2BSVF-CY-090BED WETTING ALARM

Dongguan Caiyun Technology Co.,Ltd
BED WETTING ALARM - FCC ID 2BSVF-CY-090 - Dongguan Caiyun Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jan 06, 2026
Application Purpose
Original Equipment
Equipment Note
BED WETTING ALARM
Frequency Range
433.92000000 - 433.92000000
Company
Dongguan Caiyun Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

产品组成 开关机 定时模式设置 尿液检测模块佩戴方式1 尿液报警器使用说明 忙 4 . 感谢您购买我们的产品使用前, 话务必仔细阅读此说明书井妥;;;保性,以备将来参考。 充电盒(收纳盒) 发射器(检刃尿液) 尿滇报警器由三个部分构成: 发射ff(尿液捡熏):检浏尿液通过无线方式发送抵警信息给接收器 兼收抖:签收器用于接收发射器报警信息,通过累动或者声音方式 通知用户. 充电盒(收纳盒):用千发射器,接收器的充电.不充电时盖上孟子 后方便用户收纳,携带. 震动指示灯 晌声指示灯 60分钟指示灯 30分钟指示灯 90分钟指示灯 不定时指示灯 厂 L 」 ( 心 ( \-: ❖� 磁 吸充电 口 上 十二 接收端背突 响声+震动 屯池指示灯 电豐指示灯 开关机按键+ 报警模式选择+ 定时模式选择 模式确认键 喇叭 接收器报警模式设匿 震动幔式设置: 按开机后默认无定时0小图标克起,双击开关键解除无定时,然后单击开关键 (设笸幌式)至履动O小图标灯不停闪烁,按确认谧,震动槛式设詈完成, 声耆模式设置 双击设置按钮,解锁,使足动仑小图标不停闪烁,然后继续单击设置 按钮声音仑小图标不悖闪烁,桉确认链,声古幔式设三结束. ..... 下) 震动加声音横式设置: 继续单击设董按钮,声音+烹动IQf小图标同时不停闪烁,按确认世, 声音加震动模式设至结束. 双击开关钮解除无定时,继续单击至, 30 、 60,90分钟的图标宽起, 然后按确认键,定时设置完成. 报警提示 当发出报竺授示时,用户单击开关贾或确认键就可以祒份报芒笺示 竹邑民倡及下) [J STEP.1 STEP.2 STEP.3 先把尿不浸里外反转将发射端肖夹尿不澄 打开禄应头夹子,折起 顶边固定 尿不湿放入夹Q STEP.4 按下感应扑夹子夹紧 STEP.5 符尿不逜翻转正面 然后给宝宝穿上 尿液检测模块佩戴方式2 产品充电 '"""况卜1 \ 、 1 ` STEP.6 将接收销放在方便 合适的位置 STE?.1 将发射喘告夹在内裤顶 边固定 T 1 广 , 、 STEP.2 打开感应头夹干析起内裤放入夹口 (慧应头灾子正反均句佩霓) STEP3 按下惑应器夹子如永然后给宝宝穿上 , , , 甲 STEP. 4 将接收玩放在方便合涵的位置 将接收器,发射器放入充电盒,潘入 US B充电,当充满电时,充电盒的 两个红色指示灯会熄灭. 注意事顶 1使用接收器温洹度功北时接收器不得愤姓 ' 如望于如口袋等节殊环 圾,不如温湿度传愍器孔位遗挡,接收,:j允电过程中温温度功 能无效. 2, 产品充电采用标准DC5V供电 3. 充 电完成后,产品不使用时可将接收器关机以节台电能消耗. 产品介绍 重要 在孩子入睡大约1至2个小时,家长想要完全弄l11孩子足不容易 的,而报荡器将会和助防止睡的太熟的孩子不会被叫醒. 通过白天让孩子小睡 一 会,埔保孩子在晚上睡觉不会筋疲力尽 这样将会有助干掖警器将孩子叫酵. 每天晚上霎提醒你的孩子,当听到报警声古时,须停止徘尿并 上劂所. 在晚上上床睡觉前,没必要限制液体的摄入云。 重要 在虽初的几阉里,当报芒器听起时奴子自己可能不会彼攒芒抖叫 酿,所以孩了m耍京长的帮助:叫醇孩子并上厕所. 孩子参与的过桯足芘了取得成功不可缺少的.不要为孩子拔下报 苦,让孩子自己察觉报芒器晌起井自己议下 ` 断开恨苦器为更好, 家长 斋要帮 助 孩子r下牛间排完尿在奻初的�孩子可耜 会在床上完全尿混但家长仍;;;在继续强调上厕所的正要性并月芯励他 忆呵颈子第二天足否记得报警器晌起和他们做了些什么, 重要 家长的参与对干这个计划的成功也袅侬杠私冷) , 在最初的几百l 内,孩子需要家长的帮助和鼓励.这个计划可能是缓慢和沮丧的,但 家1持每天陕上使用报芒器,每次训练过程报芒器都能正常响起, 家长要符助阳磕孩子. 你亏安坻续使用损昏器3至佃,亦确保孩了在虽后一次报警后不 会复发.复发是指孩子在一个月或更多月之后又连续尿湿.如果这种 情况发生,渭立刻开始酝使用拫斟器,这祥复友的I司漏将会变得墟 来越长. 计划 在报警器发生响声后,要给孩子重新连接报警器,同时要给孩子 换上尔新的内裤. 