Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
INVERTER POOL PUMP INSTALLATION AND OPERATION MANUAL Follow this QR code for manual in other language Suivez ce QR code pour consulter le manuel en francais Volg deze QR-code om de handleiding in het Nederlands te raadplegen Scannen Sie diesen QR-Code, um die deutsche Version des Handbuchs THANK YOU FOR PURCHASING OUR INVERTER POOL PUMPS. THIS MANUAL CONTAINS IMPORTANT INFORMATION THAT WILL HELP YOU IN OPERATING AND MAINTAINING THIS PRODUCT. PLEASE READ THE MANUAL CAREFULLY BEFORE INSTALLATION & OPERATION AND RETAIN IT FOR FUTURE REFERENCE. CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS ....................................................................................... 1 2. TECHNICAL SPECIFICATIONS ............................................................................................................. 3 3. OVERALL DIMENSION (mm) ................................................................................................................ 3 4. INSTALLATION ........................................................................................................................................ 4 5. SETTING AND OPERATION.................................................................................................................. 6 6. EXTERNAL CONTROL ......................................................................................................................... 12 7. PROTECTION AND FAILURE .............................................................................................................. 14 8. MAINTENANCE ..................................................................................................................................... 17 9. WARRANTY & EXCLUSIONS .............................................................................................................. 17 10. DISPOSAL ............................................................................................................................................. 18 1 1. IMPORTANT SAFETY INSTRUCTIONS This guide provides installation and operation instructions for this pump. If you have any other questions about this equipment, please consult your supplier. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1.1 IEC This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 1.2 EN/UKCA This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and users’ maintenance shall not be made by children without supervision. 1.3 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 1.4 The pump must supplied through a residual current device (RCD) with a rated residual operating current ≤ 30 mA. 1.5 Electrical installation and include reference to national wiring rules. 1.6 Means for disconnection incorporated in fixed wiring in accordance with wiring rules. 1.7 Risk of electrical shock. Connect only to a branch circuit protected by a ground-fault circuit interrupter (GFCI). Contact a professionally trained and qualified electrician if you cannot verify that the circuit is protected by a GFCI. 1.8 To prevent the risk of electrical shock, please connect the ground wire on the motor (green/yellow) to the grounding system. 1.9 This pump is for use with permanently installed in-ground or above-ground swimming pools and may also 2 be used with hot tubs and spas with a water temperature under 50°C. Due to the fixed installation method, this pump is not suggested to be used on above-ground pools that can be readily disassembled for storage. 1.10 The pump is not submersible. 1.11 Never open the inside of the drive motor enclosure. WARNING: • Fill the pump with water before starting. Do not run the pump dry. In case of dry run, mechanical seal will be damaged and the pump will start leaking. • Before servicing the pump, switch power OFF to the pump by disconnecting the main circuit to the pump and release all pressure from pump and piping system. • Never tighten or loosen screws while the pump is operating. • Ensure that the inlet and outlet of the pump are unblocked with foreign matter. 3 2. TECHNICAL SPECIFICATIONS 3. OVERALL DIMENSION (mm) Model Advised Pool Volume (m³) P1 Voltage (V/Hz) Qmax (m³/h) Hmax (m) Circulation (m³/h) KW At 10m At 8m 20-30 0.75 115-230V / 50/60Hz 22.0 16.0 14.0 18.0 20-40 1.00 25.5 18.0 18.0 22.0 30-50 1.35 28.5 20.0 24.0 27.0 1.50 31.0 20.5 28.0 30.0 1.50 31.0 22.0 28.0 32.0 Figure 1 - Pump Dimensions Internal thread External thread(FBT2”) DE18 DV DE22 DV DE27 DV DE28 DV DE36 DV 1.50 31.0 25.0 36.0 40.0 1.50 31.0 29.0 28.0 42.0 DEX20 DEX25 30-50 30-50 20-40 20-40 4 4. INSTALLATION 4.1. Pump Location 1) Install the pump as close to the pool as possible, to reduce friction loss and improve efficiency, use short, direct suction and return piping. 2) To avoid direct sunshine, heat or rain, it is recommended to place the pump indoors or in the shade. 3) DO NOT install the pump in a damp or non-ventilated location. Keep pump and motor at least 150mm away from obstacles, pump motors require free circulation of air for cooling. 4) The pump should be installed horizontally and fixed in the hole on the support with screws to prevent unnecessary noise and vibration. 4.2. Plumbing and Valves 1) The pump inlet/outlet union size: o…
Text truncated - open the document above for the full version.
Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 10, 2025 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID or Grantee Code: 2BRMV-DE28DV-1 Applicant FRN: 0037382850 AQUAGEM TECHNOLOGY LIMITED(“the applicant”) certifies that, as of the date of the filing of the application, FCC US Agent, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. AQUAGEM TECHNOLOGY LIMITED accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. FCC US Agent, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: FCC US Agent, LLC U.S. Agent FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Tel.: 708-571-3148 Email: [email protected] Sincerely, AQUAGEM TECHNOLOGY LIMITED FCC US Agent, LLC Zhengrong Zou Tim Payne [Insert Applicant signature] [U.S. Agent signature]
Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 12-10-2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BRMV-DE28DV-1 AQUAGEM TECHNOLOGY LIMITED(“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. AQUAGEM TECHNOLOGY LIMITED(“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) Zhengrong Zou Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 12-10-2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID:2BRMV-DE28DV-1 AQUAGEM TECHNOLOGY LIMITED(“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) Zhengrong Zou
AQUAGEM TECHNOLOGY LIMITED Date:December 10, 2025 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:2BRMV-DE28DV-1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description Schematic.pdf Block Diagram.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou/Engineer Typed name and Title
AQUAGEM TECHNOLOGY LIMITED Difference Declaration Date: December 10, 2025 FCC ID: 2BRMV-DE28DV-1 We, AQUAGEM TECHNOLOGY LIMITED declare that the difference the submitted models as following: 1) All models have same electric circuit, PCB and RF module. 2) Difference series only different in the appearance. 3) Models in same series are identical except the rating parameters. 4) Customer models and factory models are identical except brand. Series Factory Model Customer Model Rating Inver Master IM20 / AC 115-230V, 50/60Hz, 800W IM25 / AC 115-230V, 50/60Hz, 950W-1100W IM30 / AC 115-230V, 50/60Hz, 1100W-1400W Inver Victor IT20 X08 AC 115-230V, 50/60Hz, 800W IT24 X10 AC 115-230V, 50/60Hz, 950W-1000W IT31 X15 AC 115-230V, 50/60Hz, 1100W-1500W Inver Pro IP20 / AC 115-230V, 50/60Hz, 800W IP25 / AC 115-230V, 50/60Hz, 1050W IP30 / AC 115-230V, 50/60Hz, 1400W IP40 / AC 115-230V, 50/60Hz, 1100W-1500W Inver Captain DC40 MP2AI AC 115-230V, 50/60Hz, 1100W-1500W DCP08DV MP10AIDV AC 115-230V, 50/60Hz, 800W DCP12DV MP15AIDV AC 115-230V, 50/60Hz, 950W-1200W DCP15DV MP165AIDV AC 115-230V, 50/60Hz, 1100W-1500W DCP18DV / AC 115-230V, 50/60Hz, 1100W-1500W DCX20 / AC 115-230V, 50/60Hz, 1100W-1500W DCX25 MP3AI AC 115-230V, 50/60Hz, 1100W-1500W Inver Gem IBP08DV / AC 115-230V, 50/60Hz, 800W IBP12DV / AC 115-230V, 50/60Hz, 950W-1200W IBP15DV A117 AC 115-230V, 50/60Hz, 1100W-1500W Inver Hero IHP08DV / AC 115-230V, 50/60Hz, 800W IHP12DV / AC 115-230V, 50/60Hz, 950W-1200W IHP15DV / AC 115-230V, 50/60Hz, 1100W-1500W IHP18DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver Smart DM14DV / AC 115-230V, 50/60Hz, 600W DM19DV MP10VSP, DQ19DV AC 115-230V, 50/60Hz, 800W AQUAGEM TECHNOLOGY LIMITED Series Factory Model Customer Model Rating DM23DV MP15VSP, DQ23DV AC 115-230V, 50/60Hz, 950W-1100W DM28DV MP165VSP, DQ28DV AC 115-230V, 50/60Hz, 1100W-1500W DM36DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver Eco DE18DV 21101 AC 115-230V, 50/60Hz, 750W DE22DV 21102 AC 115-230V, 50/60Hz, 900W-1000W DE27DV / AC 115-230V, 50/60Hz, 1000W-1350W DE28DV 21103 