824 MHz - 849 MHz250.00 mW184KG7D2.5ppm
622H824 MHz - 849 MHz252.00 mW110KF1D2.5ppm
727699 MHz - 716 MHz252.00 mW184KG7D2.5ppm
827699 MHz - 716 MHz249.00 mW108KF1D2.5ppm
927777 MHz - 787 MHz247.00 mW183KG7D2.5ppm
127777 MHz - 787 MHz244.00 mW105KF1D2.5ppm
119814 MHz - 824 MHz262.00 mW110KG7D2.5ppm
129814 MHz - 824 MHz259.00 mW110KF1D2.5ppm
1322H824 MHz - 849 MHz253.00 mW186KG7D2.5ppm
1422H824 MHz - 849 MHz251.00 mW110KF1D2.5ppm
15271.71 GHz - 1.78 GHz372.00 mW189KG7D2.5ppm
16271.71 GHz - 1.78 GHz371.00 mW113KF1D2.5ppm
1727663 MHz - 698 MHz234.00 mW184KG7D2.5ppm
1827663 MHz - 698 MHz234.00 mW108KF1D2.5ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular approval. Output power is conducted. Antenna gain including cable loss must not exceed 1.70 dBi in Cellular band, and 3.35 dBi in PCS band. This device supports the following LTE NB-LOT bands: Band 2, Band 4, Band 5, Band 12, Band 13, Band 26, Band 66, and Band 71 The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except in accordance with FCC multi-transmitter product procedures. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.