在孩子的房间使用一个通宵灯,这样有助孩 子在拫芒器饷起时更容易醒来,井且能够找到去卫生侚的路. 每次你牲咳子度过�的夜晚或察觉到报艺声,�耍表扬 他们.间仕亟要的是不要因为孩了没有察觉到报菩音而责骂他们,因 为改变孩子的行为要花费 一 些时间.此外,使用讲忠肥早很有帮助的, 以钳亥子能参尹扣划的出酐. 保养凡舫号 在每次有尿湿部分后记住要清理传感器夹子.如果有需要的话, 可 一 并擦干净报警器.不要把报警器本体浸在水里,因为这祥会损坏 内部零件,传感器夹子可在水里冲洗. 一定要经常 检 迂电池以确栾役芒器仍在工作.这可以通过在夹 子~间括入一块澄布来检益当很长时间不使用胺鳖器时,清取出电 池. 本公司报警器足为单个用户设计的,如柔你想另 一 个孩 子 使用报 告税,谔联,售买另外一个报警踩. \... . 尸 · 艺告:使用中报譬后,谓将发射端夹子打开并用干臾的纸巾憬 干净.方可 使 用。 ·Thank you for purchasing our products. Please read this manual carefully before use and keep it properly for future reference. Product Composition Charging box (Storage box] Transmitter (Detecting urine) The urine alarm consists of three parts: Transmlner (urlnedetec【Ion):Detect urine and send alarm 1nformat1on to receiver bywrreless way. Receiver: The receiver Is used to receive the alarm Information from the I『ansmitterandnotifythevibration or sound Charging box (storage box); used fo「cha「ging t『ansmitterand receiver. when not charging, ,t isconvenient for users to store and carry after being covered. Switch on/ off Vibration lnd,cator Ughl Sound�dicator Light 00-Min, 汪lodicato『Light 扣-Mioutelodirato,Light 00-Mlnu芘lndlc改o,Ug>t lnterm,ttent Indicator light Magnet;, Ch,n,;ng Port ••ceive, Clip Vibration mode setting: Afte「P『essingthe powe「buttcn,the def au II No Timer O iconUghls up. Double-cUcklhe power buttnnto disablelhe No Timer mode, 1hen51ngle-rhck the power button (tu enter setting made) until the "Vib『ation"<,> icon flashes continuously. P『essth釭onfirmalion button, and the vibration mode setup is complete. Sound• v,bratio• Batt盯ylndlcator Powe『LevellMICator Power•Alarm Mode• Timer Mode Modeconflrm Speak« Receiver alarm mode setting ''""'"'""' Sound mode setting: Double click the setting button to unlock and make the small icon of vib,ation Qi ofv,b,at,onflick巴,;Then continue to click the企廿ing button, the small sound'11 flashes continuously, And press the OK key to end the sound mode setting (lamootoso} Vibration plus sound mode setting: Continue to click the setting bullon, and the small icons of sound+ vibration 1Qi will仆ickerat the same time. P飞ssthe OK key to end the setting of sound and vibration mode {>oc. 