AC 115-230V, 50/60Hz, 1100W-1500W DE36DV / AC 115-230V, 50/60Hz, 1100W-1500W DEX20 / AC 115-230V, 50/60Hz, 1100W-1500W DEX25 / AC 115-230V, 50/60Hz, 1100W-1500W Inver S DS14DV / AC 115-230V, 50/60Hz, 600W DS19DV / AC 115-230V, 50/60Hz, 800W DS23DV / AC 115-230V, 50/60Hz, 950W-1100W DS28DV / AC 115-230V, 50/60Hz, 1100W-1500W DS36DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver PiLot DB14DV / AC 115-230V, 50/60Hz, 600W DB19DV P08DV, PP08DV AC 115-230V, 50/60Hz, 800W DB23DV P11DV, PP11DV AC 115-230V, 50/60Hz, 950W-1100W DB28DV P15DV, PP15DV AC 115-230V, 50/60Hz, 1100W-1500W DB36DV / AC 115-230V, 50/60Hz, 1100W-1500W Silence X DF14DV / AC 115-230V, 50/60Hz, 600W DF19DV T10 PRO AC 115-230V, 50/60Hz, 800W DF23DV T15 PRO AC 115-230V, 50/60Hz, 950W-1100W DF28DV T20 PRO AC 115-230V, 50/60Hz, 1100W-1500W DF36DV / AC 115-230V, 50/60Hz, 1100W-1500W Sincerely AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou / Engineer Typed name and Title
AQUAGEM TECHNOLOGY LIMITED FCC ID: 2BRMV-DE28DV-1 POWER OF ATTORNEY Date: December 10, 2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf shall have the same effect as acts of our own. This authorization expires on December 10, 2026 . This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, AQUAGEM TECHNOLOGY LIMITED are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou/Engineer Typed name and Title
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 1 of 3 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 2 of 3 Picture 3 Picture 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 3 of 3 Picture 5 Picture 6
Label Location
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 1 of 8 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 2 of 8 Picture 3 Picture 4 ANT Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 3 of 8 Picture 5 Picture 6 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 4 of 8 Picture 7 Picture 8
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 5 of 8 Picture 9 Picture 10 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 6 of 8 Picture 11 Picture 12 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 7 of 8 Picture 13 Picture 14 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF25F11314320W Page 8 of 8 Picture 15 Picture 16
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn RF Exposure Requirements 1 General Information Client Information Applicant ....................................... : AQUAGEM TECHNOLOGY LIMITED Address of applicant ................... : FLAT/RM H 19/F, MAXGRAND PLAZA, 3 TAI YAU STREET, SAN PO KONG KL. HONG KONG Manufacturer ................................. : Aquagem Manufacturing Limited Address of manufacturer ............. : NO.15, 101, 16, 401, 501, No.193, Jinlong Road, Dalong Street, Panyu District, Guangzhou General Description of E.U.T FCC ID ............................................ : 2BRMV-DE28DV-1 Product Name ............................... : Inverter Pool Pump Model No. ..................................... : See below model list Model Description ........................ : All models have same electric circuit and PCB layout except for the appearance, rated power and model name. Model List Series Factory Model Customer Model Rating Inver Master IM20 / AC 115-230V, 50/60Hz, 800W IM25 / AC 115-230V, 50/60Hz, 950W-1100W IM30 / AC 115-230V, 50/60Hz, 1100W-1400W Inver Victor IT20 X08 AC 115-230V, 50/60Hz, 800W IT24 X10 AC 115-230V, 50/60Hz, 950W-1000W IT31 X15 AC 115-230V, 50/60Hz, 1100W-1500W Inver Pro IP20 / AC 115-230V, 50/60Hz, 800W IP25 / AC 115-230V, 50/60Hz, 1050W IP30 / AC 115-230V, 50/60Hz, 1400W IP40 / AC 115-230V, 50/60Hz, 1100W-1500W Inver