POOL ACTUATOR TRANSFORMER I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L Follow this QR code for installation and operation manual T H A N K Y O U F O R P U R C H A S I N G O U R P O O L A C T U A T O R T R A N S F O R M E R . THIS MANUAL CONTAINS IMPORTANT INFORMATION THAT WILL HELP YOU IN OPERATING AND MAINTAINING THIS PRODUCT. PLEASE READ THE MANUAL CAREFULLY BEFORE INSTALLATION & OPERATION AND RETAIN IT FOR FUTURE REFERENCE. CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS ................................................................................... 1 2. TECHNICAL SPECIFICATIONS .......................................................................................................... 2 3. OVERALL DIMENSION ....................................................................................................................... 2 4. PRODUCT ILLUSTRATION ................................................................................................................ 3 5. LIGHT CHART ....................................................................................................................................... 4 6. INSTALLATION ..................................................................................................................................... 4 7. SETTING AND OPERATION ............................................................................................................... 7 8. WIFI OPERATION ................................................................................................................................. 9 9. TROUBLE SHOOTING ...................................................................................................................... 21 10. WARRANTY & EXCLUSIONS ........................................................................................................ 24 11. DISPOSAL .......................................................................................................................................... 24 1 1. IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1) READ AND FOLLOW ALL INSTRUCTIONS. 2) Installation shall comply with the applicable requirements of the current National Electrical Code® (NEC®) or Canadian Electrical Code (CEC), as appropriate. 3) WARNING – To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 4) WARNING – Installation and maintenance work must be performed by a licensed electrician. 5) WARNING – Before installation or maintenance, be sure to turn off the power switch on the left side of the transformer. 6) WARNING – To reduce the risk of electric shock, replace the damaged cord immediately. 7) Can be used to connect 1 to 3 valve actuators. 8) CAUTION: To ensure continued protection against shock hazard, use only identical replacement parts when servicing. 9) The transformer is not submersible. 10) Do not remove the insulator covering the terminals. 11) SAVE THESE INSTRUCTIONS. 2 2. TECHNICAL SPECIFICATIONS 3. OVERALL DIMENSION (mm) Model INPUT 120VAC, 60Hz PAT01 Load Capacity 1 to 3 sets of 24 VAC, 60 Hz, 0.75 A valve actuators System Wireless Type: 2.4GHz APP: Moov Pool Ai app IOS: 14.0 or higher Android: 7.0 or higher 3 Figure 1 - Pool Actuator Transformer Dimensions 4. PRODUCT ILLUSTRATION Figure 2 - Product Illustration Control Panel Electrical Connection Valve Actuator Wiring Terminal Power Supply Terminal Magnetic Flip Cover 4 5. LIGHT CHART 6. INSTALLATION 6.1. Mounting the Pool Actuator Transformer 1) Select an appropriate wall-mounting location based on the length of the power cord and the positions of the connected valve actuators. 2) Hold the box in place and use the three holes (FIG.3) to mark position on the mounting surface. 3) The transformer should be installed horizontally and fixed in the hole on the support with screws to prevent unnecessary vibration. Light Chart Name Color Indicator Status Device Status Wi-Fi Indicator White Blinks slowly Connecting Steady On Connected Off No connection/Disconnected Load Indicator 1 White Blinks slowly Valve actuator operation failure Steady On Auto On 1 Off Not in Auto On 1 Load Indicator 2 White Blinks slowly Valve actuator operation failure Steady On Auto On 2 Off Not in Auto On 2 5 Figure 3 - Mounting Holes 6.2. Connecting the Wires 1) Remove the four screws securing the wiring compartment cover. Press the area indicated by the label to release and open the cover. Loosen the waterproof cable gland nut and remove the rubber plug. 2) Route the actuator power cable through the waterproof cable gland nut and rubber plug, then insert the power connector into the terminal strip (FIG.4). 3) Install the rubber plug, and screw the nut back on. Put the wiring cover back on and tighten the four screws. Mounting Hole power switch 6 Figure 4 - Wiring steps NOTE 1)Before installation, please confirm the Wi-Fi signal is strong enough. 2)Wi-Fi range can be affected by obstructions, metal objects, distance and weather. Mount unit should be as close to the router as possible. 3)Install the unit in a vertical orientation. → → 7 6.3. Check before initial startup Check whether power supply voltage and frequency conform to the nameplate. 7. SETTING AND OPERATION 7.1. Display on control panel ① Wi-Fi indicator blinks slowly : connecting steady On : connected off: disconnected / no connection ② Wi-Fi pairing switch : press and hold for 3 seconds to start pairing ③ valve actuator 1 status indicator indicator 1 on: valve actuator is in auto on 1 state indicator 2 on: valve actuator is in auto on 2 state off: not connected ④ valve actuator 1 state toggle : tap to toggle the actuator state between auto on 1 and auto on 2 ⑤ valve actuator 2 status indicator indicator 1 on: valve actuator is in auto on 1 state indicator 2 on: valve actuator is in auto on 2 state Off: not connected…
Text truncated - open the document above for the full version.
Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 18, 2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2BRMV-PAT01 Applicant FRN: 0037382850 AQUAGEM TECHNOLOGY LIMITED (“the applicant”) certifies that, as of the date of the filing of the application, FCC US Agent, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. AQUAGEM TECHNOLOGY LIMITED accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. FCC US Agent, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: FCC US Agent, LLC U.S. Agent FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Tel.: 708-571-3148 Email: [email protected] Sincerely, AQUAGEM TECHNOLOGY LIMITED FCC US Agent, LLC Zhengrong Zou Tim Payne [Insert Applicant signature] [U.S. Agent signature]
Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-15-2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BRMV-PAT01 AQUAGEM TECHNOLOGY LIMITED (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. AQUAGEM TECHNOLOGY LIMITED (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) Zhengrong Zou Rev 1/26/2023 AQUAGEM TECHNOLOGY LIMITED Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 08-15-2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID:2BRMV-PAT01 AQUAGEM TECHNOLOGY LIMITED (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) Zhengrong Zou
AQUAGEM TECHNOLOGY LIMITED Date:August 15, 2026 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID:2BRMV-PAT01 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Schematics Block Diagram Operational Description Schematic.pdf Block Diagram.pdf Operational Description.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou/Engineer Typed name and Title
AQUAGEM TECHNOLOGY LIMITED Difference Declaration Date: August 15, 2026 We, AQUAGEM TECHNOLOGY LIMITED declare that model PAT01 and MT24S are totally identical product except their trade mark. Model Belong to Trade Mark Company Website PAT01 FAIRLAND HOLDINGS CO.,LTD www.fairland.com.cn MT24S AQUAGEM TECHNOLOGY LIMITED www.aquagem.com Sincerely AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou / Engineer Typed name and Title
AQUAGEM TECHNOLOGY LIMITED FCC ID: 2BRMV-PAT01 POWER OF ATTORNEY Date: August 15, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Testing Group (Foshan) Co., Ltd. (Dara Zhou) on our behalf shall have the same effect as acts of our own. This authorization expires on August 15, 2027 . This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, AQUAGEM TECHNOLOGY LIMITED are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, AQUAGEM TECHNOLOGY LIMITED Signature Zhengrong Zou/Engineer Typed name and Title
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 1 of 4 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 2 of 4 Picture 3 Picture 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 3 of 4 Picture 5 Picture 6 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 4 of 4 Picture 7
Label Location
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 1 of 8 Picture 1 Picture 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 2 of 8 Picture 3 Picture 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 3 of 8 Picture 5 Picture 6 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 4 of 8 Picture 7 Picture 8 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 5 of 8 Picture 9 Picture 10 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 6 of 8 Picture 11 Picture 12 ANT Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 7 of 8 Picture 13 Picture 14 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Reference No.: WTF26F07207772W Page 8 of 8 Picture 15
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn RF Exposure Requirements 1 General Information Client Information Applicant ....................................... : AQUAGEM TECHNOLOGY LIMITED Address of applicant ................... : FLAT / RM H 19/F MAXGRAND, PLAZA 3 TAI YAU STREET, SAN PO KONG KL, Hong Kong Manufacturer ................................. : Aquagem Manufacturing Limited Address of manufacturer ............. : NO.15, 101, 16, 401, 501, No.193, Jinlong Road, Dalong Street, Panyu District, Guangzhou General Description of E.U.T FCC ID ............................................ : 2BRMV-PAT01 Product Name ............................... : POOL ACTUATOR TRANSFORMER Model No. ..................................... : PAT01, MT24S Model Description ........................ : Two models are identical except model name. Therefore the full tests were performed on model PAT01. Rated Voltage ................................ : 120V~, 60Hz Technical Characteristics of EUT 2.4G WiFi Specification Support Standards ....................... : 802.11b, 802.11g, 802.11n Frequency Range ......................... : 2412-2462MHz for 802.11b/g/n(HT20) 2422-2452MHz for 802.11n(HT40) RF Output Power .......................... : 15.45dBm (Conducted ) Modulation .................................... : 802.11b: DSSS(DBPSK/DQPSK/CCK) 802.11g/n: OFDM (BPSK/QPSK/16QAM/64QAM) Quantity of Channels ................... : 11 for 802.11b/g/n(HT20); 8 for 802.11n(HT40) Channel Separation ...................... : 5MHz Type of Antenna ........................... : FPC IPEX Antenna Antenna Gain* ............................... : -2.38dBi *The antenna gain information is provided by the customer. The laboratory is not responsible for the accuracy of the antenna gain information. Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn BLE Specification Bluetooth Version ........................... : Bluetooth LE Frequency Range ........................... : 2402-2480MHz RF Output Power ............................ : 3.58dBm (Conducted) Modulation ...................................... : GFSK Data Rate ......................................... : 1Mbps Quantity of Channels ..................... : 40 Channel Separation ........................ : 2MHz Type of Antenna ............................. : FPC IPEX Antenna Antenna Gain* ................................. : -2.38dBi *he antenna gain information is provided by the customer. The laboratory is not responsible for the accuracy of the antenna gain information. Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 2 Applicable Standard According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density 3 Calculation Method S = (30*P*G) / (377*R 2 ) S = power density (in appropriate units, e.g., mw/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mw) G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor is normally numeric gain. R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm), R=20cm. 4 MPE Calculation Result Frequency (MHz) Antenna Gain (dBi) Numeric gain Conducted Power (dBm) Maximum Tune-up output power PD (mW/cm2) Limit (mW/cm2) (dBm) (mW) 2462 -2.38 0.58 15.45 16.00 39.81 0.00458 1.0 Result: Pass ======End of Report======