江eof,se) Timer Mode Setup Double-click the power button to d,sable the No Timer mode. continue single-clicking until the JO-minute, 60-minute, o『 90-minute icon lights up, then press the confirmation button to complete the timer setup (1oc,seetcst1 Alarm prompt When an alarm notification is t『iggered,the user can press either the powe『buttono『 theconfi「mationbutton to deactivate it. 飞l Wearing Method of the Urine D气ectionModule-1 『; STEP.1 ,; 卤,tu『nthed,aoe『 ;ns;deaut. STEP.4 P 妇··t芯<the如虹 clip to asteo itt i ghtly. STEP.2 Plea艾fastenthe tran,m;ne,d;p to the top edge ofthe d;aper. 5Tl"P.5 兀mthed;aper,;rs;de outandt氏nput ton the baby. ` ` ' `. 5rrP3 Opecttie父书o,h的dcUp , 伈tdthediap«.andp缸:c lt intcthe cbocoenico STER6 Please place the receiver In• convenient and ,uit,blol可cation. Wearing Method of the Urine Detection Module-2 STE?.l S'『''-' Secucethe launch end Open the sen,;,g head,,., fold up the back ta the tap edge of undecweac and pu由;n,a你ed;pan;ng. theondecwea『(Thesensa, head chp can be叩m『�llhe,dl飞ctlon) , 户 } - 5TEe3 Secure the Launch end back to the to p edge of the und仑rwear The transmitter of the unde,wea, is worn insid• .,.,w, 扯r心”“讥""°''比 ""'盯w,o,m淇"''''''""· ,od,,;,wom;a,;;, - � 亨 STEP.4 Open 1hesensing庙ad":f' fold up the undo.wear ,n pull! Into the clip opening Thet,ansm;tterofth巳 undo八心ar;s worn ou«;do "Thrndm它省「m叩,i.hu 8 。"掏僵, 于 ,�.户'·-··心,. om• 几.,,. Product Cha『ging Please place the receiver and transmitter Into the charg1ng case and plug in the USB cable for charging. When fully charged, the two red indicator lights on the charging case will turn off. { Matters needing attention 1. When using the receiver's temperature and humldltyfunctlon, the receiver sha[ notcontacto『 be placed Ina special envlronmentsuch as• poc and the hole position ofthetem erature and humiditysensorshallnot e blocked. Th f e receiver's tempe『aure and humidity function is invaud during cha『ging. 2. lhe product is charoed by s归nda『d□csv 3. After charging, the receiver ,an bewrned off when the product is not in use to save power consumption Product introduction Importance lt is not…