Captain DC40 MP2AI AC 115-230V, 50/60Hz, 1100W-1500W DCP08DV MP10AIDV AC 115-230V, 50/60Hz, 800W DCP12DV MP15AIDV AC 115-230V, 50/60Hz, 950W-1200W DCP15DV MP165AIDV AC 115-230V, 50/60Hz, 1100W-1500W DCP18DV / AC 115-230V, 50/60Hz, 1100W-1500W DCX20 / AC 115-230V, 50/60Hz, 1100W-1500W DCX25 MP3AI AC 115-230V, 50/60Hz, 1100W-1500W Inver Gem IBP08DV / AC 115-230V, 50/60Hz, 800W IBP12DV / AC 115-230V, 50/60Hz, 950W-1200W Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Series Factory Model Customer Model Rating IBP15DV A117 AC 115-230V, 50/60Hz, 1100W-1500W Inver Hero IHP08DV / AC 115-230V, 50/60Hz, 800W IHP12DV / AC 115-230V, 50/60Hz, 950W-1200W IHP15DV / AC 115-230V, 50/60Hz, 1100W-1500W IHP18DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver Smart DM14DV / AC 115-230V, 50/60Hz, 600W DM19DV MP10VSP, DQ19DV AC 115-230V, 50/60Hz, 800W DM23DV MP15VSP, DQ23DV AC 115-230V, 50/60Hz, 950W-1100W DM28DV MP165VSP, DQ28DV AC 115-230V, 50/60Hz, 1100W-1500W DM36DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver Eco DE18DV 21101 AC 115-230V, 50/60Hz, 750W DE22DV 21102 AC 115-230V, 50/60Hz, 900W-1000W DE27DV / AC 115-230V, 50/60Hz, 1000W-1350W DE28DV 21103 AC 115-230V, 50/60Hz, 1100W-1500W DE36DV / AC 115-230V, 50/60Hz, 1100W-1500W DEX20 / AC 115-230V, 50/60Hz, 1100W-1500W DEX25 / AC 115-230V, 50/60Hz, 1100W-1500W Inver S DS14DV / AC 115-230V, 50/60Hz, 600W DS19DV / AC 115-230V, 50/60Hz, 800W DS23DV / AC 115-230V, 50/60Hz, 950W-1100W DS28DV / AC 115-230V, 50/60Hz, 1100W-1500W DS36DV / AC 115-230V, 50/60Hz, 1100W-1500W Inver PiLot DB14DV / AC 115-230V, 50/60Hz, 600W DB19DV P08DV, PP08DV AC 115-230V, 50/60Hz, 800W DB23DV P11DV, PP11DV AC 115-230V, 50/60Hz, 950W-1100W DB28DV P15DV, PP15DV AC 115-230V, 50/60Hz, 1100W-1500W DB36DV / AC 115-230V, 50/60Hz, 1100W-1500W Silence X DF14DV / AC 115-230V, 50/60Hz, 600W DF19DV T10 PRO AC 115-230V, 50/60Hz, 800W DF23DV T15 PRO AC 115-230V, 50/60Hz, 950W-1100W DF28DV T20 PRO AC 115-230V, 50/60Hz, 1100W-1500W DF36DV / AC 115-230V, 50/60Hz, 1100W-1500W Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Technical Characteristics of EUT WiFi Support Standards ....................... : 802.11b, 802.11g, 802.11n Frequency Range ......................... : 2412-2462MHz for 802.11b/g/n(HT20) 2422-2452MHz for 802.11n(HT40) RF Output Power .......................... : 15.61dBm (Conducted ) Modulation .................................... : 802.11b: DSSS(DBPSK/DQPSK/CCK) 802.11g/n: OFDM (BPSK/QPSK/16QAM/64QAM) Quantity of Channels ................... : 11 for 802.11b/g/n(HT20); 8 for 802.11n(HT40) Channel Separation ...................... : 5MHz Type of Antenna ........................... : FPC Antenna Antenna Gain ................................ : -4.15dBi BLE Bluetooth Version ........................ : Bluetooth LE Frequency Range ......................... : 2402-2480MHz Max. RF Output Power ................. : 6.40dBm (Conducted ) Modulation .................................... : GFSK Data Rate ....................................... : 1Mbps Quantity of Channels ................... : 40 Channel Separation ...................... : 2MHz Type of Antenna ........................... : FPC Antenna Antenna Gain ................................ : -4.15dBi Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 2 Applicable Standard According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density 3 Calculation Method S = (30*P*G) / (377*R 2 ) S = power density (in appropriate units, e.g., mw/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mw) G = power gain of the antenna in the direction of interest r…
Text truncated - open the document above for the full version.