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 57 WT-510-201-12-A TEST REPORT Reference No. .................... : WTF26F07207772W001 FCC ID ................................ : 2BRMV-PAT01 Applicant ............................ : AQUAGEM TECHNOLOGY LIMITED Address .............................. : FLAT / RM H 19/F MAXGRAND, PLAZA 3 TAI YAU STREET, SAN PO KONG KL, Hong Kong Manufacturer .................... : Aquagem Manufacturing Limited Address .............................. : NO.15, 101, 16, 401, 501, No.193, Jinlong Road, Dalong Street, Panyu District, Guangzhou Product Name .................... : POOL ACTUATOR TRANSFORMER Model No. ........................... : PAT01, MT24S Test specification .............. : FCC CFR47 Part 15 Subpart C (Section 15.247) Date of Receipt sample .... : 2026-07-15 Date of Test ....................... : 2026-07-17 to 2026-07-21 Date of Issue ...................... : 2026-08-18 Test Report Form No. ....... : WEW-15247A-01B Test Result ......................... Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Foshan) Co., Ltd. Address: 1/F., Building 19, Sunlink Machinery City, Xingye 4 Road, Guanglong Industrial Park, Chihua Neighborhood Committee, Chencun, Shunde District, Foshan, Guangdong, China Tel:+86-757-23811398 Fax:+86-757-23811381 E-mail:[email protected] Tested by: Approved by: Jess Chen Danny Zhou Reference No.: WTF26F07207772W001 Page 2 of 57 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 1 Revision History Test Report No. Date of Issue Description Status WTF26F07207772W001 2026-08-18 Original Valid Reference No.: WTF26F07207772W001 Page 3 of 57 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn WT-510-201-12-A 2 Contents Page 1 REVISION HISTORY ................................................................................................................................. 2 2 CONTENTS ............................................................................................................................................... 3 3 GENERAL INFORMATION ....................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T ................................................................................................... 4 3.2 TECHNICAL CHARACTERISTICS OF EUT ........................................................................................... 4 3.3 STANDARDS APPLICABLE FOR TESTING ............................................................................................ 4 3.4 TEST FACILITY ................................................................................................................................ 5 3.5 SUBCONTRACTED ........................................................................................................................... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 3.7 DISCLAIMER .................................................................................................................................... 5 4 EUT SETUP AND TEST MODE ................................................................................................................ 6 5 EQUIPMENT USED DURING TEST ......................................................................................................... 7 5.1 EQUIPMENT LIST ............................................................................................................................. 7 5.2 TEST SOFTWARE ............................................................................................................................ 8 5.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ......................................................................... 9 5.4 MEASUREMENT UNCERTAINTY ......................................................................................................... 9 6 SUMMARY OF TEST RESULT .............................................................................................................. 10 6.1 ANTENNA REQUIREMENT ............................................................................................................... 11 6.2 RADIATED SPURIOUS EMISSIONS ................................................................................................... 12 6.3 POWER SPECTRAL DENSITY .......................................................................................................... 27 6.4 DTS BANDWIDTH .......................................................................................................................... 32 6.5 RF OUTPUT POWER ...................................................................................................................... 37 6.6 OUT OF BAND EMISSIONS .............................................................................................................. 43 6.7 CONDUCTED EMISSIONS................................................................................................................ 51 7 PHOTOGRAPHS TEST SETUP ............................................................................................................. 55 7.1 PHOTOGRAPHS - RADIATED EMISSION TEST SETUP ........................................................................ 55 7.2 PHOTOGRAPHS – CONDUCTED EMISSION TEST SETUP ................................................................... 56 8 PHOTOGRAPHS – EUT CONSTRUCTIONAL DETAILS ...................................................................... 57 Reference No.: WTF26F07207772W001 Page 4 of 57 Waltek Testing Group (Foshan) Co., Ltd.…
Text truncated - open the document above for the full version.