Text truncated - open the document above for the full version.

Attestation Statements

Dongguan Caiyun Technology Co.,Ltd Covered Equipment Certification Attestation Letter 12/30/2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BSVF-CY-090 Dongguan Caiyun Technology Co.,Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Dongguan Caiyun Technology Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Dongguan Caiyun Technology Co.,Ltd (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). <Signature>: Name: Jack bu Title: Manager Company: Dongguan Caiyun Technology Co.,Ltd Date: 12/30/2025

Attestation Statements

Dongguan Caiyun Technology Co.,Ltd * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 12/27/2025 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BSVF-CY-090 FRN of applicant: 0037614401 Per section 2.911(d)(7) of the FCC rules, [Dongguan Caiyun Technology Co.,Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Herland International Trading Inc FCC Registration Number (FRN): 0036324101 Physical U.S. Company Address: 1370 Valley Vista Dr Ste 200 Diamond Bar California 91765- 3921 Contact Person: Jianfeng Gao Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Jack bu Title: Manager Company Name: Dongguan Caiyun Technology Co.,Ltd Date: 12/27/2025 Agent Signed (if different from Applicant): Signed: Printed name: Jianfeng Gao Title: Manager Company Name: Herland International Trading Inc Date: 12/27/2025

Cover Letter(s)

Dongguan Caiyun Technology Co.,Ltd 2025-12-30 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BSVF-CY-090 Product Name: BED WETTING ALARM Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...)  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name: Jack bu Title: Manager Company: Dongguan Caiyun Technology Co.,Ltd

Cover Letter(s)

Dongguan Caiyun Technology Co.,Ltd 2025-12-30 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen DL Testing Technology Co., Ltd.(101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China)to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Dongguan Caiyun Technology Co.,Ltd(ROOM 802, Yuanchen Building, No.3 Hanken Road Yanwu Dalingshan, Dongguan City, China) <Signature>: Name: Jack bu Title: Manager Company: Dongguan Caiyun Technology Co.,Ltd

Cover Letter(s)

Dongguan Caiyun Technology Co.,Ltd 2025-12-30 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, <Signature>: Name: Jack bu Title: Manager Company: Dongguan Caiyun Technology Co.,Ltd

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size:16*12mm M/N: CY-090 FCC ID: 2BSVF-CY-090 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. ANT Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

RF Exposure Info

FCC ID: 2BSVF-CY-090 RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=E Meas +20log(d Meas )-104.7 EIRP is the equivalent isotropically radiated power, in dBm E Meas is the field strength of the emission at the measurement distance, in dBμV/m d Meas is the measurement distance, in m Here, Field strength (dBuV/m) EIRP (dBm) Max tune-up (mW) Frequency (MHz) Min. distance(mm) Calc. thresholds limit 56.07 -39.1 0.0001 433.92 5 0.00002 3.0 So a SAR test is not required

Test Report

ShenzhenYuanDongliDigitalTechnologyCo.,Ltd. Address:3F,BuildingA,RuixingSciencePark,No.6SanheRoad,DalangPeakCommunity,LonghuaDistrict,Shenzhen Phone:86-755-8326-6570Fax:86-755-83255400 1 BluetoothAntennaSampleAcknowledgement BTAntennaProductApproval Time:2020-12-4 1.IntroductiontoAntennas OurBluetoothantennaisdirectlyfabricatedonaPCBboardusingacopper-solderedandtin-plated process.ThecopperfoilthicknessisH/HOZ,andtheboardismadeofFR-4materialwitha1.0mm thickness. ShenzhenYuanDongliDigitalTechnologyCo.,Ltd. Address:3F,BuildingA,RuixingSciencePark,No.6SanheRoad,DalangPeakCommunity,Longhua District,Shenzhen Phone:86-755-8326-6570Fax:86-755-83255400 2 II.AntennaShape 1.184420Dimensiondiagram:.*.*.5mm ShenzhenYuanDongliDigitalTechnologyCo.,Ltd. Address:3F,BuildingA,RuixingSciencePark,No.6SanheRoad,DalangPeakCommunity,LonghuaDistrict,Shenzhen Phone:86-755-8326-6570Fax:86-755-83255400 3 III.AntennaParameters Antennacenterfrequency:433MHz;bandwidth:420-446MHz;gain:1.5dBi(omnidir- ectional),resonatinginthisfrequencyband.Thetablebelowliststheantenna'skeyparameters. 433Mbuilt-inantenna Frequency(MHz)420~446MHz VSWR≤1.92 Impedance50OhmNominal PolarizationVerticalpolarization Powercapacity 1W Gain (Peak)1.5dBi Standingwavebandwidth ≥26MHz Productiveness>25%