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 59 WT-510-201-12-A TEST REPORT Reference No. .................... : WTF25F11314319W001 FCC ID ................................ : 2BRMV-DE28DV-1 Applicant ............................ : AQUAGEM TECHNOLOGY LIMITED Address .............................. : FLAT / RM H 19/F MAXGRAND, PLAZA 3 TAI YAU STREET, SAN PO KONG KL, Hong Kong Manufacturer .................... : Aquagem Manufacturing Limited Address .............................. : NO.15, 101, 16, 401, 501, No.193, Jinlong Road, Dalong Street, Panyu District, Guangzhou Product Name .................... : Inverter Pool Pump Model No. ........................... : Refer to section 3.2 Test specification .............. : FCC CFR47 Part 15 Subpart C (Section 15.247) Date of Receipt sample .... : 2025-09-04 Date of Test ....................... : 2025-09-06 to 2025-09-09 Date of Issue ...................... : 2025-12-10 Test Report Form No. ....... : WEW-15247A-01B Test Result ......................... Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Foshan) Co., Ltd. Address: 1/F., Building 19, Sunlink Machinery City, Xingye 4 Road, Guanglong Industrial Park, Chihua Neighborhood Committee, Chencun, Shunde District, Foshan, Guangdong, China Tel:+86-757-23811398 Fax:+86-757-23811381 E-mail:[email protected] Tested by: Approved by: Jess Chen Danny Zhou Reference No.: WTF25F11314319W001 Page 2 of 59 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 1 Revision History Test Report No. Date of Issue Description Status WTF25F11314319W001 2025-12-10 Original Invalid Reference No.: WTF25F11314319W001 Page 3 of 59 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 2 Contents Page 1 REVISION HISTORY ................................................................................................................................. 2 2 CONTENTS ............................................................................................................................................... 3 3 GENERAL INFORMATION ....................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T ................................................................................................... 4 3.2 MODEL LIST .................................................................................................................................... 4 3.3 TECHNICAL CHARACTERISTICS OF EUT ........................................................................................... 6 3.4 STANDARDS APPLICABLE FOR TESTING ............................................................................................ 6 3.5 TEST FACILITY ................................................................................................................................ 7 3.6 SUBCONTRACTED ........................................................................................................................... 7 3.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 7 3.8 DISCLAIMER .................................................................................................................................... 7 3.9 OTHER ........................................................................................................................................... 7 4 EUT SETUP AND TEST MODE ................................................................................................................ 8 5 EQUIPMENT USED DURING TEST ......................................................................................................... 9 5.1 EQUIPMENT LIST ........................................................................................................................... 10 5.2 TEST SOFTWARE .......................................................................................................................... 10 5.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ....................................................................... 10 5.4 MEASUREMENT UNCERTAINTY ....................................................................................................... 10 6 SUMMARY OF TEST RESULT .............................................................................................................. 11 6.1 ANTENNA REQUIREMENT ............................................................................................................... 12 6.2 RADIATED SPURIOUS EMISSIONS ................................................................................................... 13 6.3 POWER SPECTRAL DENSITY .......................................................................................................... 23 6.4 DTS BANDWIDTH .......................................................................................................................... 28 6.5 RF OUTPUT POWER ...................................................................................................................... 33 6.6 OUT OF BAND EMISSIONS .............................................................................................................. 39 6.7 CONDUCTED EMISSIONS................................................................................................................ 53 7 PHOTOGRAPHS TEST SETUP ............................................................................................................. 57 7.1 PHOTOGRAPHS - RADIATED EMISSION TEST SETUP ........................................................................ 57 7.2 PHOTOGRAPHS – …
Text truncated - open the document above for the full version.
Sushi TOWE Wireless Testing (Shenzhen) Co., Ltd. Report No.: TCED25090078301 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. Antenna Passive Test Report Project No. : TCED250900783 Product Type : Control Panel for Surfing SwimJet Test Mode : Free Space Date of Receipt : 2025/09/08 Date of Test : 2025/09/08 Issued Date : 2025/09/10 Test Sample : TCED250900783-M-01 Standard(s) : ANSI/IEEE Std 149-2008 Applicant : AQUAGEM TECHNOLOGY LIMITED Address : FLAT/RM H 19/F, MAXGRAND PLAZA, 3 TAI YAU STREET, SAN PO KONG KL. HONG KONG Manufacturer : AQUAGEM TECHNOLOGY LIMITED Address : FLAT/RM H 19/F, MAXGRAND PLAZA, 3 TAI YAU STREET, SAN PO KONG KL. HONG KONG TOWE. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. the results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of the model are manufactured with identical electrical and mechanical components. All sample tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. without written approval of TOWE, the test report shall not be reproduced except in full. Lin Qilong Approved By: Fan Jiafu Reviewed By: Page 2 / 16 Report No.: TCED25090078301 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. Table of Contents REVISION HISTORY ....................................................................................................... 3 1 . CERTIFICATE OF COMPLIANCE ............…
Text truncated - open the document above for the full version.
3722 Illinois Avenue, · Saint Charles, Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 36.40 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 4.40 mW |

POOL ACTUATOR TRANSFORMER
Equipment Class
DTS - Digital Transmission System