Sushi TOWE Wireless Testing (Shenzhen) Co., Ltd. Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. Antenna Passive Test Report Project No. : TSED260700732 Product Type : POOL ACTUATOR TRANSFORMER Test Mode : Free Space Date of Receipt : 2026/07/20 Date of Test : 2026/07/20 Issued Date : 2026/07/28 Test Sample : HTB260700079-001 Standard(s) : ANSI/IEEE Std 149-2008 Applicant : AQUAGEM TECHNOLOGY LIMITED Address : FLAT/RM H 19/F, MAXGRAND PLAZA, 3 TAI YAU STREET, SAN PO KONG KL. HONG KONG Manufacturer : AQUAGEM TECHNOLOGY LIMITED Address : FLAT/RM H 19/F, MAXGRAND PLAZA, 3 TAI YAU STREET, SAN PO KONG KL. HONG KONG TOWE. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. the results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. It is the manufacturer's responsibility to assure that additional production units of the model are manufactured with identical electrical and mechanical components. All sample tested were in good operating condition throughout the entire test program. Measurement Uncertainties are published for informational purposes only and were not taken into account unless noted otherwise. without written approval of TOWE, the test report shall not be reproduced except in full. Lin Qilong Approved By: Fan Jiafu Reviewed By: Page 2 / 16 Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. Table of Contents REVISION HISTORY ....................................................................................................... 3 1 . CERTIFICATE OF COMPLIANCE ............................................................................. 4 1.1 DESCRIPTION OF EUT AND TEST(S) PERFORMED ....................................................................... 4 1.2 LABORATORY ENVIRONMENT .......................................................................................................... 4 2 . MEASUREMENT SYSTEM INFORMATION .............................................................. 5 2.1 GENERAL INFORMATION .................................................................................................................. 5 2.2 LIST OF EQUIPMENT .......................................................................................................................... 7 2.3 MEASUREMENT UNCERTAINTY ....................................................................................................... 8 3.TEST RESULTS ........................................................................................................... 9 4. 2-D PATTERN PLOTS .............................................................................................. 10 5. 3-D PATTERN PLOTS .............................................................................................. 13 6. THE EUT AND TEST CONFIGURATION ................................................................. 15 APPENDIX A ANTENNA SPECIFICATION .................................................................. 16 Page 3 / 16 Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. REVISION HISTORY Rev. Issue Date Description Revised by 01 2026/07/28 Original Fan Jiafu Page 4 / 16 Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. 1. CERTIFICATE OF COMPLIANCE 1.1 DESCRIPTION OF EUT AND TEST(S) PERFORMED Manufacturer AQUAGEM TECHNOLOGY LIMITED Model PAT01 Serial Number(s) / ESN(s) / IMEI(s) N/A Hardware Version N/A Software Version N/A 1.2 LABORATORY ENVIRONMENT Temperature Min = 20°C , Max = 24°C Relative humidity Min = 30% , Max = 70% Shield effect 0.6 – 8.5G >100dB Ground resistance <0.5Ω Page 5 / 16 Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from TOWE. 2. MEASUREMENT SYSTEM INFORMATION 2.1 GENERAL INFORMATION Measurement Facility: ⚫ Measurement Chamber: ETS-Lindgren 3D fully anechoic chamber and its measuring system (AMS- 8923) ⚫ ETS-Lindgren EMCenter ⚫ Vector Network Analyzer: R&S ZNB8 Instruments View Page 6 / 16 Report No.: TSED26070073201 Sushi TOWE Wireless Testing(Shenzhen) Co., Ltd. Email: [email protected] Tel.: +86-755-27212361 TOWE-QP-15-F05 Rev.1.2 All rights reserved. Unless otherwise specified, …
Text truncated - open the document above for the full version.
Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 44 WT-510-201-12-A TEST REPORT Reference No. .................... : WTF26F07207772W002 FCC ID ................................ : 2BRMV-PAT01 Applicant ............................ : AQUAGEM TECHNOLOGY LIMITED Address .............................. : FLAT / RM H 19/F MAXGRAND, PLAZA 3 TAI YAU STREET, SAN PO KONG KL, Hong Kong Manufacturer .................... : Aquagem Manufacturing Limited Address .............................. : NO.15, 101, 16, 401, 501, No.193, Jinlong Road, Dalong Street, Panyu District,…
Text truncated - open the document above for the full version.
3722 Illinois Avenue · Saint Charles, Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 35.10 mW |
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.30 mW |

Inverter Pool Pump
Equipment Class
DTS - Digital Transmission System