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 27 FCC Part 15C Test Report FCC ID: 2BSVF-CY-090 Applicant: Dongguan Caiyun Technology Co.,Ltd Address: ROOM 802, Yuanchen Building, No.3 Hanken Road Yanwu Dalingshan, Dongguan City, China Manufacturer: Dongguan Caiyun Technology Co.,Ltd Address: ROOM 802, Yuanchen Building, No.3 Hanken Road Yanwu Dalingshan, Dongguan City, China Product Name: BED WETTING ALARM Trade Mark: N/A Model Number: CY-090 Date of Receipt: Dec. 18, 2025 Test Date: Dec. 18, 2025 - Dec. 27, 2025 Date of Report: Dec. 27, 2025 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.231 ANSI C63.10:2020 Test Result: Pass Report Number: DLE-251218044R Prepared (Test Engineer): Alisa Song Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 27 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 5 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 6 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 6 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 7 3 . EMC EMISSION TEST 8 3.1 CONDUCTED EMISSION MEASUREMENT 8 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 8 3.1.2 TEST PROCEDURE 8 3.1.3 DEVIATION FROM TEST STANDARD 8 3.1.4 TEST SETUP 9 3.1.5 EUT OPERATING CONDITIONS 9 3.1.6 TEST RESULTS 9 3.2 RADIATED EMISSION MEASUREMENT 12 3.2.1 RADIATED EMISSION LIMITS 12 3.2.2 TEST PROCEDURE 13 3.2.3 DEVIATION FROM TEST STANDARD 13 3.2.4 TEST SETUP 14 3.2.5 EUT OPERATING CONDITIONS 15 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 16 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 17 3.2.8 TEST RESULTS (1GHZ~25GHZ) 20 4 . BANDWIDTH TEST 21 4.1 APPLIED PROCEDURES / LIMIT 21 4.1.1 TEST PROCEDURE 21 4.1.2 DEVIATION FROM STANDARD 21 4.1.3 TEST SETUP 21 4.1.4 EUT OPERATION CONDITIONS 21 4.1.5 TEST RESULTS 22 5 . CALCULATION OF AVERAGE FACTOR 23 5.1 APPLIED PROCEDURES / LIMIT 23 5.1.1 TEST PROCEDURE 23 5.1.2 TEST SETUP 23 5.1.3 EUT OPERATION CONDITIONS 23 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 27 Table of Contents Page 5.1.4 TEST RESULTS 24 6 . TRANSMISSION CEASE TIME 25 6.1 APPLIED PROCEDURES / LIMIT 25 6.1.1 TEST PROCEDURE 25 6.1.2 DEVIATION FROM STANDARD 25 6.1.3 TEST SETUP 25 6.1.4 EUT OPERATION CONDITIONS 25 6.1.5 TEST RESULTS 26 7 . ANTENNA REQUIREMENT 27 7.1 STANDARD REQUIREMENT 27 7.2 EUT ANTENNA 27 8 . TEST SEUUP PHOTO 27 9 . EUT PHOTO 27 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 27 1.. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.231) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.209,15.231b Fundamental &Radiated Spurious Emission Measurement PASS 15.231a Transmission cease time PASS 15.215 20dB Bandwidth PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1. MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 20dB Bandwidth ±0.2MHz Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 27 2.. GENERAL INFORMATION 2.1. GENERAL DESCRIPTION OF EUT Product Name: BED WETTING ALARM Trade Mark: N/A Model Number: CY-090 Model Difference N/A Operation Frequency: 433.92MHz Channel numbers: 1 Channels Modulation technology: ASK Antenna Type: Internal Antenna Antenna gain: 1.5dBi Power supply: DC 3.7V from battery DC 5V from charging case Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2.2. DESCRIPTION OF TEST MODES Note: (1) New battery is used during the test. (2) The test was conducted by pressing the middle button of the product. To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 TX Mode Mode 2 Charging Mode Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-251218044R Test Report Tel: 4…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. Conducted Measurement Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Jack bu
[email protected]Fax: 18906679427

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]Fax: (909) 772-1888

1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 · Diamond Bar, 91